HOME INSPECTOR EDUCATION EXPO 2016

Similar documents
Inspection Checklist Mechanical Final

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Inspection Checklist Mechanical Rough in

RESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

Residential Gas Water Heater with the Flame Guard Safety System Installation Instructions and Use & Care Guide (Flammable Vapor Ignition Resistant)

RESIDENTIAL GAS WATER HEATERS FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR POTABLE WATER HEATING ONLY. NOT FOR USE IN MOBILE HOMES.

FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR SPACE HEATING AND POTABLE WATER HEATING ONLY. NOT FOR USE IN MOBILE HOMES.

Residential Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide

RESIDENTIAL GAS WATER HEATERS FVIR GAS WATER HEATER (FLAMMABLE VAPOR IGNITION RESISTANT) FOR SPACE HEATING AND POTABLE WATER HEATING ONLY.

USER S INFORMATION MANUAL

Installation Instructions and Use & Care Guide

Mechanical Appliance and Equipment Inspection Checklist

RESIDENTIAL GAS WATER HEATERS

INSTALLATION & SERVICE MANUAL

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

HVAC Equipment Access Equipment Location

Energy Smart Gas Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide

2015 MECHANICAL CODE REQUIREMENTS

Building Department Informational Handout

PVE SERIES POWER VENTER SYSTEM MANUAL

Notable Changes in the Mechanical Codes

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Do not use this vent pipe or fittings for venting incinerators of any kind.

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

C O D E S & A M M E N D M E N T S

Installation Instructions

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

piping. COMBUSTION AIR CHAPTER 17

POWER VENTER. Model: PVE Series

User s Information Manual

RESIDENTIAL GAS WATER HEATERS

For Manufactured Housing

operating, installation and service manual

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

For Manufactured Home (Mobile Home) Installations

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

Whole House Action Guidelines

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.

SPECIFIC APPLIANCES CHAPTER 6

RESIDENTIAL GAS WATER HEATERS

MANUFACTURED HOME (MOBILE HOME) CLOSED COMBUSTION (DIRECT VENTING) INSTALLATION AND OPERATING INSTRUCTION MANUAL

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

I. STRUCTURAL SYSTEMS

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48

RESIDENTIAL POWER VENT GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

Residential Gas - FVIR Certified

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

Installation & Operation Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown

CHAPTER 8 CHIMNEYS AND VENTS

RESIDENTIAL GAS WATER HEATERS

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Residential Water Heater with the Flame Lock Safety System Installation Instructions and Use & Care Guide

GAS-FIRED WATER HEATER

Installation Instructions

2012 INTERNATIONAL FUEL GAS CODE VENTS

Installation Instructions

GAS-FIRED WATER HEATER

CHAPTER 8 CHIMNEYS AND VENTS

Oil-Fired Water Heater

GAS-FIRED WATER HEATER

GAS-FIRED WATER HEATER

Internet Version for Reference Only STORAGE UNIT

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

L O S S C O N T R O L

MI/MIH. Series. Gas. Boilers. Installation, Operation & Maintenance Manual

INSTALLATION INSTRUCTIONS FOR UPFLOW/HORIZONTAL (-)GPL AND DOWNFLOW (-)GLL TWO STAGE INDUCED DRAFT GAS FURNACES

CHIMNEYS AND VENTS CHAPTER 8

GAS-FIRED WATER HEATER

GAS-FIRED WATER HEATER

2012 International Fuel Gas Code Design, Installation and Inspection Principles

Inspection Checklist Residential Mechanical Rough In July 2016

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Installation Instructions and Use & Care Guide

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

Side Inlet - Direct Vent Gas. For Manufactured Housing

GAS BOILERS USER'S INFORMATION MANUAL SG-135-E TO SG-495-E AAA-480 TO AAA-3000

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

INSTALLATION INSTRUCTIONS

Introduction Engineering and Design Manual

Combustion Appliance Safety Testing Guidelines

Installation Instructions

INSTALLATION GUIDE Dual Fuel Ranges

MODEL BT- 65. COMMERCIAL GAS WATER HEATER Glass-Lined Tank-type Water Heater INSTALLATION OPERATION SERVICE MAINTENANCE LIMITED WARRANTY

Direct Vent System Required

Solar Water Heater. Use & Care Manual. FVIR Certified. Residential Gas - With Installation Instructions for the Installer

MODELS BTR(C)120 THRU 500A

DAMPER EQUIPPED GAS WATER HEATER

INSTALLATION MANUAL ALL POSITION AUTOMATIC IGNITION FURNACES UPFLOW / HORIZONTAL AUTOMATIC IGNITION FURNACES G8C / FG8 SERIES MODELS MBH INPUT

Gas Water Heaters. Use & Care Manual. FVIR Certified. With Installation Instructions for the Installer. 75 and 98 Gallon

Family Foster Home Fire Safety Evaluation Checklist Instructions

Transcription:

An Education in Hot Water HOME INSPECTOR EDUCATION EXPO 2016 Residential Water Heater Inspection

Course Objective Course Objective Completing this course should enable an inspector to identify components of gas-fired and electric residential water heaters; recognize defects and safety hazards in relation to modern standards and manufacturer requirements; explain how a flammable vapor ignition resistance system (FVIR) works; recognize the importance of temperature-and-pressure relief valves and the importance of checking confined spaces. *NOTE* This course in not intended to be a code compliance course. All standards and requirements covered in the course are superseded by any and all national, state, and local code enforcement.

Course Outline Course Outline Location Requirements Standard Installation Practices Basic Operation Resources

Water Heater Location

Water Heater Location Closets Gas water heaters should not be installed in a room used as a storage closet. Closet doors should be of louvered design.

Water Heater Location Bedroom/Bathroom Gas water heaters should not obtain combustion air from sleeping rooms, bathrooms or toilet rooms. There are two exceptions: 1. Installed within a sealed enclosure behind a solid weatherstripped door that prevents the water heater from pulling combustion air from the living space. The door must be selfclosing. 2. The water is of direct vent design.

Water Heater Location Garages Gas water heaters with an open source of ignition should be elevated not less than 18 inches above the garage floor or be FVIR compliant. The water heater should be installed in such a way that physical damage would be prevented from any impact.

Water Heater Location Attics A suitable access opening, passageway, and workspace is required for attic installations. The access opening should be large enough to accommodate removal of the water heater. The passageway should not be more that 20 long, be at least 30 wide, and have continuous flooring at least 24 wide. There should be a level workspace at least 30 wide at the service side of the water heater

Water Heater Location Mechanical Rooms Gas water heaters should not be installed in a room containing airhandling equipment when that room is used as a plenum.

Water Heater Location Confined Spaces A space is defined as confined if the volume of space in which the water heater is located is less than 50 cubic feet of space per 1,000 Btu of input. (50 cubic feet = 2.5ft. X 2.5ft. X 8ft.)

Water Heater Installation

Water Heater Installation Accessibility Water heaters should be accessible for routine inspections, maintenance, adjustments, repairs and replacements. Accessible means to reach the water heater by possibly first removing a panel, door, or similar obstruction that is part of the water heater. Accessible does not mean the removal of finish materials, such as drywall, paneling, or built-in cabinets.

Water Heater Installation Labeling All water heaters are manufactured with labeling that contain vital information for safe and reliable operation. These labels must be visible. All water heaters are manufactured with a data plate that indicates the model and serial number as well as other vital information like fuel type. The water heaters data plate should always be present.

Water Heater Installation Seismic Support In areas that have earthquake risk, it is important that a water heater be fastened in place with straps to avoid damage. Top strapping should be located in the upper one-third and the lower one-third of the units vertical dimension. The lower strapping should maintain a minimum distance of 4 above the controls. In addition to strapping, approved flexible connectors should be used.

Water Heater Installation Water Valves A water valve should be installed in the main cold water supply. The valve should be located near the water heater and accessible from the same floor level. The water valve should be of a full-open design as to not cause flow restriction. Ball valves are preferred.

Water Heater Installation Fuel Shut-off Valves A fuel shut-off valve for service, repair, and emergency shut-down should be installed for all gas water heaters. Fuel lines feeding gas water heaters should also incorporate a drip leg or dirt leg to prevent moisture and debris from entering the control.

Water Heater Installation Electrical Disconnects An electrical disconnect for service, repair, and emergency shut-down should be installed for all electric water heaters. The service wiring that supplies power to the water heater should be tightly secured with strain reliefs. The disconnect should be in line of sight of the appliance, or it should be capable of being locked in the open position, and the provision for locking should remain in place whether locked or unlocked.

Water Heater Installation Venting requirements UL listed Type B double or single wall metal vent pipe must be used. Some local codes may be more restrictive and not allow single wall. Single wall pipe may not pass through attic spaces, crawl spaces, confined inaccessible locations, or interior walls. Single wall pipe must maintain a 6 clearance from combustible material. Clearances for double wall pipe will be specified by the manufacturer.

Water Heater Installation Venting requirements To improve the flow of exhaust gases, we recommend that a minimum of 12 of vertical pipe be installed on the draft hood. Any horizontal runs should not be more than 75% of the total vertical rise. Horizontal runs should rise by ¼ per foot. If local codes allow, gas water heaters may terminate into an existing chimney. Otherwise, it must terminate vertically.

Water Heater Installation

Orphaned water heaters Water Heater Installation

Water Heater Installation Temperature and Pressure (T&P) relief valves In order to accurately sense the water temperature, the T&P valve must be located in the upper 6 of the water heater. The T&P valve should be visually and manually inspected to insure proper operation.

Water Heater Installation T&P discharge pipes The pipe should be constructed of materials tested, rated, and approved for such use. The pipe should not be directly connected to the draining system. The pipe should discharge through an air gap located in the same room as the water heater. The pipe should not be smaller than the diameter of the outlet valve it serves. The pipe should not have valves or tee fittings installed. The pipe should not have a threaded end. The pipe should serve one outlet valve only.

Water Heater Installation T&P discharge pipes The pipe should discharge to a positive drain. The pipe should not terminate more than 6 from the floor or drain. The pipe should discharge in a manner that does not cause personal injury or structural damage. The pipe should be installed as to flow by gravity. The pipe should discharge to a termination point that is readily observable by the building occupants. The pipe should not be trapped.

Water Heater Installation

Water Heater Installation Sacrificial Anode Rod The anode rod is a sacrificial metal rod that helps avoid corrosion and premature failure. The anode rod is a consumable item and will need to be replaced periodically. If the home has a water softener, the anode will deplete faster than normal.

Water Heater Installation Drain Pan The water heater should be installed in a drain pan when if it is located in an area where a leak would cause structural or property damage. The drain pan should not be less than 1.5 deep. A good rule of thumb on size is at least 2 larger than the diameter of the tank.

Water Heater Installation Drain Valve All water heaters should have a drain valve installed for service, maintenance, sediment removal, repair, and replacement. We recommend flushing the water heater through the drain valve annually to remove sediment.

Water Heater Installation Thermal Expansion Tanks All closed plumbing systems requires a thermal expansion control device such as a thermal expansion tank. Water expands when it is heated. Since the water is unable to expand back into the municipal system, the thermal expansion tank will absorb the expansion.

Water Heater Installation Fuel Conversions Fuel conversions are only allowed when converting from LP gas (propane) to natural gas. The conversion of a gas water heater from natural gas to propane is NOT allowed. The current fuel being used should match the fuel designation on the water heater s data plate.

Water Heater Installation Defects Check for physical damage to the water heater particularly rust and corrosion on the bottom of the water heater. Check for water marks on the floor. The inspection covers should not be disturbed. Check for scorching around the burner door. The outer door should be in place.

Water Heater Operation

Water Heater Operation Temperature regulation The magic number is 120. According the ASSE 1070, the water heater should not be the sole device for temperature control.

Water Heater Operation Water Pressure Most local codes dictate a maximum water pressure of 80 psi for residences. For water pressure above 80 psi, a Pressure Reducing Valve (PRV) should be installed. To help avoid premature failure, we recommend an operating pressure of 50 60 psi.

Water Heater Operation Flammable Vapor Ignition Resistant (FVIR) In 2003, a new standard for water heaters was developed that states the water heater should NOT ignite flammable vapors outside the water heater created by the spilling of gasoline onto the floor. FVIR compliant water heaters typically have three components in common: A Lint, Dust, Oil (LDO) screen A flame arrestor plate A thermal cut-off switch

Water Heater Operation Burner Flame The burner flame should be clear blue with slightly yellow tips. The burner flame should not appear to be erratic, searching or rolling out. The presence of soot would also be an indication of a lack of make-up air.

Water Heater Operation Proper Draft Test You will need something to generate smoke such as a candle, cigar, or cigarette anything that will produce smoke. Close all building doors and windows and all doors between the water heater location and other portions of the building. Also, close fireplace dampers. Turn on all air-moving appliances, such as clothes dryers, kitchen and bathroom exhaust fans, range hoods, and the heating furnace. Also, make sure that any other gas-burning appliance is operating.

Water Heater Operation Proper Draft Test Next, open a hot water faucet so that the burner will fire continuously. After the unit has been firing for approximately 5 minutes place the source of smoke close to the opening of the draft hood. The smoke should be pulled into and up the draft hood and not float around the draft hood. If the smoke does not continue to be pulled up the draft hood into the vent or blows back into the room, you have a venting problem that needs immediate attention.

Water Heater Operation Leaks If you see small puddles of water in the drain pan or hear sizzling sounds as water drips on the burner, the water heater may be producing condensation. If there is water on the floor around the bottom of the water heater, check the plumbing connections on top of the water heater. Use a dry paper towel to wipe around the hot and cold pipe connections on top of the water heater. If the hot and cold water connections are not leaking, check the T&P relief valve discharge pipe. In most cases, drips from your water heater s T&P relief valve discharge pipe mean the home s water pressure is too high or the home s thermal expansion tank has failed