CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Similar documents
DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

Flexible & Innovative. Cooling Solutions

Aquaflair TRAC-TRAF-TRAH

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

The integral solution for. Air Handling Units. Technology & Evolution

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

DC Inverter Smart VRF Products(R410A)

Flexible and efficient: Close Climate Control for IT equipment

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

APPLICATION GUIDE RHC - RNC - RNV. "In Row" close control unit for high density systems. 3 > 51 kw RACKCOOLAIR-AGU-1310-E. lennoxemeia.

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Precision air handling cabinets Ciatronic MICRO/EXPAIR

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

GP SERIES Packaged Chillers

Precision Air Conditioner For Critical Application

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

ARV.

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Guide Specifications for InRow Direct Expansion

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Water-cooled chillers with High Speed Centrifugal Compressors

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

H4T R410A. refrigerant


1

2013 Product Range Precision Air Conditioners (CRAC)

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM TFF COMBINATION HEATING/COOLING UNITS

Compact Ultra Low Temperature Chamber

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Compressors Manufacturing Company Ltd.

50TM COMBINATION HEATING/COOLING UNITS

Air-cooled modular Chiller. Nick Technical Engineer

AHU Plus. DX Air Handling Units

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Submitted to Reference Approval Construction Unit Designation Schedule #

KOMFORT EC DB Suspended heat recovery air handling units

Vertical self-contained air conditioner

Blue Box Epsilon Echos +

Submitted to Reference Approval Construction Unit Designation Schedule #

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

MODULAR CHILLER. R410a R22

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

20-120RT Multi-functional Modular Combination High Efficiency & Energy Saving Keeping Technology Cool

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

Neosys Product catalogue

SpaceKeeper Console (SKC)

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

YORK Close Control units

Super WISE. System product for Swegon s system for demand-controlled ventilation

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

MODEL NUMBER: SRCOOL60KCW

AQUASNAP JUNIOR 30RHV

Compact design & easy maintenance

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Air-Cooled Condensing Units with Compact Screw Compressors

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

TECHNICAL SPECIFICATIONS

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

CAREL heatersteam Electric Element Steam Humidifiers

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

next DX.U.S* 052.Z2.H6.DC

Service Step by Step Trouble-Shooting Check-List

Transcription:

CoolTeg Plus XC40 AC-TXC Direct expansion Air-conditioning unit with integrated compressor Application CoolTeg Plus XC40 is a revolutionary air-conditioning unit specifically designed for installation between IT racks in data centers. Each unit contains a powerful compressor, driving a built-in refrigerant circuit, along with an extremely high cooling capacity. CoolTeg units fit perfectly onto Conteg racks - having the same design, material, color and suitable dimensions, creating a uniform and comprehensive row. Generally, these units may be combined with any cabinets. Our new generation of air-conditioning units operates on the direct evaporation principle. Each includes a frequency driven compressor, evaporator, electronic expansion valve, fans and complex control system. They are linked to outdoor units (condensers) with refrigerant piping. XC40 units are available in many dimensional variants, corresponding to the height and depth of the surrounding racks. CoolTeg plus units can be installed either in open or closed hot and cold aisles. Their main task is transferring heat load from the data center while supplying cold air at precise temperature, humidity and airflow to servers. Compared to commercial split systems, CoolTeg units allow precise temperature control of exhaust air, along with an immediate reaction to cooling capacity requests, many times higher airflow, exactly corresponding to server requests. Moreover, all CoolTeg Plus units adjust humidity in the server room. A separated condenser allows operation in ambient air temperatures of up to 55 C.

Benefits High cooling capacity of compressor circuit (up to 42 kw) Built-in latest generation frequency-driven scroll compressor, reacting instantly to actual cooling capacity request Fluent cooling capacity control ranging from 20 to 100% Electronic expansion valve for maximal effectiveness and thermodynamic stability of entire circle Separated condenser allows cooling in extremely high ambient temperatures (up to 55 C) Condenser can be designed and customized according to climatic, space and acoustic conditions All important and critical components of refrigerant circuit are inside the building, so not exposed to outside environment (freezing or high temperatures, rain, snow, dust, etc.) Compatible with Conteg racks - having the same design, material, shape and dimensions Radial EC fans with very low power consumption at partial load and fluent air flow control Modern control and communication Specially designed evaporator uses 100 % of compressor power Remarkably high EER (3.4, in relation to inside air temperature of 35 C, and outside air temperature of 35 C) Communication protocols: ModBus, SNMP, etc. Suitable for open or closed hot and cold aisles, without need of a raised floor Shut-off valve on refrigerant piping for quick and easy maintenance Double high-pressure and low-pressure security facilities Electronic oil management system (TraxOil) provides oil level monitoring and active oil level balancing of compressor oil chamber to ensure the compressor safety Stainless-steel condensate pan located under the evaporator Water level sensor in condensate pan Solenoid valve prevents spontaneous refrigerant flow, allowing easy winter startup

Function The CoolTeg Plus XC40 is an air/refrigerant heat exchanger employing the direct evaporation principle, efficiently transferring the heat load of both servers and other IT devices to the ambient air. Compressed refrigerant vapor is moved to a condenser (located outside the data center), where it changes to a liquid, releasing its heat to the ambient air. Refrigerant then flows into an expansion valve, decreasing its pressure before evaporating (in indoor CoolTeg Plus unit) due to heat gains from the data center s hot air, whereby the compressor sucks up the evaporated refrigerant and the whole process begins again (circuit shown below). The indoor unit includes an expansion valve, evaporator and compressor. The external condenser is placed outside the building. Indoor unit Expansion valve Outdoor unit Evaporator Condenser Data center Air Ambient Air Liquid Gas Compressor Low pressure High pressure Pic. 1: Refrigerant circuit scheme Heat exchanger - evaporator The evaporator is constructed of copper tubing and aluminum fins for maximum effectiveness. Fin s hydrophilic surface keeps droplets of condensate on the heat exchanger s surface, so they drain into the pan. Compressor A highly effective scroll compressor equipped with BPM (Brushless Permanent Magnet) motor is integrated directly into each CoolTeg Plus XC40 unit. It compress refrigerant vapor and transport it throughout the refrigerant circuit. Compressor speed is driven by an inverter, maintaining requested cooling capacity within ranges of 20 100 %. The compressor is fixed by dampers (silent blocks) to avoid vibration transfer to the unit frame. Connection between the compressor and refrigerant piping is via anti-vibration joints. Expansion valve Operated by an actuator, the electronic expansion valve (or EEV) allows precise control of superheated refrigerant vapor. Refrigerant flow is controlled by needle stroke. The EEV changes its opening according to a pressure and temperature probe, located behind the evaporator. Due to high needle sensitivity, the operation remains economical even with fluctuating heat loads.

Condensate pan A stainless-steel condensate pan, positioned at the bottom of the unit, collects water, which then flows to the drainage piping. Condensate gathered on the cold surface of the heat exchanger flows down into the pan. The bottom of the pan is tilted. The lowest point ends by G 3/8" short pipe with an external thread for easy assembly of drainage hose. Water can be rejected by gravity drainage or (optionally) by a condensate pump. The unit is equipped with a standard water level sensor. Fans Fans transfer air through the air-conditioning unit from the hot zone to the cold zone. We use highly efficient radial fans with step-less speed controlled EC motors to maintain airflow according to the actual request. The control logic is based on the temperature or pressure difference between cold and hot zones. In case of pressure control accessory, the upper fan is controlled to keep proper airflow according to the IT devices request, two lower fans keep temperature difference. Total maximal airflow is 9 000 m 3 /h. Any failure is reported to the controller and signaled by LED lights. Filters Filters are installed for air filtration and internal component protection against intrusion of unwanted objects. The unit is equipped with three separate G4-class zick-zack filters, made of synthetic material in paper frames. They are fixed to the unit with brackets, allowing easy replacement and ecological incineration. Any clogging is detected by differential pressure switch and indicated on a display. Air side sensors Each unit is equipped with two temperature sensors on the suction side (up and down), two temperature sensors on the exhaust side (up and down), one relative humidity sensor on the suction side and one relative humidity sensor on the exhaust side. The controller evaluates the data being measured (maximum or weighted average), which changes both fan speed and compressor speeds. Refrigerant side sensors For proper refrigerant circuit operation, the unit is equipped with a wide range of pressure and temperature sensors located in the refrigerant circuit. Temperature and pressure sensors located behind the evaporator (on the low pressure side) provide information about the temperature and pressure of the superheated vapor. EEV is driven according to the evaluated superheating. A pressure sensor behind the compressor (on the high pressure side) sends a request to the controller, increasing or decreasing the condenser fan speed. The sensors mentioned above (along with the temperature sensor behind the compressor) also serve as safety sensors ensuring proper functioning of the compressor in the operation envelope, which keep EEV limits between LOP and MOP. In order to ensure maximum safety, the refrigerant circuit is fitted with two additional independent (low and high pressure) sensors, which shut down the entire unit if limits are exceeded. TraxOil sensor (on the refrigerant side) scans oil level in the compressor ensuring the correct amount of oil in the compressor. In case of small amount of oil in compressor, TraxOil ensures the oil transport from discharge to suction side.

Electro-box As the unit s control center, the electro-box ensures electrical power supply, functionality, control logic, safety and communication between grouped units. The electro-box contains a circuit breaker for the fans, one for the controller and another for the compressor. The condenser is not powered by the indoor unit. The controller (delivered with preinstalled Conteg software) manages all cooling unit functions. According to values set by the user, the controller changes both indoor and outdoor unit (condenser) fan speed, compressor speed, EEV opening and electronic accessories. Accessible from the rear side of the unit, the electro-box includes terminals for digital inputs and outputs (unit operation notification, warning, emergency OFF switch, remote unit operation authorization, external firefighting alarm, etc.), eventually along with a pressure control sensor. The main power switch is located on the front of the electro-box. Condenser The CoolTeg Plus XC40 is designed to be linked with a remote condenser, allowing selection and optimization directly according to climatic, spacing or acoustics requests. Ambient air temperature can reach up to 55 C (See the list of Recommended condensers). The condenser has to be equipped with a liquid receiver on site. Our CoolTool selection software can assist you in making the right choice. Alternatively, please contact our Cooling department for further information.

Unit connection Power supply The power supply cable must be connected with the terminals in the electro-box (housed within the indoor unit). The power supply must be: 3 phases; 400 V; 50/60 Hz; 25 A. Refrigerant piping connection Both indoor and outdoor units must be connected via copper refrigerant piping. This system uses ecological refrigerant R410A. The piping dimension at the liquid line is 22 mm, and 28 mm at the gas line. Maximum piping length is 60 m, with a maximum elevation of 20 m. If the condenser is under the unit, the maximum elevation is only 10 m. Maximum length and elevation must be strictly respected. Piping must be fitted with a siphon every 4 meters in height. Please contact our technicians for individual cases. Each unit s piping ends come equipped with ball valves, allowing refrigerant circuit closing for easy maintenance. Pic. 2: Ball valve

Connection diameters Top connection 880 Bottom connection 880 Piping distance >1% max. 20m gas liquid liquid >1% max. 10 m approx. 4m gas >1%

Condensate drainage Each unit must be positioned horizontally, and be connected to the drainage system. Condensate is removed by either gravity or condensate pump through the syphon (not included in delivery). The condensate tank outlet has a G 3/8 external thread (external diameter 18 mm). Combined temperature and humidity probe Condensate outlet Operation limits of indoor unit Air temperature from +4 C to +50 C Relative humidity from 10 % to 80 % The air passing through the unit must not contain aggressive or corrosive substances, or an excessive amount of solid particles.

Communication CoolTeg Plus XC40 units can communicate within individual zones. Each unit s electronic board includes two identical communication ports: COM1 and COM2 (RJ45 socket), allowing unit connection within a group. User can manage the units by 4.3 color touch-screen display, positioned in the front door, allowing the user to both switch-on and set its parameters. The unit can be also controlled by button (service) display. This kind of display can be connected to a port situated at the bottom of the electro-box. Wiring diagram series connection Each controller includes RS485 connector for easy BMS communication via ModBus RTU (a protocol allowing both continuously reliable and accurate remote control of the air-conditioning units) and a port for SNMP card (pco Web). Accessories Pressure Control This accessory enables fan speed control of the entire CoolTeg group, based on the pressure difference between hot and cold zones. Users can adjust the desired overpressure in cold zone. Lower overpressure means the ICT has increased airflow, so all connected units will automatically increase their upper fan speed to provide the required amount of air. The remaining two fans are controlled to keep perfect conditions of refrigerant circuit. It is recommended that CoolTeg Plus units retain a slight overpressure (2 Pa) in cold zone. Pressure control ensures the correct pressure (generated by CoolTeg Plus fans on the servers) in contained cold/hot aisles. This solution extends server lifetime and reduces power consumption. Condensate pump The condensate pump is positioned at the rear side of the unit (above the condensate pan) and bracketed to the frame, with a suction pipe situated in the lowest part of the condensate pan. If the condensate sensor detects water, the pump switches on and pumps water toward the drainage pipes. SNMP Communication card (pco Web) Designed for direct unit connection to (LAN) data networks, the card supports real-time unit monitoring via standard web browser (WEB server) or SNMP. The extending card is intended for communication via TCP/IP protocol, allowing monitoring via web server, Modbus TCP or BACnet. Humidifier Steam humidifier keeps required relative humidity in the data center. Maximum steam production capacity is 3 kg per hour and is driven by PID controller in range of 20 to 100%. Humidifier produces pressure-less water steam by electrodes placed in water cylinder and distributes the steam to the air behind heat exchanger. Humidifier is powered separately by 230 V, 50 Hz, 9.8 A (2.25 kw). For power connection, use cable 3x1.5 mm 2 with C14 terminal.

Control function Each CoolTeg Plus unit has an independent programmable PID controller (housed in the electro-box) which changes fan speed (airflow), compressor speed (amount of refrigerant) and expansion valve opening (refrigerant overheat) while driving the electronic accessories. Controller also evaluates measured values from temperature, humidity and pressure probes. Temperature set-point in cold zone User can adjust air temperature set-point of the cold zone. The compressor changes speed according to the difference between required and actual air temperature, measured in the cold zone. Refrigerant evaporation temperature can be set using the service menu. Admin can also set the compressor s working range from 20 up to 100 %. Set point - pressure difference We recommend using a fan speed control based on the pressure difference for projects with perfectly mechanically separated hot and cold zones. The upper fan of CoolTeg Plus unit changes speed to keep the set pressure difference between hot and cold zones, while the other two fans keep the set temperature difference. Users can select an overpressure ranging from -10 to +10 Pa, as well as limitations for maximal and minimal fan speeds. As the controller does not include a differential pressure meter, an additional accessory is necessary for this function, the aim of which is to keep balanced airflow within the entire system (cooling units and IT devices), thus avoiding long-term server degradation due to under- or overpressure. Set point - temperature difference Fans change speed to ensure optimal temperature difference between hot and cold zone, the aim of which is to keep balanced airflow within entire system (cooling units and IT devices). User can set the required temperature difference and limits for maximal and minimal fan speeds. We recommend this approach for projects without mechanical separation of hot and cold zones, where pressure difference measurement is impossible. User selects the logic by which the unit will be driven (temperature difference or pressure difference). Communication Each unit can be equipped with 4.3 color touch-screen display, positioned at the unit s front door. One display can control up to 16 units in one zone. The display includes an USB port and two Ethernet ports, allowing remote control and monitoring via building management system. The USB port is used mainly for simple software update and historical data downloads. Zone functions (such as standby management and overload start) are also available. Each display includes a web-server, supporting access via IP address. Communication functions via TCP/IP protocol, allowing remote access. Up to 16 units can be connected to form a group, communicating via plan protocol. Units are connected via straight-through network cable (ports COM1 and COM2), controlling the group from a single unit display. Set-point sharing is also possible. In addition to the (SNMP) extension cards mentioned above, which can be installed in each controller and allow supervision via superior system, the unit is equipped with dry contacts for basic status signalization (ON/warning/emergency OFF). The unit comes prepared for basic input connection, such as operation permit or external fire alarm.

Technical data CoolTeg Plus XC40 Unit type Outdoor unit Basic information Cooling system Architecture (1) CoolTegXC40 AC-TXC-42-40... AC-CONDx-xx-xx/EcoCool Direct expansion Open or closed Nominal cooling capacity (2) kw 42,2 Nominal net cooling capacity (3) kw 39,1 Power supply V/f/Hz 400 / 3 / 50 Fan power consumption (max) kw 3,1 Compressor power consumption (max) kw 12,3 Nominal current (4) A 22,7 Maximum current (5) A 25,3 Circuit breaker (6) A 0,5+6+25 Recommended superior circuit breaker A 32 Nominal airflow (7) m 3 /h 9 000 Number of radial fans pcs 3 Fans motor type - EC Air filter class - G4 Dimensions Height mm (U) 1978 (42U), 2111 (45U), 2245 (48U) Width mm 400 Depth mm 1000 or 1200 Weight depth 1000 mm, height 42/45/48U kg 262/270/278 Weight depth 1200 mm, height 42/45/48U kg 274/284/294 Piping connection dimensions Piping connection dimension - liquid mm 16 Piping connection dimension - gas mm 22 Maximum piping length m 60 Max. piping elevation (unit under condenser) m 20 Max. piping elevation (unit above condenser) m 10 Notes (1) CoolTeg Plus units can be used either independently (in rack rows) or integrated in a Modular closed loop system (MCL) = a closed-architecture system of racks and air-conditioning units. Unit type is determined by a key. (2) Cooling capacity is changed by the controller according to actual request. Nominal cooling capacity is calculated at 35 C without condensation (air humidity below dew point), evaporating refrigerant temperature of 10 C, a condensing temperature of 45 C and clean filters. (3) Net cooling capacity is the total capacity reduced by fan heat load, which is the available cooling capacity of the unit. (4) Nominal current: fans 4.6 A, compressor 17.8 A, controller 0.3 A (5) Maximum current: fans 4.8 A, compressor 20.2 A, controller 0.3 A (6) Circuit breakers: fans 3-C6 (400V/6A), compressor 3-C25 (400V/25A), controller 1-B0.5 (230V/0.5A). Main switch is dimensioned at 32 A. Recommended superior circuit breaker must be minimally 32 A as well. (7) Airflow is automatically changed by controller; the nominal airflow matches the nominal cooling capacity.

Cooling capacity diagram Airflow, power consumption and cooling capacity ratio 10000 3500 Airflow m 3 /h] 9000 8000 7000 6000 5000 4000 3000 2000 1000 Airflow Power consum. 3000 2500 2000 1500 1000 500 Fans power consumption [W] 0 0 5 10 15 20 25 30 35 40 45 0 Net cooling capacity [kw] Relationship between cooling capacity, evaporation temperature and air temperature in hot zone 50 Cooling capacity [kw] 40 30 20 Evaporation temperature [ C] 4 6 8 10 10 0 25 30 35 40 Hot zone air temperature [ C]

3D model 1978, 2111, 2245 mm (42U, 45U, 48U)

Recommended condensers Outdoor air-cooled condensers transfer data center heat load into ambient environment. Total condenser cooling capacity corresponds with the sum of the CoolTeg Plus XC40 cooling capacity and its compressor power consumption. The indoor unit is designed to cooperate with the widest field of air-cooled condensers. Customers can choose the condenser to perfectly match their requirements. To ensure proper operation, the condenser must contain fans with continuous speed control. The indoor unit evaluates needed cooling capacity and sends a signal (0-10 V) to increase or decrease condenser fan speed. The CoolTeg Plus XC40 contains operating permission control of condenser. The table below shows the recommended condenser types which cooperate with CoolTeg Plus XC40. They are sorted by maximum ambient air temperature. Plumbing company has to deliver liquid receiver in proper size for the current ambient conditions. Liquid receiver is not a standard part of air-cooled condensers. Air-cooled condensers fins and tube Dimensions Max. temp. Conteg P/N Length Width Height Weight 35 C AC-COND2-35 1,9 m 0,8 m 1,0 m 153 kg 45 C AC-COND2-45 2,5 m 1,1 m 1,0 m 218 kg 55 C AC-COND2-55 2,8 m 0,9 m 1,0 m 204 kg Sound power level and Sound pressure level in 10 m Max. temp. Conteg P/N Lw(A) Lp(A) 10m 35 C AC-COND2-35 81 db 50 db 45 C AC-COND2-45 82 db 50 db 55 C AC-COND2-55 74 db 43 db Electrical data Max. temp. Conteg P/N Fans f/v/hz A kw 35 C AC-COND2-35 2 3/400/50-60 0,85 1,05 45 C AC-COND2-45 2 3/400/50-60 0,85 0,98 55 C AC-COND2-55 3 3/400/50-60 0,80 1,44 L B H1 H L2 ØD L1 B2 B1

Air-cooled condensers micro channel Dimensions Max. temp. Conteg P/N Length Width Height Weight 35 C AC-COND3-35 2,4 m 1,1 m 1,0 m 152 kg 45 C AC-COND3-45 2,4 m 1,1 m 1,0 m 174 kg 55 C AC-COND3-55 3,6 m 1,1 m 1,0 m 210 kg Sound power level and Sound pressure level in 10 m Max. temp. Conteg P/N Lw(A) Lp(A) 10m 35 C AC-COND3-35 72 db 40 db 45 C AC-COND3-45 81 db 49 db 55 C AC-COND3-55 74 db 42 db Electrical data Max. temp. Conteg P/N Fans f/v/hz A kw 35 C AC-COND3-35 2 3/400/50-60 0,92 1,05 45 C AC-COND3-45 2 3/400/50-60 1,43 1,93 55 C AC-COND3-55 3 3/400/50-60 0,68 1,09 L B H1 H L2 ØD L1 B2 B1