CHIMNEY INSTALLATION. Technical Bulletin #1

Similar documents
CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS

CHIMNEYS AND VENTS CHAPTER 8

Hitzer Energy Master II Stoker Furnace Model 710 Owner s Manual Installation and Operation

2012 INTERNATIONAL FUEL GAS CODE VENTS

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Venting of Gas Fired Equipment RV

Do not use this vent pipe or fittings for venting incinerators of any kind.

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

VENTING GAS APPLIANCES NFPA 54 CODE

Pellet Vent INSTALLATION INSTRUCTIONS

Model 1200G. SOLID FUEL WARM AIR FURNACE Owners Manual

SOLID FUEL WARM AIR FURNACE

ASX7-4-IOM-6 J

Home Performance Science

INSTALLATION AND SERVICE MANUAL

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

SCOTTY WOOD FURNACE Model DB-102 OWNER S MANUAL IMPORTANT

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

SOLID FUEL WARM AIR FURNACE

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

ASX7-5-IOM-3 J

Inspection Checklist Mechanical Rough in

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

TANKLESS WATER HEATING

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

M MMG Insurance Company Presents A Guide for Woodburning Safety

SOLID FUEL WARM AIR FURNACE

INSTALLATION AND SERVICE MANUAL

SOLID FUEL WARM AIR FURNACE

Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below)

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

Mechanical Appliance and Equipment Inspection Checklist

HVAC Equipment Access Equipment Location

104 MK II WOOD-BURNING STOVE

OWNERS MANUAL Models 2941, B2941, 2941B, B2941B WONDERWOOD THERMOSTAT CONTROLLED WOOD BURNING CIRCULATOR HOW TO ORDER REPAIR PARTS

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

INSTALLATION INSTRUCTIONS

1. Categorizing Appliances

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

INSTALLATION INSTRUCTIONS SL280UHNV

Econoburn Technical Datasheet

OWNERS MANUAL LIBERATOR ROCKET HEATER Model: RMH-1

Uniform Dwelling Code 2017 Updates SPS 323

Objectives. Home Performance Diagnostics with the House of Pressure (Part 1) How can Pressure effect Building Performance?

The Heating System and Ventilation and Combustion Air

Installation Manual Installation & Appliance Set-Up

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

2015 MECHANICAL CODE REQUIREMENTS

INSTALLATION INSTRUCTIONS

Installation & Maintenance Instructions

Indiana WX Oil Furnace Inspection Guide

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Introduction Engineering and Design Manual

Installation Manual Installation & Appliance Set-Up

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

tççç= ÜÉ~íáåÖ çéíáçåë

H530. Installation and user manual. - Please read this manual carefully and save the instructions - Version: 10/09. Tested and Listed by:

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Installation Manual Installation & Appliance Set-Up

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

Model 1537Q. SOLID FUEL WARM AIR FURNACE Owners Manual

St. Croix Greenfield Installation Manual

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

SUPER JACK/ BIG JACK OWNER S MANUAL. Model No. s BJ90 - SJ125. Assembly Installation Operation Repair Parts SUPER JACK SJ125 BIG JACK BJ90

Direct Vent System Required

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Vented Room Heaters ENCLOSED MODEL FIREPLACE MODEL. Williams Furnace Co. 250 West Laurel Street Colton, California U.S.A.

COMBUSTION SAFETY BASICS

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

MP80 INSTALLATION AND OPERATION MANUAL

RS Chimney Fan for Solid Fuel Applications

INSTALLATION INSTRUCTIONS G60UH(X) Series

Gas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING

Corn Flame Energy Corn Stove Model 3000

INSTALLATION INSTRUCTIONS EL280DF

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS EL280DF

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

Before selecting your wood heater, it is very important that you clearly identify what your needs are:

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

INSTALLATION INSTRUCTIONS G50UH(X) Series

INSTALLATION INSTRUCTIONS EL280UH

RS Chimney Fan for Solid Fuel Applications

AHearth Products. COAL BURNING CIRCULATOR HEATER MODELS CAC/BCAC Installation, Operation and Maintenance Instructions COAL ONLY STOVE

Transcription:

Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe the suction that occurs when hot air rises and creates a vacuum in the firebox. That vacuum draws fresh air into the firebox and feeds combustion of the wood. No furnace can operate properly without adequate draft. IMPORTANT NOTE: The Sedore 3000 requires draft measuring between.05 and.07 WC (water column) (12.45 17.44 Pascals), measured with a manometer or similar device. Draft less than.05 will starve the fire of oxygen and cause it to burn dirty (i.e., produce smoke and creosote). Draft more than.07 will feed too much oxygen to the fire, causing it to over-fire and burn at less than optimum efficiency. IMPORTANT NOTE: The following instructions are guidelines only. A qualified HVAC contractor should determine the specific chimney requirements for your stove/furnace installation and insure that it complies with local building codes and ordinances. Flue Size The chimney flue is a vital part of your stove/furnace installation. A properly built and maintained chimney or factory-built flue will assure a consistent draft under a variety of weather conditions. IMPORTANT NOTE: The stove/furnace must connect to a code-approved chimney with a flue liner or an appropriately sized factory-built chimney, which complies with requirements for Type HT, all fuel chimneys in the standard UL 103 or CAN/ULC-S629. Flue Diameter The outlet collar on the Sedore 3000 is 6 inches, internally. For the Sedore 3000 a flue reducer/increaser may be required to connect the 6 -inch outlet collar to the appropriately sized connector pipe. Stove Sedore 3000 in Flue Diameter 6 inches (150mm) Flue Height The flue must be tall enough to draw, which typically means at least 15 feet tall, or more (3.66m) [Note: Add one foot (0.3m) to this minimum for each 1000 feet above sea level]. If you cannot control the height of the flue, it may be necessary to install a draft inducer fan (see Measuring and Adjusting the Draft later in this section). Sedore USA Page 1 of 7

Connecting to an Existing Chimney Flue You may connect the Sedore stove/furnace to an existing flue or chimney subject to the following conditions. 1. A qualified professional has inspected, repaired (if necessary), thoroughly cleaned the chimney and determined it is suitable for use with a residential heating appliance that burns solid fuel. 2. If possible, avoid using exterior chimneys (i.e., a chimney with one or more walls exposed to the outside below the roofline). If it is necessary to use an exterior chimney, the chimney flue size area must not exceed the minimum flue area for the furnace. Model Sedore 3000 Min Flue Max Flue Area Max Flue Area Diameter Internal Chimney External Chimney 6 inches (15 cm) 85 in 2 (177 cm 2 ) 56 in 2 (116 cm 2 ) 3. If your chimney flue exceeds the maximum area allowed, it must be lined with a suitable flue liner that complies with the requirements of Chapter 11 of NFPA 211 3-1.2 -- Standards for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances. 4. The chimney or flue should be at least 15 feet tall and sized correctly for the Sedore 3000 5. Do not share a flue with another furnace, appliance or fireplace. Do not use a flue that already provides make-up air to the cellar or basement. 6. Tightly close the cleanout opening in the base of the chimney. Connector Flue Pipe The connection between the Sedore 3000 and the chimney must be at least 24-gauge stovepipe. (not included). Maintain a clearance of at least 12 inches between the connector and combustible surfaces as shown on the following illustration. Sedore USA Page 2 of 7

NOTE: Installation of the Sedore 3000 must comply with the latest edition of NFPA 211 for reduced clearances and/or your local building code rulings -- use whichever minimum dimensions are LARGEST. Observe the following rules when installing the connector pipe. 1. Where possible, use only corrugated (non-adjustable) elbows. These are more airtight and less likely to break. Use 90-degree elbows only as required and never more than two (they reduce the draft of the chimney). 2. Make sure all horizontal runs of connector pipe have a minimum outward rise of 1/4 per horizontal foot (this allows any condensation or creosote buildup to drain back toward the furnace). 3. If the connector stovepipe must go through a combustible wall before entering the masonry chimney, consult a qualified mason or chimney dealer. The installation must conform to local building and fire codes and latest edition of NFPA 211. 4. Insert the crimped end of the stovepipe inside the stove/furnace outlet collar. Install additional pipe and elbows with the crimped end towards the furnace. This will allow any condensation in the flue to run back into the furnace. 5. Seal the connector pipe to the chimney with furnace cement. 6. Securely support the connector pipe and fasten joints with a minimum of three sheet metal screws or rivets per joint. 7. In all cases, follow the chimney manufacturer s instructions for installation. When attaching the connector pipe to the chimney, do not push it into the chimney (it may plug the chimney and impede the draft). The following illustration shows proper installation. Installation of the Connector Pipe into an Existing Chimney Sedore USA Page 3 of 7

Using a New Factory-made Chimney A properly sized and installed chimney flue will ensure adequate draft at all times for optimum performance of the stove/furnace. For a new chimney, use an insulated stainless steel system that conforms to type HT (High Temperature) requirements of UL 103 and ULC S629 and complies with the requirements of Chapter 11 of NFPA 211, Standard for Chimneys, Fireplaces, Vents and Solid Fuel- Burning Appliances. The chimney must be at least 12-15 feet tall (add 1 foot for each 1000 feet above sea level) and correctly sized for the Sedore Stove/Furnace model installed. Model Sedore 3000 Min Flue Diameter 6 inches (15 cm) When installing a new chimney flue, be sure to observe local building codes and the National Fire Protection Association rule: The top of the chimney must extend at least 3.0 feet (0.9m) above the highest point where it exits the roof and be at least 2.0 feet (0.6m) taller than any point of the roof within 10.0 feet (3.04m). Sedore USA Page 4 of 7

Supplying Make-up Air Fireplaces, other furnaces, clothes dryers, exhaust fans, and other appliances, all draw air from the room in which they are located. The Sedore 3000 adds to that draw, and so it is important to make sure there is an adequate source of fresh air to offset these demands. Otherwise, you may create negative pressure in the room and starve combustion in the furnace. 1. Determine the volume of space (cubic feet) in the room. Include in the calculation adjacent rooms and areas not closed-off by doors. Volume (CF) = Length (ft) x Width (ft) x Height (ft) 2. Determine the air input requirements of all appliances in the space. Add them and round the total to the nearest 1000 BTU per hour. 3. Determine whether the space is confined or unconfined by dividing the total volume of the room by the total input requirement for all appliances in the room. a. If the result is greater than or equal to 50 CF/1000 BTU per hour, then consider the space unconfined. b. If the result is less that 50 CF/1000 BTU per hour, then consider the space confined. 4. For an unconfined space in a conventionally constructed building, the fresh air infiltration through cracks around windows and doors NORMALLY provides adequate air for combustion and ventilation, and so no additional make-up air is required. 5. For a confined space or an unconfined space in a building with unusually tight construction, an additional source of make-up is required. Please consult an HVAC professional to determine the best way to supply make-up air for your installation. Measuring and Adjusting the Draft of the Flue Draft is a function of the chimney flue, not the furnace. The natural draft generated through a chimney is dependent on several factors including chimney height, temperature of flue gases, cross-sectional area of the chimney, chimney wall insulation value, dilution air, and total volume of flue gases. To operate properly, the Sedore 3000 requires a draft of.05 to.07 WC (water column) (12.45 17.44 Pa). Symptoms of an improperly designed or installed flue include visible smoke out the chimney, smoke escaping into the room, creosote buildup in the flue, and/or poor heating performance. The following procedure describes how to measure draft using a manometer. (You can usually rent a manometer from a local stove and hearth retailer or local equipment rental shop.) Sedore USA Page 5 of 7

1. Close all windows and doors in the building and turn on all appliances that remove air from the home (e.g., heat pump, air conditioner, exhaust fan, clothes dryer, fireplaces, etc.). 2. Drill a hole in the connector pipe (just large enough for the tube of the manometer) at least 1 foot above the furnace outlet collar. 3. After all chimney connections are made, build a fire and allow the furnace to settle into stable operation (20-25 minutes). 4. Using the manometer, measure the draft in the flue. a. If the draft measurement is below.05 WC (12.45 Pa), there is too little draft and a draft inducer or other corrective measures are required to avoid air-starvation of the furnace. A draft inducer fan (see picture) mounts in the connector duct and adjusts to increase the draft of the flue. These devices can be purchased on-line or at a local HVAC supply center. b. If the draft measurement is above.07 WC (17.44 Pa), there is too much draft and a barometric damper is need to avoid over-firing of the furnace. This device (see picture) also mounts in the connector duct and adjusts to reduce the draft. 5. Once needed adjustments are complete, seal the hole made for the manometer tube with furnace cement or a screw. IMPORTANT NOTE: To avoid over-firing the furnace, do not set a draft inducer fan to pull a draft of more than.07 WC (17.44 Pa). Draft Inducer Fan (Model AD-1) (Available on-line or at a local HVAC supply center) Sedore USA Page 6 of 7

Other References More Information 1. Chimney Safety Institute of America (www.csia.org) 2. All About Chimneys (www.chimneys.com) 3. National Fire Protection Association (www.nfpa.org) 4. American Society of Mechanical Engineers (www.asme.org) Sources of Equipment* 1. Chimney flue components: local building supply store or http://www.ventingsystems.com 2. Draft Inducer (Model AD-1): local building supply store or http://www.draftinducers.com/index.htm 3. Other Chimney products: http://www.chimneys.com/index.html and http://www.jacksonsystems.com *Note Sedore USA provides these supplier references for your convenience only. We do not endorse the vendor, the equipment they sell, or their prices. Other suppliers may offer similar or identical components and we encourage you to comparison shop. Sedore USA Page 7 of 7