VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

Similar documents
VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Expansion Modules & Accessories

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

If you want to. grow your business expand your. expectations.

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

&RPPHU LDO)LUHDQG%XUJODU\

VISTA-128B. Installation and Setup Guide. Commercial Burglary. Partitioned Security System. with Scheduling K3271 7/98

Vista-128FB System Design Sheet

&RPPHUFLDO)LUHDQG%XUJODU\

VISTA-128FB. Installation and Setup Guide. Commercial Fire & Burglary Partitioned Security System with Scheduling

Commercial Fire and Burglary Partitioned Security System with Scheduling

DS7400Xi Addressable Control/ Communicator

Vista-50P/-50PUL System Design Sheet

Honeywell Combination Fire & Burglary Control Panel

&RPPHUFLDO%XUJODU\ ,QVWDOODWLRQDQG6HWXS*XLGH 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 3 STAY 1 OFF 6BYPASS 5 TEST 4 MAX 9 CHIME 7 INSTANT OFF 2 AWAY

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

VISTA-100. COMMERCIAL FIRE AND BURGLARY PARTITIONED SECURITY SYSTEM with SCHEDULING. INSTALLATION INSTRUCTIONS and PROGRAMMING GUIDE N6019-2V1 1/98

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Commercial Burglary Partitioned Security System With Scheduling. Installation and Setup Guide. N5944-6V2 5/04 Rev B

V2 1/13 Rev C

P Zone Expandable Hybrid Security System

EVO192 v3.0 Fire and Burglary What s New

Vista-10SE System Design Sheet

Vista-20SEUL System Design Sheet

VISTA-100 Commercial Fire & Burglary Partitioned System

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Installation Guide. Control/Communicator

Integrated Solutions. Integrated Solutions HONEYWELL SECURITY & COMMUNICATIONS. More and more, customer requirements cannot

Addressable Fire Alarm Control Panel

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

OmniPro II. Technical Sheet. DESCRIPTION

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

WIRELESS CONTROLS & DETECTORS

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Security & Communications INTRUSION AND ALARM COMMUNICATIONS

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

VISTA-40. Installation and Setup Guide. 2-Partition Security System N7001V4 7/98

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

VISTA-50P VISTA-50PUL

ADEMCO VISTA SERIES VISTA-21iP / VISTA-21iPSIA Security Systems

9,67$36HULHV 6HFXULW\6\VWHPV ,QVWDOODWLRQDQG6HW8S*XLGH. The formatting of this version has been significantly revised. K5305-1V3 10/03 Rev.

D2412 Control / Communicator Installation Manual

9,67$&1 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH K3892V1 4/00

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

First Alert 1200C Installer Notes M. Leuck

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ADEMCO CONTACT ID REPORTING (revised )

good things in small packages

System Overview. PC4020 v3.3

Model 17A00 Expansion Enclosure

Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Integrated Security Solutions

Installation Manual Premier 412/816/832. Issue 10

AL800ULADA. NAC Power Extender. Installation Guide

SECTION INTRUSION DETECTION SYSTEM

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

VISTA-20SE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM.

&RPPHUFLDO)LUHDQG%XUJODU\ 6HFXULW\6\VWHP ZLWK6FKHGXOLQJ ,QVWDOODWLRQDQG6HWXS*XLGH 35(/,0,1$5< -8/< K3822V2 6/01

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

DOOR MONITORING/DURESS SYSTEM

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Integrated Security Solutions

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

VISTA-128FB. Quick Start Guide. Commercial Fire & Burglary Partitioned Security System. with Scheduling.

Installation Instructions

RE6100 Series Helix Security and Automation Platform

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

/<1; 6HFXULW\6\VWHP ,QVWDOODWLRQDQG6HWXS*XLGH N8889V1 10/98 OFF AWAY STAY AUX

FA130CP. Installation and Set-Up Guide. K0735-1V1 4/04 Rev. A OFF FA260 3 STAY 2 AWAY 1 OFF 6 9 CHIME # 5 TEST 8 CODE B C # FA560 READY R BYPASS MAX

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

VISTA-20HWSE INSTALLATION INSTRUCTIONS 2-PARTITIONED SECURITY SYSTEM

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Control/Communicator

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

LYNX ,QVWDOODWLRQ,QVWUXFWLRQV. ALPHA DRAFT. June 5, 1998 N8889 5/98 OFF AWAY STAY AUX

Contact ID as of 11/28/2018

D7212 Control/Communicator Operation and Installation Manual

AL600ULADA. NAC Power Extender. Installation Guide

Control/Communicator Installation Manual

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

SENTROL ZX200/ZX210. Security System Control. Installation/ Programming

Transcription:

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with, access control, and ADEMCO s full range of fire and burglary components, the NEW VISTA-128FBP provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions, and supports up to 128 zones/points using hardwired, wireless and V-Plex addressable technologies. A diverse line of ADEMCO keypads, RF receivers and relays are supported by extremely powerful control platform. The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. A revolutionary new feature called allows multiple partitions, panels even buildings to be armed, disarmed and have status checked from one location. initiating devices, notification circuits, digital dialers, FEATURES Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones Can control eight separate areas independently (8 partitions) Supports Panel-Linking allows up to 8 systems or buildings to be controlled from one central location (using VA8200) Supports commercial UL wireless fire and burg Stores up to 512 events and can accommodate 150 user codes Supports addressable V-Plex access control points using VistaKey (1 to 8 doors) Supports up to 16 doors of access control using Vista Gateway (VGM)* Supports applications with the new VistaView-100 Switcher Identifies the point or zone of a fire or alarm, using the new FSA- 8/FSA-24 Fire System Annunciator Programmable to meet SIA false alarm prevention specifications. To meet UL approval foransi/sia CP-01-2000 order part number VISTA-128SIA Two on-board notification (bell) circuits delivering 2.3 amp @ 12V or 3.4 amp @ 24V Automatic smoke detector sensitivity maintenance testing 4-wire smoke reset using onboard J2 output trigger Supports Dynamic Signaling for LRR Supports Remote Control-via the internet** Supports Internet Alarm Reporting** Supports the new Graphical User Interface Consoles Supports up to 250 access card holders using VistaKey Supports AlphaNumeric pager up to 8 different numbers using the VA8201 * Connects to Northern Computers Passpoint Systems. Maximum 32 doors. ** When used with AlarmNet-i

Additional Features Notification Appliance Circuits (two): Programmable Temporal code compliant Individually silenceable Programmable on-board auxiliary relay SIA false alarm reduction features: Exit error logic Exit delay reset Cross zoning Call waiting defeat Recent close report Supports commercial hardwired, addressable V-Plex polling loop and wireless zones Hardwired zones Provides eight style B hardwired zones EOLR supervised for Fire and UL burglary installations Supports N.O or N.C. sensors Individually assignable to any eight partition Up to 32 two-wire smoke each on zone one and two (64 total) Up to 50 two-wire glass break on zone eight Patented addressable V-Plex polling loop technology Supports 120 two-wire zones points Global polling technology for faster processing Increased current draw capacity (128mA) Supervised by panel Individually assignable to partitions, notification circuit (bell) output or aux relay 4,000 ft capability without the use of shielded cable Extender/Isolation bus module Two-wire smoke detector zone/group expansion module adds two or four zones Eight zone Class A and B extender module Eight zone Class B extender module One zone supervised contact monitor module UL Listed wireless expansion Supports up to 128 wireless zones/points using ENHC receiver Supervised by control for check-in signals Tamper protection for transmitters Individually assignable up to eight partitions Supports UL864/NFPA approved wireless smoke integration Full integration with PassPoint System Complete Gateway interface of Vista and access functions Up to 8 doors using VistaKey V-Plex Event reporting Local printer of access or VISTA related event Scheduled uploading of events to Stored events for one call retrieval Communication Phone mapping by zone response type Supports VIP interactive phone voice module Panel operation during download Uploading equipment list to Communication to PassPoint via Vista Gateway integration Supports VistaView-100 ECP based switchers Series 4208U V-PLEX Loop Series Wireless Receiver 4208SNF With 2 Class A Zones 6160CR Red Alpha Console VistaView-100 Switcher VistaKey V-Plex 4204 Relay NAC (Bell) Circuit 4204CF Eight Class B Hardware Zones Parallel Printer 416 Key Switch Option 5140 LED Communicator Status Serial Printer 4100SM Printer Interface RS232 6220S Printer Alpha Paging Phone Line to Central Station 7720ULF Long Range Radio 7835CF Cellular Radio

Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical Primary power: 18VAC @ 72VA ADEMCO No. 1451 Control panel quiescent current draw: 350mA Backup battery: 12VDC, 12AH min to 34.4AH Lead acid battery (gel type) Alarm power: 12VDC, 1.7A for each notification (bell) circuit output Total 2.3amps @ 12V Aux. standby pwr: 12VDC, 1A Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources Standby time: 24 hours with 1A standby load using 34.4AH battery Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Optional 24-volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsmain Dialer: Line seize: Double Pole Ringer equiv.: 0.7B Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Dual phone line capability (using 5140DLM module) Cabinet dimensions 18 H X 14.5 W X 4.3 D Environmental Storage temp: -10 C to 70 C Operating temp: 0 C to 50 C Humidity: 85% RH EMI: Meets or exceeds the following requirements: FCC Part 15, Class B Device FCC Part 68 IEC EMC Directive Agency Listings Burglary UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault UL611/1610 Grades A, AA, Central Station UL365 Grades A, AA Police Connect Fire UL864/NFPA72 Local, Central Station and Remote Station Factory Mutual California State Fire Marshal MEA UL985 5140MPS - 1* 5140MPS - 2* ECP Bus Wireless Receiver (Max Two) V-Plex Two-Zone Expander 4293SN V-Plex Adapter 4944SN Addressable Recessed Mount Contact Tamper Switch* Flow Switch* Low Temp Switch* Symphony 6139R 32 Character Red-Alpha Keypad 4204CF Supervised NAC Notification Appliance 5816 Door/Window Miniature 5890 Wireless PIR 4209U Group Zoning Supports Up To 16 4297 Isolation/ Extender V-Plex Two-Zone expander PassPoint Supports Up To 64 VGM (PTVGM) Vista Gateway

Additional Features Notification Appliance Circuits (two): Programmable Temporal code compliant Individually silenceable Programmable on-board auxiliary relay SIA false alarm reduction features: Exit error logic Exit delay reset Cross zoning Call waiting defeat Recent close report Supports commercial hardwired, addressable V-Plex polling loop and wireless zones Hardwired zones Provides eight style B hardwired zones EOLR supervised for Fire and UL burglary installations Supports N.O or N.C. sensors Individually assignable to any eight partition Up to 32 two-wire smoke each on zone one and two (64 total) Up to 50 two-wire glass break on zone eight Patented addressable V-Plex polling loop technology Supports 120 two-wire zones points Global polling technology for faster processing Increased current draw capacity (128mA) Supervised by panel Individually assignable to partitions, notification circuit (bell) output or aux relay 4,000 ft capability without the use of shielded cable Extender/Isolation bus module Two-wire smoke detector zone/group expansion module adds two or four zones Eight zone Class A and B extender module Eight zone Class B extender module One zone supervised contact monitor module UL Listed wireless expansion Supports up to 128 wireless zones/points using ENHC receiver Supervised by control for check-in signals Tamper protection for transmitters Individually assignable up to eight partitions Supports UL864/NFPA approved wireless smoke integration Full integration with PassPoint System Complete Gateway interface of Vista and access functions Up to 8 doors using VistaKey V-Plex Event reporting Local printer of access or VISTA related event Scheduled uploading of events to Stored events for one call retrieval Communication Phone mapping by zone response type Supports VIP interactive phone voice module Panel operation during download Uploading equipment list to Communication to PassPoint via Vista Gateway integration Supports VistaView-100 ECP based switchers Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. A diverse line of ADEMCO initiating devices supports this extremely powerful control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Installation The VISTA-128FBP alarm system has been designed to mount both quickly and easily. It meets all applicable requirements for UL commercial fire and burglary installations. Specifications Electrical Primary power: 18VAC @ 72VA ADEMCO No. 1451 Control panel quiescent current draw: 350mA Backup battery: 12VDC, 12AH min to 34.4AH Lead acid battery (gel type) Alarm power: 12VDC, 1.7A for each notification (bell) circuit output Total 2.3amps @ 12V Aux. standby pwr: 12VDC, 1A Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources Standby time: 24 hours with 1A standby load using 34.4AH battery Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Optional 24-volt power supply, PS 24 Supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputsmain Dialer: Line seize: Double Pole Ringer equiv.: 0.7B Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Dual phone line capability (using 5140DLM module) Cabinet dimensions 18 H X 14.5 W X 4.3 D Environmental Storage temp: -10 C to 70 C Operating temp: 0 C to 50 C Humidity: 85% RH EMI: Meets or exceeds the following requirements: FCC Part 15, Class B Device FCC Part 68 IEC EMC Directive Agency Listings Burglary UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault UL611/1610 Grades A, AA, Central Station UL365 Grades A, AA Police Connect Fire UL864/NFPA72 Local, Central Station and Remote Station Factory Mutual California State Fire Marshal MEA UL985 5140MPS - 1* 5140MPS - 2* Series 4208U V-PLEX Loop Series Wireless Receiver 4208SNF With 2 Class A Zones ECP Bus Wireless Receiver (Max Two) V-Plex Two-Zone Expander 4293SN V-Plex Adapter 4944SN Addressable Recessed Mount Contact Tamper Switch* Flow Switch* Low Temp Switch* VistaKey V-Plex 4204 Relay 6160CR Red Alpha Console Eight Class B Hardware Zones NAC (Bell) Circuit 4204CF VistaView-100 Switcher Symphony 6139R 32 Character Red-Alpha Keypad 4204CF Supervised NAC Notification Appliance 5816 Door/Window Miniature 5890 Wireless PIR 4209U Group Zoning Supports Up To 16 4297 Isolation/ Extender V-Plex Two-Zone expander Parallel Printer 416 Key Switch Option 5140 LED Communicator Status PassPoint Serial Printer RS232 4100SM Printer Interface 6220S Printer Supports Up To 64 VGM (PTVGM) Vista Gateway Alpha Paging Phone Line to Central Station 7720ULF Long Range Radio 7835CF Cellular Radio

SPECIFICATIONS Auxiliary Devices 6160CR Red Alpha Keypad 6139R Red Alpha Keypad/Annunciator FSA-8 & FSA-24 annunciator modules 4204 Relay, four form C contacts 4204CF Two supervised output circuits Series RF receiver supporting 5800 wireless 6220S System printer used with 4100SM serial module Two-wire smoke conventional 2100 Series Photoelectric 2400 Series Photoelectric 1100 Series Ionization Four-wire smoke conventional 2112/24 Series Photoelectric 1412 Series Ionization Horn/Strobes System Sensor Notification Appliances 5140MPS-1 5140MPS-2 V-Plex (addressable) Devices 4208U Loop eight zones 4101SN Single Relay/Zone 4208SNF Class A/B Expander 4209U Group Zoning two/four zones Remote Point two zones Two Zone 4293SN One Zone 4297 Isolation/Extender V-Plex (addressable) : SD 4192SD 4192CP SDT 4192SDT 4192CPM 4192SDTM V-Plex Passive Infrared 998MX 4275EX-SN 4278EX-SN V-Plex (addressable) Contacts 4939SN-WH 4944SN-WH 4959SN V-Plex Glassbreak : 9500SN VISTA interactive phone module 4286 Voice Optional 24V Power Supply PS24 24V power supply 3.4A Long Range Radio: Long Range Radio 7720ULF-XX, 7835C, 7835CF, 7845C Upgraded software Upgraded Compass Downloader Windows compatible Wireless Devices 5804BDV Bi-directional with voice 5804BD Bi-directional Key 5804Watch Wireless Key & sports watch combined 5816 Door/Window 5804 Wireless key 5827BD Bi-directional Keypad 5890 PIR 5849 Glassbreak Detector 5819 Shock Sensor Commercial Wireless Devices Wireless Detector 5809 Wireless Heat Detector 5817CB Wireless Commercial 5869 Hold-Up ENHC Commercial Fire/Burg Receiver VistaKey V-Plex (addressable) VistaKey-SK Starter Kit VistaKey-EX Kit VGM Vista Gateway to PassPoint (Northern Computers) VistaView-100 Switcher or Internet Access Graphical user interface with internet capability Internet Remote Control- Networking Internet Alarm Communicator (7845i) Paging VA8201 AlphaNumeric Pager ORDERING VISTA-128FBP 12V Model V128FBP-24 24V Model Honeywell Security & Custom Electronics 165 Eileen Way, Syosset, NY 11791 www.honeywell.com/security Copyright 2003 Honeywell International Inc. L/V128FBP/D 8/04