User s Instruction Manual Vertex GelMelt 8 Instructions for use

Similar documents
User s Instruction Manual. NextDent LC-3DPrint Box Instructions for use

LC-3DPRINT BOX. Instruction For Use. LC-3DPrint Box

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

Infrared Thermometer

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Spice / Coffee Grinder Instruction Manual

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Dry Bath Heating Systems

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38

Ceramic soleplate steam iron. Help line: Model: SI30110BLKN v1.0

Toaster. Model: ST17020/ST17010 (all colours) v1.0. Helpline:

Safety and Instruction Manual

62 MAX/62 MAX + Infrared Thermometer

KFP-CF Series Operation Manual

ZP2 Series Operation Manual

Operation Manual (Version 1.4.4)

Vacuum Pack Machine Instruction Manual Model GF439-A

USER-MANUAL Tamson Cool Cube Immersion Cooler

Retro Teasmade. Model: STM202N v1.3. For service call

Owner & Operator s Manual. Table of Contents

MT4 MAX/MT4 MAX + Infrared Thermometer

Health & Safety and Installation guide

Kettle v1.2. Models: SK (all models) Helpline:

HOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.

Infrared Thermometer. Getting Started

Operation Manual. WiseClave WAC Steam Sterilizers Digital Fuzzy-controlled Autoclaves. (Version 2.1.1) written for WAC-47/-60/-80/-100 models

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Operator's Manual. LIGHTNING 2 Laser Detector

3 Litre Fryer v2.0. Model: SD6040N. Helpline. SD6040N_IM.indd 1 28/10/ :44

ALMDT-2000 INFRARED MOTION SENSOR

IMPORTANT SAFETY INSTRUCTIONS

Declaration of Conformity no. 56/2012

DynamoCordless POWERFUL 2-IN-1 CORDLESS VACUUM WITH HANDHELD LET S GET STARTED. H85-D-B14 H85-D-B18

ST 53.1 User s manual

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

3 in 1 Can opener with bottle opener & knife sharpener Model: SP20110N

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Corning LSE 6L Digital Water Bath

UNI 321. User s Guide

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

Little Anne. Important Product Information

Get Cleaning... What s your Vax s model number? User Guide. Steam Cleaner. Vax Careline: AU: NZ: VSTHM1600

Safety and Instruction Manual

StableTemp Hotplates, Stirrers and Stirring Hotplates

BEFORE USING THE APPLIANCE

REFRIGERAT A OR USE DF1-15 F ridge

Approvals, Safety Instructions, and Statutory Information

Operating Instructions

USER MANUAL AND TECHNICAL MANUAL

Vintage Desk Fan. Model: SF1010 (all colours) Helpline. v1.1

WELCOME IMPORTANT SAFEGUARDS

Installation guide 864 MTT Multi Thermo sensor Thermometer

User Manual Washing Machine L FL

Corning LSE Benchtop Shaking Incubator

CVC 370 WV 370 WVT 370 WV 380 WV 470. Owner Instructions. Original Instructions Warning! Read instructions before using the machine.

INSTRUCTION MANUAL. LOW SPEED CENTRIFUGE ScanSpeed MiniVac And ScanSpeed MaxiVac. Revision : 01 Date : Cat. No. :

Forced draught gas burner

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Programmable Room Thermostat Installation Instructions

HOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80004

Owner Instructions Original Instructions Warning! Read instructions before using the machine

JVP Owner Instructions. Original Instructions Warning! Read instructions before using the machine.

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Customers must fill in and mail the warranty card in order to activate the warranty.

MiniMax Cooling Counter

CE marking & your legal obligations

64 Max IR Thermometer

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY INFRARED HEATED SEAT MASSAGER MODEL C90005

Portable Sous Vide Instruction Manual

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

wan Travel Kettle designed for life For model: SK27010N v3.2 SK27010N.indd 1 12/02/ :12

Steam Generator v2.0. Model: SI9021N. Helpline. SI9021N_IM.indd 1 28/10/ :45

S/601 Controller Installation Manual

Analog Melting Point Apparatus

64 Max IR Thermometer

Health & Safety and Installation guide

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Model: GF256-A. Waffle Maker. Instruction manual

Owner Instructions HVR HET Warning! Read instructions before using the machine

GMH 285 / GMH 285-BNC

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

MICROFAN B.V. Industriestraat PH Horst P.O. Box AA Horst Developing, manufacturing and marketing of MICROFAN

EU-Type Examination Certificate

5L Water Urn with Gluvine Function SWU5LS. Help line. v1.0

User manual. Fjordblink Birth Pool and Water Supply Unit.

Safety and Instruction Manual

SAFEGUARDING THE ENVIRONMENT IMPORTANT NOTES BEFORE USING THE OVEN OVEN ACCESSORIES CARE AND MAINTENANCE TROUBLESHOOTING GUIDE AFTER SALES SERVICE

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

Owner Instructions Original Instructions Warning! Read instructions before using the machine

ALSET-2000 WIRELESS SECURITY SYSTEM

Evap WTW INSTALLATION INSTRUCTIONS D

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

NoZone Ozone Scrubber

Refrigerated Circulators F12-MP / F25-MP / F26-MP

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

Transcription:

1 Vertex GelMelt 8 Instructions for use

2 1.0. General Cautions - Read this manual carefully before operation. - This machine should be operated by trained user. - The built-in safety mechanisms should not be removed or modified. - Do not allow unauthorized persons to repair the machine. 1.1. Safety Warning Label Information - Do not touch electric parts when connected to power source. - Turn off power source and disconnect input power before installing or servicing the equipment. - Turn off the equipment when it s not in use. - Do not use worn and damaged cables. - Use only well maintained equipment. - Do not handle power code with a wet hand. - Keep children away. - Do not open the cover during operation. - Don t put a hand in a working machine. - Do not close the cover with a hand on the chamber area. - Do not operate the machine when a hand is put into the chamber. - Do not heat up the machine without any Castagel in the chamber. - Do not put a big piece of material into the chamber, cut the gel into small pieces. - Do not touch the cover during heating process (95 C). 2.0 Check the package contents: - Gelmelt 8 - Instructions for use manual - Electric diagram - Declaration of conformity - Warranty conditions The following additional accessories can be ordered separately: - Gelknife - Flask table - Gel Cutter for Melting Chamber - Castaflask - Castagel - Thermometer 2.1 Prepare the place where the Gelmelt 8 will stand: - The place should be flat and dust free. - Make sure there is enough space from the back side and the left side.

3 3.0 Description front panel 3Temperature setting& melting process start/stop button 1 FND Display 4 Delay time setting & increasing button 2Main operation button 5Delay time setting& increasing button 6 LED Cycle Display 1) Main operation button to go into pre-mode. 2) Button to go into temperature calibration mode. 1) Temperature Setting Button to go into temperature setting mode for T1, T2. 2) Melting process, start/stop button. 1) Increasing temperature/time button. 2) Delay time Setting button to go into delay time setting mode. 1) Decreasing temperature/time button. 2) Operation for delay time Start & Stop button.

4 4.0. Description of LED Display at the front of the Geltmelt 8 LED1 LED3 (T1) LED5 (T2) LED2 LED4 LED1 This is called IDLE mode and means that the machine is ready to start the heating mode. By switching on or cancelling the cycle, the machine goes into this step. In this step, 1 Display shows the current temperature. LED2 This is called Heating Mode. The machine can go into this mode by pressing 3 Melting process start/stop button. By pressing 3 Melting process start/stop button, the user can cancel this cycle and the machine goes into IDLE mode again. The machine is heating up to T1 and 1 Display shows the current temperature. LED3 This is called Melting temperature mode. It means that the machine is heated up to T1 and ready to cool down to T2. In this mode, the user can confirm the current temperature. LED4 This is called Cooling Mode. In this mode, the machine is cooling down to T2. LED5 This is called Working mode and the machine is already cooled down to T2 and is keeping the temperature at T2. 1. Do not put anything in the chamber during operation. Don t put a hand in a working machine. 2. Do not close the cover with a hand on the chamber area. 3. Do not use a sharp instrument made of metal. It can cause damage to chamber coating.

5 5.0 Description of the right side of the Gelmelt 8 Identification label 6.0 Description of the back side of the Gelmelt 8 6.1 6.3 6.2 6.1 Adjustable Grip for pouring the remaining gel out of the chamber bottom. Use Adjustable Grip for pouring the remaining gel out of the chamber bottom only for pouring the melted material. When empty, place the machine back in its original position. 6.2 AC power code 6.3 Fuse box

6 7.0. How to Operate 7.1 Switch on - Press Power switch - green colour button located on the left side. - Press Main operation button. 7.2 T1 Melting temperature setting - Check the label of the gel for detailed temperature settings. - Press Temperature setting & melting process, start/stop button for over 2 seconds. - Set Melting temperature by pressing decreasing button or increasing button. - Press Temperature setting& melting process start/stop button to save data. 7.3 T2 Working temperature setting - Check the label of the gel for detailed temperature settings. - Press Temperature setting & melting process, start/stop button again. - Set Melting temperature by pressing decreasing button or increasing button. - Press Temperature setting & melting process start/stop button to save data. 7.4 Checking the temperature T1, T2 - The user can check the temperature T1 by pressing and T2 by pressing then for three seconds, the temperature will be displayed. 7.5 Delay time setting for automatic operation start for next melting process - Press Delay time setting & increasing button for over 2 seconds. - Set Delay time by pressing decreasing button or increasing button from 1 hour to 99 hours. - Press Temperature setting & melting process start/stop button to save data.

7 7.6 To start the melting process with the delay time - Start by pressing Delay time start &stop& decreasing button for over 2 seconds. Then LED1 will be light on and P-r message will be displayed on FND display for 3 seconds. - Stop this process by pressing Delay time start &stop& decreasing button for over 2 seconds. Then P-S Message will be displayed on FND display for 3 seconds. 7.7 Temperature calibration - The temperature of the gel must be checked on a regular basis. - Check the temperature of the gel with a thermometer and compare it to the temperature on the FND display. - Press Main operation button for over 2 seconds. - Control temperature difference by pressing decreasing button or increasing button. - Press Temperature Setting & melting process start/stop button to save data. 7.8 Operation - Press Main operation button. The machine will test itself by self-testing function. - Press Melting process, start/stop button after closing the cover. - When the cover is opened, the machine stops the operation and opn message will be displayed on FND display. - After the machine heats up to T1, the cooling fan will start. - After the machine cools down to T2, an alarm will sound. - By pressing again, the user can stop the operation. 8.0 Error Message 1. Error message Er1 : The temperature probe on the bottom of chamber is the cause of this error, please contact your local vertex maintenance department. 2. Error message Er3 : The motor is the cause of this error, please contact your local vertex maintenance department.

8 3. Error message Er4 : The PC board for heater is the cause of this error, please contact your local vertex maintenance department. 4. Error message Er5 : The temperature sensor for chamber heating element is the cause of this error, please contact your local vertex maintenance department. 5. Error message Er6 : The temperature sensor inside PC board is the cause of this error, please contact your local vertex maintenance department. 6. Error message Err7 : The gel parts are too big, cut the gel into smaller pieces and retry the process. 9.0 Specification 1. Related Voltage: 230V,50Hz,53A 2. Power Consumption: 630W(Max 690W) 3. Fuse: AC 5A,250V 4. Dimension: w: 300mm d: 300mm h: 500mm 5. Chamber Capacity: ± 8 kg 6. Weight: 17.7 kg 10.0 Distributor Information Vertex-Dental B.V. Johan van Oldenbarneveltlaan 62 3705 HJ Zeist The Netherlands. T: +31 (030) 697 67 49 F: +31 (030) 695 51 88 E: info@vertex-dental.com W: www.vertex-dental.com Please note that electrical/electronical units must be disposed of separately. Do not dispose with household waste. The black bar on the garbage bin symbol indicates that the unit was put into circulation after August 13, 2005. Please note that the unit is subjected to regulation 2002/96/EC (WEEE) and applicable national laws and must be disposed accordingly. Please contact your dealer if the unit needs to be disposed of. These instructions for use can contain printing or setting mistakes!

9 11.0 Wiring Diagram

10 Declaration of Conformity The EU Directive covered by this Declaration: 89/336/EEC Electromagnetic Compatibility Directive, Amended by 92/31/EEC & 93/68/EEC. and 2004/108/EC 73/23/EEC Low Voltage Equipment Directive, Amended by 93/68/EEC The Product Covered by this Declaration: Product name : Agar Gel Melting Unit Model name : Gel Melt 8 Serial No. : S/N 0905-230-001 till S/N 0905-230-055 Manufactured at: JM tech 131-3, Sangma-Ri, Daegot-Myun, Kimpo-City, Kyunggi-Do, Korea Authorized Representative: Vertex-Dental B.V. Johan Van Oldenbarneveltlaan 62, 3705 HJ Zeist P.O. Box 10,3700 AA Zeist The Netherlands. The Basic on which Conformity is being Declared. The product identified above complies with the requirement of the LVD & EMC Directive on the basic of the EMC Test Report No: F690501/RF-EMY004657 (Issued Date : Jun18,2009) with EMC Certificate No.: F690501/SP-EMY000214 (Issued Date: June 18, 2009) and LVD Test report No. F690501/RF-SAF002994 (Issued Date: June 19,2009) with LVD certificate No.: F690501/SP- SAF000751 (Issued Date: June 19,2009) by SGS Testing Korea -18-34, Sanbon-dong, Gunpo-si, Gyeonggi-do, Korea 435-041) The product identified above complies with the requirement of the EMC & LVD Directive by meeting the following standards: EN 61010-1: 2001 EN 61326-1: 2006, EN61000-3-2: 2006, EN 61000-3-3: 1995/A1:2001/A2:2006 The products described above comply with the essential requirement of the Directive specified. Signed by Representative: Vertex-Dental B.V. Date of Issue H.G. Jacobs / Director Marketing & Sales June 29, 2009 Signed by Manufacturer/ JM tech A. S Kim / President