CWL Data sheet. Comfort home ventilation system

Similar documents
Operating instructions Oil condensing boiler

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

Overview and Specifications

Ventilation for New Low-Rise Residential Buildings July 20, 2015

BEST PRACTICE RECOMMENDATIONS

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

gaps between walls or ceilings and cornices fixed air conditioners and heaters construction joints between wall materials

Building Regulations Approved Document F1 Means of Ventilation April 2006

Zehnder inside: A perfect indoor climate for all requirements

R A Y H U D S O N MAYFAIR W1K. 21 st March 2011

Indoor Environmental Quality

Technical documentation Comfort domestic ventilation system

The Art of Building Science

VENTILATION DESIGNED FOR CARE HOMES

Building Science Basics

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Larch house and Lime house review of systems design and implementation

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

MECHANICAL VENTILATION

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

SAFETY AND INSTALLATION MANUAL MODEL 8100

Practical Guide for Comfort Ventilation

Zehnder ComfoAir 550. Ventilation unit

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Ventilation in traditional houses

Your comprehensive guide to: Condensation & Mould Growth

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

The Heating System and Ventilation and Combustion Air

Installation of a Brunner fireplace. General Indications

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

J. A. McClelland & Sons

29 BLAKEYS CROSSING, HOWDEN, EAST YORKSHIRE, DN14 7GE

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

GreenMaster HP Exhaust air heat pump for residential properties

SUNDRY ASPECTS OF HEAT RECOVERY VENTILATION. In my earlier articles I have described the basics of a Heat Recovery Ventilation system:

PDH & Professional Training

Ventilation Unit Zehnder ComfoAir 350

USER MANUAL. Cooker Hood ZHG51250GA

The Locomotive. Deepdale Potton, Sandy Bedfordshire SG19 2NH

Installation and maintenance manual

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

8 Paterson Drive Blairgowrie

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

RENTED DWELLING REGULATIONS

Mechanical ventilation with heat recovery

Breathe Fresh Air at Home

Clough Road, Shaw, Oldham, OL2 8QD

TECHNICAL SPECIFICATION

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Technical Bulletin 005(B) Developed with Building Standards Scotland

Whole Home Heat Recovery Ventilation

Uniform Dwelling Code 2017 Updates SPS 323

2015 MECHANICAL CODE REQUIREMENTS

Building and Remodeling to Save Energy 1

Heat Exchanger Earny Type

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Lower Luton Road, Wheathampstead, AL4 8HW 850,000

Healthy, comfortable and energy-efficient ventilation

HeATING. VENTILATION. COOLING. in ONE SYSTEM.

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

60 Woodleigh Gardens, Whitchurch, Bristol, BS14 9JQ

CI/SfB (57.5) November 2008

Home Performance Science

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

10 Bridge Gardens Barnsley 85,000

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

Operating and installation instructions for Fire Lotus H586

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

,4X IMPORTANT SAFETY INSTRUCTIONS

Installation and Maintenance

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. What is condensation?

2006 Upgrade Kit FPX Wood Fireplaces

HOTLINE:

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Exhaust Duct Design Page 1 of (C)

Condensation on Your Windows?

Home Set-up and Maintenance. Maintenance

CHAPTER 8 CHIMNEYS AND VENTS

Treetops, Golf Course Road, Grantown On Spey, PH26 3HY POA

Instructions Manual CTB CTB 9407

8 Randle Bennett Close, Elworth 129,950

Smoke Alarm User s Manual

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Healthy indoor climate. KÖMMERLING ventilation systems

Commissioning of Heat Producing Appliances Burning Solid Fuel

WHHR Midi & Midi Lite

HRU ECO 4 User manual

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

Installation and Maintenance

Transcription:

CWL Data sheet Comfort home ventilation system Wolf GmbH Postfach 1380 84048 Mainburg Tel. 08751/74-0 Fax 08751/741600 Internet: www.wolf-heiztechnik.de 3062320_0408 Subject to changes GB

Table of contents Table of contents... Page Basic terms according to E DIN 1946-6:2006-12...3-6 Operation of firing installations and ventilation units / systems...7 Statement by the Federal Association of Chimney Sweeps...8 Overview of filter classes...9 Air supply and extraction valve positioning...10 Air flow setting... 11 Commissioning report...12 2 3062320_0408

Basic terms according to E DIN 1946-6:2006-12 Extract air room The entirety of the rooms from which air is extracted in duct and fan-assisted ventilation: e.g. kitchen, bathroom, WC, shower room, utility room, sauna room and unoccupied cellar rooms Air extraction system Central fan ventilation system or home ventilation unit which extracts air with the assistance of fans; the supply air (untreated outdoor air) replacing it flows into the utilised space through external wall vents and any leaks in the building envelope Occupation zone Zone in rooms that are intended for continual occupation by people which is defined by a height of 0.1 m to 1.8 m above the floor, a distance of 0.5 m from the external and internal walls and a distance of 1.0 m from external windows, doors and radiators Stack ventilation Form of natural ventilation in which the main driving force is thermal buoyancy Balanced ventilation Fan-assisted ventilation where the supply and extracted air volume flows are designed to have the same value Demand-controlled ventilation Fan-assisted ventilation where the air volume flows are adjusted according to the prevailing requirements (e.g. using sensors) Design differential pressure Intended difference in overall pressure between the air inlets and outlets of appliances or across air vents, e.g. external wall vents and air transfer vents (Air) tightness Description of the condition of the envelope construction with respect to its (air) permeability; synonym for the lowest possible permeability; antonym: leakiness (Air) permeability Air volume flow that, for a given differential pressure, flows into or out of a utilised space through air vents as well as though leaks in the building envelope Facility for natural ventilation Openable window, external wall vent, ventilation duct as well as suitably formed (functional) gaps associated with windows and exterior doors Single fan ventilation system Air extraction system with single fans for apartment blocks or single-family houses Exhaust air vent Device in ventilation ducts, main air ducts or branch air ducts from which the air flows outside in a regulated or unregulated fashion Total outdoor air volume flow The overall effective air volume flow resulting from intended natural or fan- 3062320_0408 3

Basic terms according to E DIN 1946-6:2006-12 Equivalent diameter assisted ventilation as well as from unintended infiltration and window ventilation during the period in which the utilised space is in use Diameter of a straight air duct of rectangular cross section which, for the same air volume flow, gives rise to the same pressure drop as a circular air duct Hydraulic diameter Diameter of an air duct of non-circular cross section which, for the same flow velocity, gives rise to the same pressure drop as a circular air duct Basic ventilation Ventilation necessary both to ensure the preservation of the building and to meet the hygiene and health requirements arising during the intended use of the utilised space (in normal operation) Main duct Preferably vertically running section of the air duct network, into which extract air enters directly though multiple extract air vents or via connecting ducts Hygiene The entirety of the measures serving to sustain and promote physiological and physical well-being and preserve the health of people Intensive ventilation Temporarily increased ventilation necessary to deal with load peaks (load operation) Ventilation components Facility for natural ventilation, or component of systems or devices providing fan-assisted ventilation Air heating Fan-assisted delivery of thermal energy into a room by supplying heated air (supply air temperature > room air temperature) Air-handling unit Assembly for conveying air into or out of a utilised space or single room Single room air-handling unit Air-handling unit for a single room Home air-handling unit Air-handling unit for a utilised space / residential unit Ventilation for prevention of dampness User-independent ventilation (minimum operation) which has the aim of preventing mould and damp damage in the building, subject to the degree of thermal insulation of the building under its typical conditions of use (humidity loading, room temperatures) Ventilation short circuit Ventilation duct Direct intake of exhaust air at an exterior (wall) air vent, supply air at an extract air vent or extract air via leaks from other utilised spaces Predominantly installed (provided by the customer), vertically running individual 4 3062320_0408

Basic terms according to E DIN 1946-6:2006-12 air ducts, which, in the case of fan-assisted ventilation, may comprise a main duct together with the connecting auxiliary ducts from each floor (collecting or network duct) Ventilation heat Thermal energy flow for heating or cooling a mass flow of outdoor air from outside air temperature to supply air temperature Air loading Unfavourable change in air condition due to the uptake of heat and water vapour as well as various kinds of impurities by the indoor air Air heater Facility for the transfer of thermal energy from a transmission (heating) medium to a channelled air mass flow Air conduit Intended indoor air flow when providing fan-assisted ventilation Air mass flow Air mass per unit of time Air temperature gradient Vertical air temperature difference per m, measured between the heights of 1.1 m and 0.1 m above the floor Air volume flow Air volume per unit of time Air change Hourly air volume flow, expressed in units of the volume of a utilised space or room Minimum ventilation User-independent degree of ventilation that fulfils the minimum requirements for indoor air quality under typical conditions of use (humidity and pollutant levels) (Residential) utilised space Apartment (APT), single-family house (SFH) or other comparable group of rooms Cross-flow rooms Rooms in the utilised space which are located in the air flow between supply air and extract air rooms (Enclosed) space Section of a utilised space enclosed by an envelope construction Collecting duct Individual fan Collective term for the main duct and collector or network duct (laid out vertically in each case) or horizontally laid out connecting ducting for main ducts Fan located with the utilised space for extracting air from a room 3062320_0408 5

Basic terms according to E DIN 1946-6:2006-12 Central fan Fan located outside the utilised space for extracting air from or supplying air to multiple utilised spaces or rooms within a utilised space Heat provision efficiency Ratio of the enthalpy recovered by the ventilation unit for usage to the enthalpy difference between the two fluid flows of equal mass on entering the appliance, including increases, e.g. through the use of a heat pump, and reductions, e.g. through the use of a frost protection / dew point device Ground-air heat exchanger Facility for the transfer of thermal energy from the ground to a channelled air mass flow (in the case of heating) or vice versa (in the case of cooling) Wind ventilation Form of natural ventilation in which the wind is the main driving force Residential unit Sum of the rooms that make it possible to conduct a household, in the form an apartment, maisonette or single-family house (free-standing, semi-detached house or terraced house), or a housing unit Central fan ventilation system Air extraction system or air supply and extraction system with central fan for apartment blocks or single-family houses (Ventilation) plant Location of the central installation of air extraction fans or air supply and extraction fans, including the components for heat recovery and outdoor air filtering Air supply and extraction system Central fan ventilation system or home ventilation unit where treated supply air and extract air is conveyed with the assistance of fans Supply air rooms The entirety of the rooms into which, in duct ventilation and air extraction systems, thermally untreated outdoor replacement air flows and, for air supply and extraction systems, treated supply air is fed: e.g. lounge, bedrooms, guestroom, study and nursery as well as constantly or intermittently used hobby (attic or cellar) rooms. 6 3062320_0408

Operation of firing installations and ventilation units / systems According to E DIN 1946-6:2006-12 (Chapter 8), ventilation systems are not permitted to interfere with the normal operation of firing installations. The requirements of the state ordinances for combustion equipment apply here with regard to installation and the supply of air for combustion. A fundamental distinction is drawn between room air-dependent and room air-independent firing installations. Room air-independent firing installations Room air-independent firing installations for which the air for combustion is supplied via pipes or ducts from outside and from which no flue gas can escape into the installation area in dangerous amounts are suitable for operation in conjunction with ventilation systems without the need for any further measures. The provision of instructions for use is mandatory, e.g. a general technical approval. Room air-dependent firing installations Safety devices are required when using a ventilation system with a room airdependent firing installation! There are various possibilities open to you when operating the ventilation system in combination with a firing installation, e.g.: Differential pressure box. Installation of a pressure monitoring unit at the air supply fan or in the air supply duct. The power feed to the air extraction fan is connected only when the air supply fan delivers air. Electrical safeguard. The air extraction fan is switched off when the air supply fan is not running. The correct functioning of the safety device is to be verified and documented on commissioning. The provision of instructions for use is also mandatory here, e.g. a general technical approval. Our recommendation In order to avoid disputes at a later time, we recommend that contact with the professional chimney sweeps' representative for your district (BZSFM) should already be established at the planning stage. See also the official statement by the Federal Association of Chimney Sweeps annex: Central air supply and extraction systems with/without heat recovery 3062320_0408 7

Statement by the Federal Association of Chimney Sweeps ASSESSMENT CRITERIA FOR THE COMBINED OPERATION OF FIRING INSTALLATIONS RESIDENTIAL BUILDING VENTILATION EXTRACTOR HOODS Bundesverband des Schornsteinfegerhandwerks - Zentralinnungsverband ( ZIV ) - Westerwaldstraße 6 53757 Sankt Augustin Tel.: (02241) 34070 www.schornsteinfeger.de The following assessment criteria apply up until the release of corresponding regulations System equipment: Firing installation: room air-dependent Residential building ventilation system: central, air supply / extraction, heat recovery Extractor hood Measures required: Room air-dependent firing installation Separate combustion air feed into the combustion chamber. Cross section in accordance with the firing installation manufacturer s instructions. Simply lined chimney or air exhaust chimney. Connecting piece to be made as leak proof as possible. Residential building ventilation system Frost protection by the air-handling unit must not be implemented by switching off the supply air fan, but e.g. by means of: - outdoor air pre-heating, electric or water heating element - a ground heat exchanger - or equivalent technique The air extraction fan must switch itself off automatically if the supply air fan should fail. Outdoor air Supply air Recirculating air Extract air Exhaust air M Extractor hood Is to be operated in recirculating mode. Can also be operated in exhaust air mode if sufficient provision of supply air ensures that a negative pressure of 4 Pa is not exceeded when the extractor hood is operated at its maximum volume flow. This condition is considered met by a window that has been opened by a sufficiently large amount or an appropriately dimensioned air supply facility where, in each case, the extractor hood is activated by a contact switch or a sufficiently dimensioned supply air fan that is electrically coupled to the extractor hood, or else switching off the extractor hood as a result of an external malfunction signal (e.g. given by a negative pressure monitor at the firing installation) An initiative by the Home Ventilation Association in cooperation with the Federal Association of Chimney Sweeps and: Bau und Betrieb Ridlerstraße 65 80339 München Tel.: (089) 51901018 www.tuev-sued.de Industrieverband Haus-, Heizund Küchentechnik e. V. Stresemannallee 19 60596 Frankfurt am Main Tel.: (069) 2562680 www.hki-online.de Bundesverband der Firmen im Gas und Wasserfach e. V. Marienburger Straße 15 50968 Köln Tel.: (0221) 3764830 www.figawa.de Verband für Wohnungslüftung e. V. Wittinger Straße 46 29223 Celle Tel.: (05141) 214511 www.wohnungslueftung-ev.de 8 3062320_0408

Overview of filter classes Particle size Particle examples Filter class Examples of use Coarse dust filter for particles > 10 µm Fine dust filter for particles 1... 10 µm - Insects - Textile fibres and hairs - Sand - Flue ash - Flower dust - Spores, Pollen - Cement dust - Flower dust - Spores, Pollen - Cement dust - Particles that cause marks and dust deposits - Bacteria and germs on host particles G1 G2 G3 G4 - For simple applications (e.g. as insect guard in compact devices) - Prefilters and recirculated air filters for civilian shelters - Extract air from paint spray booths and kitchens, etc. - Protection against contamination for air conditioners and compact devices and compact devices (e.g. window air conditioners, fans) - Prefilter for filter classes F 6 to F 8 F5 - Outdoor air filter for room with undemanding requirements (e.g. workshops, storage rooms, garages) F5 F6 F7 - Prefiltering and recirculated air filtering in ventilation plants - Final filter in an air-conditioning plant for salerooms, department stores, offices and certain production areas - Prefilter for filter classes F 9 to H 11 Size range for fractional filtration efficiencies depending on the filter classes G 1 to F 9 according to DIN EN 779 Filter in clean condition, not dusty Fine dust (PM10) particulates are particles with a diameter of less that 10 µm Filter class Filtration efficiencies in % Particle size (µm) 0.1 0.3 0.5 1 3 5 10 G 1 - - - - 0-5 5-15 40-50 G 2 - - - 0-5 5-15 15-35 50-70 G 3 - - 0-5 5-15 15-35 35-70 70-85 G 4-0 - 5 5-15 15-35 30-55 60-90 85-98 F 5 0-10 5-15 15-30 30-50 70-90 90-99 > 98 F 6 5-15 10-25 20-40 50-65 85-95 95-99 > 99 F 7 25-35 45-60 60-75 85-95 > 98 > 99 > 99 F 8 35-45 65-75 80-90 95-98 > 99 > 99 > 99 F 9 45-60 75-85 90-95 > 98 > 99 > 99 > 99 Note: This table gives guide values for the various filter classes. Specific values for different filter types must be measured while taking into consideration the flow rate of interest. 3062320_0408 9

Air supply and extraction valve positioning It is hygienically sensible to have air flowing from the living rooms and bedrooms to the functional rooms, bathroom, kitchen, WC, with the hallway being used as a cross-flow area (mechanical cross-ventilation). The interior door serves as an air vent (for a door gap of at least 1 cm) to ensure that air flows from the supply air areas to the extract air areas. Air inlet and outlet vents differ in size, form and colour. At this juncture we are concerned with establishing the appropriate elements with regard to noise level, volume flow and flow propagation. The standard size of the Wolf system design is DN 125. When designing the layout, a maximum air velocity of 3 m/s is assumed. Instructions for positioning air supply elements: Air supply elements can be placed in the ceiling, wall and floor. The flow propagation from the air supply elements is of importance here. Air supply valves should be positioned as far away from the through-flow openings (doors) as possible. Good through flow of the room is achieved in this way. Furthermore, care is to be taken that sitting or lying facilities (beds) are free from draughts. A distance of at least 1 m should be maintained. Pay attention that the air supply elements are not covered (e.g. by curtains or cupboards). Care is to be taken that supply valves are sufficiently far away from the corners of the room; this distance should be at least 60 cm. Instructions for positioning air extraction elements: Air extraction elements can be positioned in the wall or, preferably, in the ceiling. When mounting in the wall, the distance to the ceiling should not be more than 20 cm. As a basic principle, these elements should by positioned in the immediate vicinity of sources of smells and humidity, although not directly above showers or baths since this could lead to the occurrence of draughts (source ventilation principle). Also not advisable is positioning directly above any source of heat (radiators). Air extraction elements with filters are to be used for the kitchen area. Warning: do not position directly above the cooker. 10 3062320_0408

Air flow setting CWL - Measurement report (Annex to commissioning) Volume setting according to E DIN 1946-6 Builder Minimum ventilation = Road Basic ventilation = Post code / Location Intensive ventilation = Phone: Fax: stage 1 = stage 2 = stage 3 = Construction project/ Operator m³/h m³/h m³/h 1 Air flow setting 2 Air volumes set at the central unit in accordance with requirements? yes no 3 Valve setting performed in accordance with volume calculations yes no 4 Valve setting performed with measuring instrument yes no Type: Pay attention to calibration! Measured values Supply air rooms Floor Actual in m³/h Nominal in m³/h OK Living set Dining set Child 1 set Child 2 set Bed set Office set Guestroom set Extract air room Floor Actual in m³/h Nominal in m³/h OK Kitchen (with filter) set WC set Bath set Storeroom set Date, Signature of fitter Date, Signature of builder / operator 3062320_0408 11

Commissioning report CWL Commissioning report Manufacturer: Fitter: Construction project / Operator Wolf GmbH Company Builder Industriestraße 1 Road Road 84048 Mainburg Post code / Location Post code / Location Phone: 08751/74-0 Phone: Phone: Fax. 08751/74-1600 Fax. Fax. System structure: CWL 180 Insulated pipe system CWL CWL 300 Flexible hose system CWL CWL 400 Bypass (CWL 300/400) Accompanying documents: Planning documentation Air flow calculation for minimum, basic and intensive ventilation Operating instructions with service notes Measurement report (air flow setting) 1. Visual inspection 1.1 Installation location - frost free cellar ground floor upper floor loft 1.2 Outdoor air via wall roof 1.3 Exhaust air via wall roof 1.4 Fitted silencer outdoor air exhaust air extract air supply air 1.5 Fitted heating elements preheating elem. postheating element 1.6 Condensate connection - frost free - OK yes no 1.7 Ground heat exchanger present yes no Type: 1.8 Operation via 3-position switch with filter display 4-key remote control 1.9 Electrical installation completed yes no 2. Connection inspection 2.1 Piping securely and neatly fitted to the unit? yes no 2.2 Wall hood and/or roof lead through securely and neatly fitted? yes no 2.3 Air-handling unit filter neatly and correctly installed? yes no 2.4 Supply and extracted air distributors securely and neatly fitted? yes no 2.5 CWL hoses securely fitted to the distributor? yes no 2.6 CWL hoses labelled by room? yes no 2.7 Air supply and extraction hoses laid only the inside thermal wrap? yes no 2.8 Air supply and extraction valves fitted in accordance with the air flow calculation? yes no 2.9 Sufficient potential for cross flow between supply and extracted air rooms as well as cross flow regions e.g. via gaps around doors of approx. 1.5 cm yes no 3. Functional testing 3.1 Functional testing of the ventilation system using the control unit yes no 3.2 Functional testing of auxiliary fittings - preheating element yes no - postheating element yes no - switch or remote control allows all settings to be selected yes no 3.3 Valves set and functional testing completed (with measurement report) yes no 4. Instruction 4.1 Functions of the unit explained and, if necessary, demonstrated? yes no 4.2 Control unit explained and demonstrated? yes no 4.3 Filter changing explained and demonstrated? yes no 5. Miscellaneous 5.1 Are the regulations on safeguarding the combustion air supply satisfied? (Required for: e.g. tiled stoves, fireplaces, gas appliances; consultation with the chimney sweeps' district representative may be necessary) yes no Date, Signature of fitter Date, Signature of builder / operator 12 3062320_0408