A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer

Similar documents
Microspectrometers, which read color and the results

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

An FT-NIR Primer. NR800-A-006

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

From THz to X-ray - Inventing the Future. Progress in NIR spectroscopy and its industrial applications

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Gas Temperature Measurements with High Temporal Resolution

Proceedings Enhanced Characteristics of Nondispersive Infrared CO2 Gas Sensor by Deposition of Hydrophobic Thin Film

Chemistry Instrumental Analysis Lecture 14. Chem 4631

A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

SPECTRAL INSTRUMENTATION

Development of the Micro Capillary Pumped Loop for Electronic Cooling

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Compact Raman spectrometer system for low frequency spectroscopy

VTT silicon photonics driving new business growth in Finland

Questionnaire on activities in radiometry and photometry. Reply from: Korea Research Institute of Standards and Science (KRISS)

JJAP PROOFS. 04R07036 Total pages 5. Effects of Membrane Thickness on the Pyroelectric Properties of LiTaO 3 Thin Film IR Detectors

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

Proceedings Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

SiO 2 /SiN Multilayer-Stack Infrared Absorber Integrated on Pb(Zr 0.4,Ti 0.6 )O 3 Film Pyroelectric Sensors on γ-al 2 O 3 /Si Substrate

Broadening IR applications through using spectral filters

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Induction heating with the ring effect for injection molding plates

Temperature dependent Components within the Pyroelectric Detector

Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

Technological advances within the field of micro multisensors: A Nordic perspective

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

ENHANCED VISION - INFRARED 1

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Measurement of Light. Photosensors

High Sensitivity Explosives Detection using Dual-Excitation- Wavelength Resonance-Raman Detector

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

Detection system for optic characteristics of automobile glasses

LAPIS s SOI Sensor Technology

Understanding total measurement uncertainty in power meters and detectors

Technical specifications of FT-IR Spectrometer

TABLE OF CONTENTS LISTING

Research of High Sensitivity Uncooled Infrared Detector Array

Wildland fire phenomenology experiments:

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Construction of An Automatic Power Switch using Infrared Motion Sensor

APPLICATION NOTE. 1. Introduction Application Considerations

Development of Smart Phone Applications Linked with Fire Alarm Control Panel in Automatic Fire Detection System

Sensor Systems. Impact of Projects based on the Austrian EBS priority. Dr. Martin Kraft CTR AG.

Hybrid fibre optic sensor network for real-time high temperature performance monitoring of steel structures

to get there. together. Infrared Sources Swiss made

Research Article Development of the Noncontact Temperature Sensor Using the Infrared Optical Fiber Coated with Antifog Solution

The FEL Facility Optical Diagnostics and FEL Characterization

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Uncooled Infrared Imaging: Higher Performance, Lower Costs

SILICON SENSOR ACTIVITIES AT SINTEF MINALAB. Marco Povoli, Angela Kok, Ozhan Koybasi

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Optical Fiber Sensing Technology: Basics, Classifications and Applications

Design of CO Concentration Detector Based on Infrared Absorption Method

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Publication American Institute of Physics. Reprinted with permission.

To investigate the surface properties for increasing efficiency of solar water heater

Experiment Study in Optical Fiber Temperature Monitoring

Optical MEMS Technologies for Multi-Spectral Infrared Sensors and Imaging Focal Plane Arrays: from VIS to LWIR

On-chip optical detectors in Standard CMOS SOI

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

Laboratory study of the effects of green roof systems on noise reduction at street levels for diffracted sound

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

Mechanism of audible sound generation during flash lamp operation. Tetsuya Kitagawa, Mitsuru Ikeuchi, Yukihiro Morimoto, Fumihiko Oda

MEMS based sensors for indoor environment applications

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

Research Article Analyzing the Heat Transfer Property of Heat Pipe Influenced by Integrated Cooling Apparatus

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Compact Portable QEPAS Multi-gas Sensor

Advanced gas sensing applications above 3 µm enabled by new DFB laser diodes

Process Technologies for High-Resolution Infrared Detectors based on LiTaO 3

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

Pyroelectric detectors based on high-performance PMN-PT single crystals

Semiconductor Radiation Detectors

Flame Simulator User Manual. Publication Rev. A

E11 Tests of trace gas concentration multicomponent. monitoring system

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

Overview of VTT s activities in photonics, semicon, MEMS and printed intelligence

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Texas active target (TexAT) detector part 1: Design and construction progress

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

MULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING

Time Domain THz Spectroscopy and Related Sensing Applications

Transcription:

Journal of Sensor Science and Technology Vol. 21, No. 6 (2012) pp. 402-407 http://dx.doi.org/10.5369/jsst.2012.21.6.402 pissn 1225-5475/eISSN 2093-7563 A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer Ju Chan Choi 1, June Kyoo Lee 1, and Seong Ho Kong 1,2, + Abstract We report a Fabry-Perot interferometer (FPI)-based multi-channel micro-spectrometer used for multi-gas measurement in the spectral range of 3-5 Ïm and its gas sensing performance. The fabricated infrared (IR) spectrometer consists of two parts: an FPI on the top side for selective IR filtering and a V 2 O 5 -based IR detector array on the bottom side for the detection of the filtered IR. Experimental results show that the FPI-based multi-channel gas sensor has reliability and selectivity for simultaneously detecting environmentally harmful gases such as CH 4, CO 2, N 2 O and CO in the spectral range of 3-5 Ïm. The fabricated FPI-based multi-channel gas sensor also demonstrated that a reliable and selective detection of gas concentrations ranging from 0 to 500 ppm is feasible. In addition, the electrical characteristics demonstrate a superior response performance in regards to the selectivity in the multi-target gases. Keywords : Fabry-Perot interferometer, Multi-channel infrared gas sensor, MEMS 1. INTRODUCTION Many researchers have striven to develop long lasting stable low cost infrared (IR) gas detectors for toxic and environmental pollutant detection. IR gas detectors offer significantly useful characteristics compared to other sensors, especially in their selective gas absorption and reliable optical response. However, many gaseous species have their absorption spectra in an identical spectral region, which makes it difficult to distinguish individual gas species when simultaneously detecting various target gases. As a result, a multi-gas measurement system is needed to meet the requirements for high absorption resolution, species selectivity, and band sensitivity from the near-infrared (NIR) to the mid-infrared (MIR) ranges. Consequently, many different types of Fabry-Perot interferometer (FPI)-based gas sensors and sensor systems 1Graduate School of Electrical Engineering and Computer Science, IT3-213A, Kyungpook National University, 1370 Sangyuk-dong, Buk-gu, Daegu 702-701, Korea 2School of Electronics Engineering, College of IT Engineering, IT3-213, Kyungpook National University, 1370 Sangyuk-dong, Buk-gu, Daegu 702-701, Korea + Corresponding author: shkong@knu.ac.kr (Received : Jun. 26, 2012, Revised : Sep. 7, 2012, Accepted : Sep. 12, 2012) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License(http://creativecommons.org/licenses/bync/3.0)which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. have been developed [1-5]. Makoto et al have reported upon an electro-statically driven tunable FP filter with a wide wavelength range for more precise selective gas sensing [4]. Hui, Carlos, and Vargas et al have presented a fiber FP gas system that measures mixed gas species with a high resolution gas filter utilizing a surface micromachining process [5]. In addition, there are other examples regarding the use of FP filter-based gas sensors and systems [6-9]. In this paper, we present a FPI-based multichannel IR micro-spectrometer used for multi-gas measurement and its gas sensing performance. The FP filter is used as a key component in the sensor reported in this paper and greatly simplifies the construction of the gas sensor. As a result, a simple and highly selective gas sensor is realized in this work. 2. DESIGN 2.1 Structure of the proposed gas sensor Fig. 1 presents the structure of the proposed gas sensor. The proposed multi-channel gas sensor functionally consists of a FPI array on top for selective IR filtering and a corresponding V 2 O 5 -based bolometric IR detector array underneath each FPI filter for the sensing of the filtered IR spectrum. Both the FPI and IR detector are prepared on a double-layer membrane (Si 3 N 4 /SiO 2 ) for minimizing both J. Sensor Sci. & Tech. Vol. 21, No. 6, 2012-402-

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer 9 the parasitic thermal loss generated by thermal conduction and the internal stress of the membrane. The proposed FPI consists of two parallel mirrors, upper silver (Ag) and lower aluminum (Al) layers, and an etalon layer of silicon oxide sandwiched in between the two mirrors. A specific resonance wavelength is selected by different FPI etalon thicknesses. with different SiO 2 interlayer thicknesses of 1.17, 1.50, 1.59 and 1.72 Ïm, used to filter the wavelength range for the target gases. In this work, the spectral range of 3 to 5 Ïm wavelength was scanned and measured for the detection of specific target gases, CH 4, CO 2, N 2 O and CO. The simulated FPI result demonstrates good wavelength filtering characteristics as a function of etalon thickness. Fig. 1. Schematic view of the FPI-based IR spectrometer. The bolometric IR detectors are prepared using vanadium oxide, which is one of the uncooled type IR detectors. A bolometer can detect the presence of IR by the increment or decrement in resistance due to the increment of temperature by IR illumination. A fuller description of the operating principles and IR detection mechanism are described in our previously published paper [10]. Fig. 2 shows the schematic view of the multi-channel gas sensor using the FPI-based IR spectrometer. A stacked pair of FPI and IR detectors placed in multi-arrays is a unit component used to detect a single target gas. By preparing the gas sensing unit in the form of an array, it is possible to simultaneously detect the various target gases. Fig. 3. Simulation results of the FP filter as a function of etalon thickness. Fig. 4 shows the fabricated FP filter characteristics as a function of the etalon thickness measured in order to verify the simulated results. Each FP filter is made on a bare glass substrate for the optical measurement of the FPI-based filter. The results of the fabricated FPI filter were quite consistent with the simulation results, as can be seen in Fig. 4 The discrepancy between the simulated and measured characteristics of the FP filter is mainly due to the nonuniformity in the IR incident angle and variation in the thickness of the thin film. Fig. 2. Schematic view of the multi-channel gas sensor using the FPI-based IR spectrometer. 2.2 Multi-channel FPI Fig.3 illustrates the simulated FP filtering characteristics as a function of the etalon thickness. In the simulation, 30 nm-thick Ag and Al are used as the top and bottom mirrors Fig. 4. Measurement results of the FP filter as a function of the SiO 2 etalon thickness. -403- J. Sensor Sci. & Tech. Vol. 21, No. 6, 2012

10 Ju Chan Choi June Kyoo Lee Seong Ho Kong 3. FABRICATION Fig. 5 shows the fabrication sequence of the FPI-based IR spectrometer. The SiO 2 layer was grown by wet oxidation, and the Si 3 N 4 layer was deposited by PECVD. Vanadium oxide is deposited using an RF sputtering system and patterned using a Cr7SK solution. In order to achieve high performance characteristics in an IR detector, it requires a thermo-sensing film with a high TCR value, low resistance, low noise, and a fast response time. We selected the vanadium oxide thin films as the thermal sensing layer in the un-cooled IR detector for their large TCR, superior electrical resistance, and low 1/f noise. In order to reduce the undesirable electrical parameters, an added annealing process was introduced. The measured TCR value of as-deposited vanadium oxide layer without annealing was approximately -0.9 %/K, which is a rather low value. However, a high TCR value about -4 %/K was achieved after performing an annealing process for 2 min at 500 C. The details of the annealing process can be found in our previously published paper [10]. The measurement results show a good TCR value as well as appreciable electrical resistances suitable for IR sensor applications. Fig. 5. Fabrication sequence for the FPI-based IR spectrometer. (TMAH) solutions in order to minimize the heat loss. The fabricated multi-channel gas sensor using the FPI-based IR spectrometer is shown Fig. 6. Fig. 6. Fabricated multi-channel gas sensor using the FPI-based IR spectrometer. 4. MEASUREMENT The spectral response of the fabricated FPI-based IR spectrometer was measured with the equipment set-up shown in Fig. 7. Optical systems often require the use of a chopper to modulate the light beam. A mechanical optical chopper (Model SR540) was used for square-wave modulation of the optical signal intensity. The unit is capable of chopping light sources at rates of 4 Hz to 3.7 khz. The chopper frequency was set to 800 Hz. The output characteristics of the fabricated device were measured using a lock-in amplifier using the supplied chopper frequency and current signal. A commercialized IR lamp (72-0100-08 IR source BHK (MAX-IR)) was used for the IR source part. Finally, the measured radiation wavelength range at the exit slit of the monochrometer is 1 to 6 Ïm with a 54 mw/cm 2 flux density. The FPI filter layers, Ag/SiO 2 /Al, are then deposited on the front side of the composite membrane by e-beam sputtering and patterned by wet etching. A PECVD oxide layer is used as the etalon layer between the two metal mirrors. The thickness of the etalon layer is controlled during the fabrication process. The oxide layer between the FPI and the IR detector is used for thermal isolation between the FPI and IR detector. The top oxide layer on the FPI keeps the Ag layer from oxidation. The bulk silicon on the backside is selectively etched away using 25 wt% tetramethyl ammonium hydroxide Fig. 7. The measurement set-up used to analyze the FPI-based IR spectrometer. J. Sensor Sci. & Tech. Vol. 21, No. 6, 2012-404-

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer 11 Measurement of the proposed multi-channel gas sensor was conducted by a scanning wavelength within 3 to 5 Ïm at a resolution of 20 nm. Fig. 8 presents the measurement results of the output voltage as a function of the SiO 2 etalon thickness on the fabricated FP-based IR spectrometer. The fabricated IR spectrometer shows the proper output voltage at 3.3, 4.32, 4.5 and 4.62 Ïm peaks that correspond to the wavelengths where CH 4, CO 2, N 2 O and CO gases have their maximum absorption, respectively. gases at concentrations ranging from 0 to 500 ppm. The proposed IR spectrometer-based multi-gas sensor is able to selectively detect different gases simultaneously on a single chip. Fig. 10. The resistance changes of the FPI-based IR spectrometer for CH 4, CO 2, N 2 O, and CO gases at 500 and 1000 ppm concentrations. Fig. 8. The output voltage characteristic of the FPI-based IR spectrometer as a function of the SiO 2 etalon thickness. Fig. 9. The gas measurement set-up used to analyze the FPI-based IR spectrometer. Fig. 11. The resistance change of the FPI-based IR spectrometer as a function of multi-gas concentrations. Fig. 9 and 10 show the gas measurement system and resistance changes of the fabricated IR spectrometer-based gas sensor for CO, CO 2, N 2 O and CH 4 gases depending on their concentrations. The FPI-based IR filter selects a specific wavelength that corresponds to a single target gas and the filtered wavelength spectrum arrives at the IR detector. The measurement results revealed that the fabricated bolometric IR detector shows a different output resistance depending on the concentration of the gas concentration. Fig. 11 displays the gas absorption characteristics of the fabricated FPI-based multi-gas sensor as a function of the target gas concentrations. The measurement results show superior response characteristics for CH 4, CO 2, N 2 O, CO 5. CONCLUSIONS An FPI-based multi-channel IR gas sensor has been designed and fabricated using micro electro mechanical systems (MEMS) technology and its gas sensing performance with CH 4, CO, N 2 O and CO 2 gases have been characterized. The proposed sensor could simultaneously detect the various target gases, CH 4, CO, N 2 O and CO 2 on a single sensor chip. Furthermore, more kinds of gas detection can be realized by the proposed method as etalon thickness engineering on the proposed multi-channel IR gas sensor could control the filtering performance of the target gases. -405- J. Sensor Sci. & Tech. Vol. 21, No. 6, 2012

12 Ju Chan Choi June Kyoo Lee Seong Ho Kong ACKNOWLEDGEMENTS This research was supported by Kyungpook National University Research Fund, 2012. REFERENCES [1] D. Cristea, M. Kusko, R. Muller, E. Manea, and D. Syvridis, Design and experiments for tunable optical sensor fabrication using (111)-oriented silicon micromachining, Sens. Actuators A, Vol. 113, pp. 312-318, 2004. [2] A. T. T. D. Tran, Y. H. Lo, Z. H. Zhu, D. Haronian, and E. Mozdy, Surface micromachined Fabry-Perot tunable filter, IEEE Photonic Tech Letters, Vol. 8, pp. 393-395, 1996. [3] L. y. Lin, J. L. Shen, M. C. Uw, and A. M. Sergent, Tunable three-dimensional solid Fabry-Perot etalons fabricated by surface-micromachining, IEEE Photonic Tech Letters, Vol. 8, pp. 101-103, 1996. [4] M. Noro, K. Suzuki, N. Kishi, H. Hara, T. Watanabe, and H. Iwaoka, CO 2 /H 2 O gas sensor using a tunable Fabry-Perot filter with wide wavelength range, Proc. of IEEE conf. on Micro Electro Mechanical Systems, pp. 319-322, Kyoto, Japan, 2003. [5] C. Calaza, L. Fonseca, M. Moreno, S. Marco, C. Cane, and I. Gracia, A surface micromachining process for the development of a medium-infrared tunable Fabry- Perot interferometer, Sens. Actuators A, Vol. 113, pp. 39-47, 2004. [6] J. P. Dakin, H. O. Edwards, and B. H. Weigl, Progress with optical gas sensors using correlation spectroscopy, Sens. Actuators B, Vol. 29, pp. 87-93, 1995. [7] M. blomberg, A. Torkkeli, A. Lehto, C. Helenelund, and M. Viitasalo, Electrically tunable micromachined fabry-perot interferometer in gas analysis, Physica Scripta, Vol. 69, pp. 119-121, 1997. [8] E. Vargas and H. N. Rutt, Design of CO, CO 2 and CH 4 gas sensors based on correlation spectroscopy using a Fabry-Perot interferometer, Sens. Actuators B, Vol. 137, pp. 410-419, 2009. [9] H. Ding, j. Liang, J. Cui, and X. Wu, A novel fiber Fabry-Perot filter based mixed-gas sensing system, Sens. Actuators B, Vol. 138, pp. 154-159, 2009. [10] J. C. Yang, H. Jung, G. J. Lee, J. Y. Kang, J. G. Koo, J. M. Park, K. S. Park, and S. H. Kong, Microelectro-mechanical-systems-based infrared spectrometer composed of multi-slit grating and bolometer array, Jpn. J. Appl. Phys., Vol. 47, pp. 6943-6948, 2008. Ju Chan Choi received his B.S. and M. Sc. degrees in electrical engineering and computer science from Kyungpook National University, Korea, in 2007 and 2009, respectively. In 2009, he joined the Micro/Nano System Technology Laboratory in the School of Electrical Engineering and Computer Science, Kyungpook National University, where he is currently working as a Ph. D candidate. His research interests include MEMS-based sensors and power MEMS fields. June Kyoo Lee received the B.S. and M.S. degrees in Metallurgical Engineering and Sensor Engineering from Kyungpook National University, Korea, in 2001 and 2003, respectively. In 2008, he joined the Micro/Nano System Technology Laboratory in the School of Electrical Engineering and Computer Science, Kyungpook National University, where he is currently working as a Ph. D candidate. His research interests include electrowetting physics, MEMS-based sensors and actuators, and MEMS-based energy harvesting devices. J. Sensor Sci. & Tech. Vol. 21, No. 6, 2012-406-

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer 13 Seong Ho Kong received his B.S. degree in electronic engineering from Kyungpook National University, Korea, in 1993 and his M.Sc. degree in mechatronics and precision engineering from Tohoku University, Japan, in 1996. In 2002, he received his Ph.D. degree in electrical engineering from Delft University of Technology, the Netherlands, with his thesis work concerning infrared micro-spectrometers, and joined ASM Europe as a senior process engineer. In 2004, he joined the School of Electronics Engineering, Kyungpook National University, Korea. His main research activities currently involve the design and fabrication of sensors/actuators-based on MEMS technology. -407- J. Sensor Sci. & Tech. Vol. 21, No. 6, 2012