Analysis of ventilation system for a microwave assisted drying unit

Similar documents
Fuzzy Controller for Adjust the Indoor Temperature and Preservation the Buildings

Indoor thermal comfort by controlling heat transfer through building envelope

AIR FLOW CHARACTERISTICS IN AN INDUSTRIAL WOOD PALLET DRYING KILN

Study of air circulation inside the oven by computational fluid dynamics.

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

A Study of Drying Uniformity in a New Design of Tray Dryer

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Heat transfer and heating rate of food stuffs in commercial shop ovens

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Numerical study of heat pipe application in heat recovery systems

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

Design And Analysis Of Centrifugal Pump

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Agitation and Mixing

14 Drying. I Basic relations and definitions. Oldřich Holeček, Martin Kohout

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

Refining and Petrochemical Heater trouble shooting

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION

Stock Vessels for Improved Quality and Energy Savings

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

CHAPTER 2 LITERATURE REVIEW

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

ENSC 388: Engineering Thermodynamics and Heat Transfer

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

CFD Model of a Specific Fire Scenario

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Passive Indirect Evaporative Cooler

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Computational simulation of road tunnel fire protection by sprinklers

Heat Transfer in Evacuated Tubular Solar Collectors

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

CFD Analysis of Co-current Spray Dryer with Swirler at Air Inlet

A Novel Approach for the Thermal Management. of PC Power Supply

Numerical Analysis of Water Temperature Distribution in the Tank of. ASHPWH with a Cylindrical Condenser

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Effect of the Use Pattern on Performance of Heat Pump Water Heater

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Air Flow Study inside the Supermarket Refrigeration System

AIRFLOW STUDY OF A SPILT-TYPE OUTDOOR UNIT SUBJECTED TO NEAR WALL EFFECT USING COMPUTATIONAL FLUID DYNAMIC (CFD) SIMULATION

Experimental Investigation of Tube Configuration for a Surface Condenser

American Society of Heating, Refrigerating and Air-Conditioning Engineers

Compression of Fins pipe and simple Heat pipe Using CFD

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

TIL Suite simulates Thermal Systems. Software containing models for thermophysical properties, thermal components and systems

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

DESIGN AND MANUFACTURING OF CHEMICAL AGITATOR

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Performance of an Improved Household Refrigerator/Freezer

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

Development of a Slope Stability Program for Transmission Towers

Computer Models For Fire and Smoke

2. HEAT EXCHANGERS MESA

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Transcription:

Analysis of ventilation system for a microwave assisted drying unit ADRIAN-GABRIEL GHIAUS 1, DANIEL POPESCU 2 and CALIN CIUFUDEAN 3 1 Thermal Engineering Department Technical University of Civil Engineering Bucharest Bd. Pache Protopopescu nr.66, 021414 Bucuresti Sector 2 ROMANIA ghiaus@instal.utcb.ro http://www.mech.upatras.gr/~ghiaus 2 Electrical Department Technical University of Civil Engineering Bucharest Bd. Pache Protopopescu nr.66, 021414 Bucuresti Sector 2 ROMANIA dpopescu@instal.utcb.ro 3 Computers and Control Systems Department Stefan cel Mare University of Suceava Str. Universitatii nr.9, 720225 Suceava ROMANIA calin@eed.usv.ro Abstract: The present study reports on the analysis and optimization of ventilation system inside drying kiln unit. Three-dimensional numerical solution of air flow within the drying kiln enclosure contributes to the improvement of the final product quality. The air flow field is examined in different configurations and operation conditions. Depending on the off/on switched fans, we obtain various air flow distributions. The simulation was performed using the Comsol Multiphysics program using the k-ε turbulent mode in steady-state regime. The results highlight the position of the recirculation regions and the distribution of the air flow inside the drying chamber. Keywords: CFD, air flow, simulation, microwave drying, automatic control. 1 Automatic dryer prototype 1.1 General Specifications Automatic drying system for building materials using microwaves may be used for the following materials: wood, bricks, ceramic materials, shuttering for concrete, etc., and it has been tested for drying of several shaped timber wood species. The main purpose o drying is to remove the excess water from the material structure and to preserve their properties after drying. The prototype of the automatic drying system (Fig.1 a, b and c) is made under a compact rectangular form, containing the drying chamber and the control room with total dimensions of 3,2m x 2,2m x 2,2m. The dimensions of drying chamber are 2m x 2m x 2m, and for the control room 2m x 1m x 2m. The maximum volume of the drying material stack is of 3,2m 3. Fig.1a: Overview of the drying system ISBN: 978-1-61804-027-5 138

programming when putting into operation, for saving the data and for performing mathematical processing in order to issue reports on how the drying took place. Conservation of the building materials properties is ensured by using appropriate drying programs chosen from the automation system library. Safety operation of the drying system is ensured by the existence of protection and signaling elements required for all situations that arise in normal or abnormal operation regimes of the dryer. Fig. 1b: Drying room Fig. 1c: Control room The materials used to make the drying chamber have to provide the following two requirements: - thermal insulation from the external environment; - electrical shielding of drying chamber, so as the microwaves do not affect the health of personnel operating the automatic dryer. The dryer can be easily transported and positioned by the user in the place where the drying should be done, because it requires only connection to the low power supply voltage. The maximum power absorbed from the electrical network is 25 kw. The drying system is composed of the following main parts: - drying chamber, containing microwave generators, ventilators and inlet and outlet holes for the drying air; - automatic driving equipment (PLC with extension modules, sensors for temperature, humidity and weight, protection and warning sensors); - specific software for the application (programs installed on the PC and PLC). Microwave generators are identical and each one has the useful power between 900W and 1000W. The number of generators that will operate and their operation times for drying different building materials are determined by automatic drying programs belonging to automated library management system of the dryer. Since the automatic driving system of the dryer is programmed logic implemented, this permits a good flexibility for choosing the drying regimes for different types of building materials or for the same type of material. Graphical man-machine interface displays in real time the parameters of drying process and the current faze in which the process exists, permits inputs of reference values for specific drying parameters and the selection of wanted drying program. The interface between PLC and PC located on the superior level, is useful for PLC 1.2 Transducers for measurement of process parameters Automatic management system of the drying process continuously receives information concerning the drying degree of the material and stops the process when the drying degree imposed for that material is reached. Material (wood) temperature from the stack is measured by distance method, using an infrared radiation pyrometer. The air temperature and humidity inside the drying room is measured using specialized transducers, each pair being placed in three different zoned of the drying room (Fig. 2). Humidity transducer Temperature transducer Wire mesh Fig. 2: Detail of drying room Ventilator Transducer protection against harmful electrical signals that would overlap the useful signals which represents the measured values, is ensured by using a metal mesh shielding against microwaves action. The mesh has hole dimensions smaller than the microwave wave length. At the end of the drying process it occurs a slow thermal stabilization of the material by bringing its temperature at the normal value. This ensure a ISBN: 978-1-61804-027-5 139

structural and dimensional stability of the material and reduces the possibility of defects occurrence in material. 2 Air flow inside drying room The way in which the air flows inside drying room favors the drying process of building materials by removing water molecules from the drying material surface that have received the requested energy in order to transform in vapor from microwave units. The air movement is ensured both at the external surface of the building material stack and through the spaces between the stack layers, especially created for this reason. The air currents takes the humidity resulting from the drying process. 2.1 Solutions and optimization of air movement Analysis and optimization of air flow distribution inside drying kiln systems contribute to the improvement of the final product quality. The air flow field is examined in three-dimensional different configurations and operation conditions. Depending on the off/on switched fans, we obtain various air flow distributions. The simulation was performed using the Comsol Multiphysics program using the k-ε turbulent mode in steady-state regime. The effect of the turbulence modeling is distinguished through a direct comparison between the results. The results highlight the position of the recirculation regions and the distribution of the air flow. Four different operation solutions were analyzed: - a) two recirculation fans situated on opposite sides and at different heights are running; - b) four recirculation fans situated in pairs of two on opposite sides are running; - c) four recirculation fans and one exhaust fan are running and there is an open air slit; - d) one exhaust fan is running and there is an open air slit. The simulation results are presented as 3D velocity distribution diagrams corresponding to certain zones inside the kiln. The analysis of the results leads to the adjustment of the operation parameters and to the space optimization of the fan arrangement, in order to obtain the maximum efficiency. There were analyzed different constructive solutions and different operation regimes for the air movement system inside the drying room by numerical simulation using COMSOL software. 2.2 Geometry of the drying kiln The 3D view of the considered industrial type of wood drying kiln is shown in Figure 3. The drying unit system consists of a kiln chamber inside which there are four recirculation fans and on this chamber there is an exhaust fan. Fig. 3: The 3D view of the wood drying kiln Because the exhaust fan doesn t work correctly without fresh air, it is necessary to mount a fresh air slit on the vertical front side. The kiln chamber is considered a cube with a two-meter long edge. The diameter of the recirculation fans is 250mm and of the exhaust fan is 200mm. The fresh air slit has a height of 2000mm and a width of 40mm. These fans are situated at different heights and on opposite sides. 2.3 Boundary conditions and mesh cells The grids for the drying kiln consist of 150.000 elements and the result of this can be seen in Fig, 4. Fig. 4: The 3D view of the meshed wood drying kiln ISBN: 978-1-61804-027-5 140

The boundary conditions for the air flow are determined by the performance of the axial flow fan. The total air volume flow rate through the kiln chamber is given by the pressure jump across the axial fan and its value results from the performance curves of the fan. At the inlet, uniform velocity distribution is assumed (v o =0.7m/s) and this corresponds to Q o =123.7m³/h. The turbulence models are valid only in fully turbulent regions. Close to the wall, where viscous effects become dominant, the models are used in conjunction with the wall functions. For this study, the convectional equilibrium logarithmic law governing the wall is used. The computational domain is meshed and fine grid spacing close to all the walls has been applied, in order to resolve steep gradients. 2.4 Numerical simulation of the inside fans In order to accurately model the inside fans without having to model the geometry of the blades and rotate them throughout the simulation a hybrid approach was used, i.e. the action of the blades on the air was introduced as volume forces in the Navier-Stokes equations for the sub-domains representing the fans. First, the fans were modeled as different cylindrical sub-domains in the kiln. Fluid characteristics of the sub-domains (temperature, density and viscosity) were considered the same as the ones in the kiln i.e. t = 20 C, ρ = 1.21 kg/m³ and η = 1.98 10-5 Pa s. Only the volume forces terms on the three axes were different. Second, the pressure drop vs. flow rate curve of the fans was approximated by a 3 rd order polynomial to yield a function. Third, an integration coupling variable was set on the boundary representing the inlet cross-section of each interior fan. In this variable the program integrates the velocity component normal to the inlet cross-section (i.e. axial inlet velocity in the fan) which gives the flowrate trough the fan at each iteration Q. Finally, we introduced in each sub-domain, in the volume force corresponding to the axial direction for each inside fan, the formula of the pressure-drop computed with the corresponding variable representing the flowrate, divided by the length of the fan (in order to get, in each cell of the sub-domain a volume force that would yield in the outlet section of the fan the pressure drop corresponding to the flow rate for each iteration). Axial fans also induce a rotational velocity component at the outlet. In order to introduce this component as volume forces in the sub-domains, we have to analyze the velocity triangles for axial hydraulic machineries (Figure 5), where inlet velocities are colored in blue and denoted with subscript 1, while outlet velocities are colored in red and denoted with subscript 2. Fig. 5: Velocity triangles for axial hydraulic machineries As the inlet velocity is considered normal to the fan inlet cross-section, and the flow rate trough the fan is constant this results in an equal meridian velocity at the outlet v m2. On the other hand the transport velocity is known as long as we know the rotating speed of the fan ( n ) and the radius where we perform the computation ( r ): u1 = u2 = 2π n r (1) The fundamental equation for turbo machineries is: 1 HT = ( u2 v2 cosα2 u1 v1 cosα1) (2) g which, for an axial fan with normal inlet velocity ( α 1 = 90 o ), yields: (3) p= ρ u 2 v 2 cosα2 Hence the tangential component of the velocity is: ρ g H p v T 2 cos α2 = = (4) ρηh u2 ρ2π n r This component is only a function of constant rotating speed of the fan, pressure drop and radius with respect to the centre of the fan where calculations are made. It can also be included as volume forces in the sub-domain representing the fans if geometrically decomposed with respect to the two axes that are normal to the axis of the fan. This is a simple geometrical transformation as long as we know the coordinates of the cell in which the term is added. A problem is still the presence of the radius in the denominator of the equation. This means that cells situated near the axis of the fan r 0 will yield infinity when computing the tangential component of the velocity. The model of the fan can not be a simple cylinder but rather an annular shape in order to bypass this problem. In fact the annular shape model is closer to an real axial fan than the cylindrical model as any axial fan has a shaft that does not permit air flow trough the exact centre of the fan. Several simulations were performed both with the complete model (i.e. both axial and tangential volume force terms) and with the simplified model ISBN: 978-1-61804-027-5 141

(i.e. only axial volume forces terms).by comparing the results and the corresponding computational times we finally adopted the simplified model for the inside fans of the kiln. The tangential component of the volume forces has shown to be very small with respect to the axial one and disappeared almost instantly after the air left the fan. It also increased the computational time by a factor of 2 with respect to the simplified model. In the sequel this simplified model was used for all simulations. The simulation was performed based on the Navier Stokes equation [6]: V ρ µ 2 (5) where + V V = p+ t V + V V t V + F ρ is the vector tensor form, p is the pressure, µ is the viscosity and F is the specified force. view and top view, respectively. Enclosure dimensions are in meters. Fig.7: Velocity distribution in two vertical sections 2.5 Performances of air circulation system The results of computer simulations, for the chosen solution, are presented below in the form of graphs, which show the distribution of air pressure and velocity inside the drying chamber. Distribution of pressure values (expressed in Pa) in two vertical sections of the drying chamber containing fans, is shown in Figure 6. Enclosure dimensions are in meters. Fig. 8: Distribution of air velocity vectors in the entire drying chamber Fig. 6: Pressure distribution in two vertical sections Distribution of velocity (expressed in m/s) that the air circulates in vertical sections of the enclosure in which fans are located, is shown in Figure 7. Enclosure dimensions are in meters. Distribution of air velocity vectors in the entire volume of drying chamber is shown in Figure 8. The trajectory of a particle moving through air space of the drying chamber under the fans action is shown in Figure 9a and Figure 9b, in perspective Fig. 9a: Particle trajectory - perspective view ISBN: 978-1-61804-027-5 142

- microwave drying method, due to low drying temperature, reduces the amount of volatile organic mixtures transferred from the drying material to the air in the drying chamber, thus reducing environmental pollution. Fig. 9b: Particle trajectory - top view 3 Conclusions After analyzing the results of the performed computer simulations, the following solutions have been chosen for air circulation inside the drying chamber prototype unit: - The fans are mounted on vertical bars that are positioned in two of the four corners of the drying chamber, located on the diagonal; - The fans can be rotated around the axis of the fixation bar for changing their orientation; - Four fans are used in total, two on each vertical bar; - An extraction fan for the discharge of moist air from the drying chamber is necessary. It operates when the air humidity in the chamber exceeds the predetermined value. [7] The main advantages of using microwave assisted dryer for drying building materials are the followings: - microwaves heat directly the water molecules inside the material to be dried; - rapid and uniform heating of the entire volume of material; - heating the material at a lower temperature compared with conventional drying methods; - avoid excessive drying of the material because the proposed dryer has a device that continuously measures the moisture content of building materials subject to drying; - better quality of the dried building material during storage time; - relatively low cost of maintenance of equipment during the operation; References: [1] Z.F. Sun, C.G. Carrington, J.A. Anderson & Q. Sun, Air flow patterns in dehumidifier wood drying kilns, IChemE, Chemical Engineering Research and Design, Volume 82, 2004, pp 1344-1352. [2] D.P. Margaris & A.G. Ghiaus, New Food Engineering Trends, p.p. 45-102, Nova Science Publishers, Inc., New York, 2008. [3] D.P. Margaris & A.G. Ghiaus, Dried products quality improvement by air flow manipulation in tray dryers, Journal of Food Engineering, Volume 75, 2006, pp 542-550. [4] M. Tabsoba, J. Moureh & D. Flick, Airflow patterns in an enclosure loaded with slotted pallets, International Journal of Refrigeration, Volume 29, 2006, pp 899-910 [5] E. Mathioulakis, V. T. Karathanos and V. G. Belessiotis, Simulation of air movement in a dryer by computational fluid dynamics: Application for the drying if fruits, Journal of Food Engineering, Volume 36, 1998, pp 183-200. [6] C. Ciufudean and B.Satco, Performance Evaluation of Discrete Event Systems Involving Henstock-Kurzweil Integral, Journal of Systems Science and Systems Engineering, Volume 18, Number 2, June 2009, pp.134-148. Acknowledgements This work was financed in part by Romanian Ministry of Education and Research in the frame of the Second National Plan for Research, Development and Innovation. ISBN: 978-1-61804-027-5 143