Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems

Similar documents
Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

Waters 2695 Separations Module

Agilent PlateLoc Thermal Microplate Sealer

Waters 2695D Separations Module

Technical Bulletin April Opticom Infrared System. Optical Preemption Detector Identification Guide

Ion PGM Hi Q View Sequencing Kit

Ion OneTouch Template Kit Publication Part Number Revision E Date 31 October 2011

Waters 2795 Separations Module

RNAscope LS 4-plex Fluorescent Assay

MiniAmp Thermal Cycler and MiniAmp Plus Thermal Cycler Installation and Operation

Applied Biosystems 3730/3730xl DNA Analyzer

Environmental Monitoring SmartSlot Card

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

IEC Lighting Contactor Specifications

Environmental Monitoring Card


Advanced Autodesk Authorized Training Courseware (AATC) AutoCAD. Architecture 2009

CONTROL BE MADE CHANGES MAY NOT. Page 1

Instruction Manual CHLORALERT TM Series T17CA4000 Chlorine Gas Leak Detector CAPITAL CONTROLS

Multiscreen Vacuum Manifold User Guide for ZipPlate micro-spe Plate

PolySwitch TS600 Overcurrent Protection Devices

V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS

MicrOTDR. Optical Fault Locator. User Manual

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

Spy Jeepmeter ope rati ng instructions

NoZone Ozone Scrubber

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

SPME-FFA Field Sampler

Keysight 85025/85026 Detector Exchange Program - All Serial Numbers

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Enhancing Cutting Productivity by utilising Pierce Detection capability

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Intrinsically Safe Transmitters, Option Code 2n

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Forked Pyrolytic Platforms

Blue. new. Fisher Scientific! See more Blue in your lab with great savings from

High Output Vacuum/Pressure Pump

Thermometer model 02059

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Installation Instruction Manual ILS-S

RSMSD Technical Guide

Protégé Eclipse LED Keypad User Manual PRT-KLES

Installation Instructions for the

NetworkAIR RM Air Distribution Unit

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

General Animal Injections

AN10943 Decoding DTMF tones using M3 DSP library FFT function

WEB GAUGING AT A GLANCE

HIH-4000 Series Humidity Sensors

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

Dolphin 9900 Mobile Computer

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

SYSTEMS FOR UXO AND LANDMINE DETECTION

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

installation instructions Fan Tray System FTA-3/FTA-6


Vanquish. Split Samplers VH-A10, VF-A10. Operating Manual

START HERE. Set up. Your smart phone Receiver Sensor. Transmitter

Multi-Mode Electrode pro

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

User Manual. Thermo Scientific ALPS30 Manual Heat Sealer

ACQUITY UPLC HT Column Heater Instructions

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Model 5190-F Temperature/Humidity Probe

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

Refrigerated Cooling System

C A Heating Cable Gland Kit

NicheVision Sole Source Justification STRmix Mixture Interpretation Software Justification for Non-Competitive Procurement

Model 5190-E Temperature/Humidity Probe

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

Innovative. Integrated. Simple.

Thermometer with Probe model 00891A

Supervisor Standard Edition

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

Dräger Pac 3500 Single-Gas Detection Device

User Guide Digital Bill Counter AB4000

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Evaluation of Biomek FX SV 96 Method Gripper Moves

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

HOA6480 Series Barcode Sensor Infrared Products

E911 Manual. Empowered by Innovation P/N E911. For additional resources, visit our Technical Support site on the web at

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

ACONT600AF11MA/ACONT602AF22MA Programmable Comfort Control

ABS HOPPER LID SWITCH KIT ASSEMBLY

Thermometer with Wired Sensor

A new wave in automated instrument washing. Introducing the new HYDRIM G4 series

Figure 1 DirectLine DL423 Sensor. Description, continued

User Guide. Portable banknote counter AB300

RES-210 (-211, -220, -221) / RES-420

Spy model 673 wet sponge holiday detector ope rati ng instructions

Transcription:

User Bulletin ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers August 2006 SUBJECT: Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems In This User Bulletin This user bulletin covers: Overview.......................................................... 1 Materials.......................................................... 1 Distinguishing the MicroAmp Fast and MicroAmp 96-Well Reaction Plate...... 4 Assembling the Fast Plate Adapter for the ABI PRISM 310 Genetic Analyzer..... 5 Identifying the 96-Well Plate Adapters for the 3100/3130 Genetic Analyzers..... 6 Identifying the 96-Well Septa Seal Plate Adapters for the 3730/3730xl DNA Analyzers.......................................................... 8 Overview Use of MicroAmp Fast Optical 96-Well Reaction Plate or MicroAmp Fast 96- Well Reaction Plate on an Applied Biosystems capillary electrophoresis (CE) instrument requires the specific Fast plate adapter designed for the particular instrument model. This document describes the part numbers for the adapters used with each instrument model and the key differences between the standard and Fast plate adapters. Except for the 310 Fast plate adapter, which is a single piece, adapters consist of a plate base and a matching plate retainer. IMPORTANT! To avoid damage to the capillary (310) or capillary array (3100/3130/3730), use only Fast plate adapters with Fast 96-well reaction plates and only standard adapters with standard 96-well plates. Materials Materials for the ABI PRISM 310 Genetic Analyzer Item Applied Biosystems Part Number Fast Components Fast Plate Adapter for the ABI PRISM 310 Genetic Analyzer MicroAmp Fast 96-Well Reaction Plate (0.1 ml), 10 plates MicroAmp Fast Optical 96-Well Reaction Plate with Barcode (0.1 ml), 20 plates 4370141 4346907 4346906 96-Well Plate Septa, 20 pack 4315933 December 20, 2006 2:14 pm, PlateAdapter_modified.fm

ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers Materials for the ABI PRISM 3100 and 3100-Avant Genetic Analyzers and Applied Biosystems 3130 and 3130xl Genetic Analyzers Item Applied Biosystems Part Number Standard Components 96-Well Standard Plate Base for 3130 and 3100 Series Genetic Analyzers, 4 pack 96-Well Standard Plate Retainer for 3130 and 3100 Series Genetic Analyzers, 4 pack MicroAmp Optical 96-Well Reaction Plate, 10 plates MicroAmp Optical 96-Well Reaction Plate with Barcode, 20 plates 4317237 4317241 N8010560 4306737 96-Well Plate Septa, 20 pack 4315933 Fast Components 96-Well Fast Plate Base for 3130 and 3100 Series Genetic Analyzers, 4 pack 96-Well Fast Plate Retainer for 3130 and 3100 Series Genetic Analyzers, 4 pack MicroAmp Fast 96-Well Reaction Plate (0.1 ml), 10 plates MicroAmp Fast Optical 96-Well Reaction Plate with Barcode (0.1 ml), 20 plates 4367470 4367471 4346907 4346906 96-Well Plate Septa, 20 pack 4315933 Materials for the Applied Biosystems 3730 and 3730xl DNA Analyzers Item Applied Biosystems Part Number Standard Components 96-Well Plate Base (Septa Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 96-Well Plate Retainer (Septa Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 96-Well Plate Base (Heat Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 96-Well Plate Retainer (Heat Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 4334873 4334869 4334875 4334865 2 User Bulletin

Item MicroAmp Optical 96-Well Reaction Plate, 10 plates MicroAmp Optical 96-Well Reaction Plate with Barcode, 20 plates Applied Biosystems Part Number N8010560 4306737 96-Well Plate Septa, 20 pack 4315933 Fast Components 96-Well Fast Plate Base (Septa Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 96-Well Fast Plate Retainer (Septa Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 96-Well Fast Plate Base (Heat Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack 96-Well Fast Plate Retainer (Heat Seal) for use on Applied Biosystems 3730 and 3730xl DNA Analyzers, 4 pack Heat Seal Film for Sequencing and Fragment Analysis Sample Plates MicroAmp Fast 96-Well Reaction Plate (0.1 ml), 10 plates MicroAmp Fast Optical 96-Well Reaction Plate with Barcode (0.1 ml), 20 plates 4367469 4367472 4367473 4367474 4337570 4346907 4346906 96-Well Plate Septa, 20 pack 4315933 Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems 3

ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers Distinguishing the MicroAmp Fast and MicroAmp 96-Well Reaction Plate The Fast 96-well reaction plates and the standard 96-well reaction plates differ in two ways. The wells of the standard plate have a volume of 0.2 ml; the wells of the Fast plate have a volume of 0.1 ml. The Fast plate also has shallower wells than those of the standard plate (Figure 1). The well-depth differences require that you use the plate adapter designed for the plate type that you use on the Applied Biosystems CE instrument. Otherwise, the capillaries (310) or capillary arrays (3100/3130/3730) are damaged. Standard Plate 0.2-mL well volume Fast Plate 0.1-mL well volume GR2386 7900 HS96 well plate comparison Figure 1 Standard and Fast 96-well reaction plate well volumes and depths The notch on the standard plate is at the A12 corner; the notch on the Fast plate is at the A1 corner of the plate (Figure 2). Notch at topright corner by A12 Standard Plate GR2386 7900 HS96 well plate comparison Fast Plate Notch at topleft corner by A1 Figure 2 Standard and Fast 96-well reaction plate notch locations 4 User Bulletin

Assembling the Fast Plate Adapter for the ABI PRISM 310 Genetic Analyzer The Fast plate adapter for the ABI PRISM 310 Genetic Analyzer is designed to hold only the Fast 96-well plate. Standard 96-well plates cannot be used on the ABI PRISM 310 Genetic Analyzer. Figure 3 The Fast plate adapter 1. Place the Fast plate adapter on the autosampler tray holder. Match the notch on the autosampler tray holder to the rectangular hole in the Fast plate adapter (Figure 4). Press down on all four corners of the adapter to ensure proper seating. Figure 4 The Fast plate adapter and autosampler tray holder assembly Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems 5

ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers 2. Place the Fast plate on the adapter. Match the notch at A1 to the notch of the Fast plate adapter (Figure 5). Press down on all four corners of the adapter to ensure proper seating. Use a 96-well plate septa seal to seal samples before electrophoresis. Figure 5 The Fast plate and Fast plate adapter assembly 6 User Bulletin

Identifying the 96-Well Plate Adapters for the 3100/3130 Genetic Analyzers The Fast plate adapter for the 3100 and 3130 Genetic Analyzers is easily distinguishable from the standard plate adapter (see table below). However, the assembly procedure for the Fast plate adapter is identical to that of the standard plate adapters. Refer to the appropriate instrument user guide for more information about the assembly procedure. 3100/3130 Genetic Analyzers Standard (0.2 ml) Plate Adapters 3100/3130 Genetic Analyzers Fast (0.1 ml) Plate Adapters The standard plate adapter has a white retainer and black base. The Fast plate adapter has a blue retainer and blue base. The standard plate adapter has no labels. The Fast plate adapter has matching Fast labels on the short side of the plate assembly. IMPORTANT! Ensure labels match during assembly to avoid damage to the array. The A12 corner of the base is notched, matching the standard 96-well reaction plate. The A1 corner of the base is notched, matching the Fast 96-well reaction plate. Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems 7

ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers Identifying the 96-Well Septa Seal Plate Adapters for the 3730/3730xl DNA Analyzers IMPORTANT! Verify that your instrument has Data Collection 3.0 or later software versions. Do not use the Fast plates if you have Data Collection software version 1.0 or 2.0. The Fast septa seal plate adapter for the 3730/3730xl DNA Analyzers is easily distinguished from the standard septa seal plate adapter (see table below). However, their assembly procedure is identical to that of the standard adapter plates. Refer to the appropriate instrument user guide for more information about the assembly procedure. 3730/3730xl Standard Plate Adapters 3730/3730xl Fast Plate Adapters Heat seal Plate adapter Septa seal Plate adapter The standard plate adapter for heat film sealed plates has a white retainer and gray base. The standard plate adapter for septa-sealed plates has a white retainer and black base. Heat seal Plate adapter Septa seal Plate adapter The Fast plate adapter for heat film sealed plates has a white retainer and dark blue-green base. The Fast plate adapter for septa-sealed plates has a white retainer and blue base. The standard plate adapters have no labels. The Fast plate adapters have Fast labels on the long side of the plate assembly. IMPORTANT! Ensure labels match during assembly to avoid damage to the array. 8 User Bulletin

3730/3730xl Standard Plate Adapters 3730/3730xl Fast Plate Adapters The A12 corner of the base is notched, matching the standard 96-well reaction plate. The A1 corner of the base is notched, matching the Fast 96-well reaction plate. Note: The Fast plate adapter has two notches on the A1 and A12 corners. The notch at the A12 corner orients the plates correctly in the 3730 stacker. Heat Seal Recommendations Do not use a heat seal film that is thicker than 1 mil after the heat sealing process. Do not use heat seal film containing adhesives or metals. Such materials maydamage the instrument s piercing needles. Note that the MicroAmp Fast Reaction Plate may require a separate heat sealer setting than the standard reaction plate due to dimensional differences. Contact your heat sealer manufacturer if you have questions regarding sealing the MicroAmp Fast or Microamp 96-Well Reaction Plate. Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems 9

ABI PRISM 310, 3100 & 3100-Avant Genetic Analyzers, Applied Biosystems 3130 & 3130xl Genetic Analyzers, and Applied Biosystems 3730 & 3730xl DNA Analyzers This page is intentionally blank. 10 User Bulletin

This page is intentionally blank.

Copyright 2006, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Information in this document is subject to change without notice. Applied Biosystems assumes no responsibility for any errors that may appear in this document. This document is believed to be complete and accurate at the time of publication. In no event shall Applied Biosystems be liable for incidental, special, multiple, or consequential damages in connection with or arising from the use of this document. TRADEMARKS: Applera, Applied Biosystems, AB (Design) and ABI PRISM are registered trademarks and MicroAmp is a trademark of Applera Corporation or its subsidiaries in the US and/or certain other countries. All other trademarks are the sole property of their respective owners. Worldwide Sales and Support Applied Biosystems vast distribution and service network, composed of highly trained support and applications personnel, reaches 150 countries on six continents. For sales office locations and technical support, please call our local office or refer to our Web site at www.appliedbiosystems.com. Applera is committed to providing the world s leading technology and information for life scientists. Applera Corporation consists of the Applied Biosystems and Celera Genomics businesses. Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone: +1 650.638.5800 Toll Free (In North America): +1 800.345.5224 Fax: +1 650.638.5884 www.appliedbiosystems.com Part Number 4370890 Rev. C Stock Number 106UB48-03