Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Similar documents
Heat transfer and heating rate of food stuffs in commercial shop ovens

A study of Transient Performance of A Cascade Heat Pump System

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Global Journal of Engineering Science and Research Management

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Temperature and time impact on food safety in domestic refrigerator

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

Mathematical Simulation of Longan Fruit Drying

Performance Study of Triple Concentric Pipe Heat Exchanger

International Journal of Food and Biosystem Engineering. May 2015 Vol. 1, No. 1. Optimisation of industrial Food Drying Operation. Henry T.

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

2. HEAT EXCHANGERS MESA

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

MODEL AND SIMULATION OF DEEP-BED CLOVE DRYING: EFFECT OF FERMENTED TREATMENT

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Study of air circulation inside the oven by computational fluid dynamics.

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven

Heat Transfer in Evacuated Tubular Solar Collectors

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Compression of Fins pipe and simple Heat pipe Using CFD

THE EFFECTS OF HUMIDITY, COMPRESSOR OPERATION TIME AND AMBIENT TEMPERATURE ON FROST FORMATION IN AN INDUSTRIAL FRIDGE *

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

Recent Advances in Energy, Environment and Economic Development

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Estimation of Spray Lubrication and Die Temperature for Die Wear Life Prediction in Hot Forging

for family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

Control Method Of Circulating Refrigerant Amount For Heat Pump System

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

A Monte Carlo Approach for the Design of Thermal Fire Detection System

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

A Study of Drying Uniformity in a New Design of Tray Dryer

PRODUCING COOLING FROM SOLAR ENERGY BY USING ADSORPTION CYCLE WITH ACTIVATED CARBON AND METHANOL PAIR

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Shortcut Model for Predicting Refrigeration Cycle Performance

DOMESTIC DEHUMIDIFIERS IN COOL CONDITIONS: I PERFORMANCE FACTORS

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

EFFECT OF THE PACKING DENSITY ON THE MECHANICAL IMPEDANCE OF ROOT MEDIA

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Heat Exchanger Joule-Thomson Transient Cryogenic Refrigeration. Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

PCM-module to improve hot water heat stores with stratification: first tests in a complete solar system

AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Dynamic performance of a novel dew point air conditioning for the UK buildings

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Study on Drying Shrinkage Strain and Moisture Transfer in Concrete with Finish Coating Materials

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

Residential Building Walls and Environment in Amman, Jordan

Stability of Inclined Strip Anchors in Purely Cohesive Soil

Transcription:

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products Bakalis S.*, Giannakourou M.C. and Taoukis P. School of Chemical Engineering, National Technical University of Athens, Greece. Email: sbakalis@chemeng.ntua.gr; mgian@orfeas.chemeng.ntua.gr; taoukis@chemeng.ntua.gr ABSTRACT The effect of storage and cooking conditions on the safety of meat products has been included in risk assessment simulations. A large number of home devices were measured. Refrigerator temperatures varied from 2 to 12ºC, while ovens showed a variation of ±15 ºC and of ± 1 W/m 2 K in heat transfer coefficient at the same nominal temperature. Using a Monte Carlo simulation, the probability distribution of E. coli O7:157 was obtained. Keywords: Keywords: Temperature distribution, Monte Carlo, storage, cooking INTRODUCTION Meat products are highly perishable foods which unless correctly stored, processed, packaged and distributed, spoil quickly and may potentially become unsafe due to microbial growth. Systematic management of meat product safety via HACCP includes raw material selection, control of conditions during processing and distribution. The latter is the weaker link of the system. Conditions during transportation and at the retail level are out of manufacturer s direct control and often deviate from specifications. Application of an optimised quality and safety assurance system for the chilled distribution of fresh meat and meat products requires continuous monitoring and control of storage conditions, from production to consumption. A few investigators have studied storage conditions in commercial and in consumer storage systems. Laguere et al., (22) reported temperature distributions from 119 refrigerators in France. The authors concluded that 26% of the domestic refrigerators operated at a temperature higher than 8 C (which is the regulatory requirement for perishable foods in France). In a review of the chilled chain James and Evans, (1992) identify the points of potential hazard. In accordance with the previous researchers, the authors of this study conclude that it is possible that consumers abuse food products. Although there are studies about the storage conditions of perishable foods in domestic and commercial refrigerators, it appears that there is a lack of data about domestic cooking devices. The objective of this study was to investigate risk of microbial growth due to the uncertainties during storage and cooking of meat products. More specifically within this study we built a database of temperature distributions during storage. Temperature as well convective heat transfer coefficients were obtained for domestic ovens. The measured distributions were used in a Monte-Carlo simulation to obtain the probability distribution of E.Coli O7:157. * To whom correspondence should be addressed

MATERIAL AND METHODS The chilled chain considered is shown in Fig. 1. Prior to distribution centre the products are usually stored under well-controlled conditions (James 1992) and were not considered in this study. In collaboration with local companies temperatures were measured using loggers in 25 retail locations throughout Greece. Although the data obtained up to now, are not enough to obtain statistically significant information about the temperature distribution, it was possible to obtain preliminary data about the storage conditions in retail storage conditions. As the work continues a better approximation of the temperature distribution will be obtained. Retail Refrigerators Consumer refrigerators Consumer Oven Distribution centre Initial microbial distribution () Microbial distribution after storage (Nf) Fig. 1 Chilled chain considered Final Microbial distribution (Nc) Temperature distributions were measured in 11 home refrigerators. Computer downloadable, self contained, miniature temperature loggers (Cox Tracer, Belmont, NC, USA) were used to measure temperature in the upper, middle and bottom tray as well as in the door of the refrigerator. Temperatures were also measured in 4 domestic ovens using a K type thermocouple attached to a temperature logger (Hobo, MA, USA). Another thermocouple was inserted to a stainless steel block having dimensions and shape similar to a piece of meat. Heat transfer coefficient was estimated from the recorder temperatures using the lumped mass approximation. In order to estimate the temperature history during roasting in more realistic conditions a mathematical model was developed and solved for a burger like geometry. The main assumption in the model was that the moisture diffuses reasonably fast to the surface where it evaporates. A similar model has been developed by Huang and Mittal, (1995). The equations were as follows: T 2 C p k T (1) t using the boundary conditions: at the centre n (2) kt dm at the surface n kt ht T H vap (3) dt

Initially the temperature was considered uniform and equal to 1 C. A finite element scheme was used to solve eq. (1). The physical properties of the cooked materials were considered constant with time and were found from Huang and Mittal (1995). RESULTS AND DISCUSSION Temperature and heat transfer coefficient distributions In Fig. 2 temperature variation versus time is shown for a typical retail refrigerator. From Fig. 2 one can see that although variation is quite high, it does not appear that there is any temperature abuse of the food stuff. Although the sample was not large enough to make statistically significant conclusions, from the obtained data it appeared that storage in the studied retail refrigerators did not result in temperature abuse. 4 Tempe rature ( o C) 3 2 1-1 4 6 8 1 12 time (min) Fig. 2 Temperature distribution in a typical retail refrigerator 15% 23% 8% 28% 26% < 4 C 4 C<T< 6 C 6 C<T< 8 C 8 C<T< 1 C 1 C<T< 12 C Fig. 3 Distributions of average temperature in domestic refrigerators In Fig. 3 distribution of average temperature obtained from 11 domestic refrigerators is shown. In few refrigerators temperatures even bellow C was recorded. Opening the refrigerator resulted in sudden temperature rise to 12C and a subsequent fall to the initial temperature in less than 15 min. Highest temperatures, as it was expected, (typically about 1C) were recorded in the door of the refrigerator. Although temperature variation with respect to the remaining position was significant, it was not possible to obtain a concise conclusion. In some refrigerators the lower temperature was observed in the middle position, while in others in the upper tray. In all cases though there was a difference of more that 5C between different positions inside the refrigerator. For the Monte-Carlo simulation an average temperature was used. In Fig 4. distribution of average temperatures in domestic ovens is shown for a nominal setting of 19 ºC. In Fig. 5 Distributions of heat transfer coefficients are shown for the same ovens. The distribution of heat transfer coefficient appears to be bimodal. This was not to our surprise. Some consumers did not use the fan (or there was not one) resulting in a heat transfer controlled by natural convection. This heat transfer coefficient (approximately equal to 8 W/m 2 K) is represented from the smaller peak.

When forced convection was used the mean value of the heat transfer coefficient was 25 W/m 2 K. 4 6 5 3 Frequency 4 3 2 1 Frequency 2 1 14 15 16 17 18 19 2 21 22 5 1 15 2 25 3 35 Oven Temperature ( o C) h (W/m 2 K) Fig. 4 Distributions of average temperature in domestic ovens Fig. 5 Distributions of heat transfer in domestic ovens Finite element Modelling As it was previously mentioned a finite element model was built in order to predict temperature histories during cooking. The model was evaluated by comparison of temperatures measured in the centre of a burger from the local market with numerical prediction. A number of trials were performed. As one can see from Fig. 6 the model seems to be in good agreement with the experimentally measured temperatures. A central composite design was used to obtain a relationship of the equivalent processing time, F, for E. Coli at 121 ºC with the actual oven temperature and the convective heat transfer coefficient, for 2 min of cooking at a setting of 19ºC. The dependence is shown in Fig. 7. As it was expected higher oven temperatures and heat transfer coefficients result in higher equivalent processing times (F values). Temperature (oc) 12 1 8 6 4 2 5 1 15 2 25 Time (s) 1st experiment 2nd experiment simulation Fig. 6 Comparison of numerically predicted and experimentally measured temperature h (W/m2K) 3 F (min) 2 1 17.35 15.62 13.89 12.15 1.42 8.69 6.96 5.22 3.49 1.76 14 16 18 2 22 T (oc) Fig. 7 Effect of oven temperature (Tc) and heat transfer coefficient, (h) on equivalent heating time(f)

Monte Carlo Simulation In order to account for the uncertainties in the chilled chain a Monte Carlo simulation was used to estimate the probability of E.Coli O7:157. Growth and inactivation rates of the microorganism were obtained from ComBase (http://www.combase.cc). A distribution of E.Coli O7:157 was assumed in the initial product. Storage of 5 days in retail and domestic refrigerators was considered (Previous data for the retail stage, from Taoukis et al.,1998, was used as relevant data collection is in progress) In Fig. 8 probability distributions after each step of the chain after 15, runs are shown. The number of runs did not appear to have an effect on the resulting distributions. Although cooking resulted in a dramatic reduction of concentration of E:Coli, one can see that under some extreme conditions relatively high concentration of E:Coli might occur. The occurrence of E:Coli in the centre, i.e. in a mass of 25 g, was also estimated. The probability of the centre to have more than 1 3 cfu/g E:Coli was about 1%, representing a considerable hazard for the consumer health. Frequency 7 6 5 4 3 2 1 Initial After Storage Final Product -1-5 5 1 log(microbial Concentration) Fig. 8 Microbial Distribution in various steps of the chilled chain CONCLUSIONS The chilled chain for meat products was investigated. Temperature distributions were obtained for domestic and retail refrigerators. In retail refrigerators temperature it did not appear to be a temperature abuse of the products. Temperatures in different positions in domestic refrigerators varied more 5ºC. Opening the refrigerator resulted in a sudden increase of the temperature (up to 12ºC). The time needed for the temperature to return to the normal level is approximately 15 min. Measurements in consumer ovens indicated that there is a wide variation of temperature and heat transfer coefficients. A Monte Carlo simulation was used to obtain the probability distribution of E.Coli O7:157. The results showed that inappropriate storage and cooking conditions might result in hazard for the consumer health.

ACKNOWLEDGEMENTS This study has been partly carried out with the financial support of the Commission of the European Communities, specific RTD program Quality of Life and Management of Living Resources, Key Action 1-Health Food and Environment, Project N QLK1-CT22-2545 It does not necessarily reflect the Commission s views and in no way anticipates its future policy in this area. Information on the project can be found at http://smas.chemeng.ntua.gr NOMECLATURE Density (kg/m 3 ) Cp Specific heat (k/(kg K)) T Temperature (ºC) T Oven temperature (ºC) T f Refrigerator Temperature (ºC) M Mass of evaporated water (kg) k Thermal conductivity Hvap Latent heat of vaporisation of water N Microbial concentration (gfu/g) REFERENCES 1. Huang E. and Mittal G.S. Meatball Cooking Modelling and Simulation. J. Food Eng.24, 87-9 1995 2. James SJ, Evans J. Consumer handling of chilled foods: temperature performances. Int J Refrig 1992;15:299 36. 3. Onrawee Laguerre*, Evelyne Derens, Bernard Palagos, Study of domestic refrigerator temperature and analysis of factors affecting temperature: a French survey, International Journal of Refrigeration 25 (22) 653 659. 4. Taoukis, P.S., Bili, M., and Gianakourou M. (1998). Application of shelf life modelling of chilled salad products to a TTI based distribution and stock rotation system. Acta Hort. 466: 131-14.