INSTALLTION FOR THERMOSTATIC VALVES

Similar documents
MINIATURE THERMOSTATIC VALVE

INSTALLATION FOR THERMOSTATIC VALVES

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

INSTALLATION INSTRUCTIONS

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

Thermostatic Concealed Shower Valve

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Thermostatic Valve and Trim

Installation. S Series Navigator Thermostatic Mixing Valve

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

INSTALLATION INSTRUCTIONS

Installation Instructions

ARIN THERMOSTATIC SHOWER SYSTEM

CORALAIS BODYSPA BATH AND SHOWER FAUCET

PL-004-SS. * Proper water pressure is required for simultaneous operations

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Installation S

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Installation S

Installation S

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Installation S

Installation Instructions

Inta City Concealed Shower Mixing Valve CT80010CP

Enzo Concealed Shower Mixing Valve

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Avensys Avensys FIN EST SLO RUS UAE

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Installation Guide ASME A ANSI A117.1 CUPC / IAPMO LISTED / ADA COMPLIANT. Engineering Excellence

INSTALLATION INSTRUCTIONS

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Avensys Avensys FIN EST SLO RUS UAE

Installation S

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

Butler Mill and Brassworks Ltd. Exposed 1/2 Thermostatic Valve Installation Instructions

Telo Shower Mixing Valve TL10016CP

Elite Primer Baldor Series External Pond Pump

INSTALLATION INSTRUCTIONS

TIMES SQUARE TWO-HANDLE THERMOSTAT

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Thermostatic Shower Valves Installation Guide

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

Installation Instructions

16 OUTDOOR MISTING FAN

B.I.C.A Built-In Coffee Appliance

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

INSTALLATION INSTRUCTIONS

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

Mio Concealed Shower Mixing Valve MI40010CP

Deluge Concealed Shower Mixing Valve DL40010CP

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL

INSTALLATION INSTRUCTIONS

Thermostatic Bar Valves

Installation Instructions. Starck

INSTALLATION AND INSTRUCTION MANUAL

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Installation & Operating Instructions

INSTALLATION INSTRUCTIONS

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

Model H1011.8/H1011.8HPS Water Cooler

CHAMPION PUMP OWNER S MANUAL

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

SuperKlean Washdown Products

Installation Instructions / Warranty

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Installation, Operating and Maintenance Guide

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Thermostatic bar mixer valve with adjustable head Installation guide

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Thermostatic Deck-Mounted Bathtub Mixer Installation Guide

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

Audi-Larm Audible Alarm

INSTALLATION INSTRUCTIONS

1/7 SPOUT INSTALLATION

Kiko Bath Shower Mixing Valve KK90015CP

Product Description and Measurements. Thank You. Prior To Installation Steps. Waterfall Faucet Installation

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Installation & Service Manual

Installation Instructions. Hansgrohe S 15721XXX

gas Understanding Gas Appliance Conversions READ ALL INSTRUCTIONS

Transcription:

SS-TH1000 ½ THERMOSTATIC VALVE SS-TH3000 ¾ THERMOSTATIC VALVE SS-TH2000 ½ THERMOSTATIC VALVE WITH BUILT IN VOLUME CONTROL SS-TH4000 ¾ THERMOSTATIC VALVE WITH BUILT IN VOLUME CONTROL Features: Ability to pre-select water temperature thus conserving water Compensates for water pressure fluctuations preventing scalding Safety button at 100 F prevents accidental scalding High flow rates allow for multiple shower applications Listed by IAPMO, CSA, NSF, and other municipalities Specifications: o Operating pressure is 20 PSI to 72 PSI o When pressure is higher than 72 PSI a pressure reducer (fitted before the valve) is required. o Temperature range is 50 F to 180 F o Recommended setting is 29 PSI and 149 F Note: Note: DO NOT USE PLUMBER S PUTTY ON ANY OF THE BRASS COMPONENTS This will cause the finish to tarnish and void the warranty. A non-corrosive Alkoxy Silicone is recommended. DURING SWEATING OF LINES DO NOT OVERHEAT CASTING Overheating may cause damage to internal mechanism and void the manufacturer s warranty as well as increase the risk of scalding. COPPER ADAPTORS MAY BE REQUIRED TO COMPLETE YOUR INSTALLATION Shipping weight: 4 lb (SS-TH1000/3000) or 5 lb (SS-TH2000/4000) Shipping dimension: 7 x7 x3.5 (SS-TH1000/3000) or 8 x7.5 x6 (SS-TH2000/4000) Separate wall stops/shut off valves/volume controls (SS-TS150 or SS-TS200) may be needed in conjunction with this valve. A thermostatic valve s only function is to mix temperature. Diagram 1: Flow Rate Vs. Pressure Rev. 10/17 P a g e 1

Valve Installation 1. Flush the lines of all dirt and debris. Failure to completely flush the lines will cause valve failure and will void the manufacturer s warranty. 2. Fit the valve on the wall without removing the plastic cover on the control spindle. Turning the control spindle will change the temperature setting which is pre-calibrated at the factory. 3. Connect the hot water supply to the left inlet of the valve (hot marked with red paint) and cold supply to the right inlet (cold marked with blue paint). 4. Use the Plastic Mudguard (1) (part of the package) to position the Valve (2) in the wall. This is done by checking the markings on the mudguard for the minimum/ maximum settings which are 1 1/2 to 2 1/8 from the center of the valve inlets to the finished wall. Diagram 2: Plastic Mudguard 5. Connect the outlet pipe. Install tile stops/volume controls between the thermostatic valve and each device to be operated. See Diagram 8 for sample installations. NOTE: Water temperature from the bottom outlet will be slightly colder than water temperature from the top outlet. Trim Installation (see Diagram 4) 1. Screw Temperature Control Dome (1) and Volume Control Dome (9) (where applicable) onto valve. NOTE: Temperature Control Dome (1) has a larger opening than Volume Control Dome (9). 2. Slide the Thermostatic Face Plate (3) onto the valve by sliding over the Temperature Control Dome (1) and Volume Control Dome (9) (where applicable) and hold in place. 3. Screw Thermostatic Face Plate Lock Ring(s) (4) into Dome Sleeve(s) (2). 4. Lock the Thermostatic Face Plate (3) securely against the wall by screwing Dome Sleeve(s) (2) with Thermostatic Face Plate Lock Ring(s) (4) onto Temperature Control Dome (1) and Volume Control Dome (9) (where applicable). 5. Ensure Temperature Limit Stop Ring (5) is installed with red dot at 12 o clock position. 6. Install Temperature Control Post (6) onto valve with push button at 12 o clock position and install Temperature Control Handle (8) onto Temperature Control Post (6). Install Volume Control Post (10) onto valve and install Volume Control Handle (12) onto Volume Control Post (10). NOTE: Some heavier lever handles come with friction washers to prevent rotation due to gravity. The thinner of these washers is for use with this valve when needed (see Diagram 3). P a g e 2

Diagram 3 SS-TH1000 or SS-TH3000 Diagram 4: Representative Trim SS-TH2000 or SS-TH4000 Parts Checklist SS-TH1000 or SS-TH3000 (SS-TH2000 or SS-TH4000) Carefully remove all parts from the box. The following parts should be included. Item # Description Qty. Item # Description Qty. 1 Temperature Control Dome 1 7 Temperature Control Screw 1 2 Dome Sleeve (raw brass) 1 (2) 8 Temperature Control Handle 1 3 Face Plate 1 9 Volume Control Dome 0 (1) 4 Lock Ring 1 (2) 10 Volume Control Post 0 (1) 5 Temperature Limit Stop Ring 1 11 Volume Control Screw 0 (1) 6 Temperature Control Post 1 12 Volume Control Handle 0 (1) P a g e 3

Temperature Setting The delivered temperature of the valve varies depending on the temperature of the supplied hot water. The valve is factory set at a supplied temperature of 149 F under balanced pressures. Depending on your preferred hot water temperature setting, it may be necessary to adjust the calibrations of the valve. The limit override button is preset at 100 F and can be adjusted as described below. 1. Select 100 F on the control handle. 2. Without turning the handle, remove the handle by unscrewing the screw and pulling off (screw may be concealed and/or fastened with set screws). 3. Use a thermometer to check the delivered temperature on one of the outlets. 4. Adjust water temperature to 100 F by hand turning the cartridge stem slowly left or right. 5. Ensure that the temperature limit stop-ring is installed with red dot at 12 o clock position. 6. Install the handle back on the valve with the push button at the 12 o clock position. Diagram 5: Temperature Limit Stop Ring RED DOT Removal and Maintenance of Cartridge(s) (see Diagram 6) This thermostatic cartridge has screens to prevent dirt and unwanted particles from damaging the valve. Clogged screens can cause reduced flow and inefficient temperature mixture by the valve. You can easily clean the screens by following the instructions below. 1. Remove the trim by following the Trim Installation steps above in reverse. 2. Shut off the water inlets by tightening the two screws at the two check stop valves. 3. Unscrew Thermostatic Cartridge (2) with a 30mm socket wrench or other adjustable wrench in a counter-clockwise direction and gently pull out. 4. Clean the screens and rinse with water. If necessary, soak in a 50/50 mix of white vinegar/ water or a de-scaling agent until all dirt is dissolved. Grease the o-rings with a silicone based grease and wipe the housing with a wet cloth before reassembling. 5. Reassemble the valve by reversing these instructions. Make sure the red dot on the temperature limit stop ring and push button on the handle are both aligned in the 12 o clock position. NOTE: Temperature may need to be reset as per instructions above. NOTE: To prevent the handle from accumulating mineral build up which can cause the handle to lock up, the handle must be turned on an occasional basis. Diagram 6: Cartridge Removal/Check Valve Removal Parts List SS-TH1000 or SS-TH3000 (SS-TH2000 or SS-TH4000) Item # Description Qty. 1 Valve Body 1 2 Thermostatic Cartridge 1 3 Volume Cartridge 0 (1) 5 Service Stop Nut 2 6 Check Valve 2 P a g e 4

Troubleshooting Malfunction Cause Remedy Cannot regulate temperature Dirt in check valves Hot and cold water do not mix Water not hot enough / Water too hot Temperature selected on handle is different than actual water temperature Water supply reversed Valve installed upside down Lack of water pressure at one of the inlets Blocked shower head Debris in check valves Valve not properly calibrated Water heater setting incorrect Debris in check valves Valve not properly calibrated Reverse hot and cold supply lines Reverse valve Correct water pressure at source Remove shower head and clean debris. If necessary, soak in a 50/50 mix of white vinegar/ water or a de-scaling agent until all dirt is dissolved. Calibrate valve following instructions on page 4 Adjust water heater temperature setting Calibrate valve following instructions on previous page Uneven hot & cold water pressure Check and adjust water pressure for both hot & cold supply lines Handle does not turn Mineral build up Remove and clean cartridge following instructions above Low water pressure Low water pressure Check and adjust water pressure at source Leaking shower head Valve body too deep into wall Debris in cartridge Debris in check valves Blocked shower head Fault cartridge in wall stop/ volume control The measured rough in or finished wall surface is incorrect Remove and clean cartridge following instructions above Remove shower head and clean debris. If necessary, soak in a 50/50 mix of white vinegar/ water or a de-scaling agent until all dirt is dissolved. Repair or replace cartridge in wall stop/ volume control Install an extension kit: SS-EXT41 for SS-TH1000 or SS-TH3000 SS-EXT51 for SS-TH2000 or SS-TH4000 P a g e 5

Diagram 7 Dimensional Drawings Diagram 8: Sample Layouts Thermostatic Valves P a g e 6