SafeLine SL6 THE NEXT GENERATION OF

Similar documents
SafeLine OCC MANUAL. SafeLine Product 121,6 59,25 22,1. Otis Connection Cabeling. Option for installing SafeLine on an Otis REM5 equipped lift.

ELECTRICAL COMPONENTS REMOTE LIFT ALARM

Products compliant with the following standards and regulations: EN81/70, EN 81/28 and EN 81/72. Lead-free manufacturing. Reduced energy consumption

OPEN THE DOOR TO INNOVATION. 2N ELEVATOR SYSTEMS - Emergency communication devices for any lift.

600 Range Dialer Installation Manual. Version 1.0

Memcom Emergency Telephone

SC-F3G User Manual 1.0

System solutions for every lift. Everywhere. Lift Emergency Call Systems

Octalarm-T: the latest in future-proof industrial alarm diallers

AVCOM System Installation Instructions

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

Monitoring Solutions

S3 Sim Secual Alarm system with GSM transmitter

System solutions for every lift. Everywhere. Lift emergency EasyGate PRO and Lift1

Memcom + Emergency Telephone

Security designed for your lifestyle

M2500 Engine Controller Installation Manual

SCAN200E USER S MANUAL

SCAN20 Series Gas Detection Controller

Modular Fire Panel 5000 Series Just as flexible as your plans

PERMACONN PM1030 Includes DI300. Installation Manual

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

COMMUNICATOR ET08 / ET081

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

The New Standard In Safety

PiSector GSM Cellular Wireless Alarm System

Intelligent Security & Fire Ltd

FIRElux Emergency Lighting

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Specialists in communications for the elevator industry

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Contents. Contents

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

EasyAlarm ELEVATOR LEITRONIC AG

EC II GSM SE User Manual

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

IP & SMS Alarm Communicator

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

RACK MONITORING SYSTEM RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra

DSE ELECTRONIC SIRENS Advantages & Functions

Basic Installation Manual

GSM RFID VOICE Alarm System

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

MOBILE CALL GSM Alarm System User s Manual

IC60 Sintony 60 Intrusion Control Panel

Wireless Internal Siren System Installation Guide

HRX Technical Manual. Version 1.2

HELPY CONTROLLER QUICK GUIDE

DESCRIPTION INSTALLATION

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

SMS GSM Alarm Messenger

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

The future of security, secured IP by security professionals, for the professional security industry

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

CCU Family of Modules

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

The Elevator Control System

VPS3 Installation Manual

SI120 Guarto Easy I. Alarm system. Fire & Security Products

CODESEC FIRE ALARM SYSTEMS. security technologies

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

AutroVoice voice alarm system AUTROVOICE VOICE ALARM. Loud and clear information

Cold chain monitoring technologies. Facility monitoring

REVA Linen Finish Car Operating Panel

Shenzhen SUNSKY Technology Limited

System. For a better understanding of this product, please read this user manual thoroughly before using it.

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

NON-MONITORED EMERGENCY CALL SYSTEMS

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

Typical applications include the vibration detector. Detection of vibrations and shocks

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS.

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

Intelligent Addressable Fire Alarm System

Oracle Retail Furniture Retail System (FRS) Pricewriter to Xmargin Guide Release October 2015

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

Elemec3. Networked Public Address and General Alarm System (PA/GA)

wireless. web-based. worthy of the name RACO.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Kwêbeam GSM/Interface/Repeater Module

Transcription:

Lift emergency telephones SafeLine SL6 THE NEXT GENERATION OF LIFT Emergency telephone systems SafeLine SL6 The complete lift emergency telephone and fire communication system in accordance with EN81-28, EN81-70 and EN81-72

SafeLine - Quality talks. SafeLine was founded in 1995 with the motto For lift people, by lift people. Since then we have grown, not only to become the leading company in Scandinavia, but also one of the fastest growing companies in lift communications globally. The core business is based on our proprietary lift emergency telephone systems, floor information displays and replacement parts for lifts. Because we control the entire production chain in Sweden - from development, testing and design to manufacturing and technical support - we are able to deliver products of the highest quality both in terms of reliability, longevity and technical standard. SafeLine s products are compatible with all leading lift systems. We are represented in over 35 countries. In 2012 SafeLine was appointed the Super company Award for the sixth consecutive year. Copyright 2013 SafeLine Sweden AB All rights reserved under International Copyright Conventions. No part of the contents of this brochure may be copied, reproduced or transmitted in any form or by any means, or translated into another language or format, in whole or part, without written consent of SafeLine Sweden AB. This publication is for general informational purposes only and we reserve the right at any time to alter any product design and specifications. No statement this publication contains should be construed as a warranty or condition, express or implied, as to any product, including its fitness for any particular purpose or quality, or as any modification or representation of the terms of any purchase agreement. SafeLine and SL6 are registered or unregistered trademarks of SafeLine Sweden AB and/or its affiliates. Other names may be trademarks of their respective owners.

SafeLine SL6 Features SafeLine SL6 The complete lift emergency telephone and fire communication system in accordance with EN81-28, EN81-70 and EN81-72. Advantages: Internal bus system only two wires plus supply voltage Compact and robust metal housing Connect up to 6 voice stations with internal button (NO) or external button (NO/NC) Internal and/ or external pictogram in accordance with EN81-70 NGN safe with compatibility for VoIP Support for fire communication in accordance with EN81-72 Integrated 12V emergency battery backup Features: PSTN/ GSM with redundancy Emergency call receipt On-site recording and adaptation of voice message in car and to operator on alarm Automatic battery condition test Automatic microphone and speaker self-test Test alarms in accordance with EN81-28 Up to 4 phone numbers can be programmed to ensure alarm is received Adjustable delay for answering incoming calls Adjustable speaker volume Inputs for alarm filtering Main unit

About SafeLine SL6 Internal bus system Through the usage of an internal bus system for communication between the main unit and voice stations, flexibility is maximized and cabling is kept to a minimum. Only 2 wires plus supply voltage is needed for each voice station. No additional interface board is required for connecting up to 6 voice stations in car, on car roof, in car pit, machine room or on the floors. The voice units are available in 18 different models for easy adaptation to most situations and needs. High redundancy SafeLine SL6-GSM makes it possible to make use of both PSTN and GSM interfaces at the same time and allow them to work together. This built-in fallback function enables an automatic switch to GSM in case of landline outage, or vice versa all to ensure highest possible level of availability and dependability. The integrated battery backup system ensures continued operation despite a power outage. A condition test is performed on a regular basis and the unit will send an alarm if the battery needs to be replaced. Future-proof The system is NGN-safe which enables compatibility with VoIP equipment today as well as tomorrow. It uses the latest available technology and state-of-the-art design.

About SafeLine SL6 Modem function SafeLine SL6 GSM can be used as a GSM modem when connected to a controller. The modem function can be used for many purposes, such as remotely alter setup of the controller, monitoring of the entire lift, or to upload needed files and settings to the connected equipment. A standard USB cable or programming cable can be used to connect a controller or other suitable equipment to the SafeLine SL6 unit. The modem function uses the new open standard for modem communication, supported by major controller manufactures. Canopen-Lift interface SafeLine SL6 supports CANopen-Lift with an optional interface board. CANopen-Lift is an industry standard to allow plug-and-play compatibility of lift equipment. The CANopen-Lift interface on SafeLine SL6 enables it to communicate and send information from the controller. All configuration can be made with the standard CANopen-Lift configuration tool CANwizard. Fire communication SafeLine SL6 can be used as a fire fighting intercom as well as an emergency telephone. Up to a maximum of six stations can be used, with a combination of emergency telephone and fire stations, allowing for additional locations in the building if required. SafeLine SL6 is a fully featured but compact emergency telephone and fire fighting intercom unit, with all features required to comply with the EN81-28, EN81-70 and EN81-72 standards.

SL6 car station, flush mounted SLB-Rec is a voice station for SL6 without pictograms for flush mounted installation. The front plate is mounted using four screws. LED s for external pictograms and an emergency button can easily be connected using the included RJ45 cable. SL6 car station with emergency LED, flush mounted SLB-Rec-LED is a SL6 voice station with emergency LED for flush mounted installation. The front plate is mounted using four screws. LED s for external pictograms and an emergency button can easily be connected using the included RJ45 cable. SL6 car station with pictograms, flush mounted SLB-Rec-Pic is a SL6 voice station with pictograms for flush mounted installation and fulfills the requirements for EN81-28 and EN81-70. The front plate is mounted using four screws. SL6 car station with pictograms and button, flush mounted SLB-Rec-Pic-But is a SL6 voice station for flush mounted installation. It has got integrated pictograms as well as emergency button and fulfills the requirements for EN81-28 and EN81-70. The front plate is mounted using four screws.

SL6 car station, surface mounted SLB-SM is a voice station for SL6 without pictograms for surface mounted installation. LED s for external pictograms and an emergency button can easily be connected to the included RJ45 cable. The frame is mounted directly onto the car wall using two screws. SL6 car station with emergency LED, surface mounted SLB-SM-LED is a SL6 voice station with emergency LED for surface mounted installation. LED s for external pictograms and an emergency button can easily be connected using the included RJ45 cable. The frame is mounted directly onto the car wall using two screws. SL6 car station with pictograms, surface mounted SLB-SM-Pic is a SL6 voice station with pictograms for surface mounted installation and fulfills the requirements for EN81-28 and EN81-70. The frame is mounted directly onto the car wall using two screws. SL6 car station with pictograms and LED frame, surface mounted SLB-SM-Pic-Light is an SL6 voice station for surface mounted installation. It has got integrated pictograms and emergency lightning. The built-in LED rail can be placed in three different directions within the frame, making sure that the operating panel is lit, regardless of where the unit is mounted. The frame is mounted directly onto the car wall using two screws. SL6 car station with pictograms and button, surface mounted SLB-SM-Pic-But is a SL6 voice station for surface mounted installation. It has integrated pictograms as well as emergency button and fulfills the requirements for EN81-28 and EN81-70. The frame is mounted directly onto the car wall using two screws.

SL6 car station, mounted behind COP SLB-COP is a voice station for SL6 suited for installation behind the car operating panel, where welded bolts can be used. Alternatively the unit is mounted with the adhesive tape which is included as standard. An external pictogram and emergency button can easily be connected through a screw connector on the back of the unit SL6 car station without front plate, mounted behind COP SLB-COP2 is a voice station for SL6 suited for installation behind the car operating panel, where welded bolts are not suitable. The unit is mounted with the adhesive tape which is included as standard. An external pictogram and emergency button can easily be connected through a screw connector on the back of the unit. SL6 car station, microphone and speaker separated, mounted behind COP SLB-COP-Sep is a voice station for SL6 suited for installation behind the car operating panel with limited depth to spare. The unit is delivered on a plate for COP mounting with the speaker on the side to minimize the unit s depth. SL6 voice station for car top/lift pit SLB-RD is a voice station for SL6 that can be used as a voice station on the car top or lift pit, or as part of a fire intercom system. SL6 voice station for car top/lift pit, with button SLB-RD-But is a voice station for SL6 that can be used as a voice station on the car top or lift pit, or as part of a fire intercom system. The integrated button enables an emergency call to be established from the shaft.

SL6 fire car station with key switch, flush mounted Flush mount key switch for use with SafeLine SL6 Fire products. Triangular fire switch mounted on stainless steel front plate. SL6 fire car station, flush mounted Flush mount serial bus fire station for use with SafeLine SL6 product, with built-in talk button and fire logo as required by the standards. SL6 voice station, firemans intercom Flush mount serial bus fire station for use with SafeLine SL6 product, with built-in talk button as required by the standards. Custom metalwork finish with company logo available on request. SL6 voice station, firemans intercom with key switch Flush mount serial bus fire station for use with SafeLine SL6 product, with built-in talk button as required by the standards, complete with triangular fire switch. Custom metalwork finish with company logo available on request.

SafeLine SL6 facts Inputs and outputs USB connection for programming Serial RS232 connection for programming RJ12 connection for analogue phone 2 optically isolated inputs: 10-30V, 5 ma (NO/NC) 2 relay outputs: 2A 30V DC / 0,5A 125V AC Output for emergency siren 12V (max 100 ma) Output for emergency light 12V Features PSTN/ GSM with redundancy Emergency call receipt On-site recording and adaptation of voice message in car and to operator on alarm Automatic battery condition test Automatic microphone and speaker self-test Test alarms in accordance with EN81-28 Up to 4 phone numbers can be programmed to ensure alarm is received Adjustable delay for answering incoming calls Adjustable speaker volume Inputs for alarm filtering

?? Article number: SLB-IF1 Monitoring card Article number: SLDL 12V Piezo buzzer Article number: Siren01 Hearing loop Article number: HL1 / HL1-SM / HL2 Emergency light Article number: LED-SM / LED-Rec Standalone pictogram Article number: Pic-SM / Pic-Rec

SafeLine Europe Blvd de la Woluwe 42, 1200 Brussels Phone: +32 (0)2 762 98 10 E-mail: info@safeline.se SafeLine Elevator Parts UK 3 Evegate Park Barn Station Road Smeeth Ashford Kent TN25 6SX Phone: +44 (0)1303 813414 info@safelineelevatorparts.co.uk SafeLine-Deutschland GmbH Westfalenstraße 22a D-51688 Wipperfürth Deutschland Phone: +49 (0)2267-8 67 96 63 (Büro) info@safeline-deutschland.de SafeLine Denmark Erhvervsvej 19 DK - 2600 Glostrup Phone: +45 44 91 32 72 info-dk@safeline.se SafeLine Sweden AB Antennvägen 10 135 48 Tyresö Phone: +46 (0)8 447 79 32 Support: +46 (0)8 448 73 90 info@safeline.se www.safeline.eu