INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

Similar documents
INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD CONDENS

INSTALLATION AND OPERATING INSTRUCTIONS TRO EVOLUTION BH

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

INSTALLATION AND OPERATING INSTRUCTIONS AVANTTIA

INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HFM

Light oil burners. One stage operation

INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HFDX

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Light oil - kerosene burner

Light oil / kerosene burner

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Oil burners Brûleurs fioul Stookoliebranders

INSTRUCTION MANUAL FOR OIL BURNER MODELS

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

INSTRUCTION MANUAL FOR OIL BURNER MODELS

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

TWO STAGE HEAVY OIL BURNERS

Forced draught gas burner

WHE 2.24 / WHE 2.24 FF

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTALLATION AND OPERATING INSTRUCTIONS

Installation & Maintenance Manual

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

1 VICTRIX ZEUS Superior kw I features

Parts Available from

USERS GUIDE. LOGIC+ Combi 24, 30, 35

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Logic+ Combi

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Forced draught gas burner

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

GB24 & GB30. User Manual

Single stage operation oil burner

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

VELA COMPACT INSTALLATION USE AND MAINTENANCE

Installation, operating and servicing instructions

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

USERS GUIDE 24, 30. For installation guide see reverse of book

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

ST 40 Oil Burner. Installation & Maintenance Manual

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Infrared Diesel Heater

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

RMG IT ES PT GB FR BE

BIX B-One 100 kw INSTALLATION GUIDE

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Heating Equipment. gas boilers RX GB. installation and servicing instructions

1. GENERAL SAFETY RULES

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

User Manual for model

Capri B Cast iron combination oil-fired boiler with water tank

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

User's Instructions. Alpha CB50

RODI DUAL RODI DUAL HR

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

USERS MANUAL FOR GAS BOILERS

Technical Documentation

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

OPERATING & MAINTENANCE MANUAL INDUSTRIAL DIRECT FIRED DIESEL/KEROSENE HEATERS IC 25

Single stage operation oil burner

Bithermal Wall-hung boiler with integrated heat exchanger

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

Operating instructions

INSTALLATION AND OPERATING INSTRUCTIONS AUGER FOR HOMEMADE

E-COMBI EVO E-SYSTEM EVO

BIOMASS BOILER DUAL THERM

Gas Fire Patio Heater Q9

INSTALLATION AND OPERATION MANUAL

BG2000S PRE-MIX GAS BURNER

Installation, operation and care. Pellmax UB. Burner not included Replaces:

BOSCH CONDENS 5000W ZSB18-2A

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

A/23 MFFI - A/27 MFFI

User Guide Compact-7 series

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

en Direct oil-fired space heaters HD... Operator's manual

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

C Tahiti. condensing

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

GAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models Technical information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

TAHITI CONDENSING KR 55 - KR 85

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

Power X High Power Condensing Wall-Hung Boilers

INSTALLER INSTRUCTIONS

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS CGM-04/392 ER-0170/1996

Thank you for choosing a DOMUSA TEKNIK heating boiler. You have chosen a boiler which will provide the ideal level of comfort for your home, always with a suitable hydraulic installation and oil-fired. This manual forms an essential part of the product and it must be given to the user. Read the warnings and recommendations in the manual carefully, as they contain important information on the safety, use and maintenance of the installation. These boilers are to be installed by skilled personnel only, in accordance with the legislation in force and following the manufacturer s instructions. The start-up of these boilers and any maintenance operations must only be carried out by DOMUSA TEKNIK s Authorised Technical Assistance Services. Incorrect installation of these boilers could result in damage to people, animals or property, and the manufacturer will hold no liability in such cases. DOMUSA TEKNIK informs all parties concerned that, in compliance with section 1 of the first additional provision of Law 11/1997, the responsibility for delivering packaging waste or used packaging for its proper environmental management will be that of the final owner of the product (Article 18.1 Royal Decree 782/1998). At the end of its useful life, the product must be taken to a selected collection point for electrical and electronic equipment or must be returned to the distributor at the time of purchasing a new equivalent appliance. For more detailed information on the collection schemes available, contact either the collection facilities of the local authority or the distributor where the purchase was made.

CONTENTS 1 LIST OF COMPONENTS... 2 2 CONTROL ELEMENTS... 3 3 INSTALLATION INSTRUCTIONS... 4 3.1 LOCATION...4 3.2 FLUE...4 3.3 REMOVAL OF COMBUSTION PRODUCTS...4 3.4 HYDRAULIC INSTALLATION...4 3.5 ELECTRICAL CONNECTION...4 3.6 OIL INSTALLATION...5 4 FILLING THE INSTALLATION... 5 5 COMMISSIONING OF THE BOILER... 5 6 DELIVERY AND INSTALLATION... 5 7 SAFETY CUT-OUTS... 5 7.1 TEMPERATURE SAFETY CUT-OUT...5 7.2 BURNER CUT-OUT...5 8 FUNCTIONING... 6 8.1 FUNCTIONING WITH A SANIT STORAGE HEATER...6 9 TIMER-BASED OPERATION (OPTIONAL)... 6 10 CONTROL UNIT-BASED OPERATION (OPTIONAL)... 6 11 STOPPING THE BOILER... 6 12 BOILER MAINTENANCE... 7 13 DIAGRAMS AND DIMENSIONS... 8 14 TECHNICAL CHARACTERISTICS... 8 15 ELECTRICAL DIAGRAM...10 16 SPARE PARTS LIST...11 17 BOILER'S WATER PRESSURE DROP DIAGRAMS...21 18 TROUBLESHOOTING...22 18.1 BURNER FAILURES... 22 18.2 BOILER FAILURES... 22 19 GENERAL WARRANTY CONDITIONS...23 Page 1

Jaka HFD / HFS 1 LIST OF COMPONENTS 1 2 3 4 5 6 7 8 9 10 11 1. Thermometer. 2. Heating control thermostat. 3. Safety thermostat. 4. Control unit (Optional). 5. Manometer. 6. Main switch. 7. Winter pilot light. 8. Summer pilot light. 9. Temperature cut-out pilot light. 10. Burner cut-out pilot light. 11. Burner. (Only for Jaka HFD) 2

2 CONTROL ELEMENTS 1 2 3 t bar 4 5 6 7 9 10 8 1. Thermometer: This indicates the temperature of the water in the boiler. 2. Control thermostat: This is for selecting the working temperature for water heating, and stopping the burner when the boiler reaches the selected temperature or keeping it switched on until this temperature is reached. 3. Safety thermostat: This ensures the boiler temperature does not exceed 110 ºC, by switching it off when it reaches this temperature. 4. Control unit (Optional): This optional element allows the installation temperatures to be adjusted depending on the requirements of the home and the outdoor temperature. 5. Manometer: This indicates the pressure in the installation. 6. Master switch: The "O/I" switch turns the boiler on and off. If your installation has a storage heater from the DOMUSA TEKNIK Sanit range, the " / " switch is for selecting either Summer mode (hot water only) or Winter mode (heating + hot water). 7. Winter mode pilot light: This pilot light comes on to show that the boiler is on Winter mode (Heating and DHW). 8. Summer mode pilot light: This pilot light comes on to show that the boiler is on Summer mode (Only DHW). 9. Temperature safety cut-out pilot light: This pilot light comes on to show that the boiler has switched off due to excess temperature (over 110 ºC). 10. Burner cut-out pilot light: This pilot light comes on to show that the boiler has switched off due to a burner cut-out. 3

Jaka HFD / HFS 3 INSTALLATION INSTRUCTIONS The boiler must be installed by personnel authorised by the Department of Industry in accordance with the applicable regulations and standards in force. However, the following recommendations must also be complied with when installing the boiler: 3.1 Location The boiler must be installed in a sufficiently ventilated site. 3.2 Flue This type of boiler must be connected to a flue. A flue is a fume outlet pipe able to generate a depression, which in the case of the Jaka HFS and Jaka HFD should be at least 1.5 mmca. In order for the flue to create a depression the following recommendations should be taken into account: - It should be suitably heat-insulated. - It should be fitted separately, with one flue for each boiler. - It should be vertical and have no angles of over 45º. - It should protrude one metre from the roof ridge or from any adjacent building. - It should always have the same diameter. Ideally it should be circular, and its diameter must never be less than that of the boiler outlet. However, flues must always be constructed in accordance with the installation regulations in force. 3.3 Removal of combustion products The combustion product removal ducts must be installed by qualified personnel and must comply with current legislation and standards. 3.4 Hydraulic Installation The hydraulic installation must be made by qualified personnel. The applicable installation legislation is to be complied with, and the following recommendations should also be taken into account: - The inside of the installation piping should be thoroughly cleaned before switching on the boiler. - We recommend inserting cut-off valves between the installation piping and the boiler, to simplify maintenance tasks. 3.5 Electrical connection The boiler is designed to be connected to the mains at 220 V 50 Hz, using plugs 1 and 2. Do not forget to earth the appliance. The boiler is provided with two terminals for connecting the room thermostat. To do this, remove the bridge joining terminals 3-4 and connect the room thermostat here. The boiler is designed for a quick connection to be made to the burner using a 7-pole Euroconnector. 4

3.6 Oil Installation The Jaka HFD boiler is supplied with a Domestic gas-oil burner (see model in Technical Characteristics). To install the oil line, proceed in accordance with the instructions enclosed with the burner. 4 FILLING THE INSTALLATION The installation must be provided with a fill valve for this purpose, with which it can be filled until a pressure of 1-1.5 bar appears on the manometer (5). It must be filed slowly, so that the air is released from the boiler. The rest of the installation must also be suitably drained using the air drain valves fitted for this purpose. When the installation has been filled, close the fill valve. NOTE: Do not switch on the boiler without any water in it, as this can seriously damage it. 5 COMMISSIONING OF THE BOILER In order for the guarantee to be valid, the boiler must be started up by an authorised DOMUSA TEKNIK Technical Assistance Service. The following must be complied with before starting it up: - The boiler must be electrically connected to the mains. - The installation is to be filled up with water (the manometer must indicate 1-1.5 bar). - Fuel must be reaching the burner at a pressure of not over 0.5 bar. To start up the boiler, set the master switch, the control thermostat, the timer and the room thermostat (where applicable) to the desired position. 6 DELIVERY AND INSTALLATION After the initial start-up, the Technical Assistance Service will explain to the user how the boiler functions, informing of the most important points. The installer is responsible for making clear to the user the functioning of any control or regulation device that forms part of the installation but is not supplied with the boiler. 7 SAFETY CUT-OUTS The boiler is provided with two types of operational safety cut-out: 7.1 Temperature safety cut-out This is indicated by the temperature cut-out pilot light (9). It is activated whenever the boiler exceeds a temperature of 110 ºC. To deactivate it, press the button on the safety thermostat (3) (you will first need to lift its cover). 7.2 Burner cut-out This is indicated by the burner cut-out pilot light (10). It is activated if any failure occurs in the burner or oil line. To deactivate it, press the illuminated button which lights up on the burner (11). NOTE: If either of these cut-out mechanisms is set off repeatedly, contact your nearest authorised Technical Assistance Service. 5

Jaka HFD / HFS 8 FUNCTIONING Turn the control thermostat (2) and the room thermostat (if the boiler has one) to the desired temperature. Turn the master switch (6) to "I" and the summer/winter switch to winter position " ". The burner and the pump will start up and run until the installation reaches the temperature pre-set on the control thermostat (2) (or on the room thermostat, if the boiler has one). When the installation temperature drops, the burner will start up again and perform the heating cycle. 8.1 Functioning with a Sanit storage heater The Jaka HFS boiler may be installed together with a storage heater from the DOMUSA TEKNIK Sanit range, to obtain domestic hot water. To correctly install this element, carefully follow the assembly and connection instructions enclosed with the storage heater. The boiler is equipped with a summer position/winter position selector switch. This switch can be used to choose between: - Summer position : in this position the boiler will only produce hot water as needed. The burner and the storage heater feed pump (summer pump) will be switched on until the hot water stored reaches the temperature set on the storage heater hot water thermostat. When this temperature is reached, the burner and the summer pump will switch off. - Winter position : in this position the boiler will produce hot water as needed and will also provide heating, giving priority to hot water production. 9 TIMER-BASED OPERATION (OPTIONAL) The JAKA HFS boiler can optionally be supplied with a timer, to be mounted on the main board. Both the boiler and timer are equipped with an easy installation system, consisting of a 12-pole connector (X12), as shown in the electrical diagram. Proceed as indicated in the assembly and operation instructions provided with the timer. 10 CONTROL UNIT-BASED OPERATION (OPTIONAL) The JAKA HFS boiler may be supplied with an optional Control Unit (E24 BVS). Various sensors may be incorporated to this control unit, enabling it to regulate two independent heating zones: a circuit with a mixing valve (e.g. underfloor heating), and a direct circuit (e.g. radiators). The installation can thus be adjusted to suit the needs of a particular home by measuring the outside temperature and the room temperature inside the house in each of the two heating zones. The control unit can also adjust the hot water production of a storage heater connected to the boiler, giving priority to the hot water production. Both the boiler and the control unit are provided with an quick installation system, consisting of a 12- pole connector (X12), as shown in the Electrical Diagram. Proceed as indicated in the assembly and operation instructions enclosed with the control unit. 11 STOPPING THE BOILER To stop the boiler, simply turn the master switch (6) to "O". 6

12 BOILER MAINTENANCE For the boiler to remain in perfect working order, an annual inspection should be carried out by a technician authorised by DOMUSA TEKNIK. However, - It is recommendable to thoroughly clean the boiler chamber and flue pipes once a year. - The installation pressure should be maintained between 1 and 1.5 bar. - If the boiler has been turned off for a long period of time, it should be checked that the circulating pumps are functioning correctly. To do this, remove the plug from the front of the pump so that the pump shaft is visible. If the shaft does not turn, disconnect the pump using the master switch (6). With a suitably-sized screwdriver, press the shaft down gently and turn it in both directions. Connect the selector again. 7

Jaka HFD / HFS 13 DIAGRAMS AND DIMENSIONS Jaka HFD: 455 L 190 230 95 1 1/4" IC 530 630 845 O RC 1 1/4" V 95 1/2" 90 IC: Heating outlet. MODEL HFD-30 HFD-40 HFD-50 HFD-60 RC: Heating return. MEAS. mm 385 485 585 685 V: Draining. FLUE mm 150 150 150 175 Jaka HFS: 455 L 230 95 1 1/4" IC 95 90 530 630 845 O 1 1/4" 250 RC 1/2" V 95 230 IC: Heating outlet. MODEL HFS-30 HFS-40 HFS-50 HFS-60 RC: Heating return. MEAS. mm 385 485 585 685 V: Draining. FLUE mm 150 150 150 175 8

14 TECHNICAL CHARACTERISTICS JAKA HFD/HFS 30 40 50 60 Boiler type - Low temperature heating only Rated heat output P rated kw 29 40 50 60 Useful heat output P 4 kw 28,1 39,4 50,8 60,7 Useful heat output (30%) P 1 kw 8,9 12,1 15,6 18,6 Seasonal space heating energy efficiency Ƞ S % 86 87 86 86 Useful efficiency Ƞ 4 Useful efficiency (30%) Ƞ 1 %(PCI) 91,5 94,7 94,5 94,5 %(PCS) 86,3 89,3 89,1 89,1 %(PCI) 97,5 97 96,3 96,3 %(PCS) 92,0 91,4 90,8 90,8 Auxiliary electricity consumption at full load el max kw 0,152 0,161 0,161 0,226 Auxiliary electricity consumption at part load el min kw 0,055 0,056 0,056 0,078 Auxiliary electricity consumption in standby mode PSB kw 0,003 0,003 0,003 0,001 Standby heat loss P stby kw 0,106 0,094 0,141 0,182 Emissions of nitrogen oxides NOx mg/k Wh 126 105 128 133 Heating temperature adjustment ºC 60-85 Maximum safety temperature ºC 110 Maximum pressure for heating mode bar 3 Heating water volume Lts 16,2 20,2 24,2 28,2 Water pressure drop mbar 100 204 263 327 Fume temperature ºC 213 213 208 200 Volume on fume side m 3 0,011 0,017 0,023 0,029 Maximum fume flow Kg/s 0,0132 0,0186 0,0245 0,0299 Fume pressure drop mbar 0,17 0,18 0,20 0,22 Combustion chamber length mm 300 400 500 600 Combustion chamber type - wet, with three fume outlets Burner adjustment type - ON/OFF Electrical supply - ~220-230 V - 50 Hz - 200 W Gross weight Kg 110 135 160 185 9

Jaka HFD / HFS 15 ELECTRICAL DIAGRAM X12 Brown 1 Grey 2 White Grey 3 C Pink 4 PON TC 1 Orange Black 5 6 PT TS Pink C TF3 C Purple Blue 7 8 1 2 1 2 White 9 O/I 1a 1 2a V I 2 2b Red 10 11 12 PB White Brown Red Grey Brown Y ellow Black Brown Black Brown Pink Pink Black Grey Green Brown Orange Brown Purple Blue 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TA Blue Black Blue Blue Black Black Blue N + - F 220 V N Q bc7 BV BC 1 Black Blue C Brown BC 2 M NC Tacs NO Q: Burner. BV: Hot water pump (control unit option). BC 1 : Main heating circuit pump (with control unit, direct circuit). BC2: Optional heating circuit pump (with control unit, mixed circuit). M: Valve motor (Control unit option). O/I: On/Off Master Switch. V/I: Summer/Winter Selector Switch. TA: Room Thermostat. TC: Control thermostat (on boiler). TS: Safety thermostat (on boiler). TF3: Anti-inertia thermostat (on boiler). Tacs: Hot water thermostat (on storage heater). PON: On pilot light. PB: Burner cut-out pilot light. PT: Temperature cut-out pilot light. X12: 12-terminal connector for timer or control unit (Optional). bc7: Burner control terminal nº 7. 10

16 BURNER 16.1 Assembly Fix the burner support to the boiler, then fix the burner to the support. This will allow the correct tilt of the flame tube towards the combustion chamber. Fit the intake and return tubes, inserting the oil filter in the intake tube. 16.2 Fuel instalation The "Domestic" burner is equipped with a self-extracting pump, enabling fuel intake from a tank installed at a lower level than the burner, provided the pressure difference measured with the vacuum gauge at the pump does not exceed 0.4 bar (30 cmhg). 16.3 Burner start-up Ensure there is fuel in the tank, that the oil valves are open and that there is an electric connection to the burner. Turn on the master switch. Unscrew the air bleed screw (manometer point). Then, when the valve opens, remove the photocell sensor and move it towards a light source until fuel comes out. Disconnect the burner and screw the bleed screw back in. 16.4 Adjusting the combustion conditions Observe the flame. If there is insufficient combustion air, it will be dark in colour and will produce smoke, obstructing the flue outlet. On the contrary, if there is an excess of combustion air, the flame will be pale or bluish in colour. This will reduce the performance of the boiler and it will fail to comply with anti-pollution standards, and the excess air may also hinder the ignition process. The flame should be orange in colour. If the shape of the boiler makes it difficult or impossible to observe the flame, the combustion air flow can be regulated by observing the smoke coming out of the flue. If the smoke is dark in colour, more air will need to be provided to the burner, and if it is very white, the air in the burner will need to be decreased until no smoke at all is observed. If you have a device for determining the composition of the combustion gases, this will be the best guide for flame adjustment. If not, simply follow the above indications. 11

Jaka HFD / HFS 16.5 Dimensions F' D C H I B E G F A L J K A B C D E F F' G H I J K L (mm) 292 265 140 152 215 75 98 290 ø80 205 100 100 ø90 F: Domestic D-3. F': Domestic D-4. 12

16.6 Primary air adjustment To adjust the primary combustion air, turn the screw using a 6 mm. Allen key, as shown in the diagram. Turn it clockwise to increase the airflow, and anticlockwise to decrease it. 0 10 16.7 Combustion line adjustment To adjust the combustion line, loosen the combustion line blocking screw "BL". Turn the line regulator "RL" clockwise to increase the airflow and anticlockwise to decrease it. After adjustment, tighten the combustion line blocking screw "BL". - + RL 1 0 BL 3 mm 16.8 Correct position of electrodes To ensure correct ignition of the Domestic burner, the measurements shown in the diagram must be observed. Also ensure the electrode fixing screws have been screwed in place before replacing the flame tube. 3 mm 2/3 mm 13

Jaka HFD / HFS 16.9 Oil pressure adjustment To adjust the oil pump pressure, turn the screw (1) clockwise to increase the pressure, and anticlockwise to decrease it 1 - Pressure adjustment. SUNTEC - MOD. AS47C DANFOSS - MOD. BFP 21 L3 2 - Vacuum gauge point. 3 - Valve. 4 - Manometer point. 2 1 3 4 5 1 3 4 5 2 5 - Nozzle outlet. 6 - Return. 7 - Intake. 6 7 6 7 16.10 Oil supply piping diagrams The diagrams and tables below correspond to installations without reductions and with a perfect hydraulic seal. It is recommended to use copper pipes. A pressure drop of 0.4 bar (30 cmhg) must not be exceeded. H Intake installation Charging installation H H Intake installation H Pipe length (m) int 8 mm. int 10 mm. 0,0 25 60 0,5 21 50 1,0 18 44 1,5 15 38 2,0 12 26 2,5 10 26 3,0 8 20 3,5 6 16 Charging installation H Pipe length (m) int 8 mm. int 10 mm. 0,5 10 20 1,0 20 40 1,5 40 80 2,0 60 100 14

16.11 Technical specifications MODEL D-3 D-4 Minimum consumption Kg/h 1,5 2,3 Maximum consumption Kg/h 3 4,65 Minimum power kw 17,7 27,2 Maximum power kw 35,5 55,2 Motor power at 2800 r.p.m. W 200 Adjustment type On/Off Electric current 220 V - 50 Hz Weight Kg 12,5 Preheater YES 16.12 Operating curves mmh 2 O OVERPRESSURE / FLOW 15 10 5 D-3 D-4 1 2 3 4 5 Kg/h 10200 20400 30600 40800 51000 Kcal/h 11.8 23.72 35.58 47.44 59.3 Kw GPH 16.13 Fuel flow according to the nozzle and pressure 9 Atm. Kg/h 10 Atm. Kg/h 11 Atm. Kg/h 12 Atm. Kg/h 13 Atm. Kg/h 14 Atm. Kg/h 15 Atm. Kg/h 16 Atm. Kg/h 17 Atm. Kg/h 0,40 1,45 1,55 1,60 1,67 1,75 1,80 1,87 1,94 1,97 0,50 1,80 1,90 2,00 2,10 2,20 2,27 2,33 2,34 2,35 0,55 2,00 2,10 2,20 2,30 2,40 2,50 2,60 2,68 2,71 0,60 2,20 2,30 2,40 2,50 2,60 2,70 2,80 2,90 3,00 0,65 2,35 2,50 2,60 2,70 2,80 2,90 3,05 3,10 3,20 0,75 2,70 2,85 3,00 3,15 3,25 3,40 3,50 3,60 3,70 0,85 3,10 3,25 3,40 3,55 3,70 3,80 4,00 4,10 4,20 1,00 3,60 3,80 4,00 4,20 4,35 4,50 4,70 4,80 4,90 1,10 4,00 4,20 4,40 4,60 4,80 5,00 5,10 5,65 5,75 15

Jaka HFD / HFS 16.14 Electrical connection diagram WITH CONNECTOR Ph F TS TC 1 2 3 4 5 6 7 8 10 11 12 MB EV1 EV2 TR LB FR N WITHOUT CONNECTOR 1 2 3 4 5 6 7 8 10 11 12 MB EV1 EV2 TR LB FR B4 S3 T2 T1 N L1 TC IG TS F LB' N Ph CH B4: Contact of hour-counter. S3: Contact of blocking lamp. TC: Boiler Thermostat. TS: Safety Thermostat. CH: Hour-counter. IG: Main switch F: Fuse. LB: Cut-off Light. LB': External Cut-off Light. FR: Photocell. TR: Transformer. MB: Oil Pump Motor. MB': Auxiliar oil Pump Motor. EV: Valve. Ph: Phase. N: Neutral. 16

16.15 Quick connector To connect and disconnect the red oil intake tube to the nozzle, proceed as follows: - Press the connector ring in the direction of the arrow, pulling on the red tube at the same time. PRESS TUBE OIL RING QUICK CONNECTOR 17

Jaka HFD / HFS 16.16 Burner control operating sequence The burner s LMO control box has a reset button which is the key element for resetting the burner control and activating/deactivating the diagnosis functions. The multi-colour LED on the reset button is the indicator for visual diagnosis. The button and the LED are located under the transparent cover of the reset button. During normal functioning, the various operating statuses are indicated in the form of colour codes (see the colour code table below). During ignition, the indication is as shown in the following table: Reset button Botón de rearme Colour code table for multi-colour indicator lights (LEDs) Status Colour code Colour Wait time «tw», other standby statuses... Off Fuel pre-heater on Yellow Ignition phase, controlled ignition Flashing yellow Functioning, flame OK Green Functioning, flame not OK External light during burner ignition Undervoltage Flashing green Red/green Yellow/red Failure, alarm Red Error code output (see «Error code table») Interface diagnosis Flashing red Flashing red light.. Steady light Red Off Yellow Green 18

17 SPARE PARTS LIST 4 3 5 2 1 7 6 19

Jaka HFD / HFS 12 13 14 15 11 10 9 8 16 17 18 21 20 19 Pos. Code Name 1 SEPO002314 Jaka HFS front panel 2 CFUC000028 Fume inspection cover 3 SEPO002316 Jaka HFS/HFD-30 side panel SEPO002350 Jaka HFS/HFD-40 side panel SEPO002348 Jaka HFS/HFD-50 side panel SEPO002332 Jaka HFS/HFD-60 side panel 4 SEPO002317 Jaka HFS/HFD-30 top cover SEPO002349 Jaka HFS/HFD-40 top cover SEPO002347 Jaka HFS/HFD-50 top cover SEPO002331 Jaka HFS/HFD-60 top cover 5 CEXT000645 Jaka rear panel 6 CFUC000027 Burner support door Pos. Code Name 7 SEPO002315 Base cover 8 CELC000175 Control panel cover 9 CELC000172 Control panel 10 CELC000178 Control unit cover 11 CELC000177 Extension without timer 12 CELC000136 Thermometer 13 CELC000176 Temperature selection knob 14 CELC000007 Control thermostat 15 CELC000034 Anti-inertia thermostat 16 CELC000042 12-pole terminal block 17 CELC000022 Safety thermostat 18 CELC000039 Red pilot light 19 CELC000040 Amber pilot light 20 CELC000138 Main switch 21 CELC000137 Manometer 20

18 BOILER'S WATER PRESSURE DROP DIAGRAMS Within the following diagrams it is possible to calculate the pressure drop of each model of boiler: Jaka HFS / HFD 30 Jaka HFS / HFD 40 Jaka HFS / HFD 50 Jaka HFS / HFD 60 21

Jaka HFD / HFS 19 TROUBLESHOOTING This section provides a list of the most common burner and boiler failures. 19.1 Burner failures We have already mentioned that the burner is equipped with a cut-out system, indicated by a light. It may cut out accidentally, in which case the button light will come on. It can be unblocked by pressing the button. FAILURE CAUSE SOLUTION - Fuel valve closed Open it BURNER DOES NOT IGNITE FREQUENT CUT-OUT 19.2 Boiler failures - No electricity supply to boiler Check it - Nozzle defective or dirty Replace or clean it - Electrodes badly adjusted Adjust them - Timer on automatic Turn it to manual - Room or boiler thermostat badly adjusted Correctly adjust it - Nozzle defective Replace it - Photoelectric cell dirty Clean it - Fume circuit obstructed Clean it - Installation oil filter or burner pump oil filter dirty Clean it FAILURE CAUSE SOLUTION RADIATOR DOES NOT HEAT UP - The pump is not turning Unblock the pump EXCESSIVE NOISE - Air in hydraulic circuit Drain the installation and the boiler (the automatic air drain valve cap must always be loose) - Burner badly adjusted Adjust it correctly - Flue not correctly sealed Eliminate any leaks - Flame unstable Examine the burner - Flue not insulated Suitably insulate it 22

20 GENERAL WARRANTY CONDITIONS DOMUSA TEKNIK guarantees the normal operation of its products in accordance with the following conditions and periods of time, as from the date of their COMMISSIONING. 1 YEAR for electric and hydraulic elements, pumps, valves, etc. 5 YEARS for boiler shells. 5 YEARS for Hot Water Tank. This warranty does not include those failures produced by energy or fuel, failures generated by feeding waters with physical-chemical characteristics such as to produce deposits or corrosion, mishandling of the equipment and, as a general rule, anything beyond DOMUSA TEKNIK s control. The warranty will be considered null and void in the following cases: 1. The boiler han ben installed without meeting the laws and regulations in force regarding the subject matter. 2. The boiler has been commissioned by other personnel than those autorized by DOMUSA TEKNIK. 23

Jaka HFD / HFS NOTES: 24

NOTES: 25

UK ADDRESS HEADQUARTERS & FACTORY Unit D4 Stanlaw Abbey Business Centre, Bº San Esteban s/n Ellesmere Port, CH65 9BF 20737 RÉGIL (Guipúzcoa) Tel: 01519096222 Tel: (+34) 943813899 www.domusateknik.com DOMUSA TEKNIK reserves the right to make modifications of any kind to its product characteristics without prior notice. *CDOC001330* CDOC001330 11/16