Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Similar documents
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra SELV

Centrif Duo & Centrif Duo Plus

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon SELV Tempra

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Silhouette Installation and Wiring Instructions

Lo-Carbon T-series Window & Roof Models

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

HR200WK Through the wall Heat Recovery Ventilator

Installation and Wiring Instructions

SUPER T WALL FANS. Installation and Wiring Instructions

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Lo-Carbon PoziDry Pro

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

DUKA S7. Bathroom fan and Heat mover 8-11 User and Installation instructions. 2 Mounting illustrations 3 Parts. dukaventilation.dk

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent TM Contour Fan

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Installation & Operating Instructions

irconcentre.co.uk airooncentre.co.uk

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Sentinel Kinetic MVHR RANGE

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Xpelair Simply Silent DX100

Instructions for use

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Xpelair Simply Silent DX150

100 FLUEBOOST

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

HOTLINE:

GEH9026G Cooker Hood

GUH90 90 cm Canopy Hood

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

WHHR Midi & Midi Lite

Installation instructions. and User guide. Freestanding canopy NZ AU. HF60CSW2 & HF60CSX2 models

GB User and maintenance manual

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

Installation instructions. and User guide. Slideout rangehood NZ AU. HS60CSRX2, HS60CSRW2, HS90CSX2, HS60CSW2, HS60CSX2, HS60CIW2, HS60CIX2 models

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

INSTALLATION INSTRUCTIONS USER GUIDE

Installation instructions. and User guide. Wall canopy NZ AU. HC60PCIX2 & HC90PCIX2 models

EH0533 Indoor Climate Control

60cm Chimney Extractor

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Installation instructions. Designer series wall canopy. and User guide NZ AU GB IE. HC90DXB1, HC90DMB1 models

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Xpelair Simply Silent DX100B

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

Wiring the fan correctly...

Installation & Operating Instructions

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

ISSY GLIDE VANITY UNIT

FLUEBOOST. flueboost 350 gas fire model

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Warnings, Safety Information and Guidance

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

60cm Integrated Turbo Extractor

aura-t TP536/EU ventilation systems

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Suits all KPF849 models

Xcell 270 Longlife DC wholehouse heat recovery unit

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

EH0554 Indoor Climate Control

Turbo Inline Fan, White - Non Illuminated Art no.33500

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

aura-t TP536/GBR ventilation systems

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Thank you for choosing EnviroVent

Bathroom furniture installation instructions. Contents. Fitting of wall hung brackets 05. Getting started 02. Plumbing recommendations 05

Transcription:

Vent-Axia Svara Multifunctional app controlled fan Important Information 2 Installation and Wiring Instructions 3- Accessories 2 Pin Code 2 6 2 Ø99 Ø77

Important: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION Installation DO NOT install this product in areas where the following may be present or occur: Excessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapours. Ambient temperatures are outside 5-5 C. Possible obstructions which would hinder the access or removal of the Fan. SAFETY AND GUIDANCE NOTES A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm. C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. The fan should only be used in conjunction with fixed wiring. F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time. H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan. I. This appliance is not intended for use by young children or infirm persons without supervision. J. Young children should be supervised to ensure that they do not play with the appliance. K. The exterior grille should be at least 2.3m above the ground to prevent people from being able to access moving parts. If the external grille is positioned between -2.3m from the ground, please use the Vent-Axia wall kit to ensure people cannot access the fans impeller from the outside. Installation Preparation Loosen the motor unit by grasping it as shown in Figure (A), prise off the motor unit by leaveraging against the cap with your knuckles. Ensure that you have the motor unit in a secure grip so you do not drop it when it loosens. Then loosen the wall frame by using a screw driver pressing the lock button as shown in Figure (B) then remove the cover from the wall frame according to figure (C). A. B. C New Installations New installations require holes using a Ø mm hole saw (Figure D). D. Ø mm 5 mm 2 3

Installer information Vent-Axia wall kits and external grilles are available as accessories. (Figure E). Mark the three attachment points for the appropriate screws to the substrate (Figure J). Tighten the screws so that gasket seals against the wall. R75 3 65 E. F. G. R75 95 K. -24 V AC connection The fan s wall seal has a short spigot which fits inside the Ø mm pipe. Make sure when mounting to adapt the length of the wall pipe so it does not push back the wall seal so the fan impeller cannot rotate. Always customise a wall pipe, existing or new, so it ends about 5 mm inside the wall surface where the fan is to be installed. The wall frame with its seal is prepared with 5 cable entry points (Figure F) for concealed electrical connection or surface-mounted cable using the dimension shown in Figure G. Make sure that the gasket is properly installed on the wall frame, place it in the appropriate place and centre it in the pipe. The wall frame can be offset horizontally by placing a spirit level on its support points (Figure H and I). H. I. J. Always use a qualified electrician All electrical connections -24V must be performed by a qualified electrician. Any electrical work on the product must utilise a voltage break. Electrical connection can be made according to the wiring diagram on page 8-9 and the fan is suitable for connection to either -24VAc or 2VDC. NOTE: The internal cable route must be as indicated as figures K/K (24VAC) and L (2VDC) to prevent the cable blocking the locator s for the motor assembly. K. L. 2 V DC connection 4 5

Installer information ELECTRICAL CONNECTION -24VAC NOTE! Wiring of -24VAC must be performed by a qualified electrician. NOTE! The integrated all-pole switch S only functions at -24VAC wiring. Connection of -24VAC and 2VDC can not be done simultaneously (Figure N). N. O. No -24V wiring may penetrate the electronics portion (Figure O.) Svara auto: Continuous trickle speed ventilation, automatic boost at elevated humidity levels, and via the integrated light sensor. ELECTRICAL CONNECTION 2VDC NOTE! 2VDC voltage must not exceed between - 3,6VDC. Svara on/off operation through remote switch: (Can be combined with backdraft shutter) Start / stop via manual switch L. Svara humidity controlled: (Can be combined with backdraft shutter) Trickle setting, automatic start / stop on changes in humidity levels. Svara on/off operation through remote switch, with overrun: (Can be combined with backdraft shutter) Start / stop via manual switch T. Svara auto: 2VDC (switch C always) Continuous trickle ventilation, automatic boost at elevated humidity levels, and via the integrated light sensor. Svara on/off operation through remote switch: (Can be combined with backdraft shutters) 2VDC Start / stop via manual switch C. Svara humidity controlled: (Can be combined with backdraft shutters) 2VDC (switch C always) Trickle setting, automatic start / stop on changes in humidity levels. NOTE! For 2VDC always use switches intended for direct current, C. 6 7

For the user Mounting the cover on the wall frame The fan is double insulated and must not be earthed. When the electrical connection is made place the cover back over the wall frame fitted into the housing hole (Figure P). Vent-Axia Svara Automatic functions and settings via app P. Q. R. Next, fold the cover over the wall frame (Figure Q). Ensure the catch the screwdriver is pointing to (Figure R) engages properly. Make sure that the cover is firmly seated in the hook on the wall frame and latch by pulling a bit of cover. Finally put the motor unit in place (Figure S). Be careful when fitting motor unit, the impellor can be damaged if the unit is forced in at an angle. A distinct click sound confirms that the device is in place, check that the integrated On switch works freely before turning on according to (Figure T). Default setting: Vent-Axia Svara is programmed to cope with the vast majority of installations. The fan works continuously at a trickle flow of l/s. When the fan senses somebody in the room it increases the flow to 6l/s. If the humidity rises rapidly, for example when the shower is on, the fan goes up to maximum flow at 3l/s. When the fan senses the humidity level has returned to normal it reverts to the trickle flow of l/s. If other settings or functions are desired, download the Vent-Axia Connect App from the App Store and Google Play. Technical requirements for Vent-Axia Connect App Apple devices ios 7 or Android OS 4.3 or later with support for Bluetooth 4. Fault indication: Red LED on the fan indicates power failure when the calendar function has been activated. Activate the app: You have to use a code to activate the app, the code is unique for each fan. Enter the code or scan it through your phone. Your unique code is on the back of the user guide and on the right leg of the motor unit (Figure T). T. S. T. Learn more about all the possibilities with our app at www.vent-axia.com/svara 8 9

For the user Servicing and maintenance WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE. Strong solvents should not be used on the fan. The fan must not be dipped in or sprayed with water. For the fan to operate correctly it must be cleaned at least twice a year, more often if necessary. Before cleaning, switch off the power to the fan (Figure U). Loosen the motor unit by grasping it (Figure V), prise off the motor unit by leaveraging the cap with your knuckles. Ensure that you have the motor unit in a secure grip so you do not drop it when it loosens. Clean opening, the duct and the motor unit with a damp cloth (if necessary, use a mild detergent). The impellor does not detach and should be wiped clean in its position on the motor housing If the fan has an external backdraft shutter the shutter should be cleaned gently. Replace the motor unit in the frame. Eco Discarded fans should be submitted as electronic waste to the recycling centre. U. V. The Vent-Axia Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its Lo-Carbon products for five years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product: Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product to your original supplier. The guarantee is offered to you as an extra benefit, and does not affect your legal rights. For the user Safe Water Installation This product conforms to industry regulations for electrical safety. Supplier guarantees the functioning of the relevant regulations and instructions are complied with. All the holes for the screws to be carried out according to the figures X and Y. X. For Wallcoverings Wooden (Figure V), drill only through the coating and waterproofing. NOTE: Never drill through any plywood. Fill the entire hole with age-resistant sealing compound. Use plumbing screws, screw through the plywood into the regulatory framework. Y.

Head Office: Fleming Way, Crawley, West Sussex, RH 9YX. SALES ENQUIRIES: Tel: 844 85659 Fax: 293 56569 TECHNICAL SUPPORT: Tel: 344 856594 Fax: 293 53284 Pin Code for app Important; save this in a secure place. Scan this through the Vent-Axia Connect App or type in the numbers to access the application. The same pincode can also be found on the right leg of the motor unit. Accessories (purchased separately). Backdraught shutter Svara 4989 2. Cover plate white 4982, for duct dimensions between Ø4-6. 2. Copyright Vent-Axia We accept no liability for printing errors and reserve the right to make changes to materials and designs. 4982