ASHRAE 90.1 COMPLIANT 6 to 36 Tons

Similar documents
LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

COMFORT IN THE CLASSROOM

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Lennox Mini-Split Systems Year-Round Comfort and Performance

The ultimate fresh air solution.

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

Increase your flexibility.

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

L CONNECTION NETWORK Commercial Controls

2 shp 13 lc 1 36 t - 1 a

DC Inverter Smart VRF Products(R410A)

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and Reliability. CB*, C* and TA* Models

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

LG VRF Systems. Air Conditioning Technologies

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

YMGI HVAC Line Card VRF Outdoor Units

MERIT Series R-410A - Upflow / Horizontal

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

YDS Variable Refrigerant Flow System. Digital Scroll Technology 3rd Generation

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

MISCELLANEOUS ENGINEERING DATA EXPANSION VALVE CROSS-REFERENCE DATA PRODUCT SPECIFICATIONS

Variable Refrigerant Flow (VRF) Systems

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

3 rd Generation of VRV. The professional solution for your professional project

DAIKIN Air Handling Unit Modular

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

Residential and Light Commercial Ductless Systems Catalog

MERIT Series R-410A - Upflow / Horizontal

Variable Refrigeration Flow Systems Overview 10/11/2016

13 GEP A L P - 1 A

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Product Line Introduction. Karl Zhang Technical support engineer

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

MERIT SERIES Downflow

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

RGE 13 A T - 1 A

HEALTHY CLIMATE PureAir Air Purification System

SECTION VARIABLE REFRIGERANT FLOW SYSTEM

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Heat Pump Air Conditioning Systems

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

T S A 048 S 4 N 4 1 T

Energy Efficiency Demonstration Residential Ductless Heat Pumps (DHP) Overview. Ammi Amarnath Chris Trueblood

Inventor of the Inverter

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

Variable Refrigerant Flow (VRF) Multi-Zone Systems

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS PRODUCT PORTFOLIO

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

ELITE SERIES Downflow - High Efficiency Blower Motor

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Superior Technology and Integration VARIABLE REFRIGERANT FLOW SYSTEMS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

2008 Midea Commercial A/C

... Air Conditioners & Heat Pumps Light Commercial ...

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

Control System Structure

Energy Recovery Ventilators

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

VRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular

AFUE 95% Heating Input 50,000 to 200,000 Btuh

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Ductless Series Variable Speed Split Systems

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

VENTILATION. Effective heat exchange and fresh air ventilation

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

All DC Inverter Multi VRF

Product Launch SHRMi

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

MERIT SERIES Up Flow / Horizontal

Engineering Data Book

Engineered for flexibility and performance

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

True performance and rugged durability. TU, LF and LD Models

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Transcription:

PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF Commercial Modular Heating/Cooling System - 60HZ Bulletin No. 10678 November 016 Supersedes June 015 SYSTEM OVERVIEW The VRF commercial modular heating/cooling system consists of single or multiple variable-capacity outdoor units (Heat Recovery Units or Heat Pumps) connected to multiple indoor units in one system. Varible-capacity outdoor units modulate the amount of refrigerant needed based on cooling and heating demands allowing for reduced energy usage at partialload conditions. Heat Recovery units allow individual indoor units in the system to simultaneously heat and cool at the same time, while the compressor load benefits from the internal heat recovery. Heat Pump units allow for operation in heating or cooling mode. All indoor units will operate in the same mode at the same time. The VRF system provides a broad range of different applications for settings such as highrise buildings, offices, hotels and schools. Small size and individual components make the VRF system ideal for retrofit in older buildings where room for ductwork is limited. Customized heating/cooling capacities with flexible indoor unit combinations for each room size and shape. A wide range of indoor unit styles are available to suit any application. CONTENTS Basic System Overview... Branch Box... 8 Branch Pipes... 9 Centralized Controls... 8 Controls... 7 Indoor Units... 6 Miscellaneous... 8 Mode Selection Boxes... 8 Monitoring... 8 Outdoor Units... 5 System Combinations... 4 The space-saving VFR system uses less space than a conventional ducted rooftop unit. Minimum installation footprint reduces the floor load and can eliminate the need for mechanical rooms in many applications. The small size of the units make them easy to transport to the jobsite. Longer total piping lengths (up to 300 ft. length and 360 ft. drop) for large building applications. High efficiency oil balance and return technology assures proper compressor operation throughout the system. Easy installation and total system control. A wide variety of control options are available for any type of application. Centralized monitoring of the entire system allows control from a single location, Communication wiring is shared by both indoor and outdoor units for an easier installation. NOTE - See individual Product Specifications bulletins for Outdoor Units, Indoor Units, Controls, Mode Selection Boxes and Branch Pipes for additional information about specifications, ratings, dimensions and other data. APPROVALS ASHRAE 90.1 COMPLIANT 6 to 36 Tons AHRI Certified to AHRI Standard 130-010 (6 to 36 ton systems) and AHRI 10/40-008 (3 to 5 ton heat pump systems). Units are ETL certified for the U.S. and Canada.

BASIC SYSTEM OVERVIEW TYPICAL SYSTEM LAYOUT (Heat Recovery System Shown) VRA Heat Recovery Outdoor Units Mode Selection Boxes Branch Pipes Indoor Units VRF Systems / Page

BASIC SYSTEM OVERVIEW (CONTINUED) VRA HEAT RECOVERY SYSTEM (Simultaneous Heating and Cooling) VRF Heat Recovery Outdoor Unit NOTE - See Product Specifications for individual components for additional details. Mode Selection Box Cooling Cooling Heating Heating Max. 4 Indoor Units Max. 4 Indoor Units Mode Selection Box Cooling Cooling Heating Heating Cooling Max. 4 Indoor Units Mode Selection Box Heating Cooling Cooling Heating Heating Heating Cooling Cooling Max. 4 Indoor Units Max. 4 Indoor Units VRF Systems / Page 3

SYSTEM COMBINATIONS HEAT RECOVERY MODELS Model No. Capacity Outdoor Unit Combinations VRF Systems / Page 4 Maximum Number of Indoor Units VRA07H4 6 Ton (1) VRA07H4 13 VRA096H4 8 Ton (1) VRA096H4 16 VRA10H4 10 Ton (1) VRA10H4 0 VRA144H4 1 Ton (1) VRA144H4 6 VRA145H4 1 Ton (1) VRA07H4 + (1) VRA07H4 6 VRA168H4 14 Ton (1) VRA096H4 + (1) VRA07H4 9 VRA19H4 16 Ton (1) VRA096H4 + (1) VRA096H4 33 VRA16H4 18 Ton (1) VRA10H4 + (1) VRA096H4 36 VRA40H4 0 Ton (1) VRA10H4 + (1) VRA10H4 39 VRA64H4 Ton (1) VRA10H4 + (1) VRA144H4 46 VRA65H4 Ton (1) VRA096H4 + (1) VRA096H4 + (1) VRA07H4 46 VRA88H4 4 Ton (1) VRA144H4 + (1) VRA144H4 50 VRA89H4 4 Ton (1) VRA10H4 + (1) VRA096H4 + (1) VRA07H4 50 VRA31H4 6 Ton (1) VRA10H4 + (1) VRA096H4 + (1) VRA096H4 53 VRA336H4 8 Ton (1) VRA096H4 + (1) VRA10H4 + (1) VRA10H4 56 VRA360H4 30 Ton (1) VRA10H4 + (1) VRA10H4 + (1) VRA10H4 60 VRA384H4 3 Ton (1) VRA10H4 + (1) VRA10H4 + (1) VRA144H4 63 VRA408H4 34 Ton (1) VRA144H4 + (1) VRA144H4 + (1) VRA10H4 63 VRA43H4 36 Ton (1) VRA144H4 + (1) VRA144H4 + (1) VRA144H4 63 HEAT PUMP MODELS Model No. Capacity Outdoor Unit Combinations Maximum Number of Indoor Units VPA07H4 6 Ton (1) VPA07H4 13 VPA096H4 8 Ton (1) VPA096H4 16 VPA10H4 10 Ton (1) VPA10H4 0 VPA144H4 1 Ton (1) VPA144H4 6 VPA145H4 1 Ton (1) VPA07H4 + (1) VPA07H4 6 VPA168H4 14 Ton (1) VPA096H4 + (1) VPA07H4 9 VPA19H4 16 Ton (1) VPA096H4 + (1) VPA096H4 33 VPA16H4 18 Ton (1) VPA10H4 + (1) VPA096H4 36 VPA40H4 0 Ton (1) VPA10H4 + (1) VPA10H4 39 VPA64H4 Ton (1) VPA10H4 + (1) VPA144H4 46 VPA65H4 Ton (1) VPA096H4 + (1) VPA096H4 + (1) VPA07H4 46 VPA88H4 4 Ton (1) VPA144H4 + (1) VPA144H4 50 VPA89H4 4 Ton (1) VPA10H4 + (1) VPA096H4 + (1) VPA07H4 50 VPA31H4 6 Ton (1) VPA10H4 + (1) VPA096H4 + (1) VPA096H4 53 VPA336H4 8 Ton (1) VPA096H4 + (1) VPA10H4 + (1) VPA10H4 56 VPA360H4 30 Ton (1) VPA10H4 + (1) VPA10H4 + (1) VPA10H4 60 VPA384H4 3 Ton (1) VPA10H4 + (1) VPA10H4 + (1) VPA144H4 63 VPA408H4 34 Ton (1) VPA144H4 + (1) VPA144H4 + (1) VPA10H4 63 VPA43H4 36 Ton (1) VPA144H4 + (1) VPA144H4 + (1) VPA144H4 63

OUTDOOR UNITS VRA Heat Recovery Outdoor Unit VPA Heat Pump Outdoor Unit VPA Mini Heat Pump Outdoor Unit Capacity (Tons) 3 4 5 6 8 10 1 14 16 18 0 4 6 8 30 3 34 36 VRF Systems / Page 5

INDOOR UNITS Capacity (kbtuh) Compact 360 Cassette 360 Cassette Concealed Medium Static Ducted Concealed High Static Ducted VA V33A VMDA VHIA 007 009 01 015 018 04 030 036 048 054 07 096 Capacity (kbtuh) Wall-Mount Non-Ducted Ceiling/Floor Mount Non-Ducted Dedicated Outdoor Air Concealed Ducted (Heat Pump Systems Only) Upflow Air Handler VWMA VCFA VOSA VVCA 007 009 01 015 018 04 030 036 048 054 07 VRF Systems / Page 6

CONTROLS Wireless Remote Control Non-Programmable Wired Controller Programmable Wired Controller Indoor Unit Central Controller Features V0STAT5P V0STAT54P V0STAT51P V0CTRL75P Maximum Controllable Indoor Units 1 Multiple 1 1 64 Backlight Current Time - - - - - - System On/Off System On/Off Timer - - - System Mode Setting Fan Speed Setting Room Temperature Setting Horizontal Swing - - - Vertical Swing - - - - - - - - - Air Direction - - - - - - - - - Economy Mode - - - - - - - - - Group Setting - - - - - - - - - Controller Lock - - - Mode Lock - - - - - - - - - Address Setting - - - - - - - - - Address Display - - - - - - - - - Error Code Display - - - - - - Emergency Stop/Start - - - - - - - - - Building Management Access - - - - - - - - - Control via Internet - - - - - - - - - Air Filter Reminder - - - - - - 78 F Shortcut Setting - - - - - - - - - 50 F Heat Setting - - - - - - - - - 1 One wireless remote control can individually control multiple indoor units in different areas (room to room). Available if indoor unit is equipped with this feature. VRF Systems / Page 7

CENTRALIZED CONTROLS BACnet Gateway LonWorks Gateway 15-Inch LVM Touch Panel Centralized Control System 1-Inch LVM Touch Panel Centralized Control System V0CTRL86P V0CTRL87P LVM Touch Panel V0CTRL15P LVM Hardware V0CTRL85P LVM Software V0CTRL91P LVM Touch Panel V0CTRL1P LVM Hardware V0CTRL85P LVM Software V0CTRL91P MISCELLANEOUS MONITORING Key Card Interface Module Infrared Sensor Non-Programmable ERV Controller Outdoor Unit Central Monitor V0CTRL88P V0SNSR78P V0STAT53P V0CTRL80P MODE SELECTION BOXES NOTE - For VRA Heat Recovery Units Only 1 group, 1 indoor unit maximum groups of 4, 8 indoor units maximum 4 groups of 4, 16 indoor units maximum 6 groups of 4, 4 indoor units maximum V8MSBB01 V8MSBB0 V8MSBB03 V8MSBB04 BRANCH BOX NOTE - For Mini Heat Pumps only Up to 9 indoor units with three branch boxes V8MIDB01 VRF Systems / Page 8

BRANCH PIPES Outdoor Branch Pipe For connecting multiple outdoor units VRA Heat Recovery (HR) and VPA Heat Pump (HP) to the main branch piping Mode Selection Box Branch Pipe For connecting the main refrigerant piping to the Mode Selection Box for VRA Heat Recovery Units only. Indoor Branch Pipe For connecting the Mode Selection Box to the indoor units (VRA Heat Recovery Units) or connecting outdoor unit pipe and indoor units (VPA Heat Pumps). V8ODBP0HR V8MSBP01 V8IDBP01 V8ODBP03HR V8MSBP0 V8IDBP0 V8ODBP0HP V8MSBP03 V8IDBP03 V8ODBP03HP V8MSBP04 V8IDBP04 - - - V8MSBP05 V8IDBP05 NOTE - See Branch Pipe / Piping Selection Product Specifications for usage, dimensions and details.

REVISIONS Sections Controls Indoor Units Outdoor Units Description of Change Added new V0STAT51P and V0STAT54P Wired Controllers. Removed Energy Recovery Ventilator VRVA. Added 5 ton Mini Heap Pump Variable Refrigerant Flow (VRF) Multi-Split AC and HP AHRI Standard 130 Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 016 Lennox Industries, Inc.