Chimney Pots & Gas Flue Terminals

Similar documents
Clayware, Chimney & Roofing

Studio 3 Steel 2, Glass Fronted with Log-effect fuel bed and Vermiculite lining STUDIO GAS FIRES

Please note: Not all frames, finishes, linings or fuel effects illustrated throughout this brochure may be available as a stock item.

RESTORATION SPECIALISTS

Product Catalogue 10YEAR. Fitzroy Profile and Canterbury Classic Series 2015 WAR RAN T Y YEAR

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

INSTALLATION INSTRUCTIONS GB/IE

Stoves & Inserts. Gas. continentalfireplaces.com

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Put a heart in your home...

window shopping with a difference!

CHIMNEYS AND VENTS CHAPTER 8

Rytons Boiler, Stove & Fire Ventilators

Edition 5 HARDWORKING HEATING COLLECTION. Putting warmth at the heart of the home

GLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY

Commissioning of Heat Producing Appliances Burning Solid Fuel

Uniclass L442 CI/SfB (34) X. Architectural Handrail and Balustrade. Architectural metalwork systems

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Twin Wall Installation Instructions And Maintenance Guide

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler

TRENT FIREPLACES FIRES

Gas Stoves & Inserts. Innovative Heating Solutions continentalfireplaces.com

Endura-Stone Column Specifications

BDM Direct Vent systems are for use with direct vent gas fired appliances.

Technical Guidance CE Marking of Metal Chimneys and Flues

HARMONY Direct Vent Gas Inserts

Cleaner & More Efficient Heating Than Ever Before

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

Kaliko hearth mounted. Kaliko HIW

Direct Vent Gas Inserts HARMONY. In perfect tune with your style.

The Lifestyle Collection. The stylish, versatile way to enhance your living space

WOOD BURNING FIREPLACES napoleonfireplaces.com

EN transition from BS 1387 Structural & Conveyance Business

PLASTER TRIMLESS FLUSH LUMINAIRES

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

DECORATIVE ELEMENTS OPTIONS. Add a little flare to your glass structure.

Riva Studio Dedicated Sealed External Air Kit

napoleonfireplaces.com WOOD BURNING WOOD BURNING FIREPLACES

Triumph Direct Vent Gas Inserts STYLE. COME TO LIGHT.

Permanent Ventilators (for the Supply of Combustion Air)

The Boru 400i. The Boru 600i. 400i with 4 sided curved frame. Boru 600i with 4 Sided Frame

Our high quality, built-in extraction systems allow you to design the perfect kitchen without compromise

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

The Lifestyle Collection. Bi-fold, French and patio doors

FIELD DRAFT CONTROLS

THE SEVERN. Installation Instructions for Freestanding Severn Stove with Boiler PERFORMANCE RATING

SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS

Installation Instructions. Rayburn 300W Wood Burning Cooker

P P Gas Fireplace. P See Thru

100% IRISH...make yours a Brightfire.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

FLiX. Fast fit twin wall flexible flue liner. Quality twin wall flexible flue liner designed for gas, oil and multi-fuel

ACCESSORIES ARCHITECTURAL IRONMONGERS SECURITY SPECIALISTS

TRUST ONLY GENUINE COONARA WOODHEATERS

Introduction. General. Other regulations. British Standards and European Technical Specifications

Rytons Boiler, Stove & Fire Ventilators

Please note: Not all frames, finishes, linings or fuel effects illustrated throughout this brochure may be available as a stock item.

SIZING HANDBOOK & APPLICATION GUIDE

RS Chimney Fan for Solid Fuel Applications

Classic Fireplaces Fire Baskets

Sydney Doors. ultimate door collection. save time and money

Cassette inserts and fireplace doors

CHAPTER 8 CHIMNEYS AND VENTS

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

Single-Control Lavatory Faucet

TRUST ONLY GENUINE COONARA WOODHEATERS

Logic GAS FIRES. Classic Fireplaces Fire Baskets

TIMELESS NORWEGIAN CRAFT

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

I2400 I3100 CLASSIC WOOD INSERTS ZONE HEAT FOR LOWER HEATING BILLS - I2400 A SIZE PERFECT FOR ANY ROOM - I3100 SPECIFICATIONS I2400 I3100

Inspiration vertical sliding sash windows. Beautiful traditional sash windows with the advantages of modern day technology

PELLET STOVES & INSERTS. PELLET STOVES & INSERTS

Architectural Plastering

MODEL CF CEILING SUPPORTED CHIMNEY

Installation Instructions

HIGH EFFICIENCY GLASS FRONTED GAS FIRES

Bringing home the warmth of wood heating Collection

Breathe new life into your landscape.

With its strong horizontal lines contemporary burner, a Boulevard Linear Direct- Vent Fireplace adds drama to your décor.

gas log fires freestanding & inbuilts

TIMELESS NORWEGIAN CRAFT GAS PRODUCTS

2012 INTERNATIONAL FUEL GAS CODE VENTS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Elegance, warmth and efficiency come together in these versatile gas fireplace inserts available with a variety of faces to suit any style.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

The Ravelle direct-vent gas fireplaces balance elegant design, premium-quality construction, and two heating capacities for unmatched flexibility.

RAVELLE DIRECT-VENT GAS FIREPLACES

Decorative Ceiling Spot Lights

Multi Fuel Heating Solutions for Every Home. A Cast Iron Masterpiece

NEW. Fifty Years of Progress

ENERVEX RSV CHIMNEY FAN

NARI COTY 2017 AWARDS. Residential Historical Renovation/Restoration Under $250,000

flue&ducting Flue and Chimney Supplies NEXTDAY SAMEDAY DELIVERY DELIVERY


GAS INSERTS BY REDISCOVER FIRE

FIRES & SUITES

CONTEMPORARY GAS FIREPLACES. CONTEMPORARY GAS FIREPLACES. woo

Transcription:

Uniclass L73323:P332 CI/SfB (28.89) Yg2 November 2002 Chimney Pots & Gas Flue Terminals BUILDING MASTERPIECES Total Chimney Solutions

on top The latest range of chimney products from Red Bank has been developed to harmonise with nature s changing environments. The range offers texture, colour and performance allowing architects and builders to create masterpieces that withstand the test of time. of the world 2

Index List Description Page No. 1 Roll Top 5 2 Plain Tapered 5 3 Plain Beehive 25 4 Cannon Head - Traditional 5 5 Louvre Insert 11 6 Bishop 16 7 Square Panelled Pot 10 8 Fluted Round 22 9 Rectangular Base Octagon Pot 9 10 Champion 16 11 Louvre 11 12 Capped Louvre 11 13 Capped Louvre Insert 11 14 Pocket Beehive 25 15 Two Roll 22 16 Square Plain Pot 10 17 Lancashire Bishop 16 18 Lady Broughton 25 20 Four Pocket Roll 24 22 Three Roll 22 24 Roll Taper 5 26 Three Rib Roll 23 27 Square Spiked Pot 10 29 Cowl Top 28 30 Hood Top 28 31 Barrel Top 15 33 Beaded Flue 6 34 Capped Cannon Head 21 35 Tapered Louvre 21 36 Octagon Louvre Pot 9 38 Cannon Head Louvre 21 39 Plain Octagon Pot 9 42 Crown 21 43 Rook 22 44 Gypsy Louvre 22 45 Fluted Pedestal 21 46 Ornamental Louvre 22 47 Three Groove Roll 23 48 Three Ring Louvre Top 12 49 Four Ring Louvre Top 12 50 Five Ring Louvre Top 12 50A Six Ring Louvre Top 12 51 Sheffield Louvre Base 12 52 Dublin Can 25 53 Square Base Octagon Pot 9 53 Square Base Octagon Pot 9 with Fixed Hood 56 Four Ring Roll 23 List Description Page No. 57 Castle 22 58 Venetian 15 59 Georgian 16 60 Marcone Flanged Base 15 60 Marcone Plain Base 15 62 Roll Base 5 63 Common Beaded Pot 6 64 Beaded Base Pot 6 65 Jamieson 25 66 Square Pot 10 67 Square Pot 10 69 Square Taper Pot 10 71 Crown Louvre Top 13 72 Crown Louvre Top 13 73 Louvre Top 13 74 Hooded Louvre Top 13 75 Louvre Base 13 76 Weemac 24 78 Beaded Cannon Head 23 79 Octagon Pot 9 80 Octagon Pot 9 81 Octagon Pot 9 82 Ornamental Round 23 83 London Roll 23 87 Flush Beaded Flue 6 88 Hooded Square with Pockets 10 90 Moulded Taper 23 91 Irish Roll 24 92 Rectangular Taper 24 93 Moulded Taper 24 94 Hooded Pot 24 97 H Pot 17 98 H Insert 17 100 Plain Can 18 101 Horned Can 18 102 Plain Cap 19 103 Hood Top (Square Spigot) 28 104 Horned Cap 18 106 Three Ring Louvre Top 13 107 Four Ring Louvre Top 13 108 Five Ring Louvre Top 13 109 Six Ring Louvre Top 13 110 Ornamental Base 13 111 Marcone Cap 15 112 Venetian Cap 15 113 Capped Can 25 114 Contemporary Cannon 5 Head Pot List Description Page No. 115 Three Horned Roll Pot 18 116 Weatherguard Top 29 117 Blank Stopper 29 118 Mushroom Top 29 119 Mushroom Top 29 (Outside Fitting) 120 Flue Ventilator 29 121 Beaded Rebated 8 122 H Pot (150mm Tube) 17 123 H Pot with Lid 17 126 Square Base Octagon Pot 9 127 Round Based Bishop 16 128 Beaded Rebated 8 129 Beaded Rebated 8 129 Beaded 8 134 Contemporary Cannon Head Pot 5 145 DFE Pots 33 146 DFE Insert 33 146 DFE Square Insert 33 175 BSS Type 4D 7 176 BSS Type 5E 7 177 BSS Type 5E 7 178 BSS Type 6F 7 179 BSS Type 6F 7 180 BSS Type 6F 7 181 BSS Type 6F 7 182 BSS Type 6F 7 183 BSS Type 6F 7 534 GC9 32 610 GC2 Base 31 611 GC2 Top 31 612 GC2 Insert 31 613 GC3 Insert 31 617 GC2 Insert Square 31 618 Bishop GC2 32 623 Stangas 32 624 Crowned GC5 32 625 GC5 32 628 Double Beaded Can 19 629 LM1, LM2, LM3, LM4, LM5 19 634 Captain Pot 26 636 GC10 Clay Can and Plate 31 Contents 4-8 Round Tapered & Beaded 9-10 Octagons & Squares 11-13 Louvres 14-16 Traditional 17-19 H -Type & Scottish 20-27 Ornamental & Special Patterns 28-29 Inserts 30-33 Gas Flue Terminals 34-35 Suitability and Application Notes Products available in red, buff and slate bodymix. All dimensions are in mm, drawings not to scale and all sizes nominal. The colours in this brochure are as true as can be obtained by the normal printing process. Red Bank Manufacturing is committed to a program of continuous product development and reserve the right to alter specifications without prior notification. 3

Chimney Pots Gracefully rising up into the sky Red Bank s range of Chimney Pots offers style and elegance for the perfect finishing touch to any chimney. 4

Round Tapered Round Tapered 134 62 1 4 24 114 2 Round Tapered No. A B C D 1 Roll Top 150, 225, 300, 375, 450, 600, 750, 900, 1050 250 280 200 265 1200, 1500, 1800 265 300 220 300 2 Plain Tapered 300 250 280 200 240 4 Cannon Head - 300, 375, 450, 600, 750, 900, 1050 250 280 200 280 Traditional 1200, 1500, 1800 265 300 225 320 24 Roll Taper 300, 375, 450 265 300 200 260 62 Roll Base 300, 375, 450, 600, 750, 900, 1050 250 280 200 260 1200, 1500, 1800 250 290 225 290 114 Contemporary 300, 375, 450, 600, 750, 900, 1050 250 280 200 265 Cannon Head Pot 1200, 1500, 1800 250 300 200 265 134 Contemporary 300, 450, 600 360 400 300 370 Cannon Head Pot 5

Beaded Flue Terminals 63 87 33 64 Beaded Flue Terminals No. A B C D 33 Beaded Flue 300, 450, 600 225 270 225 285 300, 450, 600 300 350 300 385 63 Common 450, 600 215 260 215 275 Beaded Pot 64 Beaded Base Pot 450, 600 225 265 210 275 87 Flush Beaded 300 210 260 210 260 Flue 6

Beaded Flue Terminals 178 176 180 179 177 175 181 183 182 Square to Round Round to Taper Round Parallel Beaded Flue Terminals No. A B C D * 175 BSS Type 4D 300, 450, 600, 750, 900 185 sq 230 150 dia 200 175 BSS Type 4D 300, 450, 600, 750, 900 200 sq 245 200 dia 265 175 BSS Type 4D 300, 450, 600, 750, 900 225 sq 265 200 dia 265 175 BSS Type 4D 300, 450, 600, 750, 900 250 sq 300 250 dia 310 175 BSS Type 4D 300, 450, 600 300 sq 355 300 dia 385 * 176 177 BSS Type 5E BSS Type 5E 300, 375, 450, 600, 750, 900 300, 375, 450, 600, 750, 900 185 dia 250 dia 285 295 150 dia 210 dia 200 265 * 178 BSS Type 6F 300, 375, 450, 600, 750, 900 150 dia 175 150 dia 210 179 BSS Type 6F 300, 375, 450, 600, 750, 900 200 dia 245 200 dia 270 180 BSS Type 6F 300, 375, 450, 600, 750, 900 225 dia 270 225 dia 285 181 BSS Type 6F 300, 375, 450, 600, 750, 900 250 dia 295 250 dia 310 182 BSS Type 6F 300, 375, 450, 600, 750, 900 300 dia 360 300 dia 385 183 BSS Type 6F 300, 375, 450, 600, 750, 900 350 dia 400 350 dia 430 *see notes on pages 34 and 35 regarding limited application. 7

Beaded Flue Terminals 121 129 128 Beaded Flue Terminals No. A B C D Please Note: Beaded Rebated terminals to suit clay flue linings * 121-185 Beaded Rebated 300, 450 185 dia 230 185 dia 265 121-200 Beaded Rebated 300, 450 200 dia 245 200 dia 270 128-225 Beaded Rebated 300, 450 225 dia 270 225 dia 290 129-185 Beaded Rebated 300, 450 185 sq 235 185 sq 250 129-200 Beaded Rebated 300, 450 200 sq 245 200 sq 270 129-225 Beaded Rebated 300, 450 225 sq 275 225 sq 295 129-250 Beaded Rebated 300, 450 250 sq 310 250 sq 330 129-300 Beaded Rebated 300, 450 300 sq 370 300 sq 425 129-200 Beaded 300, 450 200 sq 245 200 sq 270 129-250 Beaded 300, 450 250 sq 310 250 sq 330 129-300 Beaded 300, 450 300 sq 370 300 sq 425 8 *see notes on pages 34 and 35 regarding limited application.

Beaded Flue Terminals & Octagons Octagons 39 9 80 53 Square Base Octagon Pot without fixed hood 36 81 126 79 Octagons No. A B C D * 36 Octagon Louvre Pot 600, 750, 900 275 dia 320 175 dia 250 * 39 Plain Octagon Pot 600, 900 265 dia 315 150 dia 290 79 Octagon Pot 525, 750 250 dia 300 200 dia 285 80 Octagon Pot 600, 750, 900 290 dia 340 240 dia 350 1200, 1500, 1800 81 Octagon Pot 600, 750, 900 250 dia 300 200 dia 300 1050 365 dia 425 300 dia 415 9 Rectangular Base Octagon Pot 400 290x190 350x225 200 dia 275 53 Square Base Octagon Pot 375, 450 265 sq 310 sq 200 dia 275 * 53 Square Base Octagon Pot 550 265 sq 310 sq 200 dia 275 complete with Fixed Hood 126 Square Base Octagon Pot 450 265 sq 310 sq 200 dia 275 *see notes on pages 34 and 35 regarding limited application. 9

Squares 27 67 7 69 88 16 66 'G' Squares No. A B C D E F G 7 Square Panelled Pot 550 265 315 200 300 16 Square Plain Pot 450, 600, 750 265 315 200 300 27 Square Spiked Pot 650, 750 250 300 200 285 100 66 Square Pot 525 250 315 240 315 140 67 Square Pot 450 225 275 225 300 140 * 69 Square Taper Pot 300 240 290 160 200 88 Hooded Square 850 250 315 140 430 90 225 210 with Pockets 875 300 370 140 350 100 300 250 10 *see notes on pages 34 and 35 regarding limited application.

Squares & Louvres Louvres 5 12 13 11 65 65 65 65 'G' 'G' Louvres No. A B C D E F G * 5 Louvre Insert 450 100 135 200 295 75 90 110 125 170 145 190 170 205 11 Louvre 450, 600, 750 240 290 200 295 75 90 900, 1050, 1200 1500, 1800 * 12 Capped Louvre 525 600 750 900 260 290 300 110 90 * 13 Capped Louvre Insert 525 100 135 300 110 90 110 125 170 145 190 170 205 *see notes on pages 34 and 35 regarding limited application. 11

Louvre Tops & Bases 49 50 51 48 50A Louvre Tops & Bases No. A B C D E F 48 Three Ring Louvre Top 370 275 320 200 75 75 49 Four Ring Louvre Top 440 275 320 200 75 75 50 Five Ring Louvre Top 510 275 320 200 75 75 50A Six Ring Louvre Top 575 275 320 200 75 75 51 Sheffield Louvre Base 300, 375, 450 215 260 200 245 50 320 600, 750, 900 12

Louvres Louvre Tops & Bases 109 108 74 107 106 73 72 110 195 165 250 225 260 225 315 275 75 75 25 85 65 75 325 370 270 310 275 320 225 290 71 75 Louvre Tops & Bases No. A B C D E F 71 Crown Louvre Top 525 265 300 200 265 365 225 72 Crown Louvre Top 375 290 320 225 325 380 75 73 Louvre Top 300 265 300 260 365 * 74 Hooded Louvre Top 415 265 300 285 365 115 75 Louvre Base 750 250 295 215 250 310 45 * 106 Three Ring Louvre Top 375 see illustrated detail * 107 Four Ring Louvre Top 450 see illustrated detail * 108 Five Ring Louvre Top 525 see illustrated detail * 109 Six Ring Louvre Top 600 see illustrated detail 110 Ornamental Base 450 see illustrated detail *see notes on pages 34 and 35 regarding limited application. 13

Traditional Reaching new heights in quality with Red Bank s Traditional Range of Chimney Pots. Carefully crafted to blend with chimneys of age and beauty. 14

Traditional Traditional 112 31 58 600 Single Flute Only 60 111 Please Note: Many Traditional and Ornamental patterns are still manufactured to age old designs and may not meet current regulations. If in doubt see notes on pages 34 and 35 regarding limited application or contact Red Bank Traditional No. A B C D E F 31 Barrel Top 600, 750 250 290 375 200 * 58 Venetian 600, 750, 900, 1050 240 285 150 185 * 60 Marcone Flanged Base 600, 990, 1220 240 275 175 220 325 * 60 Marcone Plain Base 600, 990, 1220 200 240 175 220 325 111 Marcone Cap 240 290 320 200 240 * 112 Venetian Cap 210 150 195 175 220 220 85 *see notes on pages 34 and 35 regarding limited application. 15

Traditional cont. 17 6 10 59 127 240 295 260 160 200 410 75 65 490 165 135 1200 100 290sq 340sq 175 235 295 365 Traditional No. A B C D E F 6 Bishop 600, 750 see illustrated detail 900, 1050 * 10 Champion see illustrated detail 17 Lancashire Bishop 600, 750 290 340 260 295 * 59 Georgian 600 260 310 200 250 340 310 127 Round Based Bishop 600 285 315 200 260 295 750 290 325 225 290 335 900 330 360 250 330 390 1050 390 430 300 390 450 16 *see notes on pages 34 and 35 regarding limited application.

Traditional & H-Type H-Type 123 97 98 122 125 H Type No. A B C D E F 97 H Pot 600, 750, 900 260 290 200 240 375 750 1050, 1200 * 98 H Insert 425 190 240 175 225 325 775 * 98 H Insert 425 205 275 175 225 325 775 * 122 H Pot (150mm Tube) 600 235 265 150 190 300 600 123 H Pot with Lid 600, 750, 900 260 290 200 240 375 750 *see notes on pages 34 and 35 regarding limited application. 17

Scottish 101 115 100 104 Scottish No. A B C D 18 100 Plain Can 450, 600, 750 250 290 215 265 900, 1050 101 Horned Can 450, 600, 750 260 290 215 265 900, 1050, 1200 104 Horned Cap 265 300 350 210 270 115 Three Horned Roll Pot 450, 600, 750, 900 260 290 200 260

Scottish 628 102 629 628 629 629 LM1 LM2 629 LM3 629 LM4 629 LM5 Scottish No. A B C D E 102 Plain Cap 265 250 300 210 270 628 Double Beaded Can 600, 750, 900 225 260 225 275 180 629 Edinburgh LM1 600, 750, 900, 1200 250 300 250 320 180 629 Edinburgh LM2 600, 750, 900 250 300 250 320 75 629 Edinburgh LM3 600, 750, 900 250 300 250 320 260 629 Edinburgh LM4 750, 900 250 300 250 320 190 629 Edinburgh LM5 600, 750, 900 250 300 250 320 180 19

Ornamental & Specials The Red Bank Ornamental range of chimney pots offers top solutions to make any skyline look special. Using traditional build methods to harmonise with most desired applications. 20

Ornamental Ornamental 45 38 34 35 42 Ornamental No. A B C D E F * 34 Capped Cannon Head 900 250 285 150 185 285 200 35 Tapered Louvre 600 265 300 200 240 315 175 38 Cannon Head Louvre 900 260 290 210 240 335 165 42 Crown 450, 600, 900 250 290 200 240 90 45 Fluted Pedestal 600 265 315 215 290 *see notes on pages 34 and 35 regarding limited application. 21

Ornamental cont. 46 8 22 44 43 57 15 250 215 270 125 125 50 250 195 265 180 240 215 240 265 275 300 Ornamental No. A B C D E 8 Fluted Round 600 275 315 245 315 15 Two Roll 300, 375, 450, 600 265 300 200 260 750, 900 22 Three Roll 300, 375, 450, 600 265 300 200 260 750, 900 43 Rook 380 250 290 200 240 61 500 260 290 200 240 45 * 44 Gypsy Louvre 600 see illustrated detail 46 Ornamental Louvre 900 see illustrated detail 57 Castle 300 260 295 200 250 90 22 *see notes on pages 34 and 35 regarding limited application.

Ornamental 83 78 47 26 90 56 82 Ornamental No. A B C D 26 Three Rib Roll 450, 600, 750, 900 265 300 200 260 47 Three Groove Roll 750 265 295 210 260 56 Four Ring Roll 375 265 300 200 260 78 Beaded Cannon Head 550 250 290 210 320 82 Ornamental Round 600 265 295 210 250 83 London Roll 600 265 300 220 265 90 Moulded Taper 600, 750 250 290 210 250 23

Ornamental cont. 93 91 76 94 20 92 295 270 165 65 150 235 290 250 210 160 65 115 75 265 300 435 210 265 300 350 Ornamental No. A B C D E F 20 Four Pocket Roll 450, 600 265 295 200 260 325 250 * 76 Weemac 900 see illustrated detail * 91 Irish Roll 300, 375, 450 210 250 175 240 600, 750, 900 * 92 Rectangular Taper 300 see illustrated detail 93 Moulded Taper 550 265 295 200 245 * 94 Hooded Pot 525 215 250 300 200 245 115 24 *see notes on pages 34 and 35 regarding limited application.

Ornamental 3 52 113 18 65 14 390 250 140 185 220 90 295 325 Ornamental No. A B C D E F 3 Plain Beehive 300, 375, 450, 600, 675 250 290 200 265 750, 900 14 Pocket Beehive 300, 375, 450, 600, 750 250 290 200 260 18 Lady Broughton 900, 900 see illustrated detail 52 Dublin Can 600, 750, 900 260 295 210 240 65 Jamieson 600, 750 260 290 200 245 315 215 113 Capped Can 700 265 300 215 250 350 215 25

Specials Spiral Pattern Diamond Pattern 634 Captain Pot Fleur-de-Lys Pattern Specials 26 No. A B C D E F 634 Captain Pot available in any 360 425 370 530 245 325 size according to requirements

Specials Specials Red Bank Specials are available in any size according to requirements. Please contact Red Bank for further information and assistance. 27

Inserts The Red Bank range of Inserts are real high flyers for any chimney, offering practical solutions to open top problems. Inserts List Description Spigot Height Hood No. ext. dia Spigot O/all Width E A B C D * 29 Cowl Top 190 55 280 580 140 205 55 280 580 170 * 30 Hood Top 135 50 250 200 100 170 50 250 200 125 190 50 250 200 145 205 50 250 200 170 235 50 250 250 200 * 103 Hood Top see illustrated detail (Square Spigot) 28 *see notes on pages 34 and 35 regarding limited application.

Inserts Inserts 103 29 116 30 117 118 119 120 300 300 495 rad 215 dia 200 140 250 50 250 140 125 40 175 350 110 65 290 275 300 12-25mm dia holes equally spaced Inserts List Description Spigot Height No. ext. dia Spigot O/all A B C D * 116 Weatherguard 135, 170 85 170 235 Top 190, 205 85 170 285 * 117 Blank Stopper 135 40 75 185 170, 190, 205 70 125 250 * 118 Mushroom Top 190 100 280 300 Fitting Recommendations Inserts to be mortar bedded to 205 100 300 300 top of chimney pot to provide a weather seal. * 119 Mushroom Top see illustrated detail (Outside Fitting) * 120 Flue Ventilator 135, 190, 205 55 175 275 Please Note: Suitable for ventilation only. Not suitable for 235 70 175 325 any live appliance. This includes gas, solid fuel and oil. 170 55 175 250 List No. 117 does not provide ventilation. *see notes on pages 34 and 35 regarding limited application. 29

Gas Flue Terminals You ll find Red Bank s range of Gas Flue Terminals gliding along many rooftops offering total solutions for gas flue applications. 30

Gas Flue Terminals Gas Flue Terminals 612 617 610 636 Plate for use with GC10 Clay Can 611 613 165 190 Gas Flue Terminals List Description Spigot Spigot Height No. A int. dia B ext. dia C D H * 610 GC2 Base 260 150 * 611 GC2 Top 300 190 * 612 GC2 Insert 130 170, 190, 205 300 400 * 613 GC3 Insert 150 180, 205 300 440 * 617 GC2 Insert Square 130 170 300 270 sq 400 * 636 GC10 Clay Can & plate see illustrated detail *see notes on pages 34 and 35 regarding limited application. 31

Gas Flue Terminals cont. 534 624 618 623 625 295 170 190 760 550 400 190 295 sq 250 sq 340 sq Gas Flue Terminals List Description External Internal Minimum internal Height Top Spigot No. Spigot Spigot chimney pot / flue H C Height Dia A Dia B terminal dimension E * 534 GC9 see illustrated detail * 618 Bishop GC2 see illustrated detail * 623 Stangas 190 145 200 335 245 100 * 623 Stangas 205 170 225 350 245 120 * 624 Crowned GC5 170 125 185 385 240 145 * 624 Crowned GC5 190 140 200 385 240 145 * 625 GC5 170 125 185 300 260 140 * 625 GC5 190 140 200 300 260 140 * 625 GC5 205 170 225 300 260 140 32 *see notes on pages 34 and 35 regarding limited application.

Gas Flue Terminals Decorative Fuel Effect Pots and Inserts 146 146 145 Square skirt Decorative Fuel Effect Pots and Inserts List Description Height H External Internal No. Dimension A Dimension B * 145 DFE Pots 560, 710, 860 300 265 * 146 DFE Insert 435 205 175 * 146 DFE Insert 450 235 200 * 146 DFE Insert 470 270 220 * 146 DFE Sqr Insert 470 210 sq 320 sq skirt 185 sq * 146 DFE Sqr Insert 470 235 sq 320 sq skirt 205 sq * 146 DFE Sqr Insert 470 270 sq 370 sq skirt 235 sq *see notes on pages 34 and 35 regarding limited application. 33

Chimney Pots & Flue Terminals The design profile and outlet dimensions of the chimney pot or flue terminal should preferably equate to the shape and cross sectional area of the flue lining. Minimum recommended dimensions are dependent on the size of the fireplace opening, size of the flue lining or appliance outlet, type of fuel and/or appliance. Chimney Pots and Flue Terminals suitable for use with Solid Fuel Open Fires and Closed Appliances. Fireplace with an opening of up to 500mm x 550mm: minimum 200mm diameter or equivalent square/rectangular cross sectional area with no dimension less than 175mm Fireplace with an opening in excess of 500mm x 550mm: flue and terminal outlet equivalent to 15% of the area of the fireplace opening with no dimension less than 200mm. Closed Appliance up to 20kW rated output: minimum 125mm diameter or equivalent square/rectangular cross sectional area, with no dimension less than 100mm on straight flues or 125mm on flue with bends or offsets. Closed Appliance up to 30kW rated output minimum 150mm diameter or rectangular/square cross sectional area with no dimension less than 125mm. Chimney Pots and Flue Terminals suitable for use with natural draft open-flued Gas Burning Appliances. Flue sizes up to 170mm diameter should be fitted with an approved gas terminal complying with BS 715:1993 and BS 1289-1:1986 as shown on pages 31 and 32. Flue sizes in excess of 170mm diameter may be fitted with suitable terminals to prevent ingress if the total free area of the outlets is at least twice the cross-sectional area of the flue. Chimney Pots and Flue Terminals suitable for use with Oil Burning Appliances Minimum dimensions should be the same size or equivalent to the cross-sectional area of the appliance flue outlet. Suitable terminals may be used to prevent ingress if the total free area of the outlets is at least twice the cross-sectional area of the flue. Note: The majority of chimney pots and flue terminals included on pages 4-27 are suitable for use with solid fuel open fires and appliances dependent on the crosssectional area of the outlet. Some traditional patterns may not meet all current requirements but have time proven performance characteristics. Due to the diversity in design and varied application the notes provided on limited and suitable application are for guidance only. Specifiers and installers must ensure that all products are suitable for the intended application and meet all appropriate regulations and installations requirements. If further assistance is required please contact Red Bank's Technical Services Department. Page No. List No. Description / Size Limited application Suitable application 7 175 176 178 150mm int. dia. top 150mm int. dia. top 150mm int. dia. top Not suitable for use with solid fuel open fires or gas appliances May be used with solid fuel closed or oil fired appliances dependent on the size of the flue and area of flue outlet 8 121-185 185mm dia. top Traditional pattern has been used extensively with solid fuel open fires, internal top dimension does not meet current recommendations May be used with solid fuel closed appliances, gas and oil fired appliances dependent on the size of the flue and area of the flue outlet 9 36 175mm int. dia. top Not suitable for use with solid fuel open fires May be used with solid fuel closed appliances gas and oil fired appliances dependent on the size of the flue and area of the flue outlet 39 150mm int. dia. top Not suitable for use with solid fuel open fires and gas appliances May be used with solid fuel closed appliances and oil fired appliances dependent the size of the flue and area of the flue outlet 53 With fixed hood Not suitable for use with any live flue For ventilation only 10 69 160mm int.sq.top Not suitable for use with solid fuel open fires or gas appliances May be used with solid fuel closed and oil fired appliances dependent on the size of the flue and area of the flue outlet 11 5 100mm int. dia.spigot Not suitable for use with solid fuel open fires or closed appliances or gas fired appliances May be used with oil fired appliances dependent on the size of the flue and area of the flue outlet. 5 5 5 125mm int. dia.spigot 145mm int. dia.spigot 170mm int. dia.spigot Not suitable for use with solid fuel open fires and gas appliances and some solid fuel closed appliances May be used with some solid fuel closed and oil fired appliances dependent on the size of the flue and area of the flue outlet 12 13 Capped Louvre Capped Louvre Insert Not suitable for use with solid fuel open fires or closed appliances or gas appliances May be used with some oil fired appliances dependent on the size of the flue and area of the flue outlet 13 74 Hooded Louvre Top Not suitable with any live flue For ventilation only 106 107 108 109 165 x 225mm int. rectangular top Traditional pattern has been used extensively with solid fuel open fires, minimum internal top dimension less than 175mm but total cross section area of outlets in excess of equivalent 200mm int. dia. May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet 15 58 150mm int. dia. top Not suitable for solid fuel open fires or gas appliances May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet 60 175mm int. dia. top Traditional pattern has been used extensively with solid fuel open fires, internal top dimension does not meet current recommendations but total cross section area of outlets in excess of equivalent 200mm int. dia. May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet 112 Venetian Cap Not suitable for use with any live flue For ventilation only 16 10 160mm int. dia. barrel Not suitable for solid fuel open fires or gas appliances May be used with solid fuel open fires and closed and oil fired appliances dependent on the size of the flue and area of the flue outlet 59 185mm int. dia. outlet Traditional pattern has been used extensively with solid fuel open fires, internal outlet dimension does not meet current recommendations May be used with solid fuel closed appliances gas and oil fired appliances dependent on the size of the flue and area of the flue outlet 34

Suitability and Application Notes Page No. List No. Description / Size Limited application Suitable application 17 98 122 H Insert H Pot 150mm tube Not suitable for solid fuel open fires or gas appliances 21 34 150mm int. dia. top Not suitable for solid fuel open fires or gas appliances 22 44 150mm int. dia. barrel Not suitable for solid fuel open fires or gas appliances May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet 24 76 165mm int. dia. top Not suitable for solid fuel open fires and gas appliances May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet 91 175mm int. dia. top Not suitable for solid fuel open fires May be used with solid fuel closed appliances gas and oil fired appliances dependent on the size of the flue and area of the flue outlet 92 160 x 250mm int. rectangular top Traditional pattern has been used extensively with solid fuel open fires, minimum internal top dimension less than 175mm but total cross sectional area of outlet in excess of equivalent 200mm int. dia. May be used with solid fuel closed appliances and oil fired appliances dependent on the size of the flue and area of the flue outlet 94 Hooded Pot Not suitable for use with live flue For Ventilation only Inserts Page No. List No. Description / Size Limited application Suitable application 28 29 Cowl Top Not suitable for use with solid fuel open fires or gas appliances May be used with solid fuel closed and oil fired appliances dependent on the size of the flue and area of the flue outlet 30 103 Hood Top Not suitable for use with any live flue serving solid fuel open fire or closed appliance, gas or oil fired appliance For ventilation only 29 116 118 119 120 Weatherguard Top Mushroom Top Flue Ventilator Not suitable for use with any live flue serving solid fuel open fire or closed appliance, gas or oil fired appliance For ventilation only 117 Blank Stopper Not suitable for use with any live flue, does not provide ventilation For blanking off only Gas Flue Terminals Page No. List No. Description / Size Limited application Suitable application 31 610 611 636 GC2 Base GC2 Top GC2 Can Not suitable for use with Decorative Fuel Effect gas fires and Inset Live Fuel Effect gas fires requiring minimum 175mm flue or solid fuel open fires and appliances May be used with all types of approved gas fired appliances including standard radiant gas fires with flue outlets up to 125mm dia. outlet where flueway has been lined with 125mm int. dia flexible metal liner 613 Not suitable for use with Decorative Fuel Effect gas fires and Inset Live Fuel Effect gas fires requiring minimum 175mm flue or solid fuel open fires and appliances May be used with all types of approved gas fired appliances with flue outlet up to 150mm dia. 31/32 612 613 617 618 623 624 625 GC2 Insert GC3 Insert GC2 Insert Bishop GC2 Stangas Crowned GC5 GC5 Insert Not suitable for use with Decorative Fuel Effect gas fires and Inset Live Fuel effect gas fires requiring minimum 175mm dia flue or solid fuel open fires and appliances 534 GC9 Not suitable for use with solid fuel open fires or appliances May be used with all types of approved gas fired appliances including standard radiant gas fires with flue outlets up to 125mm dia. outlet and some Inset Live Fuel Effect gas fires, classified by appliance manufacturer as suitable for use with Class 2 Flue Blocks Suitable for use with Decorative Fuel Effect gas fires and Inset Live Fuel Effect gas fires requiring minimum 175mm int. dia. flue, maximum recommended flue size 200 x 200mm int. square or 225mm int. dia. 33 145 DFE Pot Not suitable for use with Class 2 flue blocks or where gas flueway has been reduced to less than 175mm int. dia. Suitable for use with Decorative Fuel Effect gas fires and Inset Live Fuel Effect gas fires requiring minimum 175mm int. dia. flue, maximum recommended flue size 225mm int. dia. or equivalent square section. May also be used with solid fuel open fires to help reduce rain penetration. 146 DFE Insert 205mm ext. dia. and 210mm ext. square spigot Not suitable for use with Class 2 flue blocks or where gas flueway has been reduced to less than 175mm int. dia. Solid fuel open fires or where flue terminal is less than 225mm int. dia. Suitable for use with Decorative Fuel Effect gas fires and Inset Live Fuel Effect gas fires requiring minimum 175mm int. dia. flue, maximum recommended flue size 225mm int. dia. or equivalent square section. 146 DFE Insert 235mm, 270mm ext. dia. and 235mm, 270mm ext. square spigot Not suitable for use with Class 2 flue blocks or where gas flueway has been reduced to less than 175mm int. dia. Suitable for use with Decorative Fuel Effect gas fires requiring minimum 175mm int. dia. flue. May also be used with larger flue sizes dependent on the appliance manufacturers recommendations and the internal and external dimension of the spigot 35

Red Bank Manufacturing Company Limited Atherstone Road, Measham, Swadlincote, Derbyshire DE12 7EL FREEPHONE Direct Sales Line (0800) 3285243 FREE FAX (0800) 7315944 Clayware Sales: (01530) 273737 All Other Depts: (01530) 270333 Fax: (01530) 270542 / 273667 / 273826 E-mail: admin@redbankmfg.co.uk Website: www.redbankmfg.co.uk BUILDING MASTERPIECES Quality Assured Q5001 Designed & Produced by S.A.M. Design Consultants Ltd. 01332 298088