COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

Similar documents
COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

COOPER POWER SERIES. QD3 Quik-Drive Tap-Changer Position Indicator Drive Gear Kit Number B11. Voltage Regulators MN225056EN

COOPER POWER SERIES. Mounting bracket KA19H3 assembly and installation instructions. Reclosers MN280072EN

COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

Effective May 2017 Supersedes October 1998 (S )

COOPER POWER SERIES. Reclosers MN280015EN

S Voltage Regulators

Instruction Leaflet for the K-Frame, L-Frame, M-Frame, N-Frame and R-Frame 310+ Mining Trip Units

TrueClean ToteCleaner

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Elevator Control ES Switch

TrueClean ToteCleaner

Owner & Operator Manual

Owner & Operator Manual

User Guide. Contents. About this guide. i-on Style Security System

OPERATION, SERVICE & PARTS MANUAL

Duct Mount. Installation Instructions

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

ELECTRIC FIRE PUMP CONTROLLER

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

MaxLite LED MICRO-T PANEL

Installation Instructions

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

(HSTAT Series) Instruction Manual

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

XT Series Thermostats

OPERATION, SERVICE & PARTS MANUAL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

HotPoly Tote Tank / IBC Heaters (TTH Series)

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Instruction Manual. Double Candy Apple Cooker

Communications Point Data Base for Communications Protocol IEC

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

USER MANUAL SAVE THESE INSTRUCTIONS

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Installation & Operation Manual

MN908 No. 282C Replaces 282B LB7013

High Temperature Remote Gas Calibrator

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Training Yard Control Panel

SAVE THESE INSTRUCTIONS

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

MODEL HBX-1 P/N 3G59332

CPL Series Pedestal Convection Heater

Corrosion Resistant Fluid and Air Handling Systems.

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Industrial Vacuums, Inc

Document No

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Ultrasonic Reflective Sensor

Phoenix AirMAX - Radial Air Mover

SYSTEM CONTROL KIT Model: CK-41P

Installation & Operation Manual

INSTALLATION INSTRUCTIONS

GETZ MANUFACTURING PART # CYLINDER DRYER

MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Inline Heater for Solvent or Gas. Installation and Operation Manual

55-Gallon Dispenser Package

OKB, OKD, & OKH Series

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Blade Series Heat Exchanger Operation and Installation

WDB2 Series Bearing Temperature Sensor

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Hot Dog Roller Grills

Installation and Maintenance "L" and "LS" Series

20 High velocity Air

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

NG4access ODF Platform Standard Chassis Installation Manual

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

120 VAC SYSTEM CONTROL KIT

Owner's Manual. Automatic Sliding Doors. for CONTENTS A U T O M A T I C S. A Member of: Distributed by:

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

Non-Programmable Digital Thermostat

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Document No B1 February Atlantic Ultraviolet Corporation

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Installation Manual. Model 600A1. Moisture Sensor Kit for Large Square Balers 600A1-15-INST 2/15

120 VAC SYSTEM CONTROL KIT Model: CK-63

Safety & Installation Instructions

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Transcription:

Fault Indicators MN320004EN Effective March 2017 Supersedes August 2004 (S320-42-2) S.T.A.R. TM Fiber optic cable installation instructions COOPER POWER SERIES Fiber optic fitting (To led display) Mounting Wall Bushing 21 / 64 Diameter hole Outer display fitting

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. Installation Instructions MN320004EN March 2017 i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... i Safety for life... iii Safety information... iii Safety instructions... iii PRODUCT INFORMATION.... 1 INSTALLATION PROCEDURES.... 1 Installation instructions for remote fiber optic display...1 ii Installation Instructions MN320004EN March 2017

! SAFETY FOR LIFE Safety for life Eaton s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission.! SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result In death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with high voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply may result in death, severe personal injury and equipment damage. Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install, or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. Installation Instructions MN320004EN March 2017 iii

S.T.A.R. TM Fiber optic cable installation instructions CAUTION The Eaton Cooper Power series S.T.A.R. faulted circuit indicators are designed to be operated in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operating procedures. Read all the instructions before installing the faulted circuit indicator. Faulted circuit indicators should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. Improper operation, handling, or maintenance can result in death, severe personal injury, and equipment damage. resistance. Consult enclosure manufacturer for recommendation. 2. Ensure that the fiber optic fitting has been snapped onto the LED display of the FCI housing. If this was not done prior to installing the FCI on a live elbow, use gloved hands to snap the fiber optic fitting of the remote display cable onto the LED display of the FCI. Mounting Wall Bushing Fiber optic fitting (To led display) Product information The Eaton Cooper Power series S.T.A.R. Fiber Optic Cable can be used to provide remote fault indication for the LED display on the S.T.A.R. Delayed Reset (DR) and Variable Trip Test Point Reset faulted circuit indicators (FCI). The cable is easily installed by pushing the fiber optic fitting onto the LED display of the FCI housing and attaching the remote display to the enclosure wall using the fittings provided. Installation procedures Installation instructions for remote fiber optic display The Eaton Cooper Power series S.T.A.R. Faulted Circuit Indicator with remote display and/or auxiliary contact outputs are designed for installation at Ground Potential Only. Remote indicators and auxiliary contacts are not insulated for high voltage application. If high voltage is applied across the fault indicator, flashover may occur, possibly resulting in death, severe personal injury, and equipment damage. 1. Drill one 21/64 inch diameter hole as shown in Figure 1. Hole rim may need to be treated for corrosion Outer display fitting 21/64 Diameter hole Figure 1. Remote fiber optic cable display installation diagram 3. Insert the outer fitting through the 21/64 inch diameter hole with the threads extending through the hole in the enclosure. 4. Insert the end of the fiber optic cable into the outer display fitting. 5. Thread the bushing at the end of the fiber optic cable, onto the outer fitting. 6. Adjust the display to the desired alignment and tighten the nut to pull the outer fitting against the front of the enclosure. Tighten sufficiently to prevent removal of the outer fitting from outside the cabinet, but do not overtighten the nuts. These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, contact your Eaton representative. 1 Installation Instructions MN320004EN March 2017

S.T.A.R. TM Fiber optic cable installation instructions This page intentionally left blank. Installation Instructions MN320004EN March 2017 2

S.T.A.R. TM Fiber optic cable installation instructions This page intentionally left blank. 3 Installation Instructions MN320004EN March 2017

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN320004EN March 2017 #5000050840 Rev. 2 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.