WATER/WASTE SYSTEM - SERVICING

Similar documents
Canadair Regional Jet 100/200 - Water & Waste

IN ORDER TO PERFORM THESE TASKS, YOU WILL NEED THREE THINGS:

PRE-INSTALLATION PROCEDURE

PRE INSTALLATION PROCEDURES

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

BEFORE OPERATING THE MACHINE: WARNING

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Refrigerator. Installation Guide. Free Standing Appliance

Service Bulletin

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

Symphony Plus Pressurized Water Sanitizing Kit P/N

BMW E36 Thermostat Removal And Coolant Flush

STEAM WALLPAPER STRIPPER MODEL HTW5

PORTABLE SMART WASHER

VARIABLE RATE INFUSION PUMP

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

PRE INSTALLATION PROCEDURES

INSTRUCTION MANUAL OF WATER DISPENSER ΜΟDEL: CLWD-19PW

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Automatic Water System Pump SERIES

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

PRE INSTALLATION PROCEDURES

Instruction Manual for Electric Marine Toilets LT-0E and LT-1E

17 GALLON PROFESSIONAL RESTROOM CLEANER

INSTALLATION INSTRUCTIONS WARRANTY

user manual Dishwasher ESL 46510

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

DF-50 DIFFUSION HAZER

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

A AMM - TOILET SYSTEM - DESCRIPTION AND OPERATION

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

2001 Smith Eastern Corporation

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

OPER LV Wheeler Way

Cameo White January (first two digits indicate the month of expiration, 01 12)

Hoshizaki America, Inc.

EXTREME 1 Reverse Osmosis System

Bombardier Challenger Fire Protection

Replacing a Gun Thermostat

EXTREME HP-1 Reverse Osmosis System

Power-Spin. Drain Cleaner Operator s Manual

Aquaversa. Installation Guide

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Oscillating Belt/Spindle Sander 230V

A/C-HEATER SYSTEM - MANUAL

SERVICE REQUIREMENTS

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Chapter 5 Checks and Maintenance

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

USER OPERATING MANUAL

_Bonide Maize Weed Preventer Ready to Spray_ _240_4_.pdf. Ready to Spray

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Kiddie After Discharge Clean-Up

CALIBRATION KIT #

NBSeries Installation Operation & Maintenance

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

The Handle The Flush Valve And the Ballcock

CHAPTER 11 HEATING AND VENTILATION

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

10-SPEED BLENDER. Instruction Manual. Model: CBL V/60Hz / 400W

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

HEATING AND AIR CONDITIONING

MODEL SF-420. Fabric Steamer. by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card.

NILEATOR ATOR. Dyna-Fog ANILE. Cold Fog ULV Aerosol Applicator. Instruction Manual For Operation, Service and Maintenance

Installation, commissioning and servicing instructions

WL380 QUICK START GUIDE

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

STANDARD OPERATING PROCEDURES

Installing the Turbo Floor Model System

G.I. Procedures. Handbook

Electronic Service Manuals

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

1 of 8 5/11/17, 10:01 AM

QUICK Install Guide 400A FILL VALVE INSTALL WITH CONFIDENCE. *See back page for important legal information.

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

Endoscope Reprocessor Installation Instructions Endoscope Reprocessing System

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

User information. Cleaning/descaling and sanitizing

Cleaning and Sanitation Procedures Module Deli

Sleeper Heater and Air Conditioner, Blend Air System 83.05

ENGINE PREHEATER. Operating Instructions and Parts Manual. For Models: H H LT 2-12 MH-300 LT 2-12 MH-310 LT 2-12 MH-200 LT 2-12 MH-210

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

DC3Training.com N28AA DC-3 Pilot s Handbook

IMPORTANT SAFEGUARDS

TOILET SYSTEM - DESCRIPTION AND OPERATION

INSTRUCTION MANUAL Vacuum Cleaner Model No.: VB-100

Dust caps, electrical connector DPM Commercially available Hoisting rope Ref. ITEL FX 572, 624, 625, 628, 631, FX ALL

Operator Manual - Workman Wet/Dry Vacuums IMPORTANT SAFETY INSTRUCTIONS

Tornado Operations & Maintenance Manual

13 GALLON Extractor MODEL NO

Chemical Transfer Pump Tube Set and Adapter Instructions

Transcription:

WATER/WASTE SYSTEM - SERVICING TASK and 5331 to 5700 TASK 613 801 1. Servicing of the Lavatory Water System A. Reference Information REFERENCE TASK 24 00 00 910 801 Electrical/Electronic Safety Precautions B. Tools and Equipment REFERENCE GSE Commercially Available Connector Kit, Potable Water Unit, Ground Fill, Clean Water Container, 10 U.S. Gallons (37.85 Liters) NOTE: Refer to the Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration. C. Consumable Materials REFERENCE MANUFACTURERS REFERENCE AND/OR SPECIFICATION Not Specified Water, Clean N/A D. Job Set Up WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC EQUIPMENT. YOU CAN CAUSE INJURIES TO PERSONS AND DAMAGE TO THE EQUIPMENT. (1) Obey all the electrical/electronic safety precautions (TASK 24 00 00 910 801). Page 301

(2) Make sure that the circuit breaker that follows is closed: LOCATION CB NUMBER CB NAME ZONE CBP 5 A8 EXT SERV 311 (3) Open the access doors that follow: ACCESS 311BB 172AR Door, Aft Equipment Compartment Door, Potable Water Servicing Point E. Procedure Refer to Figure 301. (1) Put a container below the drain mast (1) to catch the water from the lavatory water tank. (2) Turn the drain handle (6) a quarter turn clockwise and pull it out to the open position. (3) Turn the drain handle (6) a quarter turn counterclockwise. (4) Make sure the drain handle is locked into position. (5) Water will flow from the drain mast. (6) Make sure the EMPTY light comes on when the water flow stops. (7) Turn the drain handle (6) a quarter turn clockwise and push it in to the closed position. (8) Turn the drain handle (6) a quarter turn counterclockwise. (9) Make sure the drain handle is locked in position. (10) Remove the cap (7) from the fill adapter (8). (11) Connect the fill hose of the clean water ground fill unit to the fill adapter (8). (12) Put the switch (4) to ON. (13) Start the flow of clean water from the ground fill unit to the lavatory water system. (14) Stop the flow when all of the FULL lights (3) come ON on the panel. Page 302

(15) Put the switch (4) to OFF. (16) Remove the fill hose from the fill adapter (8). (17) Put the cap (7) on the fill adapter (8). F. Close Out (1) Remove all tools, equipment, and unwanted materials from the work area. (2) Close the access doors that follow: ACCESS 311BB 172AR Door, Aft Equipment Compartment Door, Potable Water Servicing Point Page 303

8 1 6 2 7 3 B 5 4 B LMM1218013_001 Lavatory Water System Servicing Figure 301 Page 304

TASK and 5331 to 5700 TASK 613 802 2. Servicing of the Waste Water System A. Tools and Equipment CL 604 AIRCRAFT MAINTENANCE MANUAL PART II REFERENCE GSE 12 00 10 TBD Unit, Lavatory Service Unit, Ground Fill, Clean Water NOTE: Refer to the Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration. B. Consumable Materials REFERENCE MANUFACTURERS REFERENCE AND/OR SPECIFICATION 05 110 Gloves, Protective Latex Commercially Available 11 003 Toilet Fluid, Styx 99 AGMA, Styx 99 Chemical, Toilet, Monogram MC 1000 or MC 2000 Commercially Available C. Job Set Up (1) Open the access door that follows: ACCESS 172CR Door, Waste Water Servicing Point D. Procedure Refer to Figure 302. WARNING: USE RUBBER GLOVES WHEN YOU DO THE SERVICING OF THE WASTE WATER SYSTEM. WASTE WATER CAN GET ON YOUR HANDS AND CAUSE INFECTION. (1) Pull up on the handle and open the waste valve cap (4). (2) Pull up on the handle and open the fill port cap (5). Page 305

(3) Connect the fill hose of the clean water ground fill unit to the fill port (6). (4) Connect the waste drain hose from the toilet servicing unit to the waste valve (3). (5) Push the valve lever (2) to open. (6) Turn the handle (1) a quarter turn counterclockwise and pull it out to the open position. (7) Turn the handle (1) a quarter turn clockwise. (8) Make sure the handle (1) is locked in position. (9) Make sure you hear the sound of the liquid flow before you start to flush the system. CAUTION: DO NOT CONTINUE TO FLUSH THE SYSTEM IF YOU THINK THERE IS A BLOCKAGE. THE WATER PRESSURE MAY CAUSE THE CONTENTS OF THE TANK TO FLOW OUT OF THE TOP OF THE TOILET. (10) Start the flow of clean water from the ground fill unit to the waste water system. (11) Let the water flow through the system until the flow in the supply hose and the waste hose are approximately equal. (12) Turn the handle (1) a quarter turn counterclockwise and push it in to the closed position. (13) Turn the handle (1) a quarter turn clockwise. (14) Fill the tank with approximately 12 gallons (45 liters) of clean water. (15) Open the handle (1) and let the water drain from the tank. (16) Close the handle (1). (17) Remove the hose from the waste valve (3). NOTE: The valve lever (2) has a spring that will close automatically when you close the waste valve cap (4). (18) Close the waste valve cap (4). (19) Make sure the spring releases the valve lever (2). (20) Remove the hose from the fill port (6). (21) Close the fill port cap (5). (22) Open the fill port cap (5). (23) Attach the fill hose from the toilet servicing unit to the fill port (6). Page 306

(24) For Styx 99 Toilet Fluid, prepare a mixture of 293.51 oz (8 680.27 ml) of clean water and 0.67 oz (19.73 ml) of Styx 99 fluid. (25) Fill the toilet tank with 294.27 oz (8 700 ml) of chemical/water solution. (26) Remove the hose from the fill port (6). (27) Close the fill port cap (5). E. Close Out CL 604 AIRCRAFT MAINTENANCE MANUAL PART II (1) Remove all tools, equipment, and unwanted materials from the work area. (2) Close the access door that follows: ACCESS 172CR Door, Waste Water Servicing Point Page 307

1 2 3 6 5 4 LMM1218013_002 Waste Water System Servicing Figure 302 Page 308