RFID Card Access Control Unit. Operating Instructions

Similar documents
PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

Installation Guide & User Manual

WIRING DIAGRAM AND INSTRUCTIONS

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Operating Instructions Transponder code lock - Part 2 (split decoder)

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

DOLKPS1KB Programming & Installation Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

User Manual X8s Access Control System

C2 Compact Range Installation & Programming Manual

User Manual Keep this manual safe for future reference

User Manual YDM The functions and design of this product can be changed without notice for quality improvement. Chinese manual is from 33 page.

Installation Instructions

KT-100 Door Controller

HAA2866 HAA2866 ERRATUM

SPLIT-DECODED CONTROLLER

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD AND CARD READER

SCR100 User Manual. Version:1.1 Date:Dec 2009

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

GSM RFID VOICE Alarm System

NDC-F16. Access Control Panel. Installation Manual

QA16 Addressable System

Strikemaster ES Engineering Manual

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Security GSM Alarm System

SIB CATALOGUE. range. S100EM EM 125KHz 5-6cm. S100MF MIFARE 13.56KHz 3~5cm

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

REPEATER FS5200R INSTRUCTION MANUAL

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

MOBILE CALL GSM Alarm System User s Manual

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

UNC100 Integra Manual

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Installation/Owner s Manual Models 1504 / 1506

Touchpad Exit Controller Administration Guide

Facts about EM2050. MLS Software. EM2050 RotoBolt Electronic SwingBolt Lock USER INSTRUCTIONS To open (dual combo): AND

Operating instructions 2-channel code lock. Item No

1. Introduction. 2. Product overview

The door can be opened with a RF card. The door can be opened with a transit RF card. Up to 20 cards be registered.

Intelligent Wireless GSM Alarm System

Introduction. OM-THA2

Easikey 1000 / 1000 Plus

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

U ser's Guide PC6010

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Door Release Power Supply

Installation Manual RINS1211-4

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Installation & User Manual V1.1

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

CA60Plus. Installation manual

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Control box FSTronic DES-FS

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Paxton Ins PROXIMITY P50 compact kit. Technical Support. Suitability Security-sensitive doors

Vehicle Security System VSS3 - Vehicle original remote. Setting Guide - English

User Manual. Dryer Controller M720

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

ELECTRONIC GUN SAFE USER MANUAL. Models: SLSFE61GN - SLSFE63GN

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

InBio X60 Series Access Control Panel User Manual

User Manual (LS-GSM-006)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

PTE0705 Electric Fence Monitor

Advisor Advanced User Guide

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

INSTALLATION AND OPERATING MANUAL

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

G34 AU1B (External Ultrasonic Sensor) Version 3

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

DESCRIPTION OF KEYPAD (Access module with segments)

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

EasyTronic III MANUAL SERVICE

EVO192 v3.0 Fire and Burglary What s New

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Dryer Controller M720

Transponder reader TECHNICAL SHEET (White) (Magnesium)

Paradox Integration Module Settings Guide

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

CASS9000 Standalone FingerPrint Door Access System. User Manual

S/601 Controller Installation Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

Contents. Contents

Four-Door Access Controller User s Manual

AXS Strikemaster Engineering Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual

Transcription:

RFID Card Access Control Unit Operating Instructions 1

1. Product Specification Item Index Operating Voltage 12VDC+10%; Current 1.2A Lock Relay 12VDC/2A Environmental temperature working:0 C~45 C; storage:-10 C ~55 C Relative humidity RFID Card Capacity working:40%~90%rh;storage:-20%~90%rh 255 cards, a Personal PIN goes alone with each card 4-digits public PIN Capacity 1 Proximity Reader Frequency Compatible Cards Card Reading Distance 125KHz EM or EM compatible cards 5 15CM 2. The LED and Buzzer Status type Red LED Green LED Yellow LED Buzzer Normal Working State on flash Authorized Card Read /Valid PIN/Exit Button Pressed on on a short beep Wrong PIN Entered on flash a long beep Non Authorized Card Read on flash a long beep Acceptable Key Pressed on flash a short beep Door Sensor, Anti-Break Sensor Alarmed on flash continuous beeps Programming Mode on on flash 2 short beeps Key In Right Programming Instruction Key In Wrong Programming Instruction on on flash 2 short beeps on on flash 3 short beeps 3. The Factory Default of the Product Type Factory Default 6-digit Programming PIN 990101 Door Open Mode Authorized Card / Public PIN (Default Public PIN: 1234) Lock Relay Time 3 seconds 2

Anti-Break Sensor Alarm Door Sensor Alarm Authorized Card Stored Disabled Disabled none 4. Functions and Settings (All functions should be set in programming mode; the parameters can be set repeatedly; the effective setting should be the last one.) 1. Enter programming mode: Press [*]+[6 digits programming PIN],2 beeps; Under programming state, it should be noted that: 1)The controller cannot perform normal function instructions. 2)If there is no programming instruction within 20 seconds, system will automatically quit programming mode and enter the normal working mode. 3)Successfully set parameters, 2 beeps; 4)Fail to set parameters, 3 beeps; 5)Before some setting instruction is finished(i.e. the controller have already given off 2 beeps for successful setting, or 3 beeps for failed setting), if the input instruction is mistaken, press [*], the controller gives off a long beep, meaning that the setting of the instruction has been cancelled. 2. Change programming PIN: Press [0]+[6 digits new programming PIN]+[repeat 6 digits new programming PIN], 2 beeps; 3. Set door open mode: 1)Card or Public PIN: Press [1]+[0], 2 beeps; 2)Card plus Personal PIN; Press [1]+[1], 2 beeps; 4. Set Lock Relay Time: Press [2]+[TT], 2 beeps; TT represents unlocking time, second as unit; if unlocking time is 3 seconds, TT=03; 5. Set Public PIN: Press [3]+[4 digits public PIN], 2 beeps; Press [3]+[0000], 2 beeps, eliminate all public PIN 6. Set Anti-Break Alarm: 1)Disable anti-break alarm: press [4]+[0], 2 beeps; 2)Enable anti-break alarm: press [4]+[1], 2 beeps; 3

7. Enrolling Cards: Press [5]+[4 digits card code], after 2 beeps +[present a card to the controller], a beep, then 2 beeps, then the card was added successfully; Enrolling more cards, repeat above mentioned operating steps; 1) [4 digits card code]: a code defined by the customer himself, can be any number between 0000~9999; the code of each card should not be repeated; the code is also the individual PIN for card plus personal PIN access control mode; if the customer lost the setting card, he could cancel the card code from the controller, thus, cancel the card from the controller( details see how to delete authorized card); 2) After press [5], the controller gives 3 beeps, meaning that the card capacity of the controller is full; 3) After press [5] +[4 digits card code], the controller gives off 3 beeps, meaning that the code is repeated and need a new operation; 4) After press [5]+[ 4 digits card code] 2 beeps +[induce the card to be set before the controller], a beef, then 3 beeps, meaning that the card number has already been set meanwhile the card code has also been cancelled induce the card to be set before the controller ). 8. Deleting authorized card: 1)Code mode delete the authorized card: press [6]+[4 digits card code], 2 beeps; 2)Present the card to delete the authorized card: press [7]+[present the card to the controller], a beep, then 2 beeps; 3)Deleting multiple cards, repeat above mentioned operation; 4)Deleting all authorized cards: if the customer needs delete all cards, please restore the controller to factory defaults. 9. Set door sensor alarm state: 1) Disable door sensor alarm function: press [8]+[0], 2 beeps; 2) Enable door sensor alarm function: press [8]+[1], 2 beeps; 3) After turning on this function, the controller will give off continuous long beep when the door is not closed after normal opening, or the door is not opened through the controller; 10. Restore factory defaults: Press [9]+[86], 2 beeps, then 3 long beeps, 3 short beeps after 5 seconds, enter normal working state; 11. Exit programming state: Press [*], 2 beeps; Under programming mode, if there is no programming instruction within 20 seconds, the system will automatically quit the programming mode and enter normal working mode. 4

5. Users Instructions: 1. Card or public PIN mode: 1)Read authorized card: After a short beep, green light is on, yellow light is off and the door is open. 2) Public PIN entered: Green light is on, yellow light is off and the door is open; The customer should continuously type in 4 digits public PIN; the interval between each key pressing should be less than 2 seconds. If the interval is more than 2 seconds, the system will automatically quit this time s PIN input. 3)If the customer entered the wrong PIN, press [*], and enter the right PIN again to open the lock. 2. Door opening mode of card + PIN 1) Read authorized card, after a beep, (1) Enter the right 4 digits PIN (code) within 5 seconds, the green light is on and the door is unlocked; (2) Not enter the PIN within 5 seconds, the buzzer gives off a long beep and the door is not unlocked; (3) Wrong 4 digits PIN is entered, the buzzer gives off a long beep and the door stays locked; read card again, enter the right PIN to unlock the door. (4) Wrong PIN for less than 4 digits, press [*], need not to read card again, directly input the right PIN and unlock the door; 2)Read unauthorized card, the buzzer gives off a beep, then a long beep when pressing the first PIN, and the door stays locked. 6. Installation: 1. Cautions during installation: 1) There should not be 100KHz 150 KHz frequency source within 50CM of the controller in the installation; 2) The installation distance between 2 unifying machines, or 1 unifying machine and other 125 KHz card reader should be 50CM; 3) When the customer sets Check door sensor when unlocking, the controller checks door sensor open and close state during unlocking; when the door sensor is separated, the controller regards the door opened already. At this time, except pressing fire control door opening button, the controller will keep the door locked no matter using any other door opening mode. 2. Installation and line connection: 1)Must cut off 12VDC power supply during installation and connection. Connecting with electricity is strictly prohibited!!! 7. Force to restore factory defaults: 5

1. Remove the controller; 2. Use metal tweeter to short connect the J2, the controller gives off a beep, then 2 beeps, and the restored factory default programming PIN is 990101; DOOR - + EXIT GND OPENSW 230Vac 50Hz EMERGENCY DOOR RELEASE BREAK GLASS PRESS HERE Power supply 12V dc 3A - + N/O N/C COM GND +12V 12V 7.2Ah Battery BELL BELL 1 2 3 JP2 Short 6