User Guide. Moisture Meter. Model MO230

Similar documents
User's Guide. Pinless Moisture Meter. Model MO257

Dual Laser InfraRed (IR) Thermometer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

EnnoLogic Moisture Meter eh710t Quick-Start Guide

4-in-1 Humidity, Temperature Airflow and Light Meter

Wet Bulb Thermo-Hygrometer Datalogger

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

USER GUIDE Heat Index Psychrometer

USER MANUAL Digital CO Monitor Model CO30

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

User's Guide. Pinless Moisture Meter. Model MO257

High Temperature InfraRed Thermometer with Laser Pointer

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Dual Laser InfraRed (IR) Thermometer

Pocket Moisture Meter Instruction Manual

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Indoor/Outdoor Temperature Alert

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

USER MANUAL USB Multi-Function Datalogger Model RHT35

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Premium Prefinished Hardwood Floor Accessories AFI Moldings

User's Guide. CO 2 Monitor. Model CO200

4-IN-1 PIN/PAD RH MOISTURE METER

Monteath. Monteath Dear Fellow Woodworkers: ?? Questions?? Please feel FREE to call

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Analog Room Pressure Monitor RPC Series

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Visit us at testo 835 Infrared and contact thermometer

Lines, Limbs & The Landscape

Intelli-Time Alarm Clock model 13041CAUDI

FTTHARCFUSIONSPLICER AD620

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

IRT2 Dual Laser IR Thermometer - User Guide

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Individual window solutions in aluminum and fine wood.

GasAlertMicroClip X3 Specifications

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Owner s Manual. Part Number 33CSCPACHP-01

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

Manual Swipe Luna Diamond Plus

Emerson Blue Easy Set 1H/1C

Smart thermostat with Humidification/De-humidification control

R2310. Infrared Thermometer. Instruction Manual

62 MAX/62 MAX + Infrared Thermometer. Users Manual

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Buttons on remote controller

STAYING IN... IS THE NEW GOING OUT

Instructions for use HYDROMETER Hydrometer GM-200 #071054

Instruments. for hydroponics & horticulture 2016

2. In 1959, the first full year the Arboretum was open 5,000 people visited. How many people visited in 2009?

HEAT HEAT HEAT COOL COOL

Thermostat Installation Best Practices

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

EGGER DECOR CHANGES. Organised by decor group

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Manual PCE-889 pyrometer

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

Product waste disposal - Protection of the environment:

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

T8401C Electronic Thermostats

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Weather Station model 02007

aura-t TP536/EU ventilation systems

Thermometer with Probe model 00891A

MT4 MAX/MT4 MAX + Infrared Thermometer

Weather Station with Remote Control Model: BAR289

GreenCon On/Off Room Thermostat

e. Wastes shall not have chlorine demand greater that fifteen (15) ppm. f. Wastes shall not contain phenols in excess of 0.05 ppm.

GreenCon On/Off Room Thermostat

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Model ST-128M Moisture Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20


1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

MultiFix Central unit

Alarm System SECURE AS 302

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Diplomat Inverter/Diplomat Duo Inverter

Manual Vane Anemometer PCE-VA 20

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

T105 Advanced Remote Control Programmable Thermostat. User Manual

aura-t TP536/GBR ventilation systems

P550W Series Air Dryers

Fire Command Keypad. XR5 User s Guide

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Thermometer with Wired Sensor

EST User Manual. (Please read this manual carefully before using)

OPERATING INSTRUCTIONS

Transcription:

User Guide Moisture Meter Model MO230

Introduction Congratulations on your purchase of the Extech MO230 Moisture Meter. The MO230 detects moisture in wood and building materials such as wall board, sheet rock, cardboard, paper, mortar, and plaster. Additionally, the meter measures Relative Humidity (RH) and Temperature. Careful use of this meter will provide years of reliable service. Description Meter Description 1. Protective Cap 2. Test Point pairs 3. Measurement electrode pins 4. Temperature and RH sensors 5. LCD 6. Hand grips 7. SET, CLEAR, and MODE/POWER buttons 6 3 1 2 4 5 7 Display Description 1. Measured value scale 2. Measured value 3. Relative Dry-Moist-Wet scale 4. Building mode and groups 5. Wood mode and groups 6. MAX value scale 7. TEST mode icon 8. Battery Status Indicator 9. Temperature or Relative Humidity display C F 8 9 7 6 5 TEST W2 W3 BUILD B1 B2 B3 B4 1 2 3 4 Note: The LCD screen is optimized for a 30 degree viewing angle. 2

Operation CAUTION: The electrode measurement pins are extremely sharp; Use care when handling. Cover the pins with the protective cap when the instrument is not in use. Getting Started 1. Remove the protective cap to expose the electrode measurement pins. 2. Press and hold the power button for 2 seconds to switch the meter ON. The ambient temperature will display and then the display will switch to the moisture measurement mode. Note: To conserve battery life, the meter automatically shuts off after 3 minutes. Measuring Temperature and Relative Humidity The MO230 measures ambient temperature and relative humidity via the built-in sensors at the top of the meter. The ambient temperature is used as a temperature compensation utility for moisture measurements. 1. The temperature or humidity reading is shown at the top of the LCD display window. 2. Press and hold the SET button for 2 seconds to switch from temperature display to humidity display. Note: Refer to the programming section of this guide for instructions on switching the temperature units of measure ( o C / o F). Measuring Moisture 1. The MO230 measures moisture via the pins affixed to the top of the meter. 2. Carefully push the electrode pins as far as possible into the material under test. The pins should be inserted into wood perpendicular to the wood s fiber structure. 3. Take several readings in several locations on the material for the best representation of the amount of moisture present. 4. Read the measurement values on the display. Readings are represented in. The measurement range for wood is 1 to 75. The measurement range for other building materials is 0.1 to 24. 5. Replace the protective cap when finished. C C Maximum (MAX) reading Indication The bargraph on the left side of the LCD display indicates and holds the highest reading encountered during a measurement session. Use the CLEAR button to reset the MAX reading indication. BUILD 3

Measurement Modes There are three (3) measurement modes. Momentarily press the MODE button to step from one mode to the next: WOOD MEASUREMENT MODE (WOOD GROUPS WI, W2, W3) BUILDING MEASUREMENT MODE (MATERIAL GROUPS B1, B2, B3, B4) SELF TEST MODE (TEST) Wood Measurement mode Momentarily press the MODE button to select the Wood Measurement Mode. Use the SET button to choose the desired wood group (W1, W2, W3) (refer to the Wood Group Table in the Appendix). W2 W3 Building Material Measurement Mode Momentarily press the MODE button to select the Building Measurement Mode and use the SET button to choose the desired building material group (B1, B2, B3, B4). (refer to the Building Material Group Table in the Appendix). BUILD B1 B2 B3 B4 Self Test Mode Momentarily press the MODE button to select the Self Test Mode. Touch the measurement pins to the test points labeled T on the protective cap. The display will read OK if the test passes (30 units ±2) or it will display dashes if the test fails. Next, touch the measurement pins to the test points labeled B. The display will read OK if the test passes (60 ±2) or it will display dashes if the test fails. If tests are failing please return the unit for repair or replacement. TEST Dry/Wet Indication Moisture reading will also be displayed on the user defined wet-moistdry display. Setting the range of the display is described in the programming section. 4

Programming Menu The programming menu offers five configurable parameters. To access the menu, turn the meter on, then simultaneously press and release the SET and CLEAR buttons. Once in the programming menu, use the MODE button to step through the TEMP parameters and also to exit the mode. Material Temperature Offset The first parameter in the programming menu is the material temperature offset feature. Use the SET button to increase the temperature value and use the CLEAR button to decrease the temperature value. Material moisture measurements can be dependent on the temperature of the material. This meter automatically compensates for material temperature changes by measuring ambient temperature. The temperature offset allows for adjusting the temperature reading when the material measured is not at ambient temperature.. Note: the temperature reading will return to normal when the meter is turned off. DRY/WET Scale The second and third parameters in the programming menu set the lower and upper range of the Dry-Wet scale. This relative scaling allows the user to specify what value is considered a DRY reading and what value is considered a WET reading. The values can be programmed from 0000 to 0999 (999=99.9). Use the SET button to increase the displayed value and use the CLEAR button to decrease the displayed value. F LCD Backlight Modes The fourth parameter is the LCD backlight configuration. There are three (3) LCD backlight modes: AUTO, ON, and OFF. In AUTO mode, the backlight switches ON and OFF automatically according to use. In the ON mode, the backlight is always ON. In the OFF mode, the backlight is always OFF. The default setting is the AUTO mode. Use the SET button to select the mode. Temperature units of measure ( C / F) The fifth mode is the temperature unit selection. The units of measure for ambient temperature and material compensation can be set to either C or F. The setting is stored and remains in effect until it is changed manually. Use the SET button to toggle the units. Maintenance Always keep the instrument dry Prevent dirt from accumulating at the electrode pins Electrode Pin Replacement To replace the two electrode pins: 1. Remove the protective cap 2. Unscrew the electrode pins 3. Install the new pins 4. Replace the protective cap 5

Battery Installation and Replacement If the instrument does not switch on or if it displays the low battery symbol, replace the batteries: 1. Remove the Phillips head screw at the rear of the instrument and remove the battery compartment cover. 2. Install new batteries (2) by placing the edge of the battery under to lip (3) and pressing the battery until the latch (1) locks the battery in place. 3. Observe the correct polarity when installing batteries. 4. Remove old batteries by pressing the latch (1) and allowing the battery to pop out. 5. Replace and secure the battery cover. Note: Do not mix old and new batteries, always replace all three batteries. 1 2 3 + You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Specifications Measurement Principle Electrical resistance Display LCD Measurements Moisture, Relative Humidity and Temperature Moisture Range Wood: 0 to 75; Building materials: 0.1 to 24 Relative Humidity Range 0 to 100 Temperature Range -40 to 70 C (-40 to 158 F) Electrode length 8mm (0.3 ) Electrode pins Integrated, replaceable Auto Power OFF After 3 minutes Power supply Three (3) CR-2032 button cells Operating Temperature 0 to 40 C (32 to 104 F) Operating Humidity 85 Relative Humidity maximum Housing material Impact resistant plastic Dimensions 159 x 63.5 x 30.5mm (6.25 x 2.5 x 1.2 ) Weight 100g (3.5 oz) Copyright 2010 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 6

Appendices Wood Groups W1 W1 W2 W3 Abachi Agda Mahogany Afrormosia Abura Maple Pine Rubber tree Pear wood Alder Cherry wood Imbuia Black Afara Patagonian cypress Kosipo Kokrodua Parana pine Purpleheart Larch Niove Bidinkala Beech Andiroba Limba Tola-real,red Dabema Aspen Cherry mahogany Cork Ebony Balsa Meleze Melamine particle board Oak,red Basralocus Poplar (all) Phenolic resin particle board Oak,white Tree Health Plum wood Ash Ebiara Pine Yellowheart Birch Red sandalwood Ash-American Logwood Elm Ash-Japanese Juniper Maritime pine Hichory-silver poplar Beech-European hombean English oak Hickory-swap Hombeam-white Durmast oak Ilomba Campeachy Tola Ipe Aiele Tola-branca Iroko Kapok Walnut Small-leaved lime Douka Westem red Small-leaved lime - American Douglas fir Cedar Mockemut hickory Oak White maple Niangon Oak-holm White birch Niove English,dumast White beech Okoume Emien White poplar Rosewood Alder-red,black Swiss pine Rio rosewood Ash Common aspen Common beech Yellow birch Damson wood Red oak Southem yellow pine Cypress,red Teak Hombeam Fibre board Willow Hickory-silver poplar Wood fibre insulating board White oak hickory-poplar Wood fibre hardboard Cedar Izombe Kauramin partide board Cypress - C. Lusit Guanandi Paper Board Jarrah Textiles Chestnut-sweet, red African Building Material Groups Elm Karri B1 B2 B3 B4 Gypsum plaster Aerated concrete Sand/Cement top mix Concrete 7