Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

Similar documents
Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Rosemount 752 Fieldbus Remote Indicator

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

Certificate of Compliance

Two global companies, one solution.

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Fieldbus Foundation TM Bus diagnostics and troubleshooting

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SET Installation and Operating Instructions. Level switch for one sensor

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

OilSET-1000 (12 VDC)

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

operational excellence Solutions for

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

SET-2000 Oil/Sludge 12 VDC

Beamex. Calibration White Paper. Calibration in hazardous areas

Annubar Flowmeter Series

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Hi Level/Oil

technical datasheet technical datasheet

Segment design & and Bus Diagnostics

Beamex Calibration White Paper. Calibration in hazardous areas

DB5 Intrinsically Safe Sounder Type DB-5

Operating Instructions Edition 02/2007

BA488CF Intrinsically safe Panel mounting Fieldbus Display

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Assembly. Host Sub-D Alarm

Model 144H. Product Data Sheet , Rev DB February Content

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

IECEx Certificate of Conformity

Instrumentation Products and Applications

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Certificate of Compliance

Model 144H. Product Data Sheet , Rev DB February Content

User s Manual YTA610 and YTA710 NEPSI Certification

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

Tank Gauging System Special Safety Instruction

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

segment, redundant FISCO power supply system for Yokogawa CENTUM CS 3000 Control Systems. Instruction Manual INM9108

Certificate of Compliance

OPTIBAR DP 7060 Supplementary Instructions

Certificate of Compliance

Intrinsically Safe or Explosionproof? Understanding the technology

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Certificate of Compliance

NET9000 Fieldbus Connections 912x-IS FISCO power supplies

Engineering Guideline. pac- Carriers Type Universal

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Intrinsically Safe Flame Detector Installation Guide

RT FLOW RATE TOTALISER

Fisher LCP100 Local Control Panel

custom cabinets and junction boxes

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Fire Alarm System Accessories

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

segment, redundant FISCO power supply system for Invensys Foxboro I/A Control Systems. Instruction Manual INM9101

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Technical Data. Dimensions

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Hazardous Area Classifications and Protections

IECEx Certificate of Conformity

AND INSTALLATION MANUAL

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

Certificate of Compliance

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Certificate of Compliance

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Foundation Fieldbus Usability from field Device Perspective. Hemal Desai Endress+Hauser India Pvt. Ltd 16 th October 2014 Automation 2014 Mumbai

Rosemount 752 Remote Indicator

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Product Information to the manual

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

ARC BRIEF. MTL: Expanding Opportunities with a Focus on Fundamentals. Keywords. Summary. Analysis THOUGHT LEADERS FOR MANUFACTURING & SUPPLY CHAIN

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Certificate of Compliance

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Understanding Hazardous Locations Concepts

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

IECEx Certificate of Conformity

Transcription:

Installing Foundation Fieldbus in Hazardous Areas Understanding your Options and How to Use Them

Typical Fieldbus Topology Fieldbus-based Field Instruments Fieldbus-based Field Instruments CONTROL/RACK ROOM (by DCS Vendor) FIELD (by EPC) Fieldbus Fieldbus Host Fieldbus Host Fieldbus Host Fieldbus Interfaces Host Interfaces Host Interfaces Interfaces Field Junction Box Control System Segment Power Segment Segment Power Segment Conditioners Power Conditioners Power Conditioners Conditioners Trunk Cables Spur Cables Field Junction Box 24VDC Bulk Power Supply 2 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Key Areas of Specification Is Redundancy required in Segment Power Conditioning? Is Isolation required between Segments within the same Fieldbus Host Interface? How many Devices do you desire per Fieldbus Segment? What Wiring Practice will be utilized between Power Conditioners in Rack Room and Field Junction Boxes? What Wiring Practice will be utilized between Field Junction Box and Field Instruments? What are the requirements for Surge Protection? 3 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Options Available for Hazardous Areas Zone 0/1 or Class 1 Division 1 Ex(i) Intrinsically Safe Ex(d) Flame Proof (Explosion Proof) Ex(e) Increased Safety (not allowed in C1D1) Zone 2 or Class 1 Division 2 Ex(nC/nL) Non-Incendive (Energy Limited) Ex(nA) Non-Sparking (Non-Arching) Defining in Specification is Critical to Obtaining Accurate Costs 4 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Non-Sparking/Non-Arching Trunk and Spurs Power Conditioners Mountable in : a) Safe Areas, b) Zone 2 IIC T4 Haz Areas & c) Class 1, Div 2, Groups A-D Haz Areas Control System Ex(nA) Power Conditioners CONTROL ROOM Ex(nA) Trunk NOT Live Workable FIELD Junction Box: Ex(n) or Ex(e) Megablock Certification Required: Ex(nA) Ex(n) or Ex(d) Fieldbus Devices Ex(nA) Spurs NOT Live Workable Zone 2 or Division 2 5 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Non-Sparking Trunk with Non-Incendive Spurs Power Conditioners Mountable in : a) Safe Areas, b) Zone 2 IIC T4 Haz Areas & c) Class 1, Div 2, Groups A-D Haz Areas Control System Ex(nA) Power Conditioners CONTROL ROOM Ex(nA) Trunk NOT Live Workable FIELD Junction Box: Ex(n) or Ex(e) Megablock Certification Required: Ex(nA) / Ex(nL) Ex(nL) or Ex(i) Fieldbus Devices Ex(nL) Spurs Live Workable!!! Spur short-circuit protection in wiring hub makes spurs Ex(nL) Zone 2 or Division 2 6 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Flame-Proof/Explosion-Proof Trunk and Spurs Power Conditioners Mountable in : a) Safe Areas, b) Zone 2 IIC T4 Haz Areas & c) Class 1, Div 2, Groups A-D Haz Areas Control System Ex(nA) Power Conditioners CONTROL ROOM Ex(nA) Trunk NOT Live Workable Junction Box: Ex(d) Megablock Certification Required: None Ex(d) Cable Glands Spurs NOT Live Workable FIELD Ex(d) Fieldbus Devices Zone 2 or Division 2 7 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Introducing Fieldbus Non-Incendive COncept FNICO is: - For Fieldbus in Zone 2 and Division 2 hazardous areas - Live-workable throughout without gas clearance, just like Intrinsic Safety - Based on FISCO, the Fieldbus Intrinsically Safe Concept - Easy to install, easy to document, easy to maintain - More field devices per segment than FISCO: lower cost FNICO brings the benefits of FISCO to Fieldbus installations in Zone 2 and Division 2 Hazardous Areas: - Simple safety assessment The safety analysis is a list of devices - No cable parameter calculations When the cable complies with basic requirements - Add new fieldbus devices without recalculating the safety analysis - As proven by test, longer cables with higher capacitance are permitted 9 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

More Devices on a FNICO Trunk Short-circuit current But FNICO has a key benefit, even compared with FISCO: - The reduced factor of safety means more current is available to the fieldbus trunk - So more fieldbus devices can be supported! 5A 2A CENELEC standard EN50 020 Curves apply to electrical apparatus with cadmium, zinc, magnesium or aluminium 1A Intrinsic Safety: I/1.5 Non-incendive: I/1.1 I 500mA 200mA IIA IIB 100mA 50mA IIC 20mA 10mA 10V 20V 50V 100V 200V 500V Open-circuit voltage V 10 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Typical Ex(n) Installation - FNICO FNICO Power Conditioners Mountable in : a) Safe Areas, b) Zone 2 IIC T4 Haz Areas & c) Class 1, Div 2, Groups A-D Haz Areas Control System Ex(nC) FNICO Power Conditioners CONTROL ROOM Ex(nL) Trunk Live Workable!!! FIELD Ex(nL) Spurs Live Workable!!! Ex(nL) or Ex(i) Fieldbus Devices Zone 2 or Division 2 11 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Typical Ex(i) Installation (Method #1 - Multibarrier) Power Conditioners Mountable in : a) Safe Areas, b) Zone 2 IIC T4 Haz Areas & c) Class 1, Div 2, Groups A-D Haz Areas Control System Ex(nA) Power Conditioners CONTROL ROOM Ex(nA) Trunk NOT Live Workable FIELD FieldConnex Certification Required: Ex(i) Ex(i) Spurs Live Workable!!! Ex(i) Fieldbus Devices (4 per FieldConnex) Zone 1 or Division 1 12 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Introducing Fieldbus Intrinsically-Safe COncept A new technical specification for Intrinsically Safe Fieldbus - takes advantage of recent experimental work on spark ignition - provides more current to IS trunk than earlier Entity model, and hence more field instruments - first simplification of explosion protection techniques for many years! 13 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

The Benefits of FISCO Formerly IS installations were done using IEC/EN60079-14 ( Entity ). This required: - calculation of cable parameters - comparison of safety descriptions - creation of descriptive system document Now IEC/TS 60079-27 FISCO Technical Specification - eliminates need to calculate cable parameters - reduces safety documentation to a list of devices - allows addition of devices without a review of safety documentation - as proven by test, allows longer cables with higher capacitance 14 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Typical Ex(i) Installation (Method #2 - FISCO) FISCO Power Conditioners Mountable in : a) Safe Areas, b) Zone 2 IIC T4 Haz Areas & c) Class 1, Div 2, Groups A-D Haz Areas Control System Ex(i) FISCO Power Conditioners CONTROL ROOM Ex(i) Trunk Live Workable!!! FIELD Ex(i) Spurs Live Workable!!! FISCO Fieldbus Devices Zone 1 or Division 1 16 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Comparison of Ex(i) Architectures PARAMETER Multibarrier (P&F) FISCO (MTL) System Design Rules Efficiency Cost Ease of Maintenance Hazardous Area Considerations Field Junction Box Material Non-standard voltage/current required at Trunk terminals of multibarrier Up to 250mA @ 16V for 4 devices (30% efficiency) One multibarrier per 4 devices, plus safe area power supply Complex, non-redundant electronics in field Trunk current is incendive: different maintenance practice for Trunk and Spurs No choice unless multiple variants (Ex(e) constraints) Same as safe area: minimum 9V @ Field Device Typically 84mA @ 9.4V for 4 devices (95% efficient) One repeater-power supply for up to 12 field devices (9122-IS, IIB) Electronics in control room: easier to service; benign environment Intrinsically safe throughout; live-workable Trunk and Spurs Material may be chosen to suit environment (e.g. stainless steel for pharmaceuticals) 17 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

How Many Field Devices in Hazardous Area? 80mA available Typically 3 or 4 Devices Zone 1 Division 1 MTL5053 : Entity, IIC/IIB Gas Group (Class 1, Group A & B) FISCO, IIC Gas Group (Class 1, Group A & B) 120mA available Typically 6 Devices FISCO, IIB Gas Group (Class 1, Group C & D) FNICO, IIC Gas Group (Class 1, Group A & B) 265mA available Typically 12 Devices 180mA available typically 9 devices Zone 2 Division 2 FNICO, IIB Gas Group (Class 1, Group C & D) 320mA available typically 16 devices Assumes 20mA per field device 18 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Installation Summary FEATURE Ex(nA) Ex(nC/nL) IIC FNICO Ex(nC/nL) IIB FNICO Ex(i) Entity Ex(i) IIC FISCO Ex(i) IIB FISCO Available Segment Power (ma) 350 180 320 80 120 265 Max. Number of Devices 17 9 16 4 6 12 Hazardous Area Classification Zone 2 Div 2 Field Device Certification Ex(n) Ex(i) Zone 2 Div 2 Ex(n) Ex(i) Zone 2 Div 2 Ex(n) Ex(i) Zone 1 Div 1 Zone 1 Div 1 Zone 1 Div 1 FISCO FISCO FISCO Live Workable Trunk No Yes Yes Yes Yes Yes Live Workable Spurs Yes (*) Yes Yes Yes Yes Yes Trunk Cable Length (No. Devices) 1,000m (1) 310m (9) 1,900m (1) 230m (16) 1,000m (1) 500m (6) 1,900m / 1 315m (12) Max. Spur Cable Length 30m 30m 30m 30m Redundant Power Conditioners Yes No No No No No Assumes 20mA per field device Distance VPSmax - VDEVmin(9V) # Devices * 20mA Loop /km (50 ) Hazardous Area Design Critical to Successful Fieldbus Installation 19 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Junction Box Terminations Power LED >9V SpurGuardTM option: - visual indication of fault - short-circuit protection Trunk Pluggable spur connectors Spur 2, 4, 8 and 10-drop versions Field cabinet - suitable for environment - site standard Terminator 21 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

One Last Point Surge Protection Surge Protection is often taken for granted and not specified! Surge Protection provides additional benefits through reduced Operating Expenses (OPEX) of the Fieldbus installation through - Higher System Integrity - Increased Reliability - Reduced Downtime MTL will provide 10-year warranty of the complete solution (Experion PKS Servers/Stations, Controllers, I/O Modules, FIMs, Power Conditioners, Instruments, etc.) when Surge Protection is used on both the Control Room and Field Instruments! - Implemented at ChevronTexaco Richmond, CA 22 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

Surge Protection Warranty (MTL) SURGE PROTECTION SURGE PROTECTION SURGE PROTECTION Fieldbus-based Field Instruments Fieldbus-based Field Instruments CONTROL/RACK ROOM (by DCS Vendor) FIELD (by EPC) Fieldbus Fieldbus Host Fieldbus Host Fieldbus Host Fieldbus Interfaces Host Interfaces Host Interfaces Interfaces Field Junction Box Control System Segment Power Segment Segment Power Segment Conditioners Power Conditioners Power Conditioners Conditioners Trunk Cables Spur Cables Field Junction Box 24VDC Bulk Power Supply SURGE PROTECTION Comms A/C Mains 23 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas

24 HONEYWELL - CONFIDENTIAL Fieldbus & Hazardous Areas