Floor standing boilers. RMG Mk.II RS Mk.II

Similar documents
RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

Sirius FS. Working towards a cleaner future

Sirius WH. Working towards a cleaner future

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Control Products & Systems OEM

Ideasandformsinevolution

Power X High Power Condensing Wall-Hung Boilers

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

ProCon Boiler Controller Commissioning Quick Reference Guide

Power X High Power Condensing Wall-Hung Boilers

Ciao Green Condensing Wall-Hung Boilers

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

GAS-FIRED FLOOR-STANDING BOILERS

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Forced draught gas burner

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Capri B Cast iron combination oil-fired boiler with water tank

SPECIFICATIONS - NIKE

CONDEXA PRO EXCELLENCE AND VERSATILITY

Easyfire Standalone biomass pellet boiler

Capri R CH only, oil-fired, cast iron boiler

The mechatronics of EVE 05

CAST IRON ATMOSPHERIC BOILERS

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

Rapid. Suspended Warm Air Heater. Caring for the environment!

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Wall hung combination

PCH/new Series. High performance, total flexibility

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

ENERGY TOP. Condensing boiler solutions

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

1 VICTRIX ZEUS Superior kw I features

Condensing, pre-mixed, wall-hung gas boilers with water tank

STILE BEAUTY AND TECHNOLOGY

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Heating Equipment. gas boilers RX GB. installation and servicing instructions

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Flue gas condensation...

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

ACCUMULATION OF EUROPEAN CLASS

PCH Heating Condensing Module for Air Handling and Roof Top Units

Light oil - kerosene burner

Control Products & Systems OEM

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

VICTRIX Superior kw Export VICTRIX Superior kw X Export

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

C Tahiti. condensing

Forced draught gas burner

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

FAMILY PRO SIMPLY THE BEST

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Sirius FS Working towards a cleaner future. Floor Standing Condensing Gas Boilers. Installation, Operation & Maintenance Manual

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

STREBEL S-CB + Cascade Kits

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

TWO STAGE HEAVY OIL BURNERS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

Tower Green HE Hybrid

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

The iqe Boiler Range. Combination and System T Boilers.

Prextherm Rsw High efficiency steel pressurised boilers

Light oil / kerosene burner

Biomass. Biomass solid fuel boiler range

1. Order and Auxiliaries

Hamworthy. Wessex Modumax. High Efficiency, Fully Modulating Boilers Condensing & Non Condensing, Pre-mix, Gas Fired. Outputs 100kW to 750kW

OVENS LINE. Pocket 4060 rack oven for bread and pastry

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Hamworthy. Purewell VariHeat

THE PERFECT CONDENSATION

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

DOMESTIC HOT WATER Follow operational sequence

ENG. Solo - Duetto BF TS/35 BF TS PR Solo - Duetto TS/35 TS PR (España)

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

INSTRUCTION FOR THE USER THC V E OIL BLU

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

FXLF-4. High Efficiency Water Heaters and Boilers

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

THE PERFECT CONDENSATION

User Manual for model

Transcription:

Floor standing boilers RMG Mk.II RS Mk.II

Caldaie a basamento RMG Mk.II - RS Mk.II The perfect solution for modular combinations RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed and manufactured in order to meet the demands of heating installations of middle and high output, thanks to the possible connection of several generators. The RMG Mk.II line of boilers has a range of 70 to 108 kw of output, while the RS Mk.II units are available in a range between 129 and 279 kw. These units can be equipped with different feeding gas types and comply to the EEC Gas Directive 90/396, EEC Electromagnetic Compatibility Directive 89/336, EEG Low Tension Directive 73/23 and the EEC Performance Directive 92/42.

Modular expansion In order to better distribute the thermal charges on large surfaces such as a house and/or a commercial or industrial estate, it is possible to make modular configurations with several RMG/RS Mk.II units. Up to two/three boilers in sequence complete with pumps/zone valves can be managed, as well as the preparation of an external D.H.W. tank. A modular installation of two RS Mk.II units The simplicity of the controls The control panel is simple and intuitive. The initial set up allows for the fitting of a climatic thermoregulator (RVA 43) that, in connection with an external sensor, will improve the performances and reduce the fuel seasonal consumption. 1 2 3 6 5 4 List of functions / devices 1 Main switch 2 Boiler thermostat 3 Thermometer 4 Smoke safety device 5 Safety thermostat 6 Lock-out button Safety and versatility The two-step combustion system of RMG Mk.II e RS Mk.II leads to a higher performance and reduces the thermal inertia. The RS Mk.II units are equipped with an additional gas valve. The small dimensions of the RMG Mk.II, together with the possible reversibility of the hydraulic and gas connections facilitate the installation, even when the room available is a key factor.

Modular power By means of the RVA43 (optional) climatic regulator, the performance of the product reach its best. The system guarantees a high seasonal efficiency, a reasonably low fuel consumption thanks to the adjustable flow temperature, high comfort and control of the required room temperature. The RVA 43 climatic regulator adopts the principle of a climatic thermoregulation connected to an external sensor. It is able to: Manage the system made of up to three appliances; Manage the continuous modulation of the system's power; Manage the sequenced turning on and off of the various units; Adapt itself to the heating requirements (by means of the external sensor); Adapt the system according to the external temperature; Automatically switch between summer/winter modes if temperatures rise above the set values; Activate and deactivate the domestic water system using a button on the regulator (if the system is connected to an external boiler); Manage the supply of the domestic water (if the system is connected to an external boiler) on a weekly basis; Priority activation of the production of domestic hot water (if the system is connected to an external boiler); Guarantee the diagnostic of any possible failure. 5 List of functions / devices 1 Setting of the room temperature 4 3 7 2 2 3 4 Setting to the selected parameter Parameter selection Display of readings, settings and operating status 6 1 5 Operating rate buttons 6 LED function key for manual operation 7 PC connection for diagnosis and repair A cast-iron soul Cast iron is an alloy whose properties remain unaltered throughout time and means reliability, long life and ease of maintenance. The particular shape of the cast-iron heat exchanger leads to a perfectly balanced combustion with very low gas exhaust emissions. These are the most remarkable results that have been achieved by Sime through more than thirty years of experience.

Technical data RMG Mk.II 70 Mk.II 80 Mk.II 90 Mk.II 100 Mk.II 110 Mk.II Heat output kw 49,1-70,1 56,0-78,7 63,0-90,0 69,9-98,6 74,7-107,9 kcal/h 42.200-60.300 48.200-67.700 54.200-77.400 60.100-84.800 64.200-92.800 Heat input kw 77,9 87,4 100,0 109,5 120,5 kcal/h 67.000 75.200 86.000 94.200 103.600 Efficiency at max. output % 90,1 90,0 90,0 89,9 89,5 Efficiency at 30% of the output % 87,1 87,2 87,4 87,5 86,4 Cast iron sections no. 8 9 10 11 12 Absorbed electrical power W 16 16 16 16 69 Water content litres 25 28 31 34 37 Maximum water head bar 4 4 4 4 4 Weight kg 238 266 294 322 350 Overall dimensions - Hydraulic connections P D 1000 195 G M Dimensions Model P mm D ø mm L mm A mm 70 Mk.II 645 180 840 415 80 Mk.II 645 180 940 415 90 Mk.II 645 200 1040 415 100 Mk.II 645 225 1140 415 110 Mk.II 670 250 1240 400 485 665 Connections 475 S L 65 R 75 A M C.H. flow 1 1 2 R C.H. return 1 1 2 G Gas 1 S Discharge 3/4 Technical and safety characteristics Automatic ignition by means of flame ionization Electric valve with double obturator, which in absence of flames, stops the gas flow Multifunctional climatic adjuster RVA43.222 for the management of single boilers and in sequence up to sixteen boilers Room temperature controller QAA 70 for the remote control of an area integrated with the climatic regulator RVA46.531 Boiler D.H.W. tank, zone temperature sensor QAZ 21 cable L. 2000 Two-steps combustion system allowing a higher performance and reducing the thermal inertia External temperature sensor QAC 31 for the activation of the automatic sliding of the heating temperature Temperature contact sensor QAD 21 for cascade flow/return and zone Combination of vertical storage tanks for sanitary hot water made in stainless steel with a capacity of 500/1000/2000 litres Multifunctional climatic regulator RVA46.531 for the management of single boilers or as area adjuster in installations with mixing valves or pumps Safety thermostat and thermometer for the control of the C.H. temperature Combination of smoke room with single scavenging flue for the disposition of two boilers RS Mk.II with the same potential RMG Mk.II Optional

Technical data RS Mk.II 129 Mk.II 151 Mk.II 172 Mk.II 194 Mk.II 215 Mk.II 237 Mk.II 258 Mk.II 279 Mk.II Heat output kw 129,0 150,6 172,2 193,7 215,2 236,5 257,8 279,1 kcal/h 110.900 129.500 148.100 166.600 185.000 203.400 221.700 240.000 Heat input kw 145,9 170,0 194,2 218,2 242,1 266,0 290,0 313,6 kcal/h 125.450 146.200 167.000 187.650 208.200 228.750 249.400 269.700 Efficiency at max. output % 88,4 88,6 88,7 88,8 88,9 88,9 88,9 89,0 Efficiency at 30% of the output % 86,7 86,9 87,1 87,3 87,5 87,6 87,7 87,8 Cast iron sections no. 7 8 9 10 11 12 13 14 Absorbed electrical power W 80 80 80 80 80 80 80 80 Maximum water head bar 5 5 5 5 5 5 5 5 Weight kg 542 612 682 757 829 904 974 1044 Overall dimensions - Hydraulic connections C L D P L1L D1D M 825 485 G 110 R 1365 S 140 Dimensions F Model L mm L1 mm P mm C mm D ømm D1 ømm F 129 Mk.II 810 2360 1110 730 250 400 315 151 Mk.II 920 2360 1110 730 250 400 315 172 Mk.II 1030 2360 1110 730 250 400 315 194 Mk.II 1145 2360 1140 760 300 450 345 215 Mk.II 1255 2360 1140 760 300 450 345 237 Mk.II 1370 2380 1190 810 350 500 395 258 Mk.II 1480 2380 1190 810 350 500 395 279 Mk.II 1580 2380 1190 810 350 500 395 880 Connections Z Opposed installation of two boilers with same output M C.H. flow 2 R C.H. return 2 G Gas 1 1 2 S Discharge 3/4 Technical and safety characteristics Second gas electro valve and pressure switch Automatic ignition by means of flame ionization Electric valve with double obturator, which in absence of flames, stops the gas flow Multifunctional climatic adjuster RVA43.222 for the management of single boilers and in sequence up to sixteen boilers Room temperature controller QAA 70 for the remote control of an area integrated with the climatic regulator RVA46.531 Boiler D.H.W. tank, zone temperature sensor QAZ 21 cable L. 2000 Two-step combustion system allowing a higher performance and reducing the thermal inertia External temperature sensor QAC 31 for the activation of the automatic sliding of the heating temperature Temperature contact sensor QAD 21 for cascade flow/return and zone Combination of vertical storage tanks for sanitary hot water made in stainless steel with a capacity of 500/1000/2000 litres Multifunctional climatic regulator RVA46.531 for the management of single boilers or as area adjuster in installations with mixing valves or pumps Safety thermostat and thermometer for the control of the C.H. temperature Combination of smoke room with single scavenging flue for the disposition of two boilers RS Mk.II with the same potential RS Mk.II Optional Fonderie SIME S.p.A. pursue a policy of continuing improvement in design and performance of our products. The right is therefore reserved to vary specifications without notice. cod. 3905302-04/2005 Fonderie Sime S.p.A Via Garbo, 27 37045 Legnago (Vr) Italy Tel. +39 0442 631111 Export Division Fax +39 0442 631293 www.sime.it