RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

Similar documents
Floor standing boilers. RMG Mk.II RS Mk.II

Sirius FS. Working towards a cleaner future

Sirius WH. Working towards a cleaner future

ProCon Boiler Controller Commissioning Quick Reference Guide

Power X High Power Condensing Wall-Hung Boilers

CAST IRON ATMOSPHERIC BOILERS

Power X High Power Condensing Wall-Hung Boilers

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

ENERGY TOP. Condensing boiler solutions

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Control Products & Systems OEM

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Ciao Green Condensing Wall-Hung Boilers

The mechatronics of EVE 05

Ideasandformsinevolution

SPECIFICATIONS - NIKE

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

1 VICTRIX ZEUS Superior kw I features

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

CONDEXA PRO EXCELLENCE AND VERSATILITY

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Flue gas condensation...

Capri B Cast iron combination oil-fired boiler with water tank

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

VICTRIX Superior kw Export VICTRIX Superior kw X Export

PCH/new Series. High performance, total flexibility

Rapid. Suspended Warm Air Heater. Caring for the environment!

Capri R CH only, oil-fired, cast iron boiler

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

STREBEL S-CB + Cascade Kits

Sirius FS Working towards a cleaner future. Floor Standing Condensing Gas Boilers. Installation, Operation & Maintenance Manual

Condensing, pre-mixed, wall-hung gas boilers with water tank

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Forced draught gas burner

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

STILE BEAUTY AND TECHNOLOGY

Hamworthy. Wessex Modumax. High Efficiency, Fully Modulating Boilers Condensing & Non Condensing, Pre-mix, Gas Fired. Outputs 100kW to 750kW

GAS-FIRED FLOOR-STANDING BOILERS

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Hamworthy. Purewell VariHeat

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

The iqe Boiler Range. Combination and System T Boilers.

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

DOMESTIC HOT WATER Follow operational sequence

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

C Tahiti. condensing

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

and sanitary hot water Catalogue 2009

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Quickheat 30 weather compensated boiler control

ACCUMULATION OF EUROPEAN CLASS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Light commercial products. High output boilers Cascade systems

Control Products & Systems OEM

ENVI Boiler Controller

Electronic Pellet Burner Controller NPBC-V3-1

PCH Heating Condensing Module for Air Handling and Roof Top Units

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

Biomass. Biomass solid fuel boiler range

Easyfire Standalone biomass pellet boiler

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Appliance and Controller Electrical Installation Guide.

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

1. Order and Auxiliaries

Electronic Pellet Burner Controller NPBC-V3M

THE PERFECT CONDENSATION

FAMILY PRO SIMPLY THE BEST

LOW NOx MODULATING GAS BURNERS

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Tower Green HE Hybrid

Rozp.UE2015/ kw kw

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Combined boiler. for solid fuel and pellets

ADI CD CONDENSING BOILER

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

Wall hung combination

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Your guide to. Biomass Heating Systems

Eco Angus Wood Pellet Boilers

ADI LT CONDENSING LOW TEMPERATURE BOILER

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Transcription:

Caldaie a basamento RMG Mk.II and RS Mk.II gas boilers are cast-iron made and are developed and manufactured in order to meet the demands of heating installations of middle and high output, thanks to the possible connection of several generators. The RMG Mk.II line of boilers has a range of 70 to 108 kw of output, while the RS Mk.II units are available in a range between 129 and 279 kw. These units can be equipped with different feeding gas types and comply to the EEC Gas Directive 90/39, EEC Electromagnetic Compatibility Directive 89/33, EEG Low Tension Directive 73/23 and the EEC Performance Directive 92/2.

Modular expansion In order to better distribute the thermal charges on large surfaces such as a house and/or a commercial or industrial estate, it is possible to make modular configurations with several RMG/RS Mk.II units. Up to two/three boilers in sequence complete with pumps/zone valves can be managed, as well as the preparation of an external D.H.W. tank. A modular installation of two RS Mk.II units The simplicity of the controls The control panel is simple and intuitive. The initial set up allows for the fitting of a climatic thermoregulator (RVA 3) that, in connection with an external sensor, will improve the performances and reduce the fuel seasonal consumption. 1 2 3 List of functions / devices 1 Main switch 2 Boiler thermostat 3 Thermometer Smoke safety device Safety thermostat Lock-out button Safety and versatility The two-step combustion system of RMG Mk.II and RS Mk.II leads to a higher performance and reduces the thermal inertia. The RS Mk.II units are equipped with an additional gas valve. The small dimensions of the RMG Mk.II, together with the possible reversibility of the hydraulic and gas connections facilitate the installation, even when the room available is a key factor.

Modular power By means of the RVA3 (optional) climatic regulator, the performance of the product reach its best. The system guarantees a high seasonal efficiency, a reasonably low fuel consumption thanks to the adjustable flow temperature, high comfort and control of the required room temperature. The RVA 3 climatic regulator adopts the principle of a climatic thermoregulation connected to an external sensor. It is able to: Manage the system made of up to three appliances; Manage the continuous modulation of the system's power; Manage the sequenced turning on and off of the various units; Adapt itself to the heating requirements (by means of the external sensor); Adapt the system according to the external temperature; Automatically switch between summer/winter modes if temperatures rise above the set values; Activate and deactivate the domestic water system using a button on the regulator (if the system is connected to an external boiler); Manage the supply of the domestic water (if the system is connected to an external boiler) on a weekly basis; Priority activation of the production of domestic hot water (if the system is connected to an external boiler); Guarantee the diagnostic of any possible failure. List of functions / devices 1 Setting of the room temperature 3 7 2 2 3 Setting to the selected parameter Parameter selection Display of readings, settings and operating status 1 Operating rate buttons LED function key for manual operation 7 PC connection for diagnosis and repair A cast-iron soul Cast iron is an alloy whose properties remain unaltered throughout time and means reliability, long life and ease of maintenance. The particular shape of the cast-iron heat exchanger leads to a perfectly balanced combustion with very low gas exhaust emissions. These are the most remarkable results that have been achieved by Sime through more than thirty years of experience.

Technical data RMG Mk.II 70 Mk.II 80 Mk.II 90 Mk.II 100 Mk.II 110 Mk.II Heat output kw 9,1-70,1,0-78,7 3,0-90,0 9,9-98, 7,7-107,9 kcal/h 2.200-0.300 8.200-7.700.200-77.00 0.100-8.800.200-92.800 Heat input kw 77,9 87, 100,0 109, 120, kcal/h 7.000 7.200 8.000 9.200 103.00 Efficiency at max. output % 90,1 90,0 90,0 89,9 89, Efficiency at 30% of the output % 87,1 87,2 87, 87, 8, Cast iron sections no. 8 9 10 11 12 Absorbed electrical power W 1 1 1 1 9 Water content litres 2 28 31 3 37 Maximum water head bar Weight kg 238 2 29 322 30 Overall dimensions - Hydraulic connections P D 1000 19 G M Dimensions Model P mm D ø mm L mm A mm 70 Mk.II 180 80 1 80 Mk.II 180 90 1 90 Mk.II 200 100 1 100 Mk.II 22 110 1 110 Mk.II 70 20 120 00 8 Connections 7 S L R 7 A M C.H. flow 1 1 2 R C.H. return 1 1 2 G Gas 1 S Discharge 3/ Technical and safety characteristics Automatic ignition by means of flame ionization Electric valve with double obturator, which in absence of flames, stops the gas flow Multifunctional climatic adjuster RVA 3.222 for the management of single boilers and in sequence up to sixteen boilers Room temperature controller QAA 70 for the remote control of an area integrated with the climatic regulator RVA.31 Boiler D.H.W. tank, zone temperature sensor QAZ 21 cable L. 2000 Two-steps combustion system allowing a higher performance and reducing the thermal inertia External temperature sensor QAC 31 for the activation of the automatic sliding of the heating temperature Temperature contact sensor QAD 21 for cascade flow/return and zone Combination of vertical storage tanks for sanitary hot water made in stainless steel with a capacity of 00/1000/2000 litres Multifunctional climatic regulator RVA.31 for the management of single boilers or as area adjuster in installations with mixing valves or pumps Safety thermostat and thermometer for the control of the C.H. temperature Combination of smoke room with single scavenging flue for the disposition of two boilers RS Mk.II with the same potential RMG Mk.II Optional