ATEX Safety Instructions. DYNHRT3MMSS Line Rider

Similar documents
Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Intrinsically Safe Transmitters, Option Code 2n

manual addendum DELPHI Ex

Supplementary Installation and Operating Instructions. Category II2G

Manual Power relay SR853

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Certification Supplement Manual

Certification Supplement Manual

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

IECEx Certificate of Conformity

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Information OUSAF21

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Certificate of Compliance

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Certification Supplement Manual

Certificate of Compliance

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Conductivity Electrode LRG Original Installation Instructions English

Technical Information OUSTF10

Transmitters/Sensors. OLCT Series

Technical Information OUSAF12

Certificate of Compliance

OPTIBAR DP 7060 Supplementary Instructions

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Technical Information OUSAF44

Technical Information OUSAF22

IECEx Certificate of Conformity

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

TRASCO ATEX Couplings

Certificate of Compliance

Manual Isolating Barrier D461 (Revision 05)

IECEx Certificate of Conformity

EU DECLARATION OF CONFORMITY

ANNEX GD-CERT-EX-EN SIT

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

Certificate of Compliance

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Certificate of Compliance

Manual Isolating Barrier D461R1 (Revision 01)

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Level Electrode NRG NRG Original Installation Instructions English

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Certificate of Compliance

IECEx Certificate of Conformity

1510 Side Mounted Level Switch

Intrinsically Safe or Explosionproof? Understanding the technology

Model 144H. Product Data Sheet , Rev DB February Content

ATEX Explained A brief Introduction

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

INTERNATIONAL STANDARD

UL HAZARDOUS LOCATIONS SERVICES

VSD AND SS DRIVING ATEX MOTORS February 2014

Translation of the assembly instructions with operating instructions and technical appendix

Certificate of Compliance

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Inductive slot sensor

INTERNATIONAL STANDARD

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

OPTIBAR P 1010/2010 C Supplementary instructions

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

MT5000 Guided Wave Radar Level Transmitter. State-of-the-art loop powered, 4-20 ma output guided wave radar transmitter for liquid level applications

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Instruction manual 640 Securiterre

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

NRG NRG NRG NRG

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Annubar Flowmeter Series

EEHA CERTIFICATION FPSO S FOR INTERNATIONAL OPERATIONS

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Certificate of Compliance

Declaration of conformity

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Certificate of Compliance

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

AUGUST 2016 CONTENTS:

Rosemount 702 Wireless Discrete Transmitter

Transcription:

DYNHRT3MMSS Line Rider ATEX Safety Instructions Load Systems International 2666 Boul du Park-Technologique Québec QC G1P 4S6 Canada www.loadsystems.com

SCOPE This Ex instruction manual must be read and used by qualified personnel during system design and installation of the. These instructions are provided as an addendum to the standard product manuals. Warning The HRT3MM Line rider may only be installed in Group IIC T4, -20ºC < Tamb < +75ºC Zone 2. The HRT3MM Transmitter must be operated within environmental limitations. The HRT3MM line rider must only be installed by qualified personnel in accordance with the relevant international installation standards SAFETY ANALYSIS In a system safety analysis, always check that the Hazardous Area / Hazardous location devices conform to the relevant standards and regulations governing the installation and safe use. INSTALLATION The HRT3MM is fully self-contained. Warning The HRT3MM must be installed such that there CANNOT be metal-to-metal impact. This may be accomplished by firmly fixing the HRT3MM to a structure using mounting feet. If the HRT3MM is to be used with a swing arm then measures MUST be put in place preventing the HRT3MM from impacting any metal structure at any time.

Swing Arm Metal-to-metal impact must be prevented NOTE: There are restrictions on the surface area of plastics installed in an Ex atmosphere. If pads or bumpers are to be employed it is the installers responsibility to ensure the local regulations are followed for a Zone 2 installation. Grounding techniques conforming to local regulations must be employed. CABLING The must only be used with an intrinsic safety barrier which has been evaluated for the given installation. All relevant installation guidelines must be followed.

SERVICE LIFE Warning The bearings have a rated life which varies with load according to the table below. Note that the service life hours vary widely with load for the HRT3MM line rider. The worst case limitation at full load is 145 hours of running time. The maximum line pull of the HRT3MM is 6 metric tonnes. This equates to a maximum center bearing load of 8.25 metric tonnes (there are two center sheave bearings). Thus the maximum possible load on each center sheave bearing is 8.1 kn. It is the owner/operator s responsibility to monitor use and ensure the bearings are inspected periodically and replaced when the end of their service life is reached. Contact LSI for bearing replacement parts and procedures.

Declaration of Conformity HRT3MM Declaration of Conformity in accordance with EN 45014 (ISO/IEC22) LSI-Robway Pty Limited Declares that: MODEL DESCRIPTION Tensiometer is in accordance with the following European Directives: 94/9/EC Equipment intended for use in potentially explosive atmospheres (ATEX) and have been designed and manufactured according to one or more following standards: EN 60079-0 EN 60079-11 ISO 9001:2008 EN13463-1 EN13463-5 ISO 281 Electrical apparatus for explosive gas atmospheres. Part 0: General Requirements Explosive atmospheres. Part 11: Equipment protection by intrinsic safety i Quality Management System Non-electrical equipment for use in potentially explosive atmospheres Basic Method and Requirements Non-electrical equipment for use in potentially explosive atmospheres Protection by Constructional Safety Roller Bearings Dynamic Load Ratings and Rating Life and are covered by: SAF0019 SAC011 Safety Analysis, Kelba Beam Cell, BARD1063 I/S barrier, CABBSHLD4CBL Simple Apparatus Assessment, Kelba Beam Cell HRT3MM, Ignition Hazard Assessment Report Jonathan P. Koval Hazardous Area Systems Manager

HRT3MM Declaration of Conformity Revision History Rev Description Approved A Initial Release J. Koval