Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Similar documents
Process Automation. Sensors and Systems: Level Sensors Level Detectors Overfill Prevention. Process Automation. Accuracy.

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

LS 300 LS 500. Technical Documentation. Level detector. Measuring transducer. Edition: Version: 7 Art. No.:

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

HYGROPHIL H process hygrometer

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Safety vacuum drying oven for flammable solvents

Terminal Automation Solutions

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Vacuum drying oven for non-flammable solvents

Ultrasonic Level Measurement nivopuls FDU 10 S

SITRANS T temperature transmitters A broad product family for every application. sitrans

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

Enraf Servo Gauge 854 XTG

Direct reading flowmeters type RM

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Thermostats. Innovative solutions for the toughest requirements

BINDER Scientific Product Catalog

Fill Point, Level Gauges, and Control Range

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

COMPACT FLAME CONTROLLER CFC 1000

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

GROUNDING MONITORING DEVICES AND SYSTEMS

Rosemount 2100 Series

MX RANGE PACKAGED STEAM BOILERS

COMPACT FLAME CONTROLLER CFC 2000

SEPARIX. Technical Documentation. SEPARIX-C/-T and SEPARIX-Control CT. Edition: Version: 5 Art. no.:

Building Services Brochure

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

WIO200 Water In Oil measuring instrument

Vibracon LVL-A* Level limit switch for liquids, compact design

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Accuracy by Design Products for the HVAC Professional

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Oxygen Sensing Solutions

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

THE SHAPE OF VACUUM UV SERIES

Alternative Fuels Applications

Using the Model 1500 Portable Chilled Mirror Hygrometer

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

FLAME AMPLIFIER MODULE 3001

Cleaning systems custom-made for all application ranges

HEATERS MOUNTED ON THREADED PLUG

Terminal Automation Solutions

COMPACT FLAME CONTROLLER CFC 100

OilMatic Pro / 230 V AC

polar zone components and systems for extreme temperatures

Thermostats. Innovative solutions for the toughest requirements

Industrial Strength Leak Detection

Gas cooler series TC-Standard+ X2

Alarm system For oil-water separator

Cleanroom Technology. Complete solutions for pharmacies.

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

designed for rail 5000 Series

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

OPERATING INSTRUCTIONS MAXIMAT LW CX COMPACT LEAKAGE SENSOR

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

HVAC Sensors Catalogue

Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE. What You Measure, We Manage

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Compressed Air Quality Audit ISO 8573

OPTISENS TUR 2000 Technical Datasheet

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

Snifter ATEX22 VERSION. User Manual. Distributor

SHAKING WATER BATHS ENGLISH

Constant climate chamber with ICH-compliant illumination

Industrial cooling systems LT

First Line of Safety: Farris Engineering

Pressure equalization by Venting

Pressure equalization by Venting

Hygro/hygrothermal transducers (hygrometric)

Heated Gas Sampling Probe PSG Basic

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Engineering Guideline. pac- Carriers Type Universal

Duct Temperature Sensors

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

More Precision. indusensor Linear inductive displacement sensors

Instruction Manual September 2010 SITRANS LVL200S

Autocalibration Systems for In Situ Oxygen Analyzers

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings

Capacitive Sensors with a body that is in excellent shape - The 26 Series

Modular Adsorption Dryers

ECOLOG Data logger series we prove it.

ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

Transcription:

Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable

FAFNIR Sensors and Systems Reliable, Universal Solutions for Your Level, Pressure and Temperature Measurement Requirements FAFNIR prides itself on providing the highest-quality measurement solutions to all its customers, regardless of application complexity and size. After trading for approximately 45 years, driving industry innovation, and listening to our customers and their requirements, we are pleased to present FAFNIR s German-made, high-precision level, pressure and temperature measurement devices for the petroleum, pharmaceutical, chemical and food industries to you, our customers. Why Buy FAFNIR Sensors and Systems? Reliability, Accuracy and Ease of Installation as Standard + + All our sensors are calibrated and stringently tested before they reach you, ensuring you receive only the best + + With FAFNIR s plug-and-play sensors, installation is quick and easy + + With pre-calibration, once installed, no adaptation to the liquid is required + + Our sensor lifespan and failure rate is second to none. FAFNIR s field-proven sensors are installed globally With 45 Years Engineering and Manufacturing Experience, Customer Service is Key + + Regardless of order complexity or size, we will find a solution for your business + + We have listened to the market and we know you need the full solution from one supplier + + We have extended our product portfolio to include pressure and temperature measurement so FAFNIR is at the forefront of your measurement needs + + The FAFNIR team are experts. We design, manufacture and calibrate all of our products to the highest quality

Introduction 3 Difficult Installation Conditions Are No Challenge for Fafnir. + + Designed to meet every requirement, our sensors fit the smallest to the largest openings + + Our extensive range of sensors means we will have a solution for you, even when other suppliers don t Extreme Process Conditions? + + Our sensors are proven in temperatures of up to 450 C or with up to 200 bar of pressure + + With a response time of less than 0.2 s and information regarding the filling levels with an accuracy of ±0.3 mm, you have constant visibility of your liquid stock + + Reliability assured in corrosive, toxic and viscous substances Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Point Level Switch and Overfill Prevention Protect Your Most Valuable Assets with the LS 300/LS 500 Point Level and Overfill Solution With the FAFNIR thermal limit switch with ATEX approval, your business and valuable liquids assets are protected. Our solution comprises a sensor which sits inside the tank and a transducer which manages the output relay. For polluting, corrosive and expensive liquids, the LS 300/LS 500 certified as overfill prevention device is an indispensable component for environmental and business protection. Why Choose LS 300/LS 500? Quick and Precise + + Easy installation with a 2-wire terminal to the transducer, fitted independent of polarity + + The overfill sensor requires no maintenance after installation; no hidden costs + + No on-site calibration required Dependable + + Full and empty notifications in all containers: storage tanks, underground and above-ground tanks, IBCs, tank wagons, vats, bottles and retention ponds + + Proven: tens of thousands of installations across Europe + + Self-testing sensors + + The overfill prevention device fulfils the requirements of the German Water Resources Act (WHG) + + Qualified for SIL2 applications Durable + + With no moving parts, the LS 300 and LS 500 boast excellent life expectancy and leading reliability + + Space-saving, robust and corrosion-free design + + Adaptable, flexible; as the intermediate flange which is only 3mm in diameter or with DN 200 flange, we have a solution for almost any application Tried and Tested + + Any tank type and size + + Sumps + + Pilot plant and prototype systems + + Tank arm during filling

LS 300/LS 500 17 LS 300 Sensor Technical Data Process temperature Standard: -25 C to +50 C High temperature: -25 C to +80 C Low temperature: -40 C to +50 C (pressure-free) Process pressure Immersion switch delay 0 bar to 25 bar < 2 s Level Sensors Heating-up time at -20 C < 2 min., at +60 C < 15 s Probe tube Wetted parts Stainless steel 316 Ti; Hastelloy C4, C22; Hastelloy B2, B3 Level Switches LS 500 Tranducer Technical Data LS 500 (wall housing) LS 500 19 Name LS 500 LS 500 19 LS 500 19 Duo Overfill Prevention Number of connections 1 Level sensor 1 Level sensor 2 Level sensor Auxiliary power 230 V AC ; 115 V AC ; V DC ; V AC 230 V AC ; 115 V AC ; V DC ; V AC 230 V AC ; 115 V AC ; V DC ; V AC Power input max. 5 W max. 5 W max. 10 W Ambient temperature -25 C to +50 C -25 C to +50 C -25 C to +50 C Casing protection class IP40 Dimensions H 150 x W 75 x D 110 [mm] Euroboard 160 x 100; 7 TE Euroboard 160 x 100; 7 TE Outputs Potential-free changeover contact: AC: U 250 V, I 4 A, P 100 VA DC: U 250 V, I 250 ma, P 50 W Potential-free changeover contact: AC: U 250 V, I 4 A, P 100 VA DC: U 250 V, I 250 ma, P 50 W Potential-free changeover contact: AC: U 250 V, I 4 A, P 100 VA DC: U 250 V, I 250 ma, P 50 W Output 1 Response to level sensor 1 Response to level sensor 1 Response to level sensor 1 Output 2 Optional: Option Z (response to level sensor 1) Option S (dysfunction) Optional: Option Z (response to level sensor 1) Option S (dysfunction) Response to level sensor 2 Options Approval for LPG Approval in accordance with AK5 Approval in accordance with AK5 For order code and technical documentation visit: www.fafnir.com/ls300/ls500 Pressure Sensors Temperature Sensors

Standard Versions Our Standard sensors suitable for most process connections, with variable screw-in unit or welded flange. For mobile applications with Plug, for very critical applications also with pneumatic test connection, to test the sensor not only electronically, but the real physical measurement principal. For vehicles, tank containers and tanks which are moved frequently, we also offer our limit switches with a plug. This allows a quick coupling and decoupling of the limit switch. 90 46 Ø 88 115 Ø 88 18 155 42 100 35 SW 22 Sensor length 12 G 3/ 8 Threshold length Ø Threshold length Ø Name LS 300 Standard LS 300 FSU LS 300 FSPU-Steck Connection housing Brass chrome-plated Stainless steel Stainless steel 316 Cable terminal Cable gland Cable gland Standaufnehmer DD28 Connector Probe tube 10 mm/sleeve 12 mm LS mm300 FSU mm Sonderausführung Minimal gland G 3 8 G 1 G 1 Minimal flange DN 15 DN 25 DN 25

LS 300/LS 500 19 Plugged and DUO Version For all applications where you need more than one point level for your process control or an additional overfill prevention. For vehicles, tank containers, and tanks which are moved frequently, we also offer our limit switches with a plug. This allows a quick coupling and decoupling of the limit switch. 55 (SW 51) 90 175 Ø 88 125 Level Sensors Threshold length 2 11 35 Sensor length 1 Name LS 300 EU Duo LS 300 ESU Duo LS 300 FU Duo Steck Connection housing Brass chrome-plated Stainless steel 316 Stainless steel 316 Threshold length 1 Threshold length 2 14 Threshold length 1 Threshold length 2 Level Switches Cable terminal Cable gland Cable gland DD28 Connector Probe tube 2 x 10 mm/sleeve 12 mm 3 x 10 mm/sleeve 12 mm 2 x 10 mm Minimal gland G 1 G 1 G 1 Minimal flange DN 25 DN 25 DN 25 62 55 (SW51) Overfill Prevention Sensor length 1 Sensor length 2 43 172 14 40 40 Name LS 300 E Duo LS 300 EXU Steck Duo LS 300 Ex Steck (Mono/Duo) Threshold length 1 Threshold length 2 40 Threshold length 1 Threshold length 2 50 3 Pressure Sensors Connection housing Stainless steel 316 Stainless steel 316 Stainless steel 316 Cable terminal Cable gland DD28 Connector M12 Connector Probe tube 12 mm 12 mm 12 mm Minimal gland G½ (variable) G 3 8 G 3 8 Temperature Sensors

62 Process Auromation Edition 08.13 Technical Changes Reserved Special Design We offer a variety of special designs that are designed where space is limited or installation conditions are difficult and challenging. Here are some examples from our portfolio of special designs challenge us! 3 m Cable 29 300 500 mm ca. 10 Ø 21.3 40 50 Ø 6 SW 14 R ¼ Sensor length Ø 3 ca. 31 18 Threshold length 2 86 Name LS 300 Compact LS 300 B LS 300 FUX Connection housing Stainless steel 316 Stainless steel 316 LS 300 Stainless mit Wellschlauch steel 316 Cable terminal Cable is moulded and fixed Cable LS 300is moulded and fixed in Sonderausführung Ø3 Cable is moulded and fixed Probe tube 6 mm 3 mm 10 mm/sleeve 12 mm Minimal gland R ¼ 0 Ø 55 70 mm Threshold length 20 32 41 145 42 55 60 1 Ø 6 28 Sensor lenght Name LS 300 Intermediate Flange LS 300 Interstitial LS 300 Special Connection housing Brass chrome-plated Stainless steel 316 Stainless steel 316 Cable terminal Cable gland Cable is moulded and fixed Cable is moulded and fixed Probe tube 10 mm/sleeve 12 mm 6 mm/12 mm 10 mm Minimal flange DN 50

FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Phone: +49/40/39 82 07-0 Fax: +49/40/390 63 39 E-mail: info@fafnir.com Internet: www.fafnir.com Sensors & Systems Worldwide: www.fafnir.com