FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Similar documents
UL Listings & FM Approvals Their Impact on Fire Sprinkler System Performance/Design

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

The Worldwide Use of Fire Sprinklers

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Making sense of risk Risk engineering. Metalworking operations

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

FM Approval Standard For Cavity Walls And Rainscreens

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

The FM Global Research Campus

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

WATER MIST SYSTEMS. Table of Contents

The requirements of BS Watermist Fire System standard and how to demonstrate compliance

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

The Science Behind Water Mist Protection of Typical Building Hazards

Performance Based Fire Protection With Water Mist

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

Fire Protection for Printing Machines with High Pressure Water Mist

Watermist Fire Protection of Plant Rooms

esfr pendent sprinkler vk510 (k25.2)

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Setting the Standard in Third-party Certification

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

An Overview of Extinguishing Systems for Computer Equipment

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

VELMIST. System Mgły Wodnej Niskociśnieniowej

TECHNICAL DATA NOTICE

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

INSTALLATION & SERVICE MANUAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Chapter 10: Laboratory Equipment

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

TECHNICAL DATA OBSOLETE

CO 2 EXTINGUISHING SYSTEMS

CO2 COCO GAS FLOODING SYSTEM

Non-Storage / Special Protection / Storage Sprinklers

FIRE SUPPRESSION SYSTEM

Water Mist Fire Suppression

MORE THAN JUST FIRE PROTECTION

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

(h) Pesticide Application.

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

MORE THAN JUST FIRE PROTECTION

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

GASEOUS HYDROGEN SYSTEMS

Watermist nozzle issues and test methods

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

Fixed fire protection solutions

Managing Fire Protection System Impairment

Fire Safety Compliance

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers


High Ceiling Protection

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

Explosion Protection Engineering Principles

DETECT-A-FIRE Heat Detectors

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

Model 3300 Technical Support and Installation Manual

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

SUPPRESSION SALES I INSTALLATION I SERVICE

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

Building Services Brochure

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

micromatic standard response stainless steel sprinklers

Above Ground Fuel Tank Requirements

Universal Fire Tube Boiler Wall Mount Models

Safety Practices Fire Protection Equipment Cold Weather

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

OPERATION & MAINTENANCE MANUAL RHS680

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Portable Fire Extinguishers

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

Transcription:

FM Approvals & Water Mist Systems Paul Bardsley Engineer, FM Approvals

Presentation Outline Introduction to FM Global Introduction to FM Approvals FM 5560 - Water Mist Systems

Who are FM Global? The largest industrial and commercial insurance company in the world. $5+ billion in annual premiums $6+ billion in reserves No outstanding debt

FM Global An Overview Mutual ownership company Financially very strong (top 500 of Fortune 1000) Possess significant underwriting expertise Integrate engineering & insurance underwriting A genuine belief that all loss is preventable Possess an extensive global client base Global bet on FM Approvals engineering

FM Global Clients

FM Global Clients

FM Global Network Over 110 Countries Represented Over 133,000 insured locations 1871 Engineers 60,000 Annual Visits

Presentation Outline Introduction to FM Global Introduction to FM Approvals FM 5560 - Water Mist Systems

Introduction to FM Approvals Member of the FM Global Group Research Engineering

Mission Statement FM Approvals approves and certifies products and services with unique focus on: Objectively testing property loss prevention products and services and certifying those that meet rigorous loss prevention standards; Encouraging the development and use of Approved products and services that improve and advance property loss prevention practices.

FM Approvals and Risk Put another way FM Approvals conducts tests on property loss prevention products and services, the requirements that are applied are described in rigorous loss prevention standards which have been written by FM Approvals, the requirements in the standards are established from data and evidence collected through the research activities of FM Global.

FM Approvals and Risk An FM Approved product has achieved certain minimum levels of performance against a defined series of requirements. FM Approved products are the building blocks that can be used by FM Global and others to ensure loss prevention. Once the risk has been identified and fully understood, FM Approved products can be used, together with the appropriate installation standards to protect property.

The importance of research? What you are about to see is a FM Global research project looking at how much water is needed to control and extinguish a fire in a rack storage system of cardboard boxes containing expanded plastic food trays. You will see a fire introduced in the middle of the boxes and once the temperature at the ceiling level has achieved the required trigger temperature, water heads will be released at a known delivery rate.

Test Arrangement Watch the colour of the smoke drawn into the 20 Mega Watt Calorimeter. The fire will trigger the ceiling mounted extinguishing system which will deliver a constant 20 litres per minute per square metre. There are 24 x1m 3 boxes, arranged in the racking in two rows.

The water that was delivered was not enough to control or extinguish the fire. With this arrangement, there is a very high probability that the building and contents would have been destroyed. Can FM Approvals certify anything? No!

What can Approvals do? After hundreds of these tests, run with different configurations and arrangements, the research tests will have established how much water is required to control and to extinguish the fire. When used with the correct installation standards, the combined effect of the FM Approved product and FM Global s research knowledge, the property & commodity is protected.

FM Approvals History In June 1897, the Inspection Department of the Associated Factory Mutual Fire Insurance Companies Approved its first Electrical Fittings.

FM Approvals in Europe Notified Body under Construction Products Directive EOTA member for innovative CPD products. Notified Body under the ATEX Directive IECEx Certification Body UKAS Accredited Certification Body Member of Standards Committees & Industry Groups Undertaking FM Approval projects for US, Canadian, European & International Markets

FM Approvals Laboratory A look at the history of FM Approvals Test Laboratory.

Everett Testing Facility 1932

Norwood Test Facility 1947

W. Glocester Test Center 1967 Hydraulics 1992 Test Center 1967

New Research Campus 2003 Nat Haz Labs Large Fire Lab Hydraulics Labs Electrical Labs Research Labs Approvals Labs Offices

Hydraulics Laboratory

Hydraulics Laboratory

Hydraulics Laboratory

Water Mist Test

Sprinkler Flow Test

2004 FM Approvals Offices Norwood, MA W. Glocester, RI

FM Approvals International Windsor (2006) Beijing (2005) Shanghai (2007) Hong Kong (2007) Singapore (2006)

FM Approvals Hydraulics Products Fire pumps, Fire pump controllers, Diesel engine fire pump drivers, Sprinkler system components & extinguishing systems, Water mist systems.

FM Approvals Offering in Europe FM APPROVED 1725

Our Approval is different. We have a common interest in the performance of the Water Mist System This is what makes our Approval unique in the marketplace.

Presentation Outline Introduction to FM Global Introduction to FM Approvals FM 5560 - Water Mist Systems

FM Standard 5560: Water Mist Systems Defines the criteria for water mist system performance and test requirements for the FM Approval of land based systems. When installed in accordance with the recommendations described in FM Global Data Sheets will provide a Highly Protected Risk. Will be a truly living document which will be refined and expanded as needed for new applications of occupancy protection and for new water mist technology.

FM Standard 5560: Water Mist Systems FM Global Property Loss Prevention Data Sheet 4-2 provides evaluation and installation criteria for FM Approved Water Mist Systems.

FM Standard 5560: Water Mist Systems FM Approval requires successful compliance of the overall system operation and reliability against the requirements of FM Standard 5560 including General Requirements, Performance Requirements and Operational Requirements.

FM Standard 5560: Water Mist Systems FM Standard 5560 includes specific requirements for the components that make up the Water Mist System including Nozzles; Valves; Gas storage Cylinders; Detection Devices; Fittings & Piping; Hoses; Pneumatic Components; Switches; Tanks and Pumps.

FM Standard 5560: Water Mist Systems FM Standard 5560 also examines the performance of the system with respect to Verification of Hydraulic Calculations; Design, Installation, Operation and Maintenance Manuals; System Acceptance and Commissioning Documents and Fire Test Performance.

FM Standard 5560: Water Mist Systems Occupancy Protection Applications 1. Machinery Spaces & Special Hazard Machinery Spaces 2. Protection of Combustion Turbines 3. Light Hazard Occupancies 4. Protection of Wet Benches and Other Similar Processing Equipment 5. Local Application 6. Industrial Oil Cookers 7. Protection of Computer Room Sub Floors

FM Standard 5560: Water Mist Systems 1. Machinery & Special Hazard Machinery Spaces Machinery Spaces: Rooms with machinery using fuel or lubrication fluids with volatiles less than or equal to light diesel Special Hazard Machinery Spaces: Rooms with machinery using fuel or lubrication fluids with volatiles less than or equal to Heptane & Storage of less than 110 gallons of flammable liquids

FM Standard 5560: Water Mist Systems 1. Machinery & Special Hazard Machinery Spaces Fire Test Protocol Test protocol is dependent upon the volume of the enclosure; Combination of shielded and unshielded spray and pool fires up to 6MW in size; Conducted with machinery mockup in place and Spay cooling (no fire) test to assess for casing warp

FM Standard 5560: Water Mist Systems 2. Protection of Combustion Turbines Total Flooding Application Prevent and limit damage from fires internal and external to the turbine

FM Standard 5560: Water Mist Systems 2. Protection of Combustion Turbines Fire Test Protocol Test protocol is dependent upon the volume of the enclosure; Combination of shielded and unshielded spray and pool fires; Conducted with combustion turbine mockup in place and Spay cooling (no fire) test to assess for casing warp

FM Standard 5560: Water Mist Systems 3. Light Hazard Occupancies Non-storage and nonmanufacturing areas: Inappropriate for ordinary hazard occupancies Limited Ceiling heights, Water supply conditions & room size.

FM Standard 5560: Water Mist Systems 3. Light Hazard Occupancies Fire Test Protocol Restricted & Unrestricted Ceiling Height Approval FM Approved quick response nozzles must be used. Nozzles are set at manufacture's maximum spacing All fire tests conducted for 10 minutes after the activation of the first nozzle and any remaining fire shall be extinguished manually

Thermal images of Light Hazard Small Compartment fire (first) & Large Compartment fire (second).

FM Standard 5560: Water Mist Systems 4. Wet Benches & Other Similar Equipment Equipment which consist of ventilated and unventilated compartments, spin rinse dryers, alcohol vapor dryers, chemical and mechanical polishing tools, and step and repeat exposure systems

FM Standard 5560: Water Mist Systems 4. Wet Benches & Other Similar Equipment Fire Test Protocol Specific FM Approvals simulated clean room and wet bench mockup Water mist system installed as specified by manufacturer Air flow of the open face wet bench shall be the maximum specified by the manufacturer Subsurface and working surface polypropylene and flammable liquid pool fires

FM Standard 5560: Water Mist Systems 5. Local Application Protection of Special Hazards and Equipment: Paper machines and pulp dryers, Dip tanks & coaters, Belt Conveyers, Waste solvent recovery, Mechanical refrigeration.

FM Standard 5560: Water Mist Systems 5. Local Application Fire Test Protocol Seven test fire scenarios: Square diesel pool; channel diesel pool; heptane spray; diesel spray and pool; obstructed pool; offset pool & diesel spray with external ignition source Suitable automatic interlocks are required as part of overall system FM Approval, i.e., electrical system shutdown, fuel supply shutoff and ventilation shutdown.

FM Standard 5560: Water Mist Systems 6. Industrial Oil Cookers Non-Insulated conveyor fryers & batch kettles where the main hazard is overheating of oil to Actual Ignition Temperature (AIT)

FM Standard 5560: Water Mist Systems 6. Industrial Oil Cookers Fire Test Protocol Mock-up size determined from manufacturers specifications Open flames extinguished within one minute from start of discharge Water mist cannot cause thermal damage to cooker

FM Standard 5560: Water Mist Systems 7. Computer Room Sub Floors Protection of mainframe electronic computer systems and major equipment or process control computer systems located in the sub-floor

FM Standard 5560: Water Mist Systems 7. Computer Room Sub Floors Fire Test Protocol Three type of Fire Test Conducted at maximum nozzle spacing Water shall be supplied for at least 10 minutes

FM Standard 5560: Water Mist Systems General Examination & Performance Tests Seat Leakage Hydrostatic Strength Operating Pressure Durability Cycling Extreme Temperatures Operation Salt Spray Corrosion (Residue Build-Up) Vibration Resistance Valve Locking/Supervision Ability Friction Loss Determination Seals and Gaskets

FM Standard 5560: Water Mist Systems Water Mist Nozzle Tests Assembly Load/Frame Strength Strength of Heat Responsive Element Leakage Hydrostatic Strength 30-Day Leakage Water Hammer Operating Temperature (Liquid Bath) Air Bath Hang-Up of Operating Parts Strength of Deflector (Flow Endurance) Vacuum High Ambient Temperature Exposure (90 Day Test) Thermal Shock (Glass Bulb Nozzles Only) Discharge Coefficient, K-Factor Moist Air Corrosion - Salt Spray Corrosion - Stress Cracking Corrosion - Carbon Dioxide-Sulfur Dioxide Corrosion - Hydrogen Sulfide Vibration Rough Use and Abuse High Temperature Exposure Freezing Minimum Operating Pressure Process Residue Conductivity (C-Factor) Sensitivity - Response Time Index (RTI) Sensitivity (Recessed, Flush, and Concealed Types) Sensitivity (Air Oven) Water Mist Discharge Characteristics Impingement Protective Caps

FM Standard 5560: Water Mist Systems Other Performance Requirements and Examinations Complete System Documentation Review Hydraulic Calculations Method Installation, Operation and Maintenance Manual Manufacturing and Production Tests Demonstrated Quality Control Program Facilities and Procedures Audit (Quality Assurance) System Acceptance and Commissioning Installation Inspections by FM Global Field Engineers with feedback for continuous improvements

For more information contact. FM Approvals at: 1 Windsor Dials, Windsor, Berkshire, UK, SL4 1RS. Tel: +44 (0) 1753 750 000 Fax: +44 (0) 1753 868 700 E-mail: cpd@fmapprovals.com Website: www.fmapprovals.com

FM Approvals Ltd Thank You Believing that all losses are preventable