Quality Underfloor Heating

Similar documents
DOMOTHERM CLASSIC TWIN/S MAT

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

Anti frost. Snow Melting USA 2012 USA 2014

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

Underwood Heater Installation Manual

Toll Free:

F1202 TRACE HEATING. Road & Ramp

Electric Warm-Stretch under floor heating

The diagram shows the inside of an incorrectly wired three-pin plug. What two changes need to be made so that the plug is wired correctly?

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Installation Instruction Devidry - for installation with Devidry Pro Kit

amuheat Cable Mat floor heating systems Installation Manual CM02-12

Underfloor Heating Mat Installation Manual

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

Undertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

First Trace Heating Product Details

Underlaminate Foil Heater

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

ComfortTile Floor Heating Systems

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Underfloor Heating Cable Installation Manual

Installation Instruction

electric floor heating Heating mats Heating cables Temperature controllers

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

electric floor heating Heating mats Heating cables Temperature controllers

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand

emat Pro 100/150/200 Installation Manual

It s easy to install It s easy on the pocket It s easier on the environment

Uponor Comfort E AL-Foil Mat

Rhyno. Woven Polypropylene Geotextiles. Geosynthetics Limited

WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR!

UNDERWOOD HEATING SYSTEM

ELEKTRA RadiantFloor Heating

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

Woven Polypropylene Geotextiles

Silicone Heaters and heating foils

AKOCable Heating Cable Solutions Electrical Tracing

Installation Guide For your AHT Underfloor Heating System

HEATING USER GUIDE. Philex Support Line: Monday to Friday 9.00am to 5.00pm (Local rate - UK only)

HEATING BLANKETS BFVIBC

AKOCABLE Heating Cable Solutions Electrical Tracing

LARDER Instruction booklet

Heating Mats and Jackets. innovations in heat tracing

Heating Tapes/Mats HEATING TAPES HEATING CORDS HEATING MATS DRUM HEATERS GREAT FOR HEATING SMALL TUBES! MOISTURE RESISTANT!

Kettle v1.2. Models: SK (all models) Helpline:

Special Provision No. 683S28 December 2017

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

Electric Under Floor Heating

Single-side powered heating cables

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Floor Heating & Heated Towel Rails Product Catalogue

TT3000 and TT5000 Series

Click & Plug Floor Heating. Installation instruction Devidry Kit

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY

RFM Series RFM-ISR Barrier. Installation Manual

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

Guide to Condition Reports for Domestic Electrical Installations

Classic Mats Installation Manual

FIRE RESISTANT CABLES FP300

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

Steam Mop Instructions for Use

ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual

Oil Panel Heater Instructions for Use

Heating Cables and Tapes. Technology. Constant wattage tapes

Overview Frost Heave Prevention for Freezer floors on ground.

Infrared heater - Item Description. Print

ENHANCED FIRE PERFORMANCE CABLE

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

Half Inch Round LED Rope Light

Union County Vocational - Technical Schools Scotch Plains, New Jersey

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

Installation, Operation and Maintenance Manual

High temperature air-to-water heat pumps

GENERAL SPECIFICATION ELECTRICAL

electric floor heating for everyone Heating mats Heating cables Temperature controllers

CI/SfB (16)(17) Common Arrangement D11 Uniclass L1411/ L132/ L6634. Woven Polypropylene Geotextiles.

Heating Mats. Single-side power supply Double-side power supply

Domestic Hot Water Application manual

LC2200 Level Controller Installation and Maintenance Instructions

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier

ALARMLINE ANALOGUE Linear Heat Detection System

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

HEAT GUN KIT HG 2000K

Guide to condition reports for domestic electrical installations.

A guide. Part 1: Code of practice for system design, installation, commissioning and maintenance. by T.L. Journeaux

SOLARLOK Interconnection System Installation Manual

High Performance LSZH Fire Resistant Cable

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

LIFETIME. INSTALLATION MANUAL efoil WARRANTY

L J Visit to learn about the Danfoss Installer Certification program. Dual Self-Adhesive Mats. Installs in minutes!

Photovoltaic Cables EN H1Z2Z2-K

ATC Electric Under Floor Heating

Transcription:

Quality Underfloor Heating from The Floor Warming Company 1 Quality Underfloor Heating

Quality underfloor heating from The Floor Warming Company Q. Why is our underfloor heating so much better than competitors? A. Quite simply the underfloor heating system we supply has been designed to comply with the following - The Electromagnetic Compatibility Directive 89/336/EEC IEC 60335-1:2002 Household and similar electrical appliances Safety part 2 96:2002 and IEC 60800 IEC 60335-3-96. 2002 - Requirements for flexible sheet heating elements for room heating. EN 55014 Electromagnetic Compatibility EN50366 Electromagnetic Fields Methods for evaluation and measurement (EMF) 2 Quality Underfloor Heating

Every aspect of our heating is better starting with the label To comply with IEC 60335-2-96 and IEC 60800, the following information should be included on every UFH product Rated Voltage Symbol for nature of supply Rated power input in Watts Name, trademark or identification mark of the manufacturer Model or reference type IP number - safety rating for use near water 4401 FLOOR WARMING ELEMENT Code:52030 TYPE : FW M 2 S 1-570 Model : PV TWIN S BLACK EL STR ART.No. : 4401 570 435 230V ~ 50Hz IPX7 Relaxed W/m 2 : 200 Size : 0.44 x 25.00 = 11.00m 2 W/Unit : 2200 Ohm/Unit : 23 +10/-5% Max. operating temp 80ºC 4401 FLOOR WARMING ELEMENT TYPE : PV TWIN S BLACK EL STR ART.No. : 4401 570 427 230V ~ 50Hz W/m 2 : 200 W/UNIT : 350 SIZE : 0.44 x 4.00 = 1.75m 2 Max. operating temp 80ºC 3 Quality Underfloor Heating

The Connection Cable The construction of the cold/connection cables is very important, BS 7671 522-65, states that cables installed less than 50mm deep into a floor should be covered with a protective conductor (trunking or capping) unless the cable is of concentric construction (earth braiding wrapped around the cable) and class II (double insulated). As shown the cold leads on our systems are both Class II and are of co-axial construction this means they do not require mechanical protection in the floor or wall. Build up of Supply Lead Domoteck: Phase and Neutral with double insulation with tin coated copper braiding + PVC jacket. Ground Phase Neutral 4 Quality Underfloor Heating

The Connection between the Cold Lead and the Heating Cable Domoteck Connection Cable Connection of Supply Lead and Resistance Wire Domoteck: Most competitors use a single tube with the hearing cable and flex in the same tube which is just 5mms long. We use 2 tubes of 10mm length to compensate for different Heating wire Supply lead 3 layers of shrink tube 3 2 1 Last shrink tube long enough to cover the whole connection + extra protection against water penetration (shrink tube with glue) 5 Quality Underfloor Heating

Typical competitor cold lead connections Competitors: Last shrink tube very short will have different connection thickness due to not shifting of the connection Instead of shrink tube over the connection there is a very high temperature during injection Heating wire Supply lead 1 metallic tube (2 wires with different thickness) the metallic tube 5mm length for each type of wire inserted 1 layer of insulation Connection is not shifted Shrink tube 6 Quality Underfloor Heating

The result...this happened on a mat we bought from a very large DIY chain and a cable we bought from a large tile retailer. 7 Quality Underfloor Heating

The heating cable Domoteck s heating cable has been constructed to meet Class II* standards. *Class II Equipment in which protection against electric shock, does not rely on basic insulation only, but in which additional safety precautions such as supplementary insulation are provided. 8 Quality Underfloor Heating

A kevlar core gives the cable high tensile strength The DIY system failed the tensile test at 185N, all Domoteck products are tested to 350N. Typical Competitor Heating Cable Domoteck s heating elements are 6% longer than the cable length so the cable can be bent without damage occurring. 2 layers of insulation make it truly Class II with earth braiding, then the final layer of PVC designed to protect the cable from chemicals in the tile adhesive. Our cables have been built to withstand more than 4000 volts. We would be very suprised if other cables can withstand any where near this amount. This cable is clearly constructed with only one layer of insulation and an earth They use the outer layer as the second layer of insulation and we feel this fails the quality standards required. 9 Quality Underfloor Heating

The Mats Typical competitor mat Other manufacturers produce systems which comprise cables glued or crudely taped onto waterproof plastic/fibreglass, this has the disadvantage of causing air bubbles between the tile adhesive and the subfloor, this can prevent the tiles from bonding with the subfloor. See picture below to see the irregular spacing of the cables and the mat turned up at the end. This is a good example of the poor quality of mat you could easily end up with. Domoteck is the only manufacturer in the world that produces mats where the heating cable is actually interwoven into a textile mat. This fabric acts like a sponge soaking up the adhesive and allowing the tiles to bond perfectly with the subfloor creating an unparalleled bond between the subfloor and the tiles. High street brand competitor 10 Quality Underfloor Heating

A Comparison Between Fabric and Fibreglass Mats The perspex tile on the left shows the installation of a fibreglass mat, stuck down with yellow tape, the perspex tiles on the right shows the installation of a fabric mat. Cable Spacing The average cable spacing for underfloor heating mat systems available in the UK is 9cm, our mats have cables spaced from 6cm or 8cm intervals. This means we provide significantly more cable per/m 2 than our competitors. Our cables are close together and run at a lower temperature than those of most competitors meaning they can be installed on wooden subfloors and always provide a very even heat spread. A B The picture B (above) shows clearly how the adhesive makes a perfect bond with the sub-floor when using a fabric mat. 11 Quality Underfloor Heating

The FWC mats have many unique selling points over competitor systems At 160 or 200watts per m 2 this mat can be used as sole heating* Fabric backing Safer connection cables Extra layer of insulation around heating cables Extra metre of connection cable Our systems are better from the connection cable to the end of the mat, competitors are cheap for a reason. We are so confident in our products that we giv them a 10-year full floor (that s floor tiles as well) guarantee. We are willing to up this to a lifetime guarantee that would still include the 10-year FFG - no one offers this level of assurance to their customers. Can be used safety in wet rooms (IPX 7 rating) Only 7m cable spacing so your clients can install this system on any sub-floor prepared for tiling. Correct labelling to meet safety directives The Floor Warming Company Ltd Domoteck House Unit C, Eskdale Road Uxbridge UB8 2RT Tel: 01895 257995 Fax: 01895 258027 Email: enquiries@floorwarmingcompany.co.uk Web: www.floorwarmingcompany.co.uk