QFP Carrier & Development Socket

Similar documents
Reflow Soldering Guidelines

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

Dacor Technical Service

METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE

Manufacturing Notes for RFMD2081

INSTALLATION. Glass Panel Doors (select models) CAUTION

Manufacturing Notes for RFDA0025

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

RFSW6132. Manufacturing Notes. Table of Contents. 1 Introduction... 2

Manufacturing Notes for RFPA2189

QK-IR2005. User s Manual

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

RFFM6403. Manufacturing Notes. Table of Contents

Inverted Through Board Surface

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

installation and operation manual for Hunter Ceiling Fans

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Preliminary specification

- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK

Multi Function Food Processor

Manufacturing Notes for RFPA2016

Convection Rework Made Easy

Item # Modular Blast CaBinEt instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

MULTI REACH Stick Vacuum

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Soft Sheer Vertical. Installation and Care Guide

MACHINE FROZEN CONCOCTION. Les meilleures margaritas sont originaires de Margaritaville

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

Installation. Leveling

Access Point Mounting Instructions

Universal Retention Modules 02 MAR 10 Rev A

π H-7147 SANITAIRE EON QUIET CLEAN VACUUM SAFETY uline.com

IntelliDoX Operator Manual

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

High-Density Industrial

Rework: IR Technology vs. Convection Air

User Manual. Compact Bagged Vacuum Cleaner. Dog & Cat W2000

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

Installation and Maintenance Manual IM 1038

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

DOUBLE DISHDRAWER TM DISHWASHER

QUICK BGA2015. Precision BGA Rework System. Features:

Application Note 319. Flex Power Modules. Repair/Rework Recommendations for. Flex Power Modules

Multi-Cyclonic Vacuum USER GUIDE

Installation Instructions

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

QUICK BGA2015 BGA/SMD Rework System. Operation Manual

Here is what comes in your box:

Once you ve located these components, set them aside so they ll be handy as you begin the installation process. Screw Holes

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Fume Extraction Workstation

OWNER S MANUAL COMMERCIAL COLD PRESS JUICER

of the openings blocked with any object that may restrict the airflow.

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Fillmore Small Pendant Assembly and Installation Instructions

Installation Instructions

DYSON CUSTOMER HELPLINE

Convertible Cleaner. Owners Manual

Room Sensor for BACnet VAV Actuator

MINI BLINDS Classic GETTING STARTED STANDARD HARDWARE. A few simple tools are required: OPTIONAL HARDWARE

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual

UPRIGHT VACUUM 12-INCH CLEANING PATH

HOT BAR REFLOW SOLDERING FUNDAMENTALS by Amada Miyachi Europe A high quality Selective Soldering Technology

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

AIRRAM Vacuum USER GUIDE 1984/2144 SERIES

Big Board Rework. Joerg Nolte Ersa GmbH Wertheim, Germany

MALIBU STAR OWNER S MANUAL


FM740 INSTRUCTION MANUAL VACUUM CLEANER. Contents HOUSEHOLD USE ONLY

WAILEA OWNER S MANUAL

DOUBLE DISHDRAWER TM DISHWASHER

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

TECHNICAL INFORMATION Touchtronic Clothes Dryers

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Vacuum Cleaner User's manual

BGA Rework Station TOUCHBGA GM490 User Manual

PackardInfo.com. HOW TO: Rebuild a Trico Mag Nu Matic Vacuum Washer Pump. Introduction

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

HW-17 Record Cleaning Machine Setup and Instruction Manual

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INSTALLATION INSTRUCTIONS

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

Owner s Guide and Installation Manual

PTAC WIRELESS KITS (DT01*, DS01*, DD01*) INSTALLATION INSTRUCTIONS

Register your purchase. Keep this inforrnation. For Electrolux service

474A+ TIP CARE AND USE INSTRUCTION MANUAL DESOLDERING STATION

Transcription:

QFP Carrier & Development Socket August 1999, ver. 13 Data Sheet Features Quad flat pack (QFP) carriers protect fragile leads on QFP devices during shipping and device handling. QFP development sockets allow on-board electrical and mechanical prototype testing with QFP packages. Carriers and development sockets are available for 100-, 160-, 208-, 240-, and 304-pin devices. Development socket footprints are compatible with QFP footprints, providing a smooth transition from prototype to production. Together, carriers and sockets help prevent electrostatic damage to the devices while providing excellent AC circuit performance. General Description Altera QFP carriers and development sockets protect the fragile leads on QFP devices during shipping and throughout the development cycle. Each socket is designed with a lead footprint that is compatible with the device, so it can be used during both mechanical and electrical prototyping. QFP carriers and development sockets are currently available for 100-, 160-, 208-, 240-, and 304-pin QFP packages. Figure 1 shows the carrier and development socket for the 100-pin QFP device (the 160- and 208-pin QFP carriers and development sockets are similar). Figure 1. 100-Pin QFP Carrier & Development Socket Development Socket Lid QFP Carrier QFP Device Development Socket Base Beveled Corner Indicates Location of Pin 1 Altera Corporation 1 A-DS-QFP-13

Figure 2 shows the carrier and development socket for the 240-pin QFP device (the 304-pin QFP carrier and development socket are similar). Figure 2. 240-Pin QFP Carrier & Development Socket Lid Removal Tool Development Socket Lid Press QFP Carrier & QFP Device Development Socket Base Beveled Corner Indicates Location of Pin 1 QFP Carrier The carrier is a static-dissipative, molded plastic shell that holds the QFP device in a secure frame to prevent mechanical damage to the device leads. The device is held in the carrier by recessed plastic clips (two clips on the 100-pin carrier and four clips on the 160-, 208-, 240-, and 304-pin carriers). Figure 3 shows the dimensions of the QFP carriers. All MAX 9000, MAX 7000, MAX 3000 and MAX 5000 QFP devices with 100 to 304 pins can be ordered in carriers, which eliminates the need to handle the delicate device leads. The devices and carriers are packaged in antistatic rails. Devices can be programmed and erased while in the carrier. EPROMbased QFP devices are erased with a UV lamp; EEPROM-based QFP devices are erased electrically in a programming adapter. 1 QFP devices without protective carriers should be handled with a vacuum wand in an electrostatically protected workplace to reduce the possibility of mechanical or electrical device damage. 2 Altera Corporation

Figure 3. QFP Carrier Dimensions Dimensions are shown in millimeters. The carrier is rated from 65 C to 155 C, and is qualified to handle commercial and industrial operating temperatures. Illustrations are not drawn to scale. 100-Pin QFP Carrier 160- & 208-Pin QFP Carrier L H L H W Indicates Location of Pin 1 Indicates Location of Pin 1 W 160 Indicates Pin Count 240- & 304-Pin QFP Carrier L Pin 1 Indicates Location of Pin 1 H W 240 Indicates Pin Count Pin Count L W H 100 25.2 21.2 4.2 160 33.2 35.2 5.1 208 33.2 35.2 5.1 240 37.0 40.0 6.4 304 45.0 48.0 6.4 Altera Corporation 3

QFP Development Socket The QFP development socket footprint is compatible with the lead footprint of the QFP device. The socket ensures the device s electrical connection to the printed circuit board (PCB) and provides excellent AC circuit performance, including low noise, low capacitance, and low inductance. Although the QFP development socket is designed to minimize noise, interconnect capacitance, and inductance, these effects can be further reduced by mounting the device directly on the PCB for production. 1 Altera recommends using the QFP development socket for prototyping only. Altera does not recommend using sockets for production. Figure 4 shows the dimensions of the QFP development socket. Details A and B show the PCB pad layout length and width recommended for use with the development socket. These industry-standard pad layout dimensions are for the gull-wing lead that is typically found on QFP packages. The layout pad extends from 0.05 mm to 0.13 mm beyond each side of the lead width (A1), and 0.5 mm beyond each side of the lead length (A2), as shown in Details A and B, respectively. A layout pad of these dimensions is also suitable for use with QFP devices that do not use carriers. To ensure correct board layout, pad sizes must be compatible with the development socket and the QFP device leads. 4 Altera Corporation

Figure 4. QFP Development Socket Dimensions Dimensions are shown in millimeters. The tolerance of all layout pad dimensions is ±0.025 mm. The continuous duty rating for the development socket is 65 C to 155 C. The carrier and development socket are qualified to handle commercial and industrial operating temperatures. Detail A Development Socket Length Development Socket Width C Layout Pad A1 Development Socket Lead Board B2 D2 See Detail A A1 B1 A3 BSC 0.05 0.13 D1 Recommended Board Layout 4.5 E2 Contact & Lid Detail QFP Device Development Socket QFP Carrier E1 F1 B1 Package Lead F2 B2 Diameter = 1.19 Contact Detail B For 240- and 304-pin QFP packages, leave this space for removal of development socket lid..25 P2 Alignment Post Layout Pad (Length) Contact Development Socket Base Board See Detail B A2 P1 A2 0.5 0.5 Pin Count A1 A2 A3 B1 B2 C D1 D2 E1 E2 F1 F2 P1 P2 100 0.20 0.93 0.65 25.00 19.00 12.00 31.51 25.54 23.63 17.63 18.85 12.35 1.00 1.50 160 0.20 0.93 0.65 33.80 33.80 12.80 39.80 39.80 32.08 32.08 25.35 25.35 1.00 1.50 208 0.20 0.93 0.50 33.82 33.82 12.80 39.80 39.80 31.68 31.68 25.50 25.50 1.00 1.50 240 0.20 0.93 0.50 34.00 34.00 14.30 44.00 42.90 35.20 35.20 29.50 29.50 1.00 1.50 304 0.20 0.93 0.50 42.00 42.00 14.30 52.00 50.90 43.30 43.30 37.50 37.50 1.00 1.50 Tolerance ±0.12 ±0.12 ±0.12 ±0.12 ±0.12 ±0.40 ±0.20 ±0.20 ±0.12 ±0.12 ±0.12 ±0.12 ±0.12 ±0.12 Altera Corporation 5

The development socket base is designed to withstand the temperatures required by industry-standard solder reflow technology. The soldering time at the allowed maximum temperature of 220 C should be approximately 10 seconds. The soldering temperature should not increase more than 3 C per second. To perform reflow operations, Altera recommends using 100% forced convection reflow ovens rather than infrared (IR) reflow ovens. The large thermal mass of the development socket base shields or shadows the solder paste from the IR radiation used in IR reflow ovens. Shadowing prevents the paste from heating and flowing properly. Improper heating and flowing of paste can cause inadequate lead contact with the circuit board and unacceptable solder joints. Ovens with 100% forced convection reflow provide the even and efficient heat transfer required to form an acceptable solder joint. 1 The development socket lid and the QFP carrier should not be subjected to the solder reflow process. They cannot withstand the typical reflow temperatures of 180 C to 220 C, and can be harmed by the cleaners and solvents used in the reflow process. Only the development socket base should be subjected to solder reflow. However, the socket lid and carrier are qualified to handle commercial and industrial operating temperatures. With the appropriate solder mask, multiple development sockets can be closely spaced on the board. Three alignment posts ensure correct orientation and provide sufficient registration for reflow soldering. When other components must be placed near the development socket, the designer must make sure that component leads do not conflict with the outline of the development socket. The socket lid holds the QFP carrier in the development socket base and braces the carrier by pressing the QFP device leads against the electrical contacts in the socket base. The contact material in the development socket base is beryllium copper with a tin/lead plating. These contacts connect the device leads to the PCB, ensuring a positive electrical connection that is not susceptible to mechanical interruption through jarring or impulsive shocks. The carrier design ensures that the pressure of the socket contacts does not significantly affect the coplanarity of the device leads. This carrier/socket combination allows the designer to perform mechanical analysis during the functional prototyping cycle. Altera also provides a tool to extract the QFP device from the carrier. See Extracting a Device from the QFP Carrier on page 11 of this data sheet for complete details. 6 Altera Corporation

Using the QFP Carrier & Development Socket This section gives step-by-step instructions for the following procedures: Inserting the QFP carrier and device into the development socket Removing the QFP carrier and device from the development socket Programming a device in the QFP carrier Extracting a device from the QFP carrier 1 The device should be removed from the QFP carrier only after it has been programmed and is ready to be soldered onto the PCB. Inserting the QFP Carrier & Device into the Development Socket To insert a 100-, 160-, or 208- pin QFP carrier and device into the development socket: 1. Align the QFP carrier and device on the development socket by matching the beveled corner of the carrier to the beveled corner of the socket base and aligning the corresponding dots. 2. Place the QFP carrier and device in the development socket base. 3. Place the socket lid over the socket base and press down firmly on all four corners of the lid. Clicking sounds are clearly audible as the socket lid is pressed into place. See Figure 5. 4. Visually confirm that the tabs on all sides of the lid have locked onto the development socket base. Figure 5. Inserting a 100-, 160-, or 208-Pin QFP Carrier & Device into the Development Socket Altera Corporation 7

1 When placing the development socket lid onto or removing it from the socket base, Altera recommends bracing the side of the PCB opposite the development socket to prevent the PCB from flexing. Some insertion force is required to seat a high-pin-count device. If the PCB is not properly braced, repeated flexing of the PCB can cause excessive wear, resulting in cracks in the solder joints and in the PCB traces. To insert a 240- or 304-pin QFP carrier and device into the development socket: 1. Align the QFP carrier and device on the development socket base by matching pin 1 of the device to pin 1 of the socket base. 2. Place the QFP carrier and device in the development socket base. 3. Align the development socket lid as shown in Figure 6. Figure 6. Aligning a 240- or 304-Pin QFP Development Socket Lid Square Knob Press 4. Slide the development socket lid horizontally on top of the development socket base until the lid reaches the square knobs on the sides of the socket base. 5. While pressing down on the part of the development socket lid labeled with the word Press, slide the development socket lid until the square knobs on the socket base fit firmly in the lid. See Figure 7. 8 Altera Corporation

Figure 7. Sliding a 240- or 304-Pin QFP Development Socket Lid into Place Square Knob Removing the QFP Carrier & Device from the Development Socket For 100-, 160-, 208-, 240-, and 304-pin packages, Altera does not recommend removing the development socket lid at temperatures below 10 C. To remove a 100-, 160-, or 208-pin QFP carrier and device from the development socket: 1. Place the removal tool over the QFP socket lid, as shown in Figure 8. 2. Gently press down, making sure that the edges of the tool fit into the slots on the top of the lid. Clicking sounds will be clearly audible. To ensure that all four tabs of the 160- and 208-pin QFP carrier have been unlatched from the development socket base, twist the removal tool back and forth after it is pressed down. 3. While maintaining pressure, lift the lid and removal tool together. 4. Remove the QFP carrier and device. 1 Altera recommends removing a QFP carrier and device from a development socket no more than 25 times. Altera Corporation 9

Figure 8. Removing a 100-, 160-, or 208-Pin QFP Carrier & Device from the Development Socket 100-Pin Carrier & Device 160- or 208-Pin Carrier & Device To remove a 240- or 304-pin QFP carrier and device from the development socket: 1. Place the lid removal tool in the slot between the edge of the development socket lid and the edge of the development socket base. See Figure 9. Figure 9. Removing a 240- or 304-Pin QFP Carrier & Device from the Development Socket Press Lid Removal Tool Square Knob 10 Altera Corporation

2. Tilt the top of the lid removal tool toward the center of the development socket until the development socket lid slides away from the square knobs on the sides of the socket base. 3. Remove the lid removal tool, slide the development socket lid back, and remove the lid from the development socket base. Programming a Device in the QFP Carrier QFP devices that are shipped in the protective QFP carriers are ready to be programmed with an Altera or third-party programming adapter. With Altera programming software and hardware, test vectors can be directly applied to the device for programming verification and functional testing. Devices in QFP packages can also be programmed with industry-standard programming hardware from other manufacturers. To program a device in the QFP carrier: 1. Place the QFP carrier with the device into the programming adapter, making sure that the carrier and adapter are aligned correctly. 2. Close the retaining latch by pressing the latch against the socket. A clicking sound is clearly audible as the latch fastens over the socket. 1 The retaining latch on the clamshell-style programming adapter socket ensures good electrical contact between the device leads and the socket. To ensure proper programming, the retaining latch must be closed after the QFP carrier and device are placed into the programming adapter. Extracting a Device from the QFP Carrier Altera offers carrier extraction tools for 100-, 160-, 208-, 240-, and 304-pin devices, and recommends using the extraction tool to extract devices from QFP carriers. Table 1 shows the ordering codes for QFP carrier extraction tools. Table 1. QFP Carrier Extraction Tools Product Ordering Code 100-pin QFP carrier extraction tool PL-EXT1 160- and 208-pin QFP carrier extraction tool PL-EXT2 240-pin QFP carrier extraction tool PL-EXT4 304-pin QFP carrier extraction tool PL-EXT5 Altera Corporation 11

The QFP device fits in the QFP carrier extraction tool only when the device is correctly oriented in the carrier insertion slot. For 100-, 160-, and 208-pin QFP devices, the pin indicator on the corner of the device (as shown in Figure 3) should be aligned with the beveled corner of the extraction tool; a sliding platform slips over the QFP device, securing it in the slot and bending back the yellow retaining clips located on the corners of the QFP carrier. For 240- and 304-pin QFP devices, the pin indicator on the corner of the device (as shown in Figure 3) should be aligned with the pin indicator on the extraction tool. The extraction tool lid closes over the QFP device, bending back the yellow retaining clips located on all four corners of the QFP carrier. The yellow retaining clips lock in the open position. The extraction button on the extraction tool ejects the QFP device from the carrier and places the device directly onto a QFP handling tray or onto a catch plate, which is included with the extraction tool. The catch plate included with the extraction tool for 100-pin devices holds four devices; the catch plate included with 160-, 208-, 240-, and 304-pin devices holds two devices. The ridges on the bottom of the extraction tool help to align the extraction tool with the sides of the handling tray or catch plate. The default size of the extraction tool supports the Peak Plastic Corporation low-profile JEDEC trays listed in Table 2. Table 2. QFP Handling Tray Part Numbers Pin Count Peak Part Number 100 ND-1420-2.7-0611-8 Rev B 160 ND-2828-3.5-0308-8 Rev B 208 ND-2828-3.5-0308-8 Rev B 240 ND-3232-3.4-0308-6 Rev A 304 ND-4040-3.8-0206-8 A multi-device extraction tool is available for use in production environments. This tool extracts up to six QFP devices at a time into lowprofile JEDEC trays. Contact Altera Customer Marketing at (408) 544-7104 for more information. To extract a 100-, 160-, or 208-pin QFP device from the carrier using the extraction tool: 12 Altera Corporation

1. Align the ridges on the bottom of the extraction tool with the sides of an empty slot on the QFP handling tray. To ensure proper device orientation, align the beveled corner of the extraction tool with the beveled corner of the QFP handling tray. If a handling tray is not available, place the extraction tool over the catch plate provided. 2. Open the extraction tool by moving the sliding platform until the carrier insertion slot is completely exposed. 3. Place the carrier-protected QFP device into the carrier insertion slot. Align the beveled edge of the carrier with the beveled edge of the carrier insertion slot, and make sure that the carrier is flush with the platform base. 4. Move the sliding platform until it completely covers the QFP device. See Figure 10. Figure 10. Placing a 100-, 160-, or 208-Pin QFP Carrier & Device in the Extraction Tool Carrier Insertion Slot QFP Carrier QFP Device Platform Base Sliding Platform QFP Handling Tray Beveled Corner 5. With the QFP device completely covered, press down on the extraction button to release the QFP device from the carrier. Place it in the QFP handling tray or on the catch plate. See Figure 11. If a handling tray or a catch plate is not available, use a vacuum wand or other handling tool to move the QFP devices. Altera Corporation 13

Figure 11. Pressing the Extraction Button to Remove a 100-, 160-, or 208-Pin QFP Device from the QFP Carrier Extraction Button QFP Handling Tray To extract a 240- or 304-pin QFP device from the carrier using the extraction tool: 1. Place the extraction tool over the QFP handling tray by lining up the ridges on the bottom of the extraction tool with the sides of an empty slot. To ensure proper device orientation, align the pin indicator on the extraction tool with the beveled corner of the QFP handling tray. If a handling tray is not available, place the extraction tool over the catch plate provided. 2. Open the extraction tool by lifting the lid upwards and back until the carrier insertion slot is completely exposed. 3. Place the carrier-protected QFP device into the carrier insertion slot. Align the pin indicator on the corner of the carrier with the pin indicator on the corner of the extraction tool. 4. Lower the extraction tool lid down until it is completely closed over the QFP device. See Figure 12. 14 Altera Corporation

Figure 12. Placing a 240- or 304-Pin QFP Carrier & Device in the Extraction Tool QFP Device Pin 1 Indicator Beveled Corner QFP Carrier QFP Handling Tray Carrier Insertion Slot 5. With the QFP device completely covered, press down on the extraction button to release the QFP device from the carrier and place it in the QFP handling tray or on the catch plate. If a handling tray or a catch plate is not available, use a vacuum wand or other handling tool to move the QFP devices. Altera Corporation 15

Notes:

Copyright 1995, 1996, 1997, 1998, 1999 Altera Corporation, 101 Innovation Drive, San Jose, CA 95134, USA, all rights reserved. By accessing this information, you agree to be bound by the terms of Altera s Legal Notice.