Page 1 of 65 1/29/2016 3:12 PM. Committee Input No. 39-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Similar documents
(h) Pesticide Application.

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

First Revision No. 6-NFPA [ Section No. 2.2 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ]

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Public Comment No. 1-NFPA [ Section No ]

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Plant Processing and Extraction Facilities

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

2009 NFPA Text 2009 International Building Code Text Recommendation. NFPA IBC 2009 IBC is most recent

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION


TABLE OF CONTENTS. Part I Administrative... 1 CHAPTER 1 SCOPE AND ADMINISTRATION... 1

Above Ground Fuel Tank Requirements


Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

First Revision No. 20-NFPA [ Section No ]

First Revision No. 1-NFPA [ Chapter 2 ]

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

New Facilities. Minimum Requirements

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

APPENDIX A FEES SECTION FC A01 CERTIFICATES A01.1

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

OUTLINE FOR FIRE PREVENTION ACTIVITY

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

BUILDING/FIRE CODE REFERENCES 2006 EDITION

Winnipeg Fire Department Fire Prevention Branch

NFPA 30 FLC-FUN Public Inputs Page 1 of 26. Public Input No. 5-NFPA [ Section No. 2.3 ] 11/6/2015 7:41 AM

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

SEMICONDUCTOR FABRICATION FACILITIES

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

GASEOUS HYDROGEN SYSTEMS

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

Virginia Statewide Fire Prevention Code

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

LISTA DE CÓDIGOS Y NORMAS DE LA NFPA


2010 FIRE CODE OF NEW YORK STATE

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Throughout standard remove references to the following and replace with the following:

CHAPTER 45 REFERENCED STANDARDS

CHAPTER 45 REFERENCED STANDARDS

Public Comment No. 13-NFPA [ Section No ]

City of Grover Beach Building Division Fire & Life Safety Requirements CANNABIS CULTIVATION, MANUFACTURING AND LABORATORY FACILITIES

12/21/2015 National Fire Protection Association Report

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

January 1, 2014 Mandatory Effective Date

Smoke detection in hazardous areas:

Part I Extraction Process Equipment

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

Committee Input No. 60-NFPA [ Sections , ]

Safety Manual Section 7 Fire/Life Safety

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Committee on NFPA 30A

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Report on First Revisions with Statement June 2014 NFPA 101

Public Input No. 3-NFPA [ Chapter 2 ]

City of Cleveland. Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio Standard Operating Procedure 18

First Revision No. 82-NFPA [ Detail ] Submitter Information Verification Submitter Full Name: Organization:

SAF-BCF SECOND REVISIONS WITH STATEMENTS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

West Norriton Township

NFPA 1124 (2006 Edition) Compliance List. Permanent Store

Agency for Health Care Administration

Throughout standard remove references to the following and replace with the following:

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Fire Test Methods ASTM NFPA UL ISO IEC

5.07 Air Replenishment Systems

NFPA 45 NFPA 211 NFPA 1600

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Agency for Health Care Administration

CHAPTER 80 REFERENCED STANDARDS

MEMORANDUM. NFPA Technical Committee on Hazard and Risk of Contents and Furnishings. NFPA 556 First Draft TC FINAL Ballot Results (A2015)

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

Osceola County Department of Fire Rescue and Emergency Medical Services

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX

Transcription:

of 36 1/29/2016 3:12 PM Committee Input No. 39-NFPA 1-2015 [ Global Input ] Extracts from the following standards to be updated at the second draft stage: NFPA 10, Standard for Portable Fire Extinguishers, 2017 edition. NFPA 14, Standard for the Installation of Standpipe and Hose Systems, 2016 edition. NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2017 edition. NFPA 30, Flammable and Combustible Liquids Code, 2018 edition. NFPA 30A, Code for Motor Fuel Dispensing Facilities and Repair Garages, 2018 edition. NFPA 31, Standard for the Installation of Oil-Burning Equipment, 2016 edition. NFPA 36, Standard for Solvent Extraction Plants, 2017 edition. NFPA 52, Vehicular Fuel Systems Code, 2016 edition. NFPA 58, Liquefied Petroleum Gas Code, 2017 edition. NFPA 59A, Production, Storage, and Handling of Liquefied Natural Gas (LNG), 2016 edition. NFPA 61, Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities, 2017 edition. NFPA 70, National Electrical Code, 2017 edition. NFPA 70B, Recommended Practice for Electrical Equipment Maintenance, 2016 edition. NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2018 edition. NFPA 96, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, 2017 edition. NFPA 101, Life Safety Code, 2018 edition. NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, 2016 edition. NFPA 220, Standard on Types of Building Construction, 2018 edition. NFPA 318, Standard for the Protection of Semiconductor Fabrication Facilities, 2018 edition. NFPA 402, Guide for Aircraft Rescue and Fire-Fighting Operations, 2018 edition. NFPA 407, Standard for Aircraft Fuel Servicing, 2017 edition. NFPA 418, Standard for Heliports, 2016 edition. NFPA 472, Standard for Competence of Responders to Hazardous Materials/Weapons of Mass Destruction Incidents, 2018 edition. NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, 2017 edition. NFPA 1141, Standard for Fire Protection Infrastructure for Land Development in Suburban and Rural Areas, 2017 edition. NFPA 1144, Standard for Reducing Structure Ignition Hazards from Wildland Fire, 2018 edition. NFPA 5000, Building Construction and Safety Code, 2018 edition. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Sep 23 13:06:01 EDT 2015 Committee Statement Committee Statement: Extract updates. Response Message: Page 1 of 65

of 36 1/29/2016 3:12 PM Committee Input No. 42-NFPA 1-2015 [ Section No. 2.3.3 ] 2.3.3 API Publications. American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070. API-ASME Code for Unfired Pressure Vessels for Petroleum Liquids and Gases, Pre-July 1, 1961. API Specification 12B, Bolted Tanks for Storage of Production Liquids, 15th edition, 2008. API Specification 12D, Field Welded Tanks for Storage of Production Liquids, 11th edition, 2008. API Specification 12F, Shop Welded Tanks for Storage of Production Liquids 12th edition, 2008. API 620, Recommended Rules for the Design and Construction of Large, Welded, Low-Pressure Storage Tanks, 11th edition, Addendum 2, 2010. API Standard 650, Welded Steel Tanks for Oil Storage, 11th edition, Addendum 2, 2009. API Standard 653, Tank Inspection, Repair, Alteration, and Reconstruction, 4th edition, 2012. API Standard 2000, Venting Atmospheric and Low-Pressure Storage Tanks 5th edition, 1998. API 2350, Overfill Protection for Storage Tanks in Petroleum Facilities, 4th edition, 2012. API BULL 1529, Aviation Fueling Hose, 1998. API 607, Fire Test for Soft-Seated Quarter-Turn Valves, 1993. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 09:15:58 EDT 2015 Committee Statement Committee Statement: API publications to be updated at second draft stage. Response Message: Page 2 of 65

of 36 1/29/2016 3:12 PM Committee Input No. 45-NFPA 1-2015 [ Section No. 2.3.6 ] Page 3 of 65

of 36 1/29/2016 3:12 PM 2.3.6 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM A 395, Standard Specification for Ferritic Ductile Iron Pressure-Retaining Castings for Use at Elevated Temperatures, 1999 (reaffirmed 2009). ASTM D 5/D 5M, Standard Test Method for Penetration of Bituminous Materials, 2013. ASTM D 56, Standard Test Method for Flash Point by Tag Closed Cup Tester, 2005(reaffirmed 2010). ASTM D 92, Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester, 2012b. ASTM D 93, Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester, 2012. ASTM D 323, Standard Method of Test for Vapor Pressure of Petroleum Products (Reid Method), 2008. ASTM D 396, Standard Specification for Fuel Oils, 2010. ASTM D 635, Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position, 2010. ASTM D 1929, Standard Test Method for Determining Ignition Temperature of Plastics, 2012. ASTM D 2843, Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics, 2010. ASTM D 2859, Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials, 2006 (2011). ASTM D 2898, Standard Test Methods for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing, 2010. ASTM D 3278, Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus, 1996 (reaffirmed 2011). ASTM D 3699, Standard Specification for Kerosene, 2008. ASTM D 3828, Standard Test Methods for Flash Point by Small Scale Closed Cup Tester, 2012a. ASTM D 4359, Standard Test for Determining Whether a Material is a Liquid or a Solid, 1990 (reaffirmed 2012). ASTM D 5391, Standard Test for Electrical Conductivity and Resistivity of a Flowing High Purity Water Sample, 1999 (2009). ASTM D 6448, Industrial Burner Fuels from Used Lube Oils, 2009. ASTM D 6751, Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuel, 2010. ASTM D 6823, Commercial Burner Fuels from Used Lube Oils, 2008. ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials, 2013. ASTM E 108, Standard Test Methods for Fire Tests of Roof Coverings, 2011. ASTM E 119, Standard Test Methods for Fire Tests of Building Construction and Materials, 2012a. ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C, 2012. ASTM E 648, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source, 2010 e1. ASTM E 681, Standard Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases), 2009. ASTM E 814, Standard Test Method for Fire Tests of Through-Penetration Fire Stops, 2011a. ASTM E 1354, Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter, 2013. ASTM E 1537, Standard Test Method for Fire Testing of Upholstered Furniture, 2012. ASTM E 1590, Standard Test Method for Fire Testing of Mattresses, 2012. ASTM E 1591, Standard Guide for Obtaining Data for Deterministic Fire Models, 2007. ASTM E 1966, Standard Test Method for Fire-Resistive Joint Systems, 2007 (2011). ASTM E 2074, Standard Test Method for Fire Tests of Door Assemblies, Including Positive Pressure Testing of Side-Hinged and Pivoted Swinging Door Assemblies, 2000e1 (withdrawn 2007). ASTM E 2174, Standard Practice for On-Site Inspection of Installed Fire Stops, 2010a e1. ASTM E 2307, Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate-Scale, Multi-story Test Apparatus, 2010. ASTM E 2393, Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers, 2010a. ASTM E 2404, Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Polymeric (Including Vinyl) Wall or Ceiling Coverings, and of Facings and Wood Veneers Intended to be Applied on Site Over a Wood Substrate, to Assess Surface Burning Characteristics, 2012. ASTM E 2573, Standard Practice for Specimen Preparation and Mounting of Site-Fabricated Stretch Systems to Assess Surface Burning Characteristics, 2012. ASTM E 2599, Standard Practice for Specimen Preparation and Mounting of Reflective Insulation, Radiant Barrier, and Vinyl Stretch Ceiling Materials for Building Applications to Assess Surface Burning Characteristics, 2011. ASTM E 2652, Standard Test Method for Behavior of Materials in a Tube Furnace with a Cone-Shaped Airflow Stabilizer, at 750 Degrees C, 2012. ASTM F 852, Standard for Portable Gasoline Containers for Consumer Use, 2008. ASTM F 976, Standard for Portable Kerosene Containers for Consumer Use, 2008. Page 4 of 65

of 36 1/29/2016 3:12 PM Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 09:32:10 EDT 2015 Committee Statement Committee Statement: ASTM references to be updated at second draft stage. Response Message: Page 5 of 65

of 36 1/29/2016 3:12 PM Committee Input No. 47-NFPA 1-2015 [ Section No. 2.3.9 ] 2.3.9 FM Publications. FM Global, 1301 Atwood Avenue, P.O. Box 7500, Johnston, RI 02919. Approval Standard for Safety Containers and Filling, Supply, and Disposal Containers Class Number 6051 and 6052, May 1976. ANSI/FM 4880,American National Standard for Evaluating Insulated Wall or Wall and Roof/Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems, Interior or Exterior Finish Systems, 2007. Approval Standard for Plastic Plugs for Steel Drums, Class Number 6083, October 2006. Approval Standard 6921, Containers for Combustible Waste, 2004. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 09:45:58 EDT 2015 Committee Statement Committee Statement: FM publications to be updated at second draft stage (NFPA 30 and NFPA 101 extracts). Response Message: Page 6 of 65

of 36 1/29/2016 3:12 PM Committee Input No. 146-NFPA 1-2015 [ Section No. 2.3.11 ] 2.3.11 IIAR Publications. International Institute of Ammonia Refrigeration, 1001 N. Fairfax Street, Suite 503, Alexandria, VA 22314. ANSI/IIAR 2, Equipment, Design, and Installation of Closed-Circuit Ammonia Mechanical Refrigerating Systems, 2008. ANSI/IIAR 6, Maintenance and Inspection of Closed-Circuit Ammonia Mechanical Refrigerating Systems, 2016. ANSI/IIAR 7, Developing Operating Procedures for Closed-Circuit Ammonia Mechanical Refrigerating Systems, 2013. Submitter Information Verification Submitter Full Name: Kristin Bigda Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Mon Oct 19 19:56:20 EDT 2015 Committee Statement Committee Statement: Response Message: Referenced publication update. ANSI/IIAR 6 is anticipated to be complete prior to conclusion of the current NFPA 1 cycle. Page 7 of 65

of 36 1/29/2016 3:12 PM Committee Input No. 50-NFPA 1-2015 [ Section No. 2.3.14 ] 2.3.14 NRFC Publications. National Railroad Freight Committee, 222 South Riverside Plaza, Chicago, IL 60606-5945. Uniform Freight Classification (UFC), 2005. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 09:54:10 EDT 2015 Committee Statement Committee Statement: NRFC publication to be updated at second draft stage (NFPA 30 extract). Response Message: Page 8 of 65

of 36 1/29/2016 3:12 PM Committee Input No. 53-NFPA 1-2015 [ Section No. 2.3.16 ] 2.3.16 STI Publications. Steel Tank Institute, 570 Oakwood Road, Lake Zurich, IL 60047. STI SP001, Standard for the Inspection of Aboveground Storage Tanks, 5th edition, 2011. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 10:03:04 EDT 2015 Committee Statement Committee Statement: STI publication to be updated at second draft stage (NFPA 30 extract). Response Message: Page 9 of 65

0 of 36 1/29/2016 3:12 PM Committee Input No. 54-NFPA 1-2015 [ Section No. 2.3.17 ] Page 10 of 65

1 of 36 1/29/2016 3:12 PM 2.3.17 UL Publications. Page 11 of 65

Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096. ANSI/UL 8, Standard for Water Based Agent Fire Extinguishers, 2005, Revised 2009. ANSI/UL 9, Standard for Fire Tests of Window Assemblies, 2009. ANSI/UL 10B, Standard for Fire Tests of Door Assemblies, 2008, Revised 2009. ANSI/UL 10C, Standard for Positive Pressure Fire Tests of Door Assemblies, 2009. ANSI/UL 30, Standard for Metal Safety Cans, 1995, Revised 2009. UL 58, Standard for Steel Underground Tanks for Flammable and Combustible Liquids, 1996, Revised 1998. ANSI/UL 80, Standard for Steel Tanks for Oil Burner Fuels and Other Combustible Liquids, 2007, Revised 2009. ANSI/UL 142, Standard for Steel Aboveground Tanks for Flammable and Combustible Liquids, 2006, Revised 2010. ANSI/UL 147A, Standard for Nonrefillable (Disposable) Type Fuel Gas Cylinder Assemblies, 2005, Revised 2009. ANSI/UL 147B, Standard for Nonrefillable (Disposable) Type Metal Container Assemblies for Butane, 2005, Revised 2008. ANSI/UL 154, Standard for Carbon Dioxide Fire Extinguishers, 2005, Revised 2009. UL 162, Standard for Safety for Foam Equipment and Liquid Concentrates, 1994. ANSI/UL 197, Standard for Commercial Electric Cooking Appliances, 2010, Revised 2011. ANSI/UL 263, Standard for Fire Tests of Building Construction and Materials, 2011. ANSI/UL 294, Standard for Access Control System Units, 1999, Revised 2010. ANSI/UL 296A, Standard for Waste Oil-Burning Air-Heating Appliances, 2010. ANSI/UL 299, Standard for Dry Chemical Fire Extinguishers, 2012. ANSI/UL 300, Standard for Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Areas, 2005, Revised 2010. ANSI/UL 340, Test for Comparative Flammability of Liquids, 2009. ANSI/UL 499, Standard for Electric Heating Appliances, 2005. ANSI/UL 555, Standard for Fire Dampers, 2006, Revised 2012. ANSI/UL 555S, Standard for Smoke Dampers, 1999, Revised 2012. ANSI/UL 567, Standard for Emergency Breakaway Fittings, Swivel Connectors and Pipe Connection Fittings for Petroleum Products and LP-Gas, 2003, Revised 2011. ANSI/UL 626, Standard for Water Fire Extinguishers, 2005, Revised 2012. ANSI/UL 710B, Standard for Recirculating Exhaust Systems, 2004, Revised 2009. ANSI/UL 711, Standard for Rating and Fire Testing of Fire Extinguishers, 2004, Revised 2009. ANSI/UL 723, Standard for Test for Surface Burning Characteristics of Building Materials, 2008, Revised 2010. ANSI/UL 790, Standard for Safety for Tests for Fire Resistance of Roof Covering Materials, 2004, Revised 2008. ANSI/UL 842, Standard for Valves for Flammable Fluids, 2007, Revised 2011. ANSI/UL 900, Standard for Air Filter Units, 2004, Revised 2009. ANSI/UL 913, Standard for Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III Division 1, Hazardous (Classified) Locations, 2006, Revised 2010. ANSI/UL 924, Standard for Emergency Lighting and Power Equipment, 2006, Revised 2011. UL 971, Standard for Nonmetallic Underground Piping for Flammable Liquids, 1995, Revised 2006. ANSI/UL 1037, Standard for Antitheft Alarms and Devices, 1999, Revised 2009. ANSI/UL 1040, Standard for Fire Test of Insulated Wall Construction, 1996, Revised 2007. ANSI/UL 1313, Standard for Nonmetallic Safety Cans for Petroleum Products, 1993, Revised 2007. UL 1316, Standard for Glass-Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols, and Alcohol- Gasoline Mixtures, 2006. UL 1479, Standard for Fire Tests of Through-Penetration Firestops, 2003, Revised 2010. UL 1573, Standard for Stage and Studio Luminaires and Connector Strips, 2003. UL 1640, Standard for Portable Power-Distribution Equipment, 2007. ANSI/UL 1715, Standard for Fire Test of Interior Finish Material, 1997, Revised 2008. ANSI/UL 1746, Standard for External Corrosion Protection Systems for Steel Underground Storage Tanks, 2007. UL 1803, Standard for Factory Follow-up on Third Party Certified Portable Fire Extinguishers, 2012. UL 1975, Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes, 2006. ANSI/UL 1994, Standard for Luminous Egress Path Marking Systems, 2004, Revised 2010. UL 2079, Standard for Tests for Fire Resistance of Building Joint Systems, 2004, Revised 2008. UL 2080, Standard for Fire Resistant Tanks for Flammable and Combustible Liquids, 2000. Page 12 of 65 2 of 36 1/29/2016 3:12 PM

3 of 36 1/29/2016 3:12 PM ANSI/UL 2085, Standard for Protected Aboveground Tanks for Flammable and Combustible Liquids, 1997, Revised 2010. ANSI/UL 2129, Standard for Halocarbon Clean Agent Fire Extinguishers, 2005, Revised 2012. ANSI/UL 2208, Standard for Solvent Distillation Units, 2005, Revised 2011. UL 2245, Standard for Below-Grade Vaults for Flammable Liquid Storage Tanks, 2006. UL 2368, Standard for Fire Exposure Testing of Intermediate Bulk Containers for Flammable and Combustible Liquids, 2012. ANSI/UL 2586, Standard for Hose Nozzle Valves, 2011, Revised 2012. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 10:06:21 EDT 2015 Committee Statement Committee Statement: UL publications to be updated at second draft stage (numerous extracts). Response Message: Public Input No. 248-NFPA 1-2015 [Section No. 2.3.17] Page 13 of 65

4 of 36 1/29/2016 3:12 PM Committee Input No. 55-NFPA 1-2015 [ Section No. 2.3.18 ] 2.3.18 ULC Publications. Underwriters' Laboratories of Canada, 7 Underwriters Road, Toronto, Ontario M1R 3B4, Canada. CAN/ULC-S503, Standard for Carbon-Dioxide Fire Extinguishers, 2005, Revised 2010. CAN/ULC-S504, Standard for Dry Chemical Fire Extinguishers, 2002, Revised 2009. CAN/ULC-S507, Standard for Water Fire Extinguishers, 2005, Revised 2010. CAN/ULC-S508, Standard for Rating and Testing of Fire Extinguishers and Fire Extinguishing Agents, 2004, Revised 2009. CAN/ULC-S512, Standard for Halogenated Agent Hand and Wheeled Fire Extinguishers, 2007. CAN/ULC-S554, Standard for Water Based Agent Fire Extinguishers, 2005, Reaffirmed 2010. CAN/ULC-S566, Standard for Halocarbon Clean Agent Fire Extinguishers, 2005, Revised 2007. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Thu Sep 24 10:09:49 EDT 2015 Committee Statement Committee Statement: ULC publications to be updated at second draft stage (NFPA 10 extracts). Response Message: Public Input No. 218-NFPA 1-2015 [Section No. 2.3.18] Page 14 of 65

5 of 36 1/29/2016 3:12 PM Committee Input No. 155-NFPA 1-2015 [ Chapter 31 [Title Only] ] Forest Products and Biomass Feedstocks Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Tue Oct 20 14:06:50 EDT 2015 Committee Statement Committee Statement: Response Message: The modification of the Chapter name is to provide for material covered by a new section to be added to the chapter dealing with biomass feedstock utilized at biomass to ethanol industrial facilities. The revision is being moved as a committee input to solicit public comments and to allow further review at the second draft stage. Public Input No. 238-NFPA 1-2015 [Chapter 31 [Title Only]] Page 15 of 65

6 of 36 1/29/2016 3:12 PM Committee Input No. 156-NFPA 1-2015 [ Section No. 31.1 ] 31.1 * General. The storage, manufacturing, and processing of timber, lumber, plywood, veneers, biomass feedstock and by-products shall be in accordance with this chapter and NFPA 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Tue Oct 20 14:08:23 EDT 2015 Committee Statement Committee Statement: Response Message: This submittal is part of a group of submittals to provide for requirements addressing the exterior storage of biomass feedstock utilized for biomass to ethanol manufacturing facilities. The revision is being moved as a committee input to solicit public comments and to allow further review at the second draft stage. Public Input No. 240-NFPA 1-2015 [Section No. 31.1] Page 16 of 65

7 of 36 1/29/2016 3:12 PM Committee Input No. 158-NFPA 1-2015 [ New Section after 31.3 ] 31.3.10 Outside Storage of Biomass Feedstock 31.3.10.1 The fire hazard potential inherent in biomass feedstock storage operations with large quantities of combustible materials shall be controlled by a positive fire prevention program under the direct supervision of upper level management that shall include the following: (1) Selection, design, and arrangement of storage yard areas and materials-handling equipment based upon proven fire prevention and protection principles (2) Means for early fire detection, transmission of alarm, and fire extinguishment (3) Establishment of control over the various factors that lead to spontaneous heating, including provisions for monitoring the internal condition of the pile (4) Fire department access roads to separate large stacks and provide access for effective fire-fighting operations (5) Separation of yard storage from yard buildings and other exposing properties (6) Effective fire prevention maintenance program, including regular yard inspections by trained personnel 31.3.10.2 Bale stacks shall not exceed 25 feet (7620 mm) in height, 50 feet (15 240 mm) in width and 150 feet (45 720 mm) in length. 31.3.10.2.1 Bale stacks shall be in a maximum grouping of two bale stacks separated by 160 feet ( 48 770 mm) from each other with each group of two bale stacks separated from the next group of bale stacks by 400 feet ( 121 900 mm). 31.3.10.3 The storage site shall be reasonably level, on solid ground. 31.3.10.4 Access to the plant and yard from public highways shall be provided by all-weather roadways capable of supporting fire department apparatus. 31.3.10.5 All sides of each storage site shall be accessible by means of fire department access roads. 31.3.10.6 A fire department access road width of 1 1 2 times the bale stack height but not less than 20 ft (6 m) shall be provided, with fire department access roads between each set of two bale stack groupings. 31.3.10.7 Fire department access roads for access across each end, with a clear space of not less than 100 ft (30 m) to adjacent bale stack rows or other exposed property, shall be provided. 31.3.10.8 Power-operated, shovel-type or scoop-type vehicles, dozers, bale movers or similar equipment shall be available for use in moving stored material for fire fighting. 31.3.10.9 Training of the plant emergency organization also shall include procedures and precautions to be observed by yard crews employing power equipment in fighting internal fires. 31.3.10.10 Portable fire extinguishers for Class A fires shall be provided in accordance with Section 13.6 on all vehicles operating in the storage yard in addition to the normal Class B units for the vehicle. 31.3.10.11 Lightning protection shall be provided for the outside storage yard in accordance with NFPA 780 31.3.10.12 Outside storage yards shall be secured against unauthorized access in an approved manner. 31.3.10.13 Water supplies shall be provided in accordance with this Code. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Tue Oct 20 14:10:37 EDT 2015 Committee Statement Committee Statement: The purpose of this proposal is to provide for the safe storage of biomass feedstock at biomass to ethanol manufacturing facilities. Existing general requirements for the storage of agricultural products are not sufficient for these types of operations. Some of the language proposed is from other comparable sections of NFPA 1. The storage arrangement dimensions is based upon current operations after shorter separation distances were found to be insufficient to retard fire spread. The requirements for securing the site in an approved manner and for the provision of lightning protection is in recognition of the two main causes of fires in this type of storage, arson and lightning strikes. The revision is being moved as a committee input to solicit public comments and to allow further review at the second draft Page 17 of 65

8 of 36 1/29/2016 3:12 PM Response Message: stage. Public Input No. 241-NFPA 1-2015 [New Section after 31.3] Page 18 of 65

9 of 36 1/29/2016 3:12 PM Committee Input No. 157-NFPA 1-2015 [ Section No. 31.3.1.1 ] 31.3.1.1 The requirements of this chapter shall apply to the outside storage of the following: (1) Lumber and wood panel products at retail and wholesale lumber storage yards (2) Lumber and wood panel products at other than retail and wholesale storage yards (3) Ties, poles, piles, posts, and other similar forest products at pressure-treating plant yards (4) Outside storage of wood chips, hogged material, and wood by-products (5) Logs (6) Outside storage of biomass feedstocks Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Tue Oct 20 14:09:42 EDT 2015 Committee Statement Committee Statement: Response Message: The purpose of this submittal is to add storage requirements for biomass feedstock that is utilized for the manufacturing of ethanol. The stocks could include bales of corn stover, switch grass and/or hay. The general requirements for the storage of agricultural products are not appropriate for this activity. The revision is being moved as a committee input to solicit public comments and to allow further review at the second draft stage. Public Input No. 239-NFPA 1-2015 [Section No. 31.3.1.1] Page 19 of 65

0 of 36 1/29/2016 3:12 PM Committee Input No. 161-NFPA 1-2015 [ Section No. 45.1.2 ] 45.1.2 * Chapter 45 shall not apply to buildings completely protected by an approved automatic fire-extinguishing system; however, this exclusion does not preclude the need for good housekeeping. Chapter 45 shall not apply to biomass feedstock regulated by Chapter 31. Submitter Information Verification Submitter Full Name: Gregory Harrington Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Oct 21 12:53:21 EDT 2015 Committee Statement Committee Statement: Response Message: This is part of a group of proposals suggesting language in Chapter 31 for the safe storage of biomass feedstock utilized in the manufacture of ethanol. The general requirements for the storage of agricultural products does not appropriately address the safety of biomass outside storage at biomass to ethanol facilities. Public Input No. 245-NFPA 1-2015 [Section No. 45.1.2] Page 20 of 65

1 of 36 1/29/2016 3:12 PM Committee Input No. 152-NFPA 1-2015 [ Chapter 46 ] Chapter 46 Reserved Reserved Marijuana Growing, Processing or Extraction Facilities See attached. Supplemental Information File Name Marijuana_and_NFPA_1_V2-_DL.docx Description Submitter Information Verification Submitter Full Name: Kristin Bigda Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Mon Oct 19 20:32:29 EDT 2015 Committee Statement Committee Statement: Response Message: Marijuana growing, processing, or extraction facilities present unique hazards and safety concerns that should be addressed in NFPA 1. Currently, there is no guidance in the Code specific to these types of facilities. The new chapter is being proposed as a Committee Input as is not complete at this time. The committee is requesting additional feedback and comments for the public. In addition, a task group has been established to further review and develop the requirements and will present its work during the Second Draft meeting. Page 21 of 65

Chapter 46 Marijuana Growing, Processing or Extraction Facilities 46.1 General 46.1.1 The growing, processing or extraction of marijuana within buildings shall comply with the requirements of chapter 46. 46.1.2 Chapter 46 shall not apply to the retail sales of marijuana. 46.2 Application 46.2.1 Chapter 46 shall apply to the following: 1. The commercial scale growing and processing of marijuana within a building. 2. The use of fumigants within buildings used for commercial scale growing operations. 3. The commercial scale extraction processing of oils and fats by the use of flammable or combustible liquids, flammable gases, liquefied petroleum gases or nonflammable gases, hereinafter referred to as solvents. The extraction process includes the act of extraction of the oils and fats by use of a solvent, desolventizing of the raw material and production of the miscella, distillation of the solvent from the miscella and solvent recovery. The use, storage, transfilling, and handling of hazardous materials in these facilities shall comply with this chapter, other applicable provisions of this code. 46.2.2 Chapter 46 shall not apply to extraction processes that use liquids that are miscible with water. 46.3 Multiple Hazards. Where a material, its use or the process it is associated with poses multiple hazards, all hazards shall be addressed in accordance with Section 5001.1 and other material specific chapters. 46.4 Existing building or facilities. Existing buildings or facilities used for the growing or processing of marijuana shall comply with this chapter. 46.5 Permits. Permits shall be required as set forth in Section 1.12 46.4 DEFINITIONS (Possible replicated in Chapter 3) 46.4.1 Marijuana extraction facility (MEF): A building used for the solvent-based extraction process of marijuana. 46.4.2 Marijuana extraction equipment (MEE): Equipment or appliances used for the extraction of botanical material such as essential oils, from marijuana. 46.4.3 Marijuana extraction room (MER): The room or space in which the solvent based extractions occur. 46.4.4 Finding: The results of an inspection, examination, analysis or review. 46.4.5 Observation: A practice or condition not technically noncompliant with other regulations or requirements, but could lead to noncompliance if left unaddressed. 46.4.6 Desolventizing: The act of removing a solvent from a material. 46.4.7 Miscella: A mixture, in any proportion, of the extracted oil or fat and the extracting solvent. 46.4.8 Transfilling: The process of taking a gas source, either compressed or in liquid form (usually in bulk containers), and transferring it into a different container (usually a smaller compressed cylinder). 46.5 GROWING OR PRODUCTION OF MARIJUANA 46.5.1 Controlled egress or access. Egress doors, whether access-controlled or electromagnetically locked egress doors shall comply with the respective section of Chapter 14. 46.5.2 Ventilation for light fixtures. Light fixture ductwork shall be installed in accordance with manufacturer and NFPA 90A. 46.5.3 Odor control. The use of ozone generators used for odor control shall be in accordance with Chapter 54. Page 22 of 65

46.5.4 Interior Finish. The use of any plastic including mylar or panda sheeting to enclose rooms or cover any walls or ceilings must be installed in accordance with the building code and this code. If plastic materials are used, the material shall comply with the building code and Section 12.5 of this code. The hanging of plastic from ceiling or from suspended overhead structures to create wall dividers is not allowed. 46.5.5 Fumigation. Any marijuana growing, processing, extraction or retail facility that is fumigated shall comply with this section. Fumigation for marijuana growing, processing, extraction or retail facilities includes the production or use of sulfur dioxide. 46.5.5.1 Sources of ignition. Fires, open flames and similar sources of ignition shall be eliminated from the space under fumigation or insecticidal fogging. Heating, where needed, shall be of an approved type. 46.5.5.1.1 Electricity. Electricity in any part of the building, structure or space where operation of switches or electrical devices, equipment or systems could serve as a source of ignition shall be shut off. 46.5.5.1.2 Electronic devices. Electronic devices, including portable equipment and cellular phones, shall be shut off. Telephone lines shall be disconnected from telephones. 46.5.5.1.3 Duration. Sources of ignition shall be shut off during the fumigation activity and remain shut off until the ventilation required in Section 2603.6 is completed. 46.5.5.2 Notification. The AHJ and fire department shall be notified in writing not less than 48 hours before the building, structure or space is to be closed in connection with the utilization of any toxic or flammable fumigant. Notification shall give the location of the enclosed space to be fumigated or fogged, the occupancy, the fumigants or insecticides to be utilized, the person or persons responsible for the operation, and the date and time at which the operation will begin. Written notice of any fumigation or insecticidal fogging operation shall be given to all affected occupants of the building, structure or space in which such operations are to be conducted with sufficient advance notice to allow the occupants to evacuate the building, structure or space. Such notice shall inform the occupants as to the purposes, anticipated duration and hazards associated with the fumigation or insecticidal fogging operation. 46.5.5.2.1 Usage warning signs. Where fumigants and thermal insecticidal fogging products are used, approved warning signs bearing the skull and crossbones emblem with the warning DANGER! POISON GAS! KEEP OUT! shall be posted. Such signage shall be posted at all doors and entrances to the premises including interior rooms and areas, and along the exterior wall of the building or tenant space being fumigated at not less than 25 foot intervals. Such signage shall not be less than 7 inches in width and not less than 10 inches in height. 46.5.5.2.2 Warning signs. Approved warning signs indicating the danger, type of chemical involved and necessary precautions shall be posted on all doors and entrances to the premises, including interior rooms and areas. 46.5.5.2.3 Description and duration of posting. Signage shall be located at the exterior main entry and at the entries to those area being fumigated indicating the duration of the fumigation. Signage shall indicate the following information, written in English as the primary language, red lettering on a white background, and with the lettering height as described: 1. The date and time of the operation in lettering not less than 2 inches in height. 2. Type of chemical involved in lettering of not less than 1 inch. 3. Necessary precautions for the chemical used. 4. The name and address of the person responsible for the fumigation in lettering of not less than 1 inch in height. Page 23 of 65

5. A warning stating the occupied premises shall be vacated at least one (1) hour prior to beginning of operation and shall not be reentered until danger signs have been removed by the responsible party, in lettering of not less than 2 inches in height. 46.5.5.3 Breathing apparatus. Persons engaged in the business of fumigation or insecticidal fogging shall maintain and have available approved protective breathing apparatus. 46.5.5.4 Watch personnel. During the period fumigation is in progress a responsible watchperson shall remain on duty at the entrance or entrances to the enclosed fumigated space until after the fumigation is completed and the building, structure or space is properly ventilated and safe for occupancy. Sufficient watchers shall be provided to prevent persons from entering the enclosed space under fumigation without being observed. 46.5.5.5 Evacuation during fumigation. Occupants of the building, structure or space to be fumigated, except the personnel conducting the fumigation, shall be evacuated from such building, structure or space prior to commencing fumigation operations. 46.5.5.6 Sealing of building structures, and spaces. Paper and other similar materials that do not meet the flame propagation performance criteria of Test Method 1 or Test Method 2, as appropriate, of NFPA 701 shall not be used to wrap or cover a building, structure or space in excess of that required for the sealing of cracks, casements and similar openings. 46.5.5.6.1 Maintenance of openings. All openings to the building, structure or space to be fumigated or fogged shall be kept securely closed during such operation. 46.5.5.7 Venting and cleanup. At the end of the exposure period, fumigators shall safely and properly ventilate the premises and contents; properly dispose of fumigant containers, residues, debris and other materials used for such fumigation; and clear obstructions from gas-fired appliance vents. 46.5.6 Use of carbon dioxide for growing operations. Growing operations utilizing carbon dioxide shall comply with Section 46.8. 46.6 PROCESSING OR EXTRACTION OF MARIJUANA 46.6.1 Location. Marijuana processing shall be located in a building complying with the building code and this code. The marijuana extraction process shall be located in a room dedicated to the extraction process. The extraction room shall not be used for any other purpose including storage. 46.6.2 Staffing. The extraction process shall be continuously staffed by personnel trained in the extraction process, the transfer of LP-gas where applicable, and all emergency procedures. All staff training records shall be maintained on-site by the owner and made available upon request from the AHJ. 46.6.3 Systems, equipment and processes. Systems, equipment, and processes shall be in accordance with Sections 46.6.3.1 through 46.6.3.3.7.1 46.6.3.1 Application. Systems, equipment and processes shall include, but are not limited to vessels, chambers, containers, cylinders, tanks, piping, tubing, valves, fittings, and pumps. 46.6.3.2 General requirements. In addition to the requirements in Section 46.8 systems, equipment and processes shall also comply with Section 60.5.1.6, other applicable provisions of this code, the building code, and the NFPA 90A. 46.6.3.3 Additional requirements for marijuana extraction. In addition to the requirements of Section 46.6.3, marijuana extraction systems, equipment and process shall comply with this section. Page 24 of 65

46.6.3.3.1 General requirements. The requirements set forth in Section 60.5.1.6 shall apply to vessels, chambers, containers, cylinders, tanks, piping, tubing, valves, fittings, and pumps used in the extraction process. The use of ovens in post-process purification or winterization shall comply with Section 46.8.3.3.7. 46.6.3.3.2 Systems and equipment. Systems or equipment used for the extraction of marijuana/cannabis oils and products from plant material shall be performed using equipment that has been listed for the specific use. If the system used for extraction of marijuana/cannabis oils and products from plant material is not listed, then system shall have a designer of record. If the designer of record is not a licensed Professional Engineer, then the system shall be peer reviewed by a licensed Professional Engineer. In reviewing the system, the licensed Professional Engineer shall review and consider any information provided by the system s designer or manufacturer. For systems and equipment not listed for the specific use, a technical report documenting the design or peer review as outlined in 46.6.3.3.4.2 shall be prepared and submitted to the fire code official for review and approval for systems and equipment used for the extraction of marijuana/cannabis oils and products from plant material. The firm or individual performing the performing the engineering analysis for the technical report shall be approved by the fire code official prior to performing the analysis. 46.6.3.3.3 Change of extraction medium. Where the medium of extraction or solvent is changed from the material indicated in the technical report or as required by the manufacturer, the technical report shall be revised at the cost of the facility owner, submitted for review and approval by the AHJ prior to the use of the equipment with the new medium or solvent. If the original Engineer of Record is not available, then new Engineer of Record shall comply with Section 46.6.3.3.4.1. 46.6.3.3.4 Required technical report. The technical report documenting the design or peer review shall be submitted for review and approval by the AHJ prior to the equipment being located or installed at the facility. 46.6.3.3.4.1 Approval of the Engineer of Record. Where a technical report is required to be submitted for review and approval by the AHJ to meet the requirements of 46.6.3.3.2, the following items shall occur: 1. Prior to submittal of the technical report, the engineer shall submit educational background and professional experience specific to the review and approval of system, equipment and processes with like hazards of those associated with the marijuana extraction system to the AHJ. 2. Once the proof of qualifications are found acceptable by the AHJ, the Engineer of Record shall produce the technical report and the report shall be signed and sealed in accordance with respective State requirements. 46.6.3.3.4.2 Content of technical report and engineering analysis. All, but not limited to, the items listed below shall be included in the technical report. 1. Manufacturer information. 2. Engineer of Record information 3. Date of review and report revision history. 4. Signature page shall include: a. Author of the report b. Date of report c. Seal, date and signature of engineer of record performing the design or peer review. d. Date and signature of the engineer performing the engineering check of the report. The engineering check cannot be performed by the authoring engineer. Page 25 of 65

5. Model number of the item evaluated. If the equipment is provided with a serial number, the serial number shall be included for verification at time of site inspection. 6. Methodology of the design or peer review process used to determine minimum safety requirements. Methodology shall consider the basis of design, and shall include a code analysis and code path to demonstrate the reason as to why specific code or standards are applicable or not. 7. Equipment description. A list of every component and subassembly (clamp, fittings, hose, quick disconnects, gauges, site glass, gaskets, valves, pumps, vessels, containers, switches, etc.) of the system or equipment, indicating the manufacturer, model number, material, and solvent compatibility. Vendor cut sheets shall be provided. 8. A general flow schematic or general process flow diagram (PFD) of the process. Post-processing or winterization may be included in this diagram. All primary components of the process equipment shall be identified and match the aforementioned list. Operating temperatures, pressures, and solvent state of matter shall be identified in each primary step or component. A piping and instrumentation diagram (PID or PI&D) may be provided but is not required. 9. Analysis of the vessel(s) if pressurized beyond standard atmospheric pressure. Analysis shall include purchased and fabricated components. 10. Structural analysis for the frame system supporting the equipment. 11. Process safety analysis of the extraction system, from the introduction of raw product to the end of the extraction process. 12. Comprehensive process hazard analysis considering failure modes and points of failure throughout the process. This portion of the review should include review of emergency procedure information provided by the manufacturer of the equipment or process and not that of the facility, building or room. 13. Review of the assembly instructions, operational and maintenance manuals provided by the manufacturer. 14. Report shall include findings and observations of the analysis. 15. List of references used in the analysis. 46.6.3.3.5 Building analysis. If the technical report, or manufacturers literature indicate specific requirements for the location, room, space or building, where the extraction process is to occur, the Engineer of Record, as approved in 46.6.3.3.4.1 shall review the construction documents of such location, room, space or building and provide a report of their findings and observations to the AHJ. Analysis shall include: 1. Process safety analysis of the entire process from raw material to finished product. 2. Comprehensive process hazard analysis considering failure modes and points throughout the process. Should include review of emergency procedures as related to the equipment or process, and the facility. 46.6.3.3.6 Site Inspection. Prior to operation of the extraction equipment, if required by the AHJ, the Engineer of Record, as approved 46.6.3.3.4.1 shall inspect the site of the extraction process once equipment has been installed for compliance with the technical report and the building analysis. The Engineer of Record shall provide a report of findings and observations of the site inspection to the AHJ prior to the approval of the extraction process. The field inspection report authored by Engineer of Record shall include the serial number of the equipment used in the process and shall confirm the equipment installed is the same model and type of equipment identified in the technical report. Page 26 of 65

46.6.3.3.7 Post-process purification and winterization. Post-processing and winterization involving the heating or pressurizing of the miscella to other than normal pressure or temperature shall be approved and performed in an appliance listed for such use. Domestic or commercial cooking appliances shall not be used. The use of industrial ovens shall comply with Chapter 51. 46.6.3.3.7.1 An automatic fire extinguishing system shall not be required for batch-type Class A ovens having less than 3.0 cubic feet of work space. 46.7 Construction requirements 46.7.1 Location. Marijuana extraction shall not be located in any building containing a Group A, E or I occupancy. 46.7.1.1 Extraction room. The extraction equipment and process shall be located in a room dedicated to extraction. 46.7.2 Egress. Each marijuana extraction room shall be provided with at least one exit, swinging in the direction of travel provided with an automatic closer and panic hardware. 46.7.2.1 Facility egress. The marijuana extraction room shall not enter directly into an exit, exit passageway, horizontal exit or along the sole egress path from another portion of the building. 46.7.3 Ventilation. Each marijuana extraction room shall be provided with a dedicated hazardous exhaust system complying with Section NFPA 90A for all solvents other than water. The operation of the hazardous exhaust system shall be continuous. 46.7.4 Control area. Each marijuana extraction room shall be considered a single control area and comply with Section 60.4.2. 46.7.5 Ignition source control. Extraction equipment and processes using a hydrocarbon-based liquid or gas solvent shall be provided with ventilation rates for the room to maintain the concentration of flammable constituents in air below 25% of the lower flammability limit of the respective solvent. If not provided with the required ventilation rate, then Class I Division II electrical requirements shall apply to the entire room. 46.7.6 Interlocks. All electrical components within the extraction room shall be interlocked with the hazardous exhaust system and when provided, the gas detection system. When the hazardous exhaust system is not operational, then light switches and electrical outlets shall be disabled. Activation of the gas detection system shall disable all light switches and electrical outlets. 46.7.7 Emergency power 46.7.7.1 Emergency power for extraction process. Where power is required for the operation of the extraction process, an automatic emergency power source shall be provided. The emergency power source shall have sufficient capacity to allow safe shutdown of the extraction process plus an additional 2 hours of capacity beyond the shutdown process. 46.7.7.2 Emergency power for other than extraction process. An automatic emergency power system shall be provided for the following items when installed. 46.7.7.2.1 Required electrical systems. 1. Extraction room lighting 2. Extraction room ventilation system 3. Solvent gas detection system 4. Emergency alarm systems 5. Automatic fire extinguishing systems. 46.7.8 Continuous gas detection system. For extraction processes utilizing gaseous hydrocarbon-based solvents a continuous gas detection system shall be provided. The gas detection threshold shall be no greater than 25% of the LEL/LFL limit of the materials. Page 27 of 65

46.7.9 Liquefied-petroleum gases shall not be released to the atmosphere. 46.8 Carbon dioxide enrichment or extraction. Extraction processes or growing operations using carbon dioxide shall comply with the section. 46.8.1 Scope. Carbon dioxide systems with more than 100 pounds of carbon dioxide shall comply with Sections 46.8.1 through 46.8.1.8. This section is applicable to carbon dioxide systems utilizing compressed gas systems, liquefied-gas system, dry ice, or on-site carbon dioxide generation. Carbon dioxide systems shall not produce a concentration level of greater than 5,000 ppm in the room or area of use. 46.8.1.1 Permits. Permits shall be required as set forth in Section 1.12 46.8.1.2 Equipment. The storage, use, and handling of liquid carbon dioxide shall be in accordance with Chapter 63 and the applicable requirements of NFPA 55, Chapter 13. Insulated liquid carbon dioxide system shall have pressure relief devices in accordance with NFPA 55. 46.8.1.3 Carbon dioxide generation: Appliances used for generation of carbon dioxide shall comply with the NFPA 90A as a non-vented fuel-fired appliance. 46.8.1.4 Protection from damage. Carbon dioxide systems shall be installed so the storage tanks, cylinders, piping and fittings are protected from damage by occupants or equipment during normal facility operations. 46.8.1.4.1 Required protection. Where carbon dioxide storage tanks, cylinders, piping and equipment are located indoors, rooms or areas containing carbon dioxide storage tanks, cylinders, piping and fittings and other areas where a leak of carbon dioxide can collect shall be provided with either ventilation in accordance with Section 46.8.1.7 and an emergency alarm system in accordance with Section 46.8.1.8. 46.8.1.5 Carbon dioxide systems. Equipment, meters or gauges, shall be provided in each area where carbon dioxide is used or stored to indicate the level of carbon dioxide. The meters or gauges shall be calibrated and inter-connected to the gas supply solenoids located at the storage container or generator to limit a maximum level of carbon dioxide to not more than 5,000 ppm in the room or area of use. 46.8.1.5.1 Carbon dioxide system valving. The carbon dioxide system shall be provided with valves, located at the point of storage or generation, and that positively close in the event of loss of power, or in the event of an alarm activation. The valves shall be manually reset. 46.8.1.5.2 Carbon dioxide system piping. The piping system used to distribute the carbon dioxide within the building shall be of an approved type. Piping shall be labeled in accordance with Chapter 63. All shutoff valving of the piping system shall be labeled as such. 46.8.1.5.3 Pressure relief systems. Pressure relief devices shall be vented to the exterior of the building. 46.8.1.6 Signage. At the entrance to each area using or storing carbon dioxide, signage shall be posted indicating the hazard. Sign shall be durable and permanent in nature and not less than 7 inches wide by 10 inches tall. Sign shall bear the skull and crossbones emblem with the warning DANGER! POTENTIAL OXYGEN DEFICIENT ATMOSPHERE. NFPA 704 signage shall be provided at the building main entry and the rooms where the carbon dioxide is used and stored. 46.8.1.7 Ventilation. Mechanical ventilation shall be in accordance with NFPA 90A and shall comply with all of the following: 1. Mechanical ventilation in the room or area shall be at a rate of not less than 1 cubic foot per minute per square foot. 2. Exhaust shall be taken from a point within 12 inches of the floor. Page 28 of 65