Monthly Oil and Gas Production and Disposition Statements Error Notices

Similar documents
Signing Up... 1 Logging in for the First Time... 2 The Search Panel... 3

STTM INTERFACE PROTOCOL

Cent$ible Power Users Manual

[ [ ADMIN PANEL USER GUIDE

Friends and Family Test

Using the Room View Window

Ion Gateway Cellular Gateway and Wireless Sensors

Browser Compatibility Update

City of Regina Alarm Bylaw

Xeriscape Rebate Program Manual

STRUCTURE FIRE REPORT

Outdoor Fire Report - Instructions OUTDOOR FIRE REPORT

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.

Byrd Barr Place PSE HELP Program:

Integration Test Plan

Management Practices: Fire Protection Impairments November 2015

Contents. Glossary

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

How to Configure the Alarm Action Outgoing Cell Call MultiLogger Application Note #14

Managing Network Alarms and Events

System description LG 66E-TL11 with time lock function

MONTGOMERY COUNTY RULES GOVERNING ALARMS SECTION 1. PURPOSE SECTION 2. DEFINITIONS

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Standard VistaNET GCC Software: 803V029-(VER)(REV)

LineGuard 2300 Program User Manual (FloBoss 107)

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

ALARM RESPONSE POLICY

Membership Scanning your card or entering your card number when in store or shopping Online Earning Member Benefits

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Watchguard WGAP864 User Manual

Monty s guide to paying your rent

Business Process and Procedures Workstream. Event Log Collection, Processing & Delivery process (BP05)

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Getting Started with Live Exceptions

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Monty s guide to paying your rent

3 User s settings. 3.3 Internal clock setting

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

This chapter shall be known as the "City of Bayfield Alarm Systems Ordinance."

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

CITY OF SURREY BY-LAW NO SURREY SECURITY AND FIRE ALARM BY-LAW,

CITY OF POWELL RIVER

IDS816 User Manual H Issued January 2009

SPECTRUM Alarm Notification Manager (SANM)

Avigilon Control Center 5 System Integration Guide

Elderly Care Alarm System

Monitor Alarms and Events

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

ACU DEVELOPMENT PLAN OBJECTION RESPONSE

Frequently Asked Questions

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Appendix F. Wisconsin. Department of Natural Resources. Contaminated Site Listings. Village. Park Ridge

JA-63 Profi User manual

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

Procedures for Preparing and Receiving PUF Canisters and Filters

Automatic Fire Alarm Service Provider Computer Interface Specification for Extended Alarm Protocol (XAP) Devices

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Residential Structure Fire Deaths in BC, BC Coroners Service Ministry of Justice

ADT Select User Manual. 131 ADT ACN

Sound Practice No.10. Achieving Fire Safety in the City of Makati

Well Abandonment Requirements

D3D Wi-Fi GSM Smart Alarm System -User Manual

Monitor Alarms and Events

Australian/New Zealand Standard

IntelliSync Thermostat / Mobile App Frequently Asked Questions

GB-DAS. Installation and user manual DEVIreg 850 controller

WESFARMERS REINSTATES DIVIDEND INVESTMENT PLAN

Installing ProSeries software for stand-alone use

PodView Level Indicator LI40 Series Manual

September 30, Dear Fire Suppression System Contractor/Designer:

Table of Contents. Appendix A Special Characters 31

THE REGIONAL MUNICIPALITY OF HALTON POLICE SERVICES BOARD BY-LAW

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Waters 2695D Separations Module

FINANCIAL SERVICES COMPENSATION SCHEME (SINGLE CUSTOMER VIEW SUPERVISION AND OTHER AMENDMENTS) INSTRUMENT 2009

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

Residential Demand Controller Program

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ULTRASONIC OIL LEVEL MONITOR & ALARM

2200 and 2200L ALARM CONTROL SYSTEMS

Using ANM Mobile CHAPTER

FEB 15 Rev C

TABLE OF CONTENTS. Your Northwood Intouch Unit (Diagram)...1. How to use your Emergency Response System... 2

1.3 REFERENCE STANDARDS

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

Annex 1. of 19 July Page 1 of 10

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Simplex Panel Interface Guide

Processing Water Heater Refunds

MINUTES OF TOWN BOARD MEETING HELD ON OCTOBER 18, 2017 AT 7:00 PM AT TOWN HALL, ONE OVEROCKER ROAD POUGHKEEPSIE, NEW YORK

DIRECT CONNECT RESIDENTIAL ALARM SYSTEM Application Form

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

AT60 AUTO DIALLER User Guide

Transcription:

Information Letter 2007-03 www.gov.bc.ca/sbr ISSUED: November 2007 Monthly Oil and Gas Production and Disposition Statements Error Notices If you operate a production facility, you need to be aware of a change in how the Ministry of Small Business and Revenue assists you with correcting errors in your Monthly Production Statement (S1) and Monthly Disposition Statement (S2). Errors in the S1 and S2 can prevent the ministry from processing the information you provide. Currently, if there is an error in your S1 or S2, the ministry contacts you and suggests what you can do to correct the error. However, this can take time. Therefore, to reduce the delay, effective December 1, 2007, the ministry will send error notices to you by e-mail shortly after the S1 and S2 due dates. To assist you with the error notices, this letter provides: general information about how the Oil and Gas Commission (OGC) and the ministry manage well and facility information, and a list of possible errors, explanations of what they mean, and information about what you can do to correct them. General Information Errors can occur when the information you report on your S1 and S2 is different from the information in the OGC s or the ministry s system. Therefore, understanding how the OGC and the ministry manage well and facility information may help you to correct the errors. Well Events The status of a well event has three parts. 1. Fluid type (oil, gas, water, gas cap, solvent or undefined). 2. Mode (active, gas testing, completed, suspended or abandoned). 3. Operation type (production, disposal, injection, observation, source storage or undefined). PO Box 9328 Stn Prov Govt Victoria BC V8W 9N3

To report production for a well event, the mode must be active or gas testing and the operation type must be production in the OGC s system. The OGC s System The OGC has a record of all well events regardless of their status or product. The OGC establishes a well event in its drilling event tables when it receives a drilling report for the well event. The OGC establishes a well event in its completion event tables when it receives and reviews a completion report for the well event. The OGC determines the status of a well event from a Notice of Commencement or Suspension of Operations (BC11). The Ministry s System The ministry only enters well events that produce oil or natural gas into its royalty management system. This means the ministry enters a well event into its system when the ministry receives a BC11 showing that the fluid type is oil or gas, that the mode is active or gas testing and that the operation type is production. Once the ministry enters a well event in its system, the well event is kept in its system even if the status of the well event changes. Facilities The OGC s system The OGC establishes a facility in its system when it approves an Application for Production Facility (BC20). When the OGC establishes a facility, it may be flagged as a reporting facility. A reporting facility is a battery or test facility connected to at least one well that is being tested or is producing. A facility that is not flagged as a reporting facility is known as a physical facility. You do not have to file the S1 and S2 for physical facilities. A well is connected to a reporting facility in the OGC s system when the OGC approves an Application for Well or Facility to Facility Linkage (BC21). The OGC checks the reporting facility codes provided on the BC11 to make sure those well-to-facility connections are the same as the connections approved on the BC21. The Ministry s System The ministry establishes a facility in its system when the ministry receives the first BC11 for a well event that is connected to that facility. In this situation, Monthly Oil and Gas Production and Disposition Statements Error Notices Page 2 of 10

the ministry also uses the BC11 to establish the well-to-facility connection. In all other situations, the ministry uses the BC21 to establish or change well-to-facility connections. As the ministry only enters a facility into its system when it receives a BC11 indicating there is a producing well event connected to that facility, there may be facilities that are classified as reporting facilities in the OGC s system that are not in the ministry s system. Error Messages Overview Some errors occur when you report an incorrect Unique Well Identifier (UWI) or facility code on your S1 or S2. You can find valid UWIs and reporting facility codes on the ministry s website at http://www.sbr.gov.bc.ca/business /Natural_Resources/natural_resources.htm Once you are at the website: you can find valid UWIs, by clicking on Oil and Gas Royalties and Freehold Production Tax, then Oil and Gas Royalties and Taxes Online, then UWI Query, and then entering the Well Authorization (WA) number, and you can find reporting facility codes, by clicking on Oil and Gas Royalties and Freehold Production Tax, then Oil and Gas Royalties and Taxes Online, then Facility Codes, and then searching for the correct reporting facility using the various search parameters that are available. You can also contact the ministry for assistance by e-mail at Oil&GasRoyaltyQuestions@gov.bc.ca or by phone 250 952 0192 in Victoria, or toll free at 1 800 667 1182. When you correct an error, you may need to notify the ministry of the correction you have made, or provide the ministry with other information. Please use the e-mail address or phone number listed above to contact the If you need to amend your S1 or S2 to correct an error, either send the amended report to the above e-mail address, or notify the ministry by e-mail or phone. This may prevent the ministry from issuing unnecessary penalties. If you correct some of the well events reported on your S1 and you submit the amendment on paper, only include the amended well events. If your system will only allow you to resubmit the entire S1, please highlight the amended well events. Monthly Oil and Gas Production and Disposition Statements Error Notices Page 3 of 10

Complete List of Possible Errors ** ERROR 0019 ** This S2 facility is not an OGC reporting facility. The indicated facility has a valid facility code, but is not considered by the OGC to be a reporting facility. A reporting facility is a battery or test facility connected to at least one well that is being tested or is producing. Submit the S2 again with the correct reporting facility code and ask the ministry to delete the previous S2. You can find a list of reporting facilities on the ministry s website or you can contact the ministry for assistance. ** ERROR 0150 ** Production period is before 198904. ** ERROR 0152 ** This UWI has never been a producing well event. ** ERROR 0233 ** This UWI is not in COMPLETION_ EVENT in the OGC system. The production period you reported on the indicated S1 or S2 is before April 1989. The systems that the ministry and the OGC use cannot process information before April 1989. The indicated well event exists in the OGC s system, but not in the ministry s system. You reported production for the indicated well event on an S1, but the UWI is not in the OGC s completion event records for any event sequence. It is only in the OGC s drilling records. See if you reported the correct production period. If it was not correct, submit the report again with the correct period and notify the If it was correct, contact the See if you reported the correct well event on the S1. If it was not correct, submit the S1 again with the correct well event and notify the If it was correct, submit a BC11 to activate the well event. If you have already submitted a BC11 with the appropriate status, no further action is required. See if you recorded the correct UWI on the S1. If it was not correct, submit the S1 again with the correct UWI and notify the If it was correct, see if you have filed a BC11 to activate the well event. If not, submit a BC11. This will result in essential completion information being entered in the OGC s completion event records. You should also ensure that a Completion/Workover Report for the well event is filed with the OGC. If you have filed a BC11 and a Completion/Workover Report, nothing more needs to be done. Monthly Oil and Gas Production and Disposition Statements Error Notices Page 4 of 10

** ERROR 0234 ** No status information for this UWI and production period. ** ERROR 0237 ** Cannot report condensate production to an oil well. ** ERROR 0238 ** Cannot report oil production for a gas well. ** ERROR 0241 ** Cannot report oil or gas production to a water well. ** ERROR 0242 ** Status for this UWI is 'SUSPENDED'. The indicated well event is valid, but status information for the well event is not in the OGC s system for the reported period. You reported condensate production on an S1 for the indicated well event while the OGC s records show oil as the fluid type of that well event for the reported period. You reported oil production on an S1 for the indicated well event while the OGC s records show gas as the fluid type of that well event for the reported period. You reported oil, condensate, or gas production on an S1 for the indicated well event while the OGC s records show water as the fluid type of that well event for the reported period. You reported oil, condensate or gas production on an S1 for the indicated well event, but the mode of that well event is suspended for the reported period in the OGC s records. See if you reported the correct production period on the S1. If it was not correct, submit the S1 again with the correct period and notify the If it was correct, submit a BC11 to create the required status information or to amend the effective periods as required. See if the fluid type is correct. If the fluid type is not correct, submit a BC11 to change the fluid type to gas for the reported period. If the fluid type is correct, submit the S1 again with the volume reported as oil production instead of condensate production and notify the See if the fluid type is correct. If the fluid type is not correct, submit a BC11 to change the fluid type to oil for the reported period. If the fluid type is correct, submit the S1 again with the volume reported as condensate production instead of oil production and notify the See if the fluid type is correct. If the fluid type is not correct, submit a BC11 to change the fluid type to oil or gas for the reported period. If the fluid type is correct, submit the S1 again with the oil, condensate or gas volume reported for the correct well event with the required fluid type and notify the See if the mode is correct. If the mode is not correct, submit a BC11 to change the mode to active for the reported period. If the mode is correct, submit the S1 again with the production volumes reported for the correct well event with an active mode and notify the ** ERROR 0265 ** The sum of the measured and prorated Notify the ministry of the correct Monthly Oil and Gas Production and Disposition Statements Error Notices Page 5 of 10

Hours of production for this UWI exceed 744 (31days*24hrs). hours you reported on an S1 for the indicated well event is greater than 31 days times 24 hours per day. number of hours. ** ERROR 0332 ** Hours of production for this UWI exceed hours in this period. ** ERROR 0419 ** This UWI is not in DRILLING_EVENT in OGC system. The sum of measured and prorated hours you reported on and S1 for the indicated well event is less than 744, but more than the actual number of hours in the reported month. The reported month has 30 days, but you reported more than 720 (30 x 24) hours, or the month is February and you reported more than 672 hours, or if it is a leap year, more than 696 hours. You reported production for the indicated well event on an S1, but the UWI is not in the OGC s completion event records or drilling records for any event sequence. The location part of the identifier does not match any location in the OGC s records. Notify the ministry of the correct number of hours. See if you recorded the correct UWI on the S1. If it was not correct, submit the S1 again with the correct UWI and notify the If it was correct, see if the location of the well event is correct. If you are unsure about what the UWI location should be, refer to the targeted bottom-hole location on the WA. You can also find valid UWI locations on the ministry s website. Submit the S1 again with the correct UWI and notify the If the UWI Query shows that the UWI you used is valid, this means the OGC entered completion information after you filed the S1. Ask the ministry to process the S1 again with the same UWI. ** ERROR 0420 ** Completion event sequence is not valid for this UWI s location. (to continue, see page 7) You reported production for the indicated well event on an S1 and the well event is not in OGC s completion event records, but there is a UWI in the OGC s completion event records with the same location and a different event sequence. The location part of the identifier is probably correct, but the event sequence is not. See if you recorded the correct UWI on the S1. If it was not correct, submit the S1 again with the correct UWI and notify the If it was correct, see if the event sequence is correct. You can find valid event sequences for a location on ** ERROR 0420 ** the ministry s website. When you find the correct event sequence, submit the (continued from page 6) S1 again with the correct UWI and Monthly Oil and Gas Production and Disposition Statements Error Notices Page 6 of 10

notify the If the UWI Query shows that the event sequence you used is valid, this means the OGC entered completion information after you filed the S1. Ask the ministry to process the S1 again with the same UWI. ** ERROR 0421 ** DISPosal in OGC ** ERROR 0422 ** INJection in OGC ** ERROR 0423 ** OBServation in OGC but must be ** ERROR 0424 ** SouRCe in OGC ** ERROR 0425 ** STORage in OGC You reported oil, condensate or gas production for the indicated well event, but the operation type of that well event is not production for the reported period in the OGC s records. See if the operation type is correct. If the operation type is not correct, submit a BC11 to change the operation type to production for the reported period. If the operation type of that well event is correct, submit the S1 again with the production volumes reported for a different well event with an operation type that is production and notify the ** ERROR 0426 ** Mode Code is COMPleted in OGC ACTive. ** ERROR 0427 ** Mode Code is SUSPended in OGC ACTive. You reported oil, condensate or gas production for the indicated well event, but the mode of that well event is not active or gas testing for the reported period in the OGC s records. ** ERROR 0428 ** Mode Code is unknown in OGC ACTive. You reported oil, condensate or gas production for the indicated well event, but the mode of that well event is not active or gas testing for the reported period in the OGC s records. See if the mode is correct. If the mode is not correct, submit a BC11 to change the mode to active or gas testing for the reported period. If the mode of that well event is correct, submit the S1 again with the production volumes reported for a different well event with a mode that is active or gas testing and notify the See if the mode is correct. If the mode is not correct, submit a BC11 to change the mode to active or gas testing for the reported period. If the mode of that well event is correct, Monthly Oil and Gas Production and Disposition Statements Error Notices Page 7 of 10

submit the S1 again with the production volumes reported for a different well event with a mode that is active or gas testing and notify the ** ERROR 0429 ** UNDefined in OGC ** ERROR 0430 ** unknown in OGC ** ERROR 0432 ** This S2 facility is not in the OGC system. ** ERROR 0433 ** This S2 facility is not effective for this production period. ** ERROR 0435 ** This S1 facility is not in the OGC system. You reported oil, condensate or gas production for the indicated well event, but the operation type of that well event is not production for the reported period in the OGC s records. The indicated facility code is not in the OGC s system. The indicated facility was not operating during the reported period in the OGC s records. The indicated facility code is not in the OGC s system. It is not a valid code for any physical or reporting facility. See if the operation type is correct. If the operation type is not correct, submit a BC11 to change the operation type to production for the reported period. If the operation type of that well event is correct, submit the S1 again with the production volumes reported for a different well event with an operation type that is production and notify the Submit the S2 again with the correct facility code and ask the ministry to delete the S2 with the invalid code. See if you reported the correct production period. If it was not correct, submit the S2 again with the correct period and ask the ministry to delete the S2 with the incorrect period. If it was correct, contact the Senior Facilities Officer at the OGC by e-mail at S1S2Errors.Resolution@gov.bc.ca or by phone at 250 261-5760 to change the effective date of the facility. Submit the S1 again with the correct reporting facility code and ask the ministry to delete the S1 with the invalid code. You can find a list of reporting facilities on the ministry s website or you can contact the ministry for assistance. ** ERROR 0436 ** This S1 facility is not a reporting facility in the The indicated facility is in the OGC s system, but not in the ministry s system. The facility has been established in the OGC s system and flagged as a reporting facility, but no BC11 has been filed with the required status (mode is Submit a BC11 indicating the required status and notify the Monthly Oil and Gas Production and Disposition Statements Error Notices Page 8 of 10

active or gas testing, fluid type is oil or gas, and operation type is production). ** ERROR 0437 ** This S1 facility is not connected to this UWI. ** ERROR 0438 ** This S1 facility is not connected to this UWI in this period. (to continue, see page 10) The indicated UWI is not connected to the facility on the S1 for any reporting period in the OGC s system. The indicated UWI is, or was, connected to the reported facility in the OGC s system, but not in the reported period. See if the well event was connected to the reported facility. If it was not connected, submit an amended S1 and an amended S2 for the facility without the well event and notify the If the well event was connected to a different facility, submit an amended S1 and an amended S2 for that facility with the well event added to those reports and notify the If the well event was connected to the reported facility during the reported period, send a BC21 to the OGC to link the well event to the reporting facility. Specify an effective date on the BC21 that is on or before the reported period. Send the BC21 to the attention of the Senior Facilities Officer at the OGC. See if the well event was connected to the reported facility during the reported period. If it was not connected, submit an amended S1 and an amended S2 for the facility without the well event and notify the If the well event was connected to a different facility during the reported period, submit an amended S1 and an amended S2 for that facility with the well event added to those reports and notify the ** ERROR 0438 ** (continued from page 9) If the well event was connected to the reported facility during the reported period, send a BC21 to the OGC to change the effective month of the linkage. Send the BC21 to the attention of the Senior Facilities Officer at the OGC. Monthly Oil and Gas Production and Disposition Statements Error Notices Page 9 of 10

Further Information If you have any questions, please call us at 250 952 0192 in Victoria, or toll free at 1 800 667 1182, or e mail your questions to Oil&GasRoyaltyQuestions@gov.bc.ca Monthly Oil and Gas Production and Disposition Statements Error Notices Page 10 of 10