The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Similar documents
Specifications Minimum Typical Maximum Unit

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-1-LCD Temperature Data Logger with LCD

ELMTEC. Kattreppeln Königslutter / /

EL-OEM-3 OEM Packaged Voltage Data Logger

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EL-USB-TC Thermocouple Data Logger with USB Interface


EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Data Logging Solutions

EL-OEM-3 OEM Packaged Voltage Data Logger

EasyLog Data Logger Series

EasyLog Data Logger Series

Temperature & Humidity Monitoring For Museums & Heritage Product Guide.

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

iminiplus PDF User Guide Version 2.0

HOBO U14 Data Logger User Manual

UTRED day Logger with display

USER MANUAL USB Multi-Function Datalogger Model RHT35

PRODUCT SPECIFICATION

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Introduction. OM-THA2

Wet Bulb Thermo-Hygrometer Datalogger

Follett Performance Plus

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

User Manual. Humidity-Temperature Chart Recorder. Model RH520

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

MIRADOR Real Time Monitoring

CDL 210. Operating manual. CO2 Logger. Best.-Nr

LogTag TICT - is0 Tag

UTRED30-WiFi. 30 day WiFi Logger with display

DataSheet. Thermocouple Logger

DataSheet. Thermocouple Logger

EASYLOG Temperature Label Series

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

Refrigerator/Freezer Thermometer

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

2014, TempSen Electronics Company

Refrigerator/Freezer Thermometer

SCAN200E USER S MANUAL

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Model: Available in : Sapphire Black and Glacier White. 1 Series

What's new in LogTag Analyzer 2.8

ISO New Product Catalog. Addendum 2014 TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

Halton SAFE / 7.14 user guide and installation instructions

Batt-Safe Battery String Monitoring System

GMH 285 / GMH 285-BNC

Dryer Controller M720

Water Tank Level Monitor

User Manual. Dryer Controller M720

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Sirius Technologies, Inc.

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

THX-DL Data Logger USER & INSTALLATION MANUAL V

Exceptional data integrity. Complete peace of mind.

data logger DL200H DL200D DL200L

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

TV2 Room Pressure Monitor Quick Start Guide

Temperature Monitoring

AirTest Technologies Inc.

Vokèra OpenTherm 711 with external sensor connected

USRIC-8(M) USB PDF Temperature Recorder. Product User Guide. LogTag Recorders Ltd

Commodity Description

CBI-064. User Manual. Caddx to KNX-BUS Interface

End To End Optical Beam Smoke Detector. Additional Information

Cold chain monitoring technologies. Facility monitoring

Software Version 2.01 LEVEL MONITOR MODEL 220

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Sensor Cloud User Manual

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Indoor/Outdoor Temperature Alert

Temperature Monitoring System. Specifications

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Manage Alarms. Before You Begin CHAPTER

NYS Vaccines for Children (VFC) Program Fridge-Tag 2L Data Logger: Implementation and User Guide

Monitoring Operator Guide. Access Control Manager Software Version

INSTALLATION INSTRUCTIONS

L. Terminal block Connecting Label:

HERCULES 6 GRAPHICS SYSTEM

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Transcription:

High Accuracy Temperature Probe Data Logger with LCD Screen, -40 to +125 C (-40 to +257 F) measurement range Stores over 32,000 readings EasyLog 21CFR software available as a free download Logging rates between 1 second and 12 hours High contrast LCD, with four digit temperature display function Immediate, delayed and push-to-start logging User-programmable alarm thresholds Use as part of a 21CFR Part 11 compliant system This standalone data logger measures and stores more than 32,000 temperature readings over a -40 to +125 C (-40 to +257 F) range with a resolution of 0.1 C (0.2 F). The user can easily set up the logger and view downloaded data by plugging the data logger into a PC s USB port and using the free EasyLog 21CFR software. Data can then be graphed, printed and exported to other applications for detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11. The high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored values for temperature. The data logger is supplied with a lithium metal battery which typically gives two years logging life. SPECIFICATIONS Measurement range Accuracy (logger error) -40 to +125 C (-40 to +257 F) ±0.1 C (±0.2 F) Accuracy (probe) See Temperature Probe Accuracy on page 4 Resolution (display) Resolution (data) Logging rate Operating temperature range Battery Life 0.5 C (1 F) 0.1 C (0.2 F) Readings 32,510 User selectable between 1 second & 12 hours -35 to +80 C (-31 to +176 F) (data logger only) 2 years (at 25 C and 1 minute logging rate, LCD on) Dimensions 135 x 24 x 21mm (5.31 x 0.94 x 0.82 ) ACCESSORIES EL-PROBE-EXTENDER- 5.0M-TP EL-PROBE-EXTENDER- 10.0M-TP EL-PROBEA-3.0M-TP- GLY INCLUDED IN THE BOX BAT 3V6 1/2AA EL-PROBEA-3.0M-TP+ EL-LCD-WALL BRACKET Probe extension (5.0m) Probe extension (10.0m) High accuracy thermistor probe Glycol pot Replacement battery High accuracy thermistor probe Mounting Bracket CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information, please see.

STORE DATA IN COMPLIANCE WITH THE REGULATIONS OF 21CFR PART 11 Easy to install and use, Lascar s EasyLog 21CFR software is compatible with all latest versions of Windows (7, 8 & 10 - both 32-bit & 64-bit) and is available as a free download from www.easylog21cfr.com. All data collected from the logger and associated audit trails are stored in an encrypted format which cannot be edited. CONTROL YOUR LOGGER Users can configure their loggers with the following parameters: Logger name Temperature measurement parameter ( C or F) Logging rate (user selectable between 1 second and 12 hours) High and low alarms for temperature Immediate and delayed logging start Probe type Once users have recorded data, the built-in graphing software allows them to graph and annotate their data, or export it to Excel, PDF or jpeg formats. CONTROL YOUR DATA EasyLog 21CFR software ensures digital security and compliance: Assign individual users with specific permissions Full software & session data audit trails Receive email alerts for failed log in attempts Digital signatures added to all reports Add comments to specific readings For more information, and to download the latest version of the software free of charge, visit www.easylog21cfr.com Issue 2 05/2016 N.R Page 2 of 5

DISPLAY STATUS INDICATION The EL-21CFR-TP-LCD+ features a high contrast LCD which shows logged temperature values using seven segment numbers, along with annunciators. The LCD can also show information regarding the loging status. The LCD shows three different recorded readings, which can be cycled through using the built-in push button. The most recent logged temperature, maximum logged temperature and minimum logged temperature can be displayed. To increase battery life it is possible, via the software, to turn off the display or have it active only after pressing the button. Reading Temperature scale symbols Maximum/Minimum logged value symbol Display Logger Status Explanation Delayed Start This is shown when the button is pressed and the logger is set to start at a specific date and time Push to Start This will flash when the logger is setup for Push to Start logging Logging Stopped Clear Max/Min Probe has been disconnected This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after a short period If the logger has not been set to log and the button is pressed, three dashes are displayed for a short period This indicates that the maximum and minimum stored values have been cleared after pressing the button for a few seconds. This will not work if the probe is disconnected or the logger is connected to a USB port The flashing message Prob, followed by a number or letter, will be displayed if the logger is logging and the probe becomes disconnected. The number/letter confirms the type of probe that should be connected Issue 2 05/2016 N.R Page 3 of 5

LED STATUS INDICATION The EL-21CFR-TP-LCD+ features two LEDs: The first LED flashes red to indicate that the EL-21CFR-TP-LCD+ is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. The second LED flashes green to indicate that the EL-21CFR-TP-LCD+ is not in an alarm condition. Using EasyLog 21CFR Software it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This Hold feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. Hold is enabled by default, and can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. Using the control software it is possible to set a delayed alarm. In this mode the logger has to see multiple consecutive alarms before being activated. Green single flash (every 30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start) Green single flash (every 10 seconds) The data logger is currently logging. No alarm Red single flash (every 10 seconds) The data logger is currently logging. Low alarm Red double flash (every 10 seconds) The data logger is currently logging. High alarm Green single flash (every 20 seconds) The data logger is currently logging. Low battery Red single flash (every 20 seconds) The data logger is currently logging, however the battery is running low. Low alarm Red double flash (every 20 seconds) The data logger is currently logging, however the battery is running low. High alarm Green double flash (every 20 seconds) The data logger is full and has stopped logging Red & Green single flash alternately (every 20 seconds) The data logger is full and has stopped logging. High or low alarm No LEDs flash The data logger is stopped, the battery is empty or there is no battery Red Triple flash (every 10 seconds) The data logger is currently logging, but the probe has been disconnected Issue 2 05/2016 N.R Page 4 of 5

THERMISTOR PROBE The probes supplied with the EL-21CFR-TP-LCD+ uses a precision thermistor to sense the temperature. Alternative lengths and probe options are available. The probe type is selected in the control software and should match the label on the probe in use. Alternatively, the probe length may be extended by the use of a suitable extension cable. We recommend twisted pair with high quality 3.5mm jack socket/plugs for best results. The thermistor is externally isolated from the probe tip. THERMISTOR PROBE ACCURACY Supplied Type A Thermistor Probe Part number: EL-PROBEA-3.0M-TP+ BATTERY INFORMATION Replacement We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries. The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and will not resume until the battery is replaced and the logger restarted by the EasyLog 21CFR Software. Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB port for extended periods will cause some of the battery capacity to be lost. Passivation If left unused for extended periods of time lithium metal batteries, including those used in the EasyLog range of data loggers, naturally form a non-conductive internal layer preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected. WARNING Handle lithium metal batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Issue 2 05/2016 N.R Page 5 of 5