VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

Similar documents
Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Series VENTS VUT R WH ЕС

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Duct electric heater with temperature controller

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

NKW. Heater series HEATERS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

KOMFORT EC DB Suspended heat recovery air handling units

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

USER S MANUAL. VKP Series INLINE FAN

CENTRIFUGAL FANS user's manual. model VENTS VK.

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

SINGLE-ROOM VENTILATION. for schools and public spaces

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

HEAT RECOVERY AIR HANDLING UNIT

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

INTELLIGENT AXIAL FAN user's manual

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Catalogue section. Contents Quick fan selection Quick selection of air handling units About us Ventilation in our life...

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

AXIAL FANS USER S MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

Calm. Service Instructions

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

TopMaster Air Handling unit. Technical data

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Caution: The fans must not be used in bath or shower enclosures.

CENTRIFUGAL CEILING EXTRACT FAN

Wind. Service instruction

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

ENERVEX RSV CHIMNEY FAN

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

5 year fan housing and motor warranty

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

USER S MANUAL DN-2. Drain pump

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Turbo. Service Instructions

COMMERCIAL VENTILATION

100 FLUEBOOST

CENTRIFUGAL CEILING EXTRACT FAN

Installation manual Mini Comfort 50 S/L 07/ V EN

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Axial fans The right fan for every house

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

Indirect Gas-Fired Make-Up Air

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

DanVex AD-550 Adsorption air dehumidifier. Operation manual

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

TURBO HOODS. Product Brochure

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

AC Backward Curved Motorized Impellers

Air handling units with an integrated heat pump and rotary heat exchanger

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

FLUEBOOST. flueboost 350 gas fire model

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

BATHROOM EXTRACT FANS SILENT-100 Series

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

UV-TURBO HOODS. Product Brochure

DanVex AD-200 Adsorption air dehumidifier. Operation manual

ENERVEX GSV GREASE FAN

Q (m3/h)

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

Transcription:

CHIMNEY CENTRIFUGAL FANS Series Design The fan casing is made of galvanized steel and equipped with heat- and sound insulation of fireresistant mineral wool. The casing is perforated for the internal air circulation and motor cooling. The temperature regulator is used for setting the temperature level for the fan switching on and off. Fan startup is effected within the range of 0 С to +90 С depending on the air temperature generated inside the fireplace heat-exchanger. Mounting The fireplace fans are designed for connection with round air ducts. The fans can be mounted in any position with respect to the airflow direction indicated with a pointer on the casing. Access for the fan maintenance shall be reserved. Warm air feed ducts shall be laid between the fan and each of the heated rooms. Concealed air ducts system with forced warm air circulation allows saving useful space in the house and fits to the house design. Chimney centrifugal fan for house heating system management using heat of chimney or fireplace. It can be also used as a base for backup heating source. Applications Chimney fans for hot air distribution allow creating fully-featured air heating system based on a fireplace. Such system is the perfect solution for heating of seasonal houses that serve as a second residence during winter time and provides fast and efficient hot air distribution from chimney to other premises. Used for air distribution with the air tempreature range 0 С to +150 С. Motor The fans are supplied with single-phase motors for operation in 230/50Hz power supply network. Insulation Class F. The motors have built-in overheating protection with automatic restart. The motor is placed off-airflow and is equipped with forward-curved impeller blades as well as ball bearings for long service life. The fan models marked are equipped with asynchronous motors and extra impeller for air blowing-off and cooling. The fan motors models marked are equipped with the external rotor. max fans are equipped with the high powered external rotor motor. The fan motors models marked Duo have two speeds and equipped with the external rotor. Speed control Both smooth and step fan control is performed by means of the thyristor or autotransformer (Models, ). The fan speed is controlled within the range of 0 to 100%. Duo fan speed is controlled by means of the speed switch. Accessories FFK removable G3 metal filter-box for boosted air purification. The filter is connected to the fan casing by lock-latches to provide easy removal of the filter for cleaning. KFK removable metal mixing chamber with incorporated thermal control damper and G3 filter for boosted air purification. The mixing set is fixed to the fan casing by means of lock-latches to ensure easy removal for cleaning. Fan configuration with KFK mixing chamber provides cool air supply into the mixing chamber when the operating temperature exceeds 90 С. Such configuration also allows hot air withdrawal while the fan motor is not running. GFK gravitation backdraft damper to prevent air back draft in the system. Such fan configuration that includes KFK mixing set and GFK backdraft damper ensures fan motor overheating protection based on BY-PASS actuation, in particular when the motor is not running due to no power supply. The fans with such configuration enable backdraft damper shutting and hot air distribution to other premises through ventilation ducts when the motor is not running. Designation key: Fan series Duct connection diameter Motor Modifications 125; 140; 150; 160 with external rotor; max high powered external rotor motor; Duo two-speed with external rotor _ is equipped with temperature regulator by default; T1 without temperature regulator Accessories Accessories page 349 page 349 MFK FFK KFK GFK ТS-1-90 100

WWW.VENTILATION-SYSTEM.COM 1 fans operation principle. When the temperature in the fireplace hood reaches the set value the fan turns automatically on and distributes hot air from the fire hood place to other premises. It turns off when the temperature falls down below the set value. 2 Operation principle of fan with FFK box filter + = FAN SERIES FFK When the temperature in the fireplace hood reaches the set value the fan turns automatically on and distributes the hot air purified by FFK filter from the fire hood to other rooms. It turns off when the temperaure falls down below the set value. 3 Operation principle of fan with KFK damper + = When the temperature in the fireplace hood reaches the set value the fan turns automatically on and distributes hot air from the fire hood place to other rooms. It turns off when the temperature falls below the set value. The fan with KFK mixing set provides additional hot air supply of hot air to the mixing chamber when the temperature of distributed air exceeds 90 С and as well as the withdrawal of the hot air when the motor is not running. КАМ KFK 4 Operation principle of fan with KFK damper and GFK backdraft damper with BY-PASS system + + = КАМ KFK GFK When the temperature in the fireplace hood reaches the set value the fan turns automatically on and distributes hot air from the fire hood place to other premises. It turns off when the temperature falls below the set value. BY-PASS system ensures overheating protection, i.e. the fan does not operate at no power supply. It closes the damper and boosts hot air through the opened gap to other premises. BY-PASS regulates the temperature by mixing chamber damper opening providing the cold air supply if the air supplied to the fan is too hot. VENTS. Industrial and commercial ventilation 09-2011 101

CHIMNEY CENTRIFUGAL FANS Installation and operation of fans with FFK filter in the chimney system. Installation and operation of fans with KFK damper, fans with KFK and GFK dampers with BY-PASS system in the chimney system Fan overall dimensions: Type Dimensions [mm] D B H H1 L P Mass [kg] КАМ 125 124 245 350 300 260 50 4,5 КАМ 140 139 285 350 300 300 50 5,7 149 285 350 300 300 50 5,7 КАМ 160 159 285 350 300 300 50 5,7 КАМ 125 / Duo 124 245 320 270 260 50 5,6 КАМ 140 / Duo 139 285 320 270 300 50 6,8 / Duo / max 149 285 320 270 300 50 6,8 КАМ 160 / Duo 159 285 320 270 300 50 6,8 Overall dimensions of fans with additional equipment: Fan type Additional Dimensions [mm] Mass equipment D B H H1 L P [kg] КАМ 125 FFK 124 245 530 480 260 50 6,7 КАМ 140 FFK 139 285 540 490 300 50 8,7 FFK 149 285 540 490 300 50 8,7 КАМ 160 FFK 159 285 540 490 300 50 8,7 КАМ 125 / Duo FFK 124 245 500 450 260 50 7,8 КАМ 140 / Duo FFK 139 285 510 460 300 50 9,8 / Duo / max FFK 149 285 510 460 300 50 9,8 КАМ 160 / Duo FFK 159 285 510 460 300 50 9,8 Type Additional equipment Dimensions [mm] D B H H1 L P Mass [kg] КАМ 125 KFK / KFK+GFK 124 245 610 560 260 50 8,3 КАМ 140 KFK / KFK+GFK 139 285 650 600 300 50 9,7 KFK / KFK+GFK 149 285 650 600 300 50 9,7 КАМ 160 KFK / KFK+GFK 159 285 650 600 300 50 9,7 КАМ 125 / Duo KFK / KFK+GFK 124 245 580 530 260 50 9,4 КАМ 140 / Duo KFK / KFK+GFK 139 285 620 570 300 50 10,8 / Duo / max KFK / KFK+GFK 149 285 620 570 300 50 10,8 КАМ 160 / Duo KFK / KFK+GFK 159 285 620 570 300 50 10,8 102 VENTS. Industrial and commercial ventilation 09-2011

WWW.VENTILATION-SYSTEM.COM Technical data: 125 Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230 1~ 230 Power [W] 108 110 115 116 Current [A] 0,81 0,82 0,84 0,86 Maximum air flow [m 3 /h] 400 480 520 540 RPM [min -1 ] 1300 1290 1280 1270 Noise level at 3 m [dba] 42 42 42 42 Maximum operating temperature [ о C] 150 150 150 150 Protection rating IP X2 IP X2 IP X2 IP X2 140 150 160 Technical data: КАМ 125 КАМ 140 max КАМ 160 Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 Power [W] 32 41 43 127 44 Current [A] 0,14 0,18 0,19 0,55 0,19 Maximum air flow [m 3 /h] 350 420 450 740 470 RPM [min -1 ] 1335 1250 1165 1310 1110 Noise level at 3 m [dba] 37 38 39 45 39 Maximum operating temperature [ о C] 150 150 150 150 150 Protection rating IP X2 IP X2 IP X2 IP X2 IP X2 FAN SERIES Technical data: КАМ 125 Duo КАМ 140 Duo Duo КАМ 160 Duo Speed min. max. min. max. min. max. min. max. Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230 1~ 230 Power [W] 26 32 32 41 34 43 35 44 Current [A] 0.12 0.14 0.14 0.18 0.15 0.19 0.15 0.19 Maximum air flow [m 3 /h] 265 350 340 420 360 450 375 470 RPM [min -1 ] 1210 1335 1180 1250 1075 1165 1040 1110 Noise level at 3 m [dba] 29 37 31 38 31 39 32 39 Maximum operating temperature [ о C] 150 150 150 150 Protection rating IP X2 IP X2 IP X2 IP X2 VENTS. Industrial and commercial ventilation 09-2011 103

CHIMNEY CENTRIFUGAL FANS max 104 VENTS. Industrial and commercial ventilation 09-2011

WWW.VENTILATION-SYSTEM.COM ELECTRICAL ACCESSORIES COMPATIBILITY Duo КАМ 125 КАМ 140 КАМ 160 КАМ 125 КАМ 140 max КАМ 160 КАМ 125 Duo КАМ 140 Duo Duo КАМ 160 Duo Thyristor speed controllers RS-1-300 RS-1-400 Duo RS-1 N (V) RS-1,5 N (V) RS-2 N (V) RS-2,5 N (V) RS-0,5-PS RS-1,5-PS RS-2,5-PS RS-4,0-PS RS-1,5-Т RS-3,0-Т RS-5,0-Т RS-10,0-Т RS-1,5-ТА RS-3,0-ТА RS-5,0-ТА RS-10,0-ТА Transformer speed controllers FAN SERIES RSA5Е-2-P Duo RSA5Е-2-М RSA5Е-3-М RSA5Е-4-М RSA5Е-12-М RSA5Е-1,5-Т RSA5Е-3,5-Т RSA5Е-5,0-Т RSA5Е-8,0-Т RSA5Е-10,0-Т RSA5D-1,5-Т RSA5D-3,5-Т RSA5D-5-М RSA5D-8-М RSA5D-10-М RSA5D-12-М Frequency speed controllers VFED-200-ТА VFED-400-ТА VFED-750-ТА VFED-1100-ТА VFED-1500-ТА Temperature regulators RTS-1-400 RTSD-1-400 RT-10 Multi-speed fan switches P2-5,0 P3-5,0 P5-5,0 P2-1-300 P3-1-300 EC-motors controllers R-1/010 Sensors Т-1,5 N ТН-1,5 N ТF-1,5 N ТР-1,5 N Duo recommended suitable VENTS. Industrial and commercial ventilation 09-2011 105