VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual

Similar documents
KICKSPACE 500, 600, V & 800

WHISPA III 5000, 7000 & Installation, Operating, Maintenance and After Sales Manual. Tested to UL & CSA Standards. Part Number: Issue 1

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

SLIM-LINE RC FAN CONVECTOR.

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Space Saver. New Easy Guide. Connecting your Space Saver to a central heating system BEFORE AFTER

Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator. Installation & User Guide

System Installation. multi-zone heating

Space Saver. New easy guide. Connecting your Space Saver to a central heating system. Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co.

Grohtherm Wireless! Installation Instructions Pumped

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

User's Instructions. Alpha CB50

Instructions for Use Installation and Servicing

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

INSTALLATION & USER INSTRUCTIONS

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

WHHR Midi & Midi Lite

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

Baxi Maxflow Combi WM

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

Thank you for choosing EnviroVent

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Open Vented Condensing Boilers

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

HOTLINE:

INSTALLATION & USER INSTRUCTIONS

QUALITY SPACE HEATERS

INSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Vote for your Installer of the year at HEATSLAVE

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Baxi Maxflow Combi FS

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

Installation, Operation & Maintenance Instructions

ECOLEC PANEL HEATERS GENERAL NOTES.

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

ADVANCE ECB ELECTRIC COMBINATION BOILER

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

20L/D DEHUMIDIFIER Model Number: IG9800

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

PERFORMANCE SHOWER PRODUCTS

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Thermostat install guide

Assessment Schedule - TS.6

MODEL: DC10RCDH / DC12RCDH

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

Flomate Mains Boost Pump Installation & Maintenance Instructions

Grohtherm Wireless! Installation Instructions Pumped High Pressure

UBGHFF60W 60cm Gas on Glass Gas Hob

Installation Instructions For Showermate Eco Shower Booster Pumps S1.5 bar Twin, S2.0 bar Twin, S2.0 bar Single

INSTALLATION INSTRUCTIONS

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

BOILERMATE A CLASS OV

Installation Instructions & Operating Manual IMPORTANT

Alpha CombiMax 350 and 600

Hive Active Heating. Thermostat installation guide

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Installation and Operating Instructions MODEL: MSE46W

INSTALLATION INSTRUCTIONS

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Wall hung combination boilers. This is a CAT II2H3+ appliance USER, INSTALLATION AND SERVICING INSTRUCTIONS SUPPORTED BY

Caple sense single oven instruction manual Model: C2362

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

INSTALLATION & USER INSTRUCTIONS

Quantum. Installation, User and Service Manual. Hot Spring

HEAVY DUTY BRASS SHOWER PUMPS

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Installation and Servicing Instructions

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Installation and Servicing Instructions. Alpha CD24C/32C

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

TECHNICAL INFORMATION T1500 Series Clothes Dryers

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Transcription:

VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual

INDEX 1 General information 3 2 Heating system design 3 3 Selection and Sizing for heating 3 4 Location 3 5 Preparation 4 6 Electrical Connection 5 7 Water Connection 6 8 Fitting the VD 3401 7-8 9 Technical Data 9 10 Operating Instructions 10

1. GENERAL INFORMATION This VD 3401 fan convector is designed for installation in the cavity beneath kitchen cupboards on the vacant floor space, or other similar locations. No rear access shall be available to the unit after installation. The VD 3401 should only be used on closed circulation, two pipe, pump assisted central heating systems. Before proceeding with the installation, the heating system design must be considered and the unit correctly sized to meet the heat loss requirements of the room. Flexible hoses with integral isolating valves are supplied to allow easy installation and future access for maintenance. VD 3401 are supplied with integral controls including fan speed selector and summer/winter switch. In heating mode a low limit thermostat prevents the fan from operating if the heating system water temperature is below 43 C. In summer mode the fan can be operated to circulate a flow of air without any heat supply. The unit MUST NOT be installed in a bathroom or other similar high humidity area 2. HEATING SYSTEM DESIGN This fan convector must be fitted on a two pipe, pumped circulation heating system. For optimum fan convector heating performance the system must be capable of providing sufficient hot water through the heat exchanger. This means that: 1. The minimum pipe size from boiler to fan convector must be at least 15mm. Microbore pipe MUST NOT be used. 2. Where the unit is fitted on to a system with other emitters a separate circuit for the fan convector should be considered to provide adequate water flow. 3. The system water must be above 43 C for fan to switch on, and for satisfactory operation the mean water temperature should not be below 60 C. 4. This unit is NOT suitable for one-pipe systems. 5. Optimum performance will require effective balancing of the whole system. 6.!t is not recommended that this unit is used to replace a radiator in an existing system unless an adequate flow of water can be guaranteed.

3. SELECTION AND SIZING FOR HEATING Heat output performance is given in the Technical Data section of this manual. Since VD 3401 units are supplied with fan speed control it is important to size the unit to match the calculated heat loss requirements of the room with the unit operating at the low fan speed. The higher fan speed can then be used for more rapid heating from cold in extreme conditions. 4. LOCATION This VD 3401 unit is designed for installation in the cavity beneath cupboards in kitchens or other similar locations on the vacant floor space, When installed in a kitchen consideration should be given to storage of perishable goods in the cupboard above. A minimum of 25mm clear headroom is required above the top of the VD 3401 when fitted. The unit should be mounted on a clean and level floor area under the cupboard base. 5. PREPARATION Before proceeding with the installation, unpack the carton contents and check against the checklist below; 1. VD 3401 unit 2. Flexible hoses including isolating valves (1 pair) 3. Instruction Manual 4. Warranty card 5. Grille (packed separately) 6. Screw fixing kit (with grille) A clean and level floor area is required under the cupboard base. Floor mounting - The VD 3401 is normally fitted directly onto the floor and the base of the unit is fitted with four mounting feet. Plinth mounting - As an alternative to floor mounting the unit may be fitted into the plinth. A suitable support must be securely fitted to the floor. The top of the support must be level with the lower edge of the cut-out when fitted. Decide the position of the VD 3401, mark out and cut the plinth to the dimensions of Fig. 1a (floor mounting) or 1b (plinth mounting).

6. ELECTRICAL CONNECTION Warning: this appliance must be earthed The electrical installation must comply with local or national wiring regulations. This unit is supplied fitted with a 2 meter 0.75mm 2 cord, A fused (3A) electrical spur with a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit. See Fig. 2. Room Thermostat - If a remote room thermostat is required, wire it into the fused spur at this stage. Remote Control Switch - A remote control switch is available as an accessory, and if required should be wired at this stage. Do not energize the electrical supply until the remaining stages of the installation have been completed

7. WATER CONNECTION Pipe work must be positioned correctly to ensure flexible hoses are not kinked when installed. See fig. 3. Only use the hose supplied with this unit. Do not use old or alternative hose sets. Connect valve ends of the flexible pipes to the VD 3401. Note: The direction of the flow arrows on the valves 3re not significant in this application. Open valves fully, check pipe connections for leaks and vent the heat exchanger. A vent screw is provided to vent the heat exchanger.

8. FITTING THE VD 3401 Position the VD 3401 under the cupboard in the required location, with the front edge just behind the line of the plinth. Ensure that the flexible hoses are not kinked and that the electrical cord is not in contact with hot surfaces. Replace the plinth and bring the VD 3401 forward into the opening so the front edge projects 8mm through the plinth.

Align the grille and secure it to the unit with two screws supplied (use the shorter screws). Secure the unit / grille to the plinth with two screws supplied (use the longer screws).

Complete the electrical supply, switch on and test the VD 3401. 9. TECHNICAL DATA

10. OPERATING INSTRUCTIONS This unit is controlled by the switches on the front of the unit, or by means of the wail mounted remote switching kit if fitted. Ensure the electricity supply is switched on. Heating Mode The fan will only operate when - The central heating boiler is on - The pump is running - The System water temperature is greater than 43 C. Ensure boiler is on, and set timer, boiler controls and room thermostats as necessary. Turn room thermostat to a high setting. Set summer - winter switch to. Set fan speed control position I. The unit will now run on low fan speed. For satisfactory operation the mean water temperature should not be below 60 C. Temperature control The room thermostat setting should be gradually adjusted to obtain the desired temperature. The fan speed can be set to boost by switching the fan speed switch to II. A low speed setting is recommended for normal operation with the higher speeds for boost heating when required. Low limit operation The low limit thermostat fitted to the VD 3401 will ensure that the fan stops after the heating system is switched off and the water flow stops. If left in an operating position the unit will automatically restart when the heating system is reheated. Off Position Set the fan speed selector switch to the off (0) position. Summer Mode If required, the VD 3401 can be used in summer for air circulation without heat. Set summer - winter switch to Adjust fan speed to required setting. If a remote control switch is fitted, the fan switch on the unit will be inoperative. Refer to the instructions supplied with the remote control switch for details.