Ambulatory infusion pump for continuous, intermittent, TPN or PCA delivery.

Similar documents
Clinician Information

Description of the CADD-Prizm VIP Pump

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

CADD-Prizm PCS II Ambulatory Infusion Pump Model Technical Manual

Sapphire TM. Bring Home The Future Of Infusion Care. Ambulatory Infusion System. > Intuitive, easy-to-use touch screen design

Syringe Pump. User Manual

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP

Original Perfusor & Infusomat

Mini Rythmic PN+ Set-up Guide


HOMEPUMP ECLIPSE* Ambulatory Infusion System PATIENT INFORMATION

Alaris Syringe Module v9

T34TM AMBULATORY SYRINGE PUMP

Cl inician Training Packet

M E D I C A L D E V I C E S


Infusion System. Infusion and Syringe Pumps

Alaris Syringe module FAQs

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Proven Quality Made in Germany

Alaris Syringe Module v9

Introduction. OM-THA2

Agrifim A675CT Timer. Frequently Asked Questions

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-OEM-3 OEM Packaged Voltage Data Logger

EL-OEM-3 OEM Packaged Voltage Data Logger

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EL-USB-TC Thermocouple Data Logger with USB Interface

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Directions for Use. Alaris System. Alaris Products. Supports Guardrails Suite MX (v8) August RATE (ml/h) RATE (ml/h) CHANNEL SELECT PAUSE

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

EL-USB-1-LCD Temperature Data Logger with LCD

CryoPod Carrier. Quick Start Guide. English Quick Start Guide, 2 Français Guide de démarrage rapide, 8 Deutsch Schnellstartanleitung, 14

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

(12) Patent Application Publication (10) Pub. No.: US 2014/ A1

Syringe Pump. Syringe Pump. Product Model: ZD-50C6 Syringe Pump. ZD-50C6-H Syringe Pump

Quick start guide. English

Specifications Minimum Typical Maximum Unit

User Manual. Humidity-Temperature Chart Recorder. Model RH520

TV2 Clean Room Monitor

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Refrigerator/Freezer Thermometer

Directions for Use Alaris System (with PC Unit, Model 8000)

Bryant 2007 Family of Controls

Enteral Pump Instructions for Use To Assemble When the low

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Rocket Quick Guide. Rocket PSU Portable Suction Unit

EL-USB-1-LCD Temperature Data Logger with LCD

Refrigerator/Freezer Thermometer

Administration of AMBISOME Using the GemStar Pump

Operator s Manual DigiPump LP8 Infusion Pump - Digicare Biomedical Technology Inc CONTENTS. A. About this manual...2

InTemp CX Temperature Logger (CX40x) Manual

Summit E & Summit XL Dispensers for small OPL to large laundry washer extractors and tunnels

ELMTEC. Kattreppeln Königslutter / /

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

DS User Manual


Directions for Use. Alaris System (with Alaris PC Unit, Model 8015) September 2009

LogTag TICT - is0 Tag

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

TV2 Room Pressure Monitor Quick Start Guide

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Rev This manual covers the following models: T771. Mounting and Battery Installation

OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

DAY/TIME Button: Selects hour, minute and day setting.

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

V Series Infusion Pump User Manual. Version 0.2

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Ohio Medical s Push-To-Set TM Intermittent and Continuous Vacuum Regulators

Operating your heating system with the Prefect PRE5701 Programable Thermostat

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Vernay-QM Series Disposable Pumps

Table of Contents. kangaroo 924. English. General Information... Operating Procedures... Battery... Beginning Administration...

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

16 and 16 plus User s Guide

Shenzhen Biocare Bio-Medical Equipment Co., Ltd. All rights reserved. For this User s Manual, the issue date is May Version:2.

VENTURI Compact 300 NPWT Systems Choice of Therapy Modes Advanced Predictive Low Vacuum Alarm

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Batt-Safe Battery String Monitoring System

Quick setup guide. English

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

D3000. Installation & Setup Guide

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Liberty Premium 8. User Instructions

Instruction Guide: Thermostat Operation

Customer Information Visually Impaired Programmable Talking Thermostat VIP 1007 Single Stage VIP Stage & Heat Pump VIP Stage Heat /Cool

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

user manual Document No , Revision 03 November 2015

User Manual (LS-GSM-006)

Transcription:

Ambulatory infusion pump for continuous, intermittent, TPN or PCA delivery.

The CADD-Prizm VIP (Variable Infusion Profile) pump is designed for A NEW CADD PUMP BENCHMARK FOR AMBULATORY INFUSION CARE. We ve taken the best of CADD pump technology and added new advances in safety, security and programming. DESIGNED TO LOWER TRAINING COSTS BY REDUCING TRAINING TIME. By using familiar CADD pump programming, the CADD-Prizm VIP pump helps make the transition easier for infusion nurses already trained on CADD pump technology. Prompting software designed to confirm program parameters. Over 2,000 help screens designed to always provide help at your fingertips. Familiar CADD pump disposables should mean less training. ASSET MANAGEMENT WITH THE SECURITY OF A SINGLE-THERAPY DEVICE. The VIP is a multi-use pump that acts like a single-therapy pump. A separate access code is required for delivery mode selection. Delivery modes have a history of proven performance. Delivery mode selection is separate from main programming loop. MEDICATION CASSETTE reservoir helps to provide drug security. DESIGNED FOR DURABILITY. The VIP s durable polyurethane housing and unique shape are designed to make the pump easier to handle, more resistant to impact. Stronger new housing material. Rounded corners designed to distribute impact stress evenly. WE VE ADDED TO THE EXISTING CADD PUMP SOFTWARE. We took the programming you re familiar with, enhanced it by displaying more information on each screen and added features home infusion providers have been requesting. Programming in ml/hr. PCA Doses given and attempted on the same screen. Dosing history reports. TPN Designed for easy one-step process to reset infusion profile. Programmable immediate taper down. Lower keep-vein-open rate for small-volume infusions. Indicates volume and time left in infusion. INTERMITTENT Flow rates up to 350 ml/hr. Dose volume up to 1000 ml. Delay start from 10 minutes to 4 days. Real-time clock designed to keep dosing on schedule. View time and date for next dose start time. PCA INTERMITTENT TPN BIOMED TOOLBOX COMMUNICATIONS THE VIP IS DESIGNED TO HELP BETTER MANAGE AND CON- TROL DRUG DELIVERY. New features provide more information and allow for customized settings. Cassette detection and latch/lock sensors for proper attachment and security. PCA extended history report summarizes drug delivery over the time period you select. AutoLock can be set to change the lock level to either LL1 or LL2 when the pump is started. Event log to view the last 500 events. Biomed Toolbox lets you customize the pump parameters such as custom lock level code, preventive-maintenance reminder and drug-concentration settings. Report printing capabilities.

Critical function information you need. INTERMITTENT Determine next dose start time. Programming in ml/hr with flow rates up to 350 ml/hr. PCA Dosing information available since time and date last cleared. TPN Review programmed infusion volume and determine the volume left in the infusion. DELTEC OFFERS THE BEST TRAINING AND SUPPORT IN THE INDUSTRY. 24-hour, toll-free technical and clinical phone support. Reference materials and instructional videos. In-servicing support. Deltec s commitment to innovation, quality and unconditional support has made our CADD pumps the most asked for, most often used and most dependable infusion pumps in the industry. Deltec SIMS Deltec, Inc., St. Paul, MN 55112 U.S.A. Phone: 800-426-2448 Or visit our web site at http://www.deltec.com 19800 5/97

General Pump (Nominal) RESOLUTION MEDICATION CASSETTE reservoir or CADD Administration Set, 0.050 ml per pump stroke nominal CADD-Prizm High Volume Administration Set, 0.100 ml per pump stroke nominal SIZE 4.4 cm x 10.4 cm x 14.1 cm (1.7 in. x 4.1 in. x 5.6 in.) excluding cassette or other accessories WEIGHT 568 g (20 oz.) including 9-volt battery and empty 100 ml MEDICATION CASSETTE reservoir, excluding other accessories POWER SOURCES 9-volt alkaline or lithium battery such as DURACELL Alkaline MN 1604 or ULTRALIFE Lithium U9VL; Rechargeable Power Pack reorder number 21-3801; AC Adapter. NOTE: The EPS System reorder number 21-2363 is not intended to be used with CADD-Prizm pump. PUMP ALARMS Low battery power; depleted battery power; external power source low, faulty, depleted; pump stopped; pump fault; low reservoir volume; high delivery pressure; air in line; Air Detector faulty or detached (only with the use of the optional Air Detector); Air Detector Port Cover detached; delivery too slow; key stuck; cassette detached or unlocked; print failure BOLUS VOLUME AT OCCLUSION ALARM PRESSURE 0.050 ml resolution sets/reservoirs: <0.25 ml 0.100 ml resolution sets: <2.0 ml SYSTEM DELIVERY ACCURACY ± 6% (nominal) HIGH PRESSURE ALARM 18 ± 9 psi AIR DETECTOR ALARM Single bubble greater than 0.100 ml Continuous Delivery Mode Intermittent Delivery Mode programmable in 1 ml, displayed in 0.1 ml 0-99999.9 in 0.1 ml RATE 0.1-350 ml/hr in the Biomed Toolbox PM (Preventive Maintenance) REMINDER 1-24 months in 1-month, Not In Use DATE FORMAT US Standard (mm/dd/yy) or European Standard (dd/mm/yy) EXTENDED HISTORY (PCA) On/Off following 0.1 for values between 0.1 and 100 1 for values between 100 and 350 Default: 0 ml/hr Use 9-volt battery for rates up to 250 ml/hr; use power pack or AC adapter for rates up to 350 ml/hr. CUSTOM LOCK LEVEL CODE 1-899 (excluding preset code) in of 1 POWER SOURCE DISPLAY Always display or Only Low Battery AIR DETECTOR REQUIRED Required or Not Required CUSTOM CONCENTRATIONS (PCA) Turn On All or Turn Off All or Modify Individual programmable in 1 ml, displayed in 0.1 ml DOSE VOLUME 0.1-1000 ml in the following 0.1 for values between 0.0 and 100 1 for values between 100 and 1000 Default: 0.0 ml DOSE DURATION 1 min - 24 hrs in the following 1 minute for values between 1 min and 10 min; 5 minutes for values above 10 min Default: 30 min Duration is limited by Dose Volume so that rate does not exceed 350 ml/hr. Use 9-volt battery for rates up to 250 ml/hr; use power pack or AC adapter for rates up to 350 ml/hr. DOSE CYCLE 10 min - 96 hrs in 5-minute Default: 4 hrs KVO RATE 0-10 ml/hr in 0.1 ml/hr Default: 0 ml/hr NEXT DOSE START TIME 10 min - 96 hrs x min (where x equals a 10-minute increment in the 96th hour) or Immediate; programmable in 10-minute Default: Immediate 0-99999.9 in 0.1 ml

PCA Delivery Mode TPN Delivery Mode programmable in 1 ml, displayed in 0.1 ml UNITS Milliliters (ml), milligrams (mg), micrograms (mcg) Default: milligrams CONCENTRATION Mg/ml: 0.5, 1, 2, 3, 4, 5, 10, 15, 95, 100 Mcg/ml: 1, 2, 3, 4, 5, 10, 15, 95, 100, 200, 300, 400, 500 Default: 1 DEMAND DOSE 0-9.9 ml in 0.1 ml (or the mg or mcg equivalent) Default: 0 mg Delivery rate (Continuous Rate + Demand Dose): 125 ml/hr nominal DEMAND DOSE LOCKOUT 5 minutes - 24 hours in the following 1 minute for values between 5 and 20 minutes 5 minutes between 20 minutes and 24 hours Default: 5 minutes MAX DOSES PER HOUR 1-12 doses in 1 dose (will also be limited by the Demand Dose Lockout value) Default: 1 DEMAND DOSES 0-999 DEMAND DOSE ATTEMPTS 0-999 RATE 0-30 ml/hr (or the mg or mcg equivalent) in the following 0.1 for numerical values between 0.0 and 100 1 for numerical values between 100 and 1000 10 for numerical values above 1000 Default: 0 mg/hr 0-99999.9 in 0.1 unit CLINICIAN BOLUS 0.1 ml (or mg or mcg equivalent) to 20.00 ml Delivery rate (Continuous Rate + Clinician Bolus): 125 ml/hr nominal 10.0-9990 ml or Not In Use; programmable in 1 ml, displayed in 0.1 ml Default: 10 ml INFUSION VOLUME 10-9990 ml in 10 ml Default: 10 ml INFUSION PERIOD 0 hrs 10-min - 99 hrs 50 min in 10-minute Default: 1 hrs 0 min TAPER-UP PERIOD 0 hrs 0 min - 99 hrs 40 min in 10-minute Default: 0 hrs 0 min TAPER-DOWN PERIOD 0 hrs 0 min - 99 hrs 40 min in 10-minute Default: 0 hrs 0 min PLATEAU RATE Calculated by pump; 10-350 ml/hr Use 9-volt battery for rates up to 250 ml/hr; use power pack or AC adapter for rates up to 350 ml/hr. KVO RATE Calculated by pump: 1/10 of Plateau Rate up to 5 ml/hr 0-99999 in 0.1 ml Options IMMEDIATE TAPER-DOWN (TPN) 0 - time remaining in the infusion period, in 10-minute (defaults to the currently programmed Taper-Down) AUTOLOCK Not in Use, LL1 or LL2 TIME REMAINING (Intermittent) Dose and Cycle display in 1-minute PRIME Prime tubing AIR DETECTOR Turned On or Turned Off EVENT LOG 0-500 events EXTENDED HISTORY (PCA) Up to 48 hours in 1-hour TIME AND DATE To order call 800-426-2448 CADD-Prizm VIP ambulatory infusion system Model 6100 21-8830 Pump (with continuous, intermittent, TPN and PCA delivery modes, and communications), rechargeable power pack, AC adapter, 3-liter backpack, 250-500-ml pump pouch (waist version), 50-100-ml pump pouch, pump key, operator s manual, patient information guide, 9-volt battery. CADD-Prizm VIP ambulatory infusion pump Model 6100 21-8820 Pump (with continuous, intermittent, TPN and PCA delivery modes, and communications), 50-100-ml pump pouch, pump key, operator s manual, patient information guide, 9-volt battery. Deltec SIMS Deltec, Inc., St. Paul, MN 55112 U.S.A. CADD and Deltec are registered trademarks of SIMS Deltec, Inc. CADD-Prizm and MEDICATION CASSETTE are trademarks of SIMS Deltec, Inc. DURACELL is a registered trademark of DURACELL, INC. ULTRALIFE is a registered trademark of ULTRALIFE Batteries, Inc. CADD Pumps are covered by U.S. Patent Numbers: 4,559038; 4,565,542; 4,650,469; 5,181,910; 5,338,157; 5,364,242; 5,368,562; other patents pending. 1997 SIMS Deltec, Inc. All rights reserved. Printed in the U.S.A. 5/97 19800