Instructions. Portable Absorb Phlegm. Apparatus

Similar documents
Instruction Cum User Manual For EUROLITE

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Medical Refrigerator

Tornado Operations & Maintenance Manual

Washing Machine OWNER S MANUAL. MODEL:MFW-V1100DDi

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

Dyna-Form Air. Alternating Pressure Relief Overlay System

FTA-1 Aspirator with trap flask

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

ASPIRE Laboratory Aspirator

5. Instrument and accessories discharging must be done following current law regulations in every country of use.

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

SERVICE MANUAL TWIN TUB WASHING MACHINE PWM6010M PWM8010PM PWM1010PM PWM1210PM

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Washing Machine OWNER S MANUAL MFW-801S. Before using your washing machine, please read this manual carefully and keep it for future reference.

*smith&nephew VERSAJET HYDROSURGERY SYSTEM

MODEL 7000 SUCTION UNIT

SERRES SUCTION BAG SYSTEM MANUAL

IMPORTANT SAFETY INSTRUCTIONS

Operating Instructions

Table of Contents. English

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Suction Pump F-30.xx

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

WET/DRY VACUUM Models PF51, PF53, PF55, PF57

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

G-10f/GCG-10f UPRIGHT COOLER

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

P O R T A B L E Air Conditioner

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Installation Instructions. Mira LED Light System

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

OPERATION INSTRUCTION

Tornado Operations & Maintenance Manual

HD 525 S 06/03 A ! 5.960

Sip Vacuum Cleaner 1400/35 Wet & Dry

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

CONSTANT SUCTION UNIT

Electric Hand dryer. Installation and operating manual

INSTRUCTION MANUAL Model: SU3022

Mobile Air Conditioner Instruction Manual Model TC-N9KM

HHP-300 EXTRACTOR 120V

Washing Machine OWNER S MANUAL. Before using your washing machine, please read this manual carefully and keep it for future reference.

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

PORTABLE AIR CONDITIONER (LOCAL)

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

getting the best from your new cleaner...

OPERATING INSTRUCTIONS

Washing Machine OWNER S MANUAL MODEL:TRWTL-80. Before using your washing machine, please read this manual carefully and keep it for future reference.

PORTABLE AIR CONDITIONER

Instructions for use Vacuum regulation valve with water trap

Tornado Operations & Maintenance Manual

SOLUS-500 EXTRACTOR 120V

ULTRA LOW TEMPERATURE FREEZER. User Manual

User's Manual. Exhaust Type Tumble Dryer HLP140E. Please read this manual carefully before using. Retain it for future reference.

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

BEFORE USING THE DISHWASHER/CONNECTIONS

ELITE (110V) (220V)

INSTRUCTION MANUAL MODEL: 690E

1/2011 V1. Puzer AINO USER MANUAL. Read this instruction before using the vacuum cleaner! Keep the instructions near the vacuum cleaner for later use!

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Installation & Maintenance Instructions

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

I N S T R U C T I O N S

Model: DC-159. Instruction Manual

Model: PC600. Batch: PR3496. POWER:1000W AC V, 50/60Hz For your safety, always read the instruction book carefully before using.

User manual. Dishwasher ZDTS102. Downloaded from manuals search engine

CLEANING INSTRUCTIONS

Fig. 2. Fig. 1. Fig. 3. Fig. 4. Fig. 5. Fig. 7 Fig. 6. Fig. 9. Fig. 8. Fig. 10 MAX H2O

Tornado Operations & Maintenance Manual

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

Linkam Scientific Instruments USER GUIDE TS1500 TS1200 TS1000. High Temperature Stage

Lo-Carbon T-series Window & Roof Models

OPERATING INSTRUCTIONS

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Medical Refrigerator DW-25H SERIES

Operation Instructions

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

hotchoc Operating Instructions Manual de instrucciones

User s Information Manual

π H-7241 AIR CUSHION MACHINE PARTS uline.com BOX CONTENTS

OPERATING & MAINTENANCE MANUAL

Requests for Daily Care and Maintenance

WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

LIMITED LIFETIME WARRANTY

coral 65 coral 65 II coral 85

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS

BQ-260/260L. Important Information BOOK BINDER

INSTRUCTION MANUAL Wall mounted Cooker hood Nebel INOX 90

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

HERCULES (110V) (220V) USER S MANUAL

Transcription:

Instructions On Portable Absorb Phlegm Apparatus Please carefully read the instructions before attempting to operate this apparatus.

Product Features 1. General Portable absorb phlegm apparatus designed based on developing orientation of similar products at home and abroad is a new generation of oil free lubrication suction device, which is suitable for use by the patient who has difficulty in phlegm removal due to illness, coma and operation, as well as for aspirating such liquid as pus and blood during the clinical practice. It is the commonly applied medical device for use in the emergency room, operation room, and for nursing in sickroom and home health care. 2. Structure & Working Principle Oil free lubrication pump applied to keep the environment from being polluted by the oil mist; Lower noise; New style of the embedded liquid holder, square negative pressure meter, and full plastic enclosure; No any positive pressure to be generated during running, to ensure reliable and safe operation; Negative pressure regulating system in stepless adjustment as required; Suitable for first-aid and outdoor go-round for medical treatment because of its features such as small volume, light weight, and easy to carry about; Systematic diagram shown as follows: 1

Systematic Diagram 1.Exhaust outlet 2.Suction inlet 3.Silencer 4.Vacuum pump 5.Negative pressure regulating knob 6.Overflow valve 7.To phlegm suction catheter 8.Vacuum meter 9.Air filter 10.Liquid holder 3. Main Technical Performances (1) Limit negative pressure: 0.075 MPa (2)Negative pressure regulating range: 0.02 MPa ~ limit negative pressure (3) Suction rate: 18 L/min(for adult suction) 15L/min(for child suction) (4) Noise: 65dB (A) (5) Liquid holder: 1000 ml/pc, 1 pc (6) Power source: AC 220 V /50Hz,1.5A AC 110 V /60Hz,2A (7) Input power: 90 VA (8) Weight: 4.4kg (9) Overall size: 280 196 285 (mm) The apparatus is not suitable for use in the place with inflammable & explosive gas; Working system: short time running; Electric safety requirement: Class I, Type B equipment. 4. Normal Operating Conditions Ambient temperature: 5 ~ 40 Relative humidity: 80% Atmospheric pressure: 86 kpa~ 106 kpa 2

Installing and Commissioning 1. Open Package Inspection The customer shall carefully inspect if the appearance of product is good, and the varieties & quantities of the attachments are in conformity with those as indicated in the attached list before installing and commissioning. Also, the customer shall timely notify the supplier or manufacturer of damage(s) if any. 2. Connecting (See Tube Connecting Diagram, with phlegm suction catheter temporarily not connected) Note: Apply small amount of distilled water around the part (pressed into the holder mouth) of holder plug during installing, which is good for tightly pressing the holder plug and enhancing its sealing. Tube Connecting Diagram 1.Suction tube 2.Air filter 3.Blue mark 4.Suction conductor 5.Liquid holder 6.To the phlegm suction catheter 3. Power line connection Connect the plug with the power source. Turn on the power supply, and the power indicator will illuminate. 3

Note: The power plug is used for power shut-off, and the power socket shall be grounded reliably. 4. Connector inspection Turn tightly the negative pressure regulating valve clockwise, and block the air suction inlet with the finger or the rubber head of dropper, or fold up and hold the suction tube; Start the aspirator for running with no strange sound; the pointer on the vacuum meter will quickly reach up to the limit negative pressure. Release the suction inlet, the pointer will return below 0.02 Mpa. If so, the connector can be regarded as being in good connection. Attach the phlegm suction catheter. The negative pressure in the negative pressure system shall be less than 0.06 MPa at the time of attaching F6 suction catheter, less than 0.04 MPa when attaching F8 suction catheter and less than 0.03 MPa when attaching F12 suction catheter. If so, the phlegm aspirator is considered as being in normal condition. Note: Dredge the suction catheter if blocked as per the following method: Bend the suction conductor in V form (with no liquid in the holder), and release it to the original status when the negative pressure reaches up to the maximum value. Repeat this procedure several times till the catheter is not blocked. 5. Negative pressure regulating Block the suction inlet, open the aspirator switch and regulate the negative pressure valve, and the readings on the pressure meter shall be within 0.02 MPa ~ limit negative pressure. Control the negative pressure as required for suction by means of the negative pressure valve at the time of clinical practice; 4

Increase the negative pressure by turning the valve clockwise; Reduce the negative pressure below 0.02 MPa prior to power shut-off. 6. Inspection & test on the overflow device Open the holder plug; clean up the valve mouth, and leveling the rubber valve clack on the float. The valve clack shall not be warped, bent and broken, but well connected with the float. The float shall be able to move freely in its support without any blockage; Lift the holder plug with hand to make the float contact the water surface perpendicularly. Gradually lower the holder cover to let the float rise; Tighten the hold plug, attach the suction tube conductor at the inlet, and screw firmly the regulating valve, then, actuate the aspirator; Put the suction conductor into one clean water pail or attempt to simulate actual application to suction the liquid into the holder of the overflow device. As a result, the float will rise as the liquid level ascends until the valve is closed and suction stops automatically. The final position of liquid level depends on the suction process adopted; Release the regulating valve, set the aspirator switch off, open the holder plug and empty the liquid in the holder. The float shall be at the bottom of the support and the valve is in open status in case of re-screwing firmly the hold plug; If so, the overflow device is considered as being in normal condition, which can be used for clinical practice. Note: 1. The liquid level still continuously ascends after the overflow device has been shut off, possibly due to: (1) Residual negative pressure still in the holder; (2) Valve mouth not fully closed. 5

For Item (1), the liquid level in the holder will not ascend when the suction tube conductor is placed again into the liquid as suctioned, and for Item (2), the liquid level still ascends. Thus, it is required to observe carefully, and lift immediately the conductor out of the suctioned liquid when the holder is close to full, then, switch off the aspirator to stop suction, and examine the possible reason of the valve fault. 2. The float is still adhered on the valve mouth as already closed by the float, possibly due to the negative pressure in the line. At this moment, release the regulating valve or shut off the aspirator (to release the negative pressure in the line), the float will descends from the valve mouth under the action of gravity. (It is forbidden to pull the float with hand, in order to avoid the rubber valve clack being separated from the float); 3. After shut-off, release the negative pressure, then, open the holder plug; 4. Never use the aspirator under the condition of the overflow device & the conductor dismantled. 7. Stop running Turn off the aspirator switch, and pull the power plug out of the socket to shut off the power supply. 8. Legends & implication for the sake of safety Symbol Meaning Symbol Meaning ~ AC power Note! Refer to the document on board 6

Application and Maintenance 1. Application & maintenance Check the aspirator before using as per the installing and commissioning sequence to ensure its good performances, afterwards, start operation by connecting the suction conductor and the phlegm suction catheter already sterilized; Note: Please refer to the instructions before attempting to use the suction catheter supplied with the aspirator. Regulate the negative pressure as required for suction through the regulating valve, open/close the switch based on the situation, and observe frequently the liquid level in the holder in the process of operation. Stop suction if the liquid level in the holder ascends to the rated capacity (still applicable if slanting the aspirator 10º), and re-use it after empty and clean-up. Otherwise, the float will rise as the liquid level ascends till the valve is closed and suction stops automatically; Note: Adopt the procedures mentioned in Inspection & test on the overflow device, if the liquid level still ascends after the overflow device has been shut off. Emergency measures in the process of application: --- Quickly loosen the negative pressure regulating knob to release the negative pressure if the suction catheter is blocked by strong phlegm and mucus, and start suction again after changing the suction tube; --- Adopt the above method to loosen the negative pressure regulating knob if it is not easy to take out the suction catheter after completion of suction or the tube is adhered to human body tissue. Note 1: Bend the tube in V form prior to starting suction, insert the suction catheter into the location of existing phlegm on the patient when the negative pressure reaches the desired 7

range after start-up, then, recover the tube to its original status. This will lead to quicker suction effect. Note 2: The medical personnel shall select the proper suction catheter according to the clinical requirement. Note 3: The aspirator shall be operated under the medical personnel s instructions strictly according to the scope of application and the operating sequence listed in the instruction manual. Please contact the supplier or manufacturer if there is any question. 2. Changing air filter It is required to change air filter with the one produced by us in case of foam or dusts fully accumulated in the air filter, which leads to gradually darkening of the color of filter diaphragm and obviously reducing or even disappearing of suction force at the inlet of tube while the negative pressure indicated on the vacuum meter climbs up to 0.04 MPa or more. Note 1: The suction force will diminish or disappear, and the negative pressure ascend if the overflow device is closed, and the tube blocked in the process of application. Please refer to Trouble Shooting. Note 2: Necessary to frequently change air filter and destroy it centrally. 3. Changing the fuse tube The fuse tube is mounted at the rear of the base. Switch off the power supply, and turn it counterclockwise and open, then, start changing the tube. 4. Maintenance It is recommended to have the suction tube suctioned small amount of clean water for cleaning up the inner wall; 8

After use, empty the holder, clean up dirt on the holder and plug with soft brush or rag, flush it with water and conduct sterilization. (including the overflow device, the seal ring and various tubes. Unscrew the overflow device, and separate the float from its support for completely cleaning up, if necessary. (Note: The rubber valve clack shall not be separated from the float.) Use the physiological saline to clean out the residual strong phlegm and mucus in the tube after used. Replace the suction catheter if not smooth. It is recommended to adopt one-time suction catheter; Place the holder, cover and all tubes into the disinfectant compounded with the Kangweida disinfector tablets (0.5 g per tablet) in 1:500 concentration for 1 hour Note: Keep the glass holder away from any sharp utensils to avoid drop in the process of cleaning and application. Wipe the case outer surface with lightly wet rag already soaked in the disinfectant, and prevent any liquid seeping into the pump. Never wipe the places marked with letters and patterns; Place the machine in dry and clean places, and periodically start running once a time (normally one time every 6 months). Note: Install the overflow device, conductor and other tubes as per the connecting mode before re-use. 5. Trouble shooting No Problem Reason Possible Solution Remarks 1 Limit a. Holder mouth leakage; a. Remove dirt, tighten or change negative the holder cover, seal ring, and pressure < b. Leakage on connecting connector; b. Change 0.075 MPa points; b. Re-tighten each connection point; the broken c. Regulating valve loose suction or released. c. Turn tightly the regulating valve catheter 9

No Problem Reason Possible Solution Remarks 2 Negative a. Overflow device a. After shut-off, turn the regulating a. Empty pressure > shut-off; valve loose counterclockwise to the holder 0.04 MPa, release negative pressure in tube, timely; with distinct b. Tube blockage; then re-screw; c. The end reduction or c. Air filter blockage b. Dredge, clean or replace the tube; ( in blue disappearing c. Replace it with air filter produced mark) of air of suction by us. filter is the force at tube air inlet outlet 3 Normal power a. Loose socket; a. Repair or change the socket; voltage, but b. Fuse broken; b. Replace the fuse tube; b.refer to the indicator c. Indicator damaged c. Replace the indicator attachments. doesn t illuminate 4 Fuse tube a. Voltage over high; a. Adjust voltage; By the broken b. Internal line in b. Check the circuit line, and specialized fault; correct; maintenance C. Pump blocked, c. Check the pump body and motor worker and current ( Refer to increasing Electric Systematic Diagram) Note: The dismantling & repair on the pump body if fault shall be conducted by the specialized worker. Please contact the manufacturer if required. 10

Precautions 1. Handling and storage environment conditions Ambient temperature: -40 ~ 55 Relative humidity: 95% Atmospheric pressure: 50kPa ~ 106 kpa Note: It is required to store the aspirator in the well-ventilated room without corrosive gas, and avoid any violent shock while handling. 2. Electric systematic diagram Electric Systematic Diagram Electric repair to be conducted by the specialized operator. 3.Attachments Suction conductor (2m long): one pc Air filter: two pcs Fuse tube two sets RF1 Ф5 20/1.5A RF1 Ф5 20/2A Suction catheter one pc respectively of child & adult (for adult suction) one pc of child (for child suction) Instruction manual one copy 11