INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Similar documents
IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Approvals, Certificates and Conditions

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Manual Power relay SR853

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

HazLoc Essential Guides:

IECEx Certificate of Conformity

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

4) Intrinsic Safety Certification

IECEx Certificate of Conform ity

OPTIBAR DP 7060 Supplementary Instructions

ATEX/05/1/7. In detail:

Intrinsically Safe or Explosionproof? Understanding the technology

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

Operating Instructions

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Certification Supplement Manual

Annubar Flowmeter Series

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

IECEx Certificate of Conformity

PRODUCT CONFORMITY CERTIFICATE

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Flameproof Manual Call Points

INSTRUCTION & SERVICE MANUAL

TRASCO ATEX Couplings

805QS Pressure Switch-Transmitter

ATEX Safety Instructions. DYNHRT3MMSS Line Rider

RM100S RM100S. Intrinsically-Safe Fieldbus Device Coupler. ROUTE-MASTER Fieldbus System. November A1

Certification Supplement Manual

Model 144H. Product Data Sheet , Rev DB February Content

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Model 144H. Product Data Sheet , Rev DB February Content

Certification Supplement Manual

HYTEK ATEX APPROVED BUND ALARM

IECEx Certificate of Conformity

IRceL CH4 Methane (CH 4

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Intrinsically Safe Transmitters, Option Code 2n

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Rosemount 3490 Series

User s Manual YTA610 and YTA710 NEPSI Certification

PRODUCT CONFORMITY CERTIFICATE

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

IECEx Certificate of Conformity

Certificate of Compliance

IR15 Dual Gas Series Datasheet

ANNEX GD-CERT-EX-EN SIT

VERSAFLOW VORTEX Supplementary instructions

METALDRIVE ATEX Couplings

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

INSTRUCTION MANUAL (ATEX)

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Quick Start Guide For the

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

NoZone Ozone Scrubber

Certificate of Compliance

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

IECEx Certificate of Conformity

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Reporting Changes to your Notified Body

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 752 Fieldbus Remote Indicator

IR25 Dual Gas Series Datasheet

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Manual for QX0201 Push Button

slra IEC of Gonformity IECEx Cert f cate ü* t4

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Transcription:

INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com

CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions for Safe Use 4 Operational Cautions 5 Certification EC Declaration of Conformity ATEX Certificate IECEx Certificate 6 7 8 11 The LM000 is an explosion-proof laser measurement device suitable for use in hazardous areas (Ex zones: potentially explosive environments). Read and understand all Warnings and Cautions before using this product. Liability The technical specification of the camera complies with relevant European Ex standards (EN 60079-0 and EN60079-1). The user is solely responsible for ensuring the equipment is suitable for the intended purpose and environments. CorDEX Instruments will not be liable for any injury or damage resulting from unauthorized adjustments to, or dismantling of, the camera or for use with inappropriate applications or environments. Trademark Information Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Pentium is a registered trademark of Intel Corporation. Macintosh is a trademark of Apple Computer, Inc. SD is a trademark. Other names and products may be trademarks or registered trademarks of their respective owners. Product Information Product design and specifications are subject to change without notice. This includes primary specifications, software, software drivers, and user s manual. The User Manual is a general reference guide for the product. The manufacturer assumes no liability for any errors or discrepancies in the user manual.

SPECIAL CONDITIONS FOR SAFE USE OPERATIONAL CAUTIONS (as defined by clause 29.2 (i) of EN 60079-0) The conditions referenced in this section relate specifically to hazardous area applications and must be followed. In accordance with clause 5.1 of EN 60079-1, the critical dimensions of the flamepaths are: Flamepath Main body/ cover Main body/ battery pack Front Lens/ main body Top lens/ main body Maximum Gap (mm) 0.04 11.0 0.04 10.0 0.1 1.8 0.1 1.8 Minimum L (mm) This equipment must only be used where there is a low risk of mechanical impact. The equipment is manufactured in aluminium alloy, in Group I applications this equipment must not be utilised where there is a risk of thermite reaction frictional ignition. The LaserMETER 000XP must only be recharged in a non-hazardous area. Extreme Care should be taken to ensure that no damage occurs to the flamepath between battery and casing. Ensure dowel location pins are engaged fully before tightening locking screws. LaserMETER 000XP incorporates a protected battery system with a replaceable fuse. This Fuse is only to be replaced with CorDEX Instruments Type CDX241-120 fuse. Failure to do so will void the certification. Ensure that the LaserMETER 000XP battery pack is secured using the screws provided. If the screws are lost, only replace with screws of the correct size and type. If in doubt, contact your nearest CorDEX Instruments representative. The LaserMETER 000XP is manufactured from aluminium alloy with less than 7% magnesium by weight and incorporates toughened glass windows. This should be taken into account when considering the end use application. The LaserMETER 000XP cannot be maintained in the field and must be returned to the manufacturer should repair or maintenance be required. The cautions contained in this section do not relate specifically to safe use in hazardous area applications but should be followed to help prevent damage to the camera or personnel. Do not fire the Laser close to anyone s eyes. This might cause damage to the person s eyesight. Keep out of the reach of children. A Laser is a precision instrument. Do not drop it, strike it or use excessive force when handling the Laser. This might cause damage to the device. Do not wrap the Laser or place in cloth blankets. Focus Ring 15 Swivel Lens 5

CERTIFICATION EC DECLARATION OF CONFORMITY Model LaserMETER 000XP Certificate No. Sira 08ATEX129X IECEX SIR 10.01X Certificate Type 0518 CorDEX Instruments Ltd Unit 1, Owens Road Skippers Lane Industrial Estate, MIDDLESBROUGH, TS6 6HE Declaration No. SO/ 4 Ambient Temperature I/II M2/2 G Ex d I / Ex d IIC T4 Tamb -20 C to +50 C EC-Type Examination Certificate: Sira10ATEX128X EC Declaration of Conformity in accordance with EEC ATEX Directive 94/9/EC Power Supply Battery Pack CDX241-007 We, CorDEX Instruments Ltd. Hereby declare that the products described below Product: Model: Laser Distance Meter LM 000XP are in conformity with the essential health and safety requirements of Council Directive 94/9/EC relating to equipment intended for use in potentially explosive atmospheres (ATEX Directive) I/II M2/2 G Ex d I/IIC T4 (Ta = -20ºC to + 50ºC) equipment, by the application of the following Standards:- EN 60079-0:2006 EN 60079-1:2007 Electrical apparatus for explosive gas atmospheres. General requirements Explosive atmospheres. Equipment protection by flameproof enclosures "d" and are subject to the procedure set out in Annex VII of Directive 94/9/EC and these procedures are in conformity with the requirements of EN 1980:2002 under the supervision of Notified Body Number 0518, SIRA Certification Service, Rake Lane, Eccleston, Chester, CH4 9JN, England. It is ensured through internal measures that the products conform at all times to the requirements of the current EEC Directives and relevant standards. Signature: Authorised Person Position: Director on behalf of CorDEX Instruments Ltd Date: 07/10/2014 Product Serial number Better:Better_Work:CorDEX:0_CorDEX_Products:CorDEX_Products_LM000:CorDEX_ECDeclaration:EC Declaration of Conformity (LM000XP) Rev D.docx 7

ATEX CERTIFICATE 9

IECEx CERTIFICATE OF CONFORMITY 11

1

Copyright 2014, CorDEX Instruments Limited. All other brand and product names are trademarks of CorDEX Instruments Limited. Document Number: ID 2105 Revision: A