... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Similar documents
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Assembly. Host Sub-D Alarm

Temperature Measurement Transmitters for field mounting

Inductive slot sensor

Technical Data. Dimensions

Operating Instructions Edition 02/2007

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Model 144H. Product Data Sheet , Rev DB February Content

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Model 144H. Product Data Sheet , Rev DB February Content

PEPPERL+FUCHS GmbH

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Engineering Guideline. pac- Carriers Type Universal

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

FAHM Co. Temperature Transmitter PTT74 Series

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

Analog Input Module IC670ALG630

USB Interface for setup program. 1 analog output standard signal. LCD display with white background lighting. 1 relay output pre-alarm ( KV)

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Instrumentation Products and Applications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Gas cylinder scale Model GCS-1

Rosemount 644 Temperature Transmitter

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

Rosemount 3490 Series

4) Intrinsic Safety Certification

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Rosemount 3144P Temperature Transmitter

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

OPTIBAR P 1010/2010 C Supplementary instructions

Module Features are-configurable, no module jumpers to set

AO Annunciator Module

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

02/11/2015

Rosemount 3144P Temperature Transmitter

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

UL HAZARDOUS LOCATIONS SERVICES

Rosemount 3144P Rosemount 3144P Temperature Transmitter

I/A Series 716C 1/16 DIN Temperature Controller

The next generation thermometer from the global leader

OPTIBAR DP 7060 Supplementary Instructions

Manual Power relay SR853

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Certificate of Compliance

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

EU DECLARATION OF CONFORMITY

SITRANS T. Temperature transmitter SITRANS TH100. Introduction 1. General safety information 2. Description 3. Assembly 4. Connecting 5.

Universal controller for panel mounting Models CS6S, CS6H, CS6L

02/11/2015

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Temperature Solutions Line Card

Rosemount 248 Temperature Transmitter

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

SITRANS T temperature transmitters A broad product family for every application. sitrans

Analog Annunciator Unit SACO 16 A3. Product Guide

FDOOT241-A9-Ex Multisensor fire detector

Temperature Controllers

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Series Temperature Controller Instruction Sheet

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

the next generation thermometer from the global leader

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Rosemount 848T High Density Temperature Measurement Family

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

UDC 700 Universal Digital Controllers and Indicator Specifications

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Danfoss gas detection unit Type GD Heavy Duty

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

INSTRUCTION & SERVICE MANUAL

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Rosemount 248 Temperature Transmitter

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

Transcription:

emperature Multi-Input Device for Cabinet Installation Features Assembly For 8 temperature or analog sensors Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc. to FISCO or Entity For FOUNDAION Fieldbus H1 PCS integration via device description and function blocks Concentrator method for simplified configuration Monitors sensor condition For /C, 2-, 3-, 4-wire, voltage and resistance Cold junction compensation Removable terminals Function he emperature Multi-Input (M-I) for DIN rail installation connects up to 8 analog inputs to the DCS via fieldbus. It is installed in a typically pre-wired field enclosure close to the sensors in the hazardous area. he M-I is certified intrinsically safe and as associated apparatus: inputs are intrinsically safe even when the fieldbus connection is not. Analog inputs can be resistance temperature sensors with 2, 3, and 4 wires, measuring sensors, thermocouples, or millivolt signals. he M-I communicates all data, configuration, and alarms via one fieldbus address and function blocks (8xAI or 1xMAI) to the DCS. For simplified configuration it supports the concentrator method: inputs can be configured all at once or individually. Fieldbus powers the sensors and the temperature interface itself, additional power or wiring is not required. Cold junction compensation for thermocouples is integrated. he M-I detects and reports lead breakage and short circuit conditions. Connection FB/SP PI S - + MAU µc MUX Channel 1 Channel 8 H H... L L mv Zone 1 1

General specifications Design / Mounting Cabinet installation Fieldbus interface Fieldbus type FOUNDAION Fieldbus Physical layer profile profile type 511 (FISCO), profile type 111 (Entity) IK version 6.2.0 (DEV_REV 02) Implementation resource block1x RS function block8x AI, 1x MAI transducer block8x sensor B, 1x concentrator B Execution time AI, MAI 40 ms max. Macro cycle typical for one device 8xAI or 1xMAI 500 ms Firmware update via separate plug connection FDE (Fault Disconnect Equipment) 6.7 ma Polarity not polarity sensitive Rated voltage U N 9... 32 V Rated current I N 23 ma Indicators/operating means LED PWR green: on, bus voltage existent LED COM ERR red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error LED CHANNEL ERROR red: 2 Hz flashing: lead breakage, overrange; off: no error ransfer characteristics Deviation Cold junction compensation ± 0.5 C (32.9 F) Resolution/accuracy see table 2 Influence of ambient temperature see table 3 Linearization /C input 0.1 C input 0.03 C Internal measurement cycle for all sensor types 1 s Galvanic isolation Fieldbus/inputs safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Standard conformity Galvanic isolation EN 60079-11 Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Ambient conditions Ambient temperature -40... 70 C (-40... 158 F) hazardous area -40... 85 C (-40... 185 F) safe area Storage temperature -40... 85 C (-40... 185 F) Relative humidity 95 % non-condensing Shock resistance 15 g, 11 ms Vibration resistance 5 g, 10... 150 Hz Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type plug-in terminals, spring terminal and screw terminal Core cross-section up to 2.5 mm 2 Inputs up to 2.5 mm 2 Housing material Polycarbonate Degree of protection IP20 Mass 360 g Mounting mounting on DIN rail in cabinet Data for application in connection with hazardous areas EU- Examination Certificate PB 03 AEX 2237 Marking II 2 (1) G Ex ia [ia Ga] IIC 4 Gb, II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC, II 3 G Ex ic IIC 4 Gc FISCO see EC- Examination Certificate Inputs see EC- Examination Certificate Certificate PB 03 AEX 2238 X Marking II 3 G Ex na IIC 4 Gc 2

Galvanic isolation see Statement of Conformity Input see EC- Examination Certificate Directive conformity Directive 2014/34/EU EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010 International approvals IECEx approval IECEx PB 05.0001, IECEx PB 05.0002X Approved for Ex ia [ia Ga] IIC 4 Gb, [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ic IIC 4 Gc, Ex na IIC 4 Gc Certificates and approvals Marine approval DNV A-14038 General information Supplementary information code/order designation EC- Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com. Code RD0-I-Ex8.FF.S RD0-I-Ex8.FF.SC Description Fieldbus temperature interface with 8 inputs with screw terminals without field housing for mounting on DIN rail in cabinet Fieldbus temperature interface with 8 inputs with spring terminals without field housing for mounting on DIN rail in cabinet Dimensions Service Interface LED channel error LED comm. LED power Configuration 217 Separation, used when device is installed in zone 2 and inputs in zone 1 or zone 0 DIN mounting rail 60 100 CH2 CH4 CH6 CH8 CH1 CH3 CH5 CH7 CH1... CH8 + - S Mounting on DIN rail Figure 1: RD0-I-Ex8.FF.SC Installation note see manual 3

Additional information able 1: Sensor types hermocouple Standard Range ( C) Range ( F) B EN 60584-1 300... 1800 572... 3272 E EN 60584-1 -200... 1000-328... 1832 J EN 60584-1 -200... 1000-328... 1832 K EN 60584-1 -200... 1372-328... 2502 N EN 60584-1 -200... 1300-328... 2372 R EN 60584-1 0... 1768-32... 3214 S EN 60584-1 0... 1768-32... 3214 EN 60584-1 -200... 400-328... 752 ASM 988-96 0... 2000-32... 3632 Range (mv) Range 1-100... 150 Standard Range ( C) Range ( F) Pt50 EN 60751 (IS90) -200... 850-328... 1562 Pt100 EN 60751 (IS90) -200... 850-328... 1562 Pt100 JIS C 1604-1989 -200... 630-328... 1166 Pt200 EN 60751 (IS90) -200... 850-328... 1562 Pt500 EN 60751 (IS90) -200... 850-328... 1562 Pt1000 EN 60751 (IS90) -200... 850-328... 1562 Ni100 DIN 43760-1987 -60... 250-76... 482 Ni120 Minco standard -80... 320-112... 608 Ni200 DIN 43760-1987 -60... 250-76... 482 Cu10 SAMA RC21-4-1966-70... 150-94... 302 Range (Ohm) Range 1 0... 650 Range 2 0... 1300 Range 3 0... 2600 Range 4 0... 5200 able 2: Accuracy hermocouple Range ( C) Range ( F) B 300... 600 600... 1200 1200... 1800 E -200... -50-50... 1000 J -200... 0 0... 1000 K -200... 0 0... 1372 N -200... -100-100... 500 500... 1300 R 0... 350 350... 1768 S 0... 550 550... 1768-200... -50-50... 400 0... 800 800... 2000 572... 1112 1112... 2192 2192... 3272-58... 1832 32... 1832 32... 2502-328... -148-148... 932 932... 2372 32... 662 662... 3214 32... 1022 1022... 3214-58... 752-32... 1472 1472... 3632 Accuracy ( C) ( F) ± 3.32 ± 1.77 ± 1.08 ± 0.42 ± 0.31 ± 0.48 ± 0.31 ± 0.68 ± 0.43 ± 1.03 ± 0.54 ± 0.39 ± 1.93 ± 1.16 ± 1.92 ± 1.15 ± 0.66 ± 0.35 ± 0.80 ± 1.05 Accuracy (µv) Range 1 ± 20 Accuracy ( C) ( F) Pt50 ± 0.77 ± 1.39 Pt100 ± 0.33 ± 0.59 Pt100 JIS ± 0.33 ± 0.59 Pt200 ± 0.33 ± 0.59 Pt500 ± 0.31 ± 0.56 Pt1000 ± 0.31 ± 0.56 Ni100 ± 0.18 ± 0.32 Ni120 ± 0.18 ± 0.32 Ni200 ± 0.18 ± 0.32 Cu10 ± 2.99 ± 5.38 ± 5.98 ± 3.19 ± 1.94 ± 0.76 ± 0.56 ± 0.86 ± 0.56 ± 1.22 ± 0.77 ± 1.85 ± 0.97 ± 0.70 ± 3.47 ± 2.09 ± 3.46 ± 2.07 ± 1.19 ± 0.63 ± 1.45 ± 1.89 Accuracy (mohm) Range 1 ± 115 Range 2 ± 230 Range 3 ± 460 Range 4 ± 920 4

able 3: Influence of ambient temperature hermocouple Range ( C) Range ( F) Deviation ( C/K) B 300... 600 600... 1200 1200... 1800 E -200... -50-50... 200 200... 1000 J -200... 0 0... 200 200... 1000 K -200... 0 0... 500 500... 1372 N -200... -100-100... 500 500... 1300 R 0... 350 350... 800 800... 1768 S 0... 550 550... 800 800... 1768-200... -50-50... 200 200... 400 0... 800 800... 2000 572... 1112 1112... 2192 2192... 3272-58... 392 392... 1832 32... 392 392... 1832 32... 932 932... 2502-328... -148-148... 932 932... 2372 32... 662 662... 1472 1472... 3214 32... 1022 1022... 1472 1472... 3214-58... 392 392... 752-32... 1472 1472... 3632 Deviation (µv/k) Range 1 ± 2 Deviation ( C/K) Pt50 ± 0.010 Pt100 ± 0.010 Pt100 JIS ± 0.010 Pt200 ± 0.010 Pt500 ± 0.010 Pt1000 ± 0.010 Ni100 ± 0.010 Ni120 ± 0.010 Ni200 ± 0.010 Cu10 ± 0.010 Deviation (mohm/k) Range 1 ± 6 Range 2 ± 6 Range 3 ± 13 Range 4 ± 26 ± 0.0060 ± 0.0131 ± 0.0242 ± 0.0070 ± 0.0036 ± 0.0203 ± 0.0072 ± 0.0039 ± 0.0243 ± 0.0077 ± 0.0097 ± 0.0323 ± 0.0080 ± 0.0088 ± 0.0264 ± 0.0057 ± 0.0129 ± 0.0338 ± 0.0094 ± 0.0135 ± 0.0355 ± 0.0071 ± 0.0035 ± 0.0067 ± 0.0151 ± 0.0552 5