User s Information Manual

Similar documents
User s Information Manual

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

User s Information Manual

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Cast Iron Commercial Hot Water Or Steam Boiler

USER'S INFORMATION MANUAL

TO DO IF YOU SMELL GAS

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

User manual. Logano GC 124 II. Gas boiler

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

G61MPV SERIES GAS FURNACE WARNING

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

WHAT TO DO IF YOU SMELL GAS

USER S INFORMATION MANUAL

User s Information Manual Models: 45, ,000 Btu/hr

95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER

USER S INFORMATION MANUAL

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

USER S INFORMATION MANUAL

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

EL195DFE SERIES GAS FURNACE WARNING

Columbia Boiler Company

/2010 US/CA

Operating instructions

EL195UH SERIES GAS FURNACE WARNING

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL

HWX GAS BOILERS USER S INFORMATION MANUAL

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

Operating instructions

USER'S INFORMATION MANUAL

USER'S MANUAL PGE Single Package Rooftop

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

USER S INFORMATION MANUAL (2,4)SG13B

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Universal Fire Tube Boiler Wall Mount Models

USER S INFORMATION MANUAL

User s Information Manual Models:

DT/DTH/DR/DRH MERIT SERIES

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

New Power Vented Rheem FVIR Tanks

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

WARNING FIRE OR EXPLOSION HAZARD.

USER S INFORMATION MANUAL SLP98UHV SERIES

WARNING FIRE OR EXPLOSION HAZARD.

Operating instructions

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

DT-2 & DR-2 MERIT SERIES

Packaged Gas/Electric

User s Information Manual Models:

GAS BOILERS USER'S INFORMATION MANUAL SG-135-E TO SG-495-E AAA-480 TO AAA-3000

User s Information Manual

USER S INFORMATION MANUAL

User s Information Manual

MC Series Gas-Fired Heating Appliance

QHT Manual for: SU-2A Gas Burner

G95V NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE USER S INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

User s Information Manual

User's Infomation Manual

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

User s Information Manual

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

User s Information Manual

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Elite. User s Information Manual. Elite and Elite VWH* All Models

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

Residential Gas Hybrid Water Heater

User s Information Manual

GOLD. User s Information Manual. Water Boiler Series 4

Owner s Information Manual

WHAT TO DO IF YOU SMELL GAS

SLANT/FIN AUTOMATIC VENT DAMPER For Galaxy, Sentinel and Sentry Series Boilers INSTALLATION INSTRUCTION MANUAL AND TROUBLESHOOTING GUIDE

Fig. 1 - Unit PGD4, PGS4, WPG4

Transcription:

Residential Gas fired Hot Water Boilers User s Information Manual VICTRY VSPH SERIES GAS BILERS Sealed Combustion - Direct Vent Models FR YUR SAFETY: Before operating this boiler, READ this manual. D NT attempt to install, service or repair this boiler yourself. There are no user serviceable parts. Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas supplier for a list of qualified service agencies. A qualified service agency should inspect the venting system of this boiler on an annual basis. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. D NT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT T D IF YU SMELL GAS D NT try to light any appliance. D NT touch any electrical switch D NT use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Your gas boiler must be installed and serviced by a qualified service agency or gas supplier. The lack of proper service can result in a dangerous condition. This manual must be left with owner, hung on or adjacent to the boiler. wner should retain manual for future reference. Printed in U.S.A. 915 Part No. 455036 Publication No. VSPH-UIM Rev. A

VICTRY VSPH Models 2 Air flow proving switch Integrated boiler control Blower assembly Water Temperature Control Circulator 120/24V transformer Gas valve Junction Box Figure 1. Location and Identification of parts. WELCME T UR VALUED CUSTMER You are now the owner of a Slant/Fin Victory VSPH gas-fired boiler, another quality heating product designed and manufactured by an industry leader, to provide your family with many years of reliable comfort and trouble-free performance. The care and maintenance of your new boiler is important to prevent a hazardous condition which might result form lack of proper servicing. Therefore, you should perform regular owner inspections as described in this manual (and report any concerns to a qualified service technician) as well as have your boiler serviced by a qualified service technician at least once a year, preferably before the beginning of each heating season. LIGHTING INSTRUCTINS Locate, read and then follow the procedures on the lighting instructions label attached to the boiler. For reference, we have reproduced those instructions in this manual. D NT use this boiler if any part has been underwater. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been underwater. WARNING Should overheating occur or the gas supply fail to shut off, D NT turn off or disconnect the electric supply to the circulator pump. Instead, shut off the gas supply at a location EXTERNAL to the appliance. WARNING SLANT/FIN DES NT PERMIT THE USE F VENT DAMPERS N VICTRY SERIES BILERS. THER DAMPERS R DEVICES WITH SIMILAR PURPSE ARE NT PERMITTED. Keep the boiler area clean and free of all materials that can burn. NEVER close or reduce openings that supply air for the boiler fire and for ventilation.

3 VICTRY VSPH Models INSPECTIN Your boiler and heating system will last an indefinitely long time at full efficiency, if it is inspected regularly and is kept in good repair and adjustment. You, the user, should make regular inspections, and report any problems to your service agency. At regular intervals, you should have that agency inspect the system, clean the boiler and make repair adjustments as necessary. what you and the service agency should do is listed below. Contact your gas supplier for a list of qualified service and repair agencies. USER INSPECTIN The user should make the following inspections at least once each month during the heating season and once just before cold weather starts. VSPH boilers maybe installed and vented either as direct-vent boiler, which all air for combustion is obtained directly from outside through the air intake piping or as non-direct-vent boiler, which all air for combustion is taken from inside the boiler room. Typical direct-vent installations are shown on FIgures 2 and 3. Non-direct-vent installation is shown on Figures 4, 5 and 6. 1. VENTING AND AIR INTAKE SYSTEM REGULAR INSPECTIN Inspect the system regularly for condensation, corrosion and/or physical damage. A qualified professional should service the boiler annually and include such an inspection at that time. The homeowner should look over the system monthly for damage, water stains, any signs of rust, other corrosions or separation of the vent and air intake piping (if direct-vent). Figure 3. Should an inspection turn up signs of condensation, corrosion or damage, the boiler should be shut down immediately and the condition should be corrected by a qualified professional. If the boiler is vented horizontally through the wall, the outside termination, louvers and screen should be checked for any debris blocking the opening and cleaned as required. Figure 2.

VICTRY VSPH Models 4 Figure 4. Figure 5.

5 VICTRY VSPH Models Figure 6. 2. CNDENSATIN DRAIN All Victory VSPH boilers are equipped with a built-in condensation drain and trap. The trap loop must be filled with water. D NT operate the boiler without filling the trap with water to prevent flue gas discharge into space. Periodic inspection should be made of this assembly for deterioration of the tubing and to insure that the trap is not plugged. If it is plugged or appears to have excessive sediment in it, it should be removed from the drain assembly, straightened out to clear the obstruction, reformed, filled with water and reinstalled as before. 3. PIPING INSPECTIN Look at all water piping. There should be no leaks or signs of leaks at any pipe joints or around the boiler. 4. SYSTEM WATER PRESSURE INSPECTIN The temperature and pressure gauge indicates the pressure in the boiler at each water temperature. For most installations, it should indicate about 12 to 15 psi pressure when temperature is about 70 to 100F and from 15 psi to 25 psi when temperature is up to 240F. FR YUR SYSTEM, there is one correct pressure for each temperature. ASK YUR INSTALLER R SERVI- CEPERSN T EXPLAIN AND SHW YU. Learn what normal pressure to look for. If pressure rises from normal, the relief valve will open to relieve the pressure. Call your service organization if pressures are higher or lower than normal, and if the relief valve spills water. Repair or adjustment is needed. 5. UNUSUAL NISE Stand near the boiler and look and listen. As the burners start and shut off, there should be no unusual noise. 6. BILER RM AIR SUPPLY Ample boiler room fresh air is required for combustion (non-direct vent installation) and ventilation (direct-vent installation). Check air vents for continuous positive supply of air as required. Air needs are greatest in cold weather if boiler installation is non-direct vent method. Air vents must be open and free of obstruction. Warning: The flow of combustion and ventilating air to the boiler should not be obstructed. Warning: If you find any problem during your inspection, call for service immediately.

VICTRY VSPH Models 6 ANNUAL SERVICE AND GENERAL MAINTENANCE A trained and qualified service technician should perform inspection and general maintenance listed in Installation and perating Instructions (Publication No. VSPH-40) before each heating season and at regular intervals. SAFETY AND PERATING INSTRUCTINS Follow the lighting instructions in this manual. These instructions are also attached to the boiler. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. SAFETY INFRMATIN For Your Safety Read Before perating A. This appliance is equipped with an ignition device which automatically lights the pilot. D NT try to light the pilot by hand. mation above on this page. If you don t smell gas, go to next step. 8. Turn as control knob counterclockwise to N. 9. Replace jacket front panel. 10.Turn on all electric power to the appliance. 11. Set thermostat to desired setting. 12. If the appliance will not operate, follow the instructions To Turn ff Gas to Appliance and call your service technician or gas supplier. To Turn ff Gas to Appliance 1. Set thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Remove jacket front panel. 4. Turn gas control knob clockwise till knob stops, then continue to FF. Do not force. 5. Replace jacket front panel. Gas Valve VR8204 or VR8304 B. BEFRE PERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT T D IF YU SMELL GAS: D NT try to light any appliance. D NT touch any electric switch: D NT use any phone in your building. Immediately call you gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, don t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. D NT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. PERATING INSTRUCTINS 1. STP! Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. D NT try to light the pilot by hand. 5. Remove jacket front panel 6. Turn gas control knob clockwise to FF. D NT force. 7. Wait five (5) minutes (longer for propane) to clear out any gas, then smell for gas, including near the floor. If you then smell gas, STP! Follow B in the safety infor Figure 7. Removing Jacket Front Panel 1. Turn black screws 1 4 turn to open position. 2. Remove front panel. To replace the panel, reverse procedure. INTEGRATED BILER CNTRL The integrated boiler control monitors the status of the room thermostat, high limit control (Aquastat), pressure switch (air flow proving switch) and the flame sensor. It controls the operation of the circulator, inducer motor (blower), gas valve and spark for pilot ignition. The boiler control also determines the sequence of operation and timing for pre and post purge periods, trial for ignition adn lockout. The control indicator lights ( s) provide information of boiler operation when lights are steady on or diagnostic information when they are flashing in order to help to determine the cause of boiler failure.

7 VICTRY VSPH Models INTEGRATED BILER CNTRL Flame (Red) Pressure Switch (Red) Hi Limit (Red) Thermostat/Circ. (Red) Power (Green) Figure 8.

VICTRY VSPH Models 8 A. NRMAL PERATIN - STATUS F INDICATR LIGHTS ( S) = off = steady on DESCRIPTIN F PERATIN Standby-Boiler waits for call for heat PWER TSTAT/CIRC LIMIT PRESS SWITCH FLAME Thermostat calls for heat Circulator on Boiler water temperature below high limit setting Inducer on Pressure switch contacts closed 30 seconds pre-purge period Trial for ignition Gas valve open Pilot flame and main burners on Boiler heating period Thermostat call for heat ends Circulator off 15 seconds post purge period. Burners off. B. DIAGNSTIC FLASH CDES Flashing s provide diagnostic information WARNING: nly a trained, experienced service technician should perform troubleshooting. Turn off all electric power to the boiler before service s FLASHING INDICATIN REMEDY PWER * 120 V power supply. Polarity is reversed Reverse Hot and NEUTRAL wires in the junction box. PWER + TSTAT/CIRC S * 48 VAC on thermostat circuit. Check and correct the thermostat or zone valves wirings. PWER + PRES SWITCH S * Pressure switch contacts are closed prior to Check air pressure switch. energizing the blower motor or does not close Check hose connections to pressure switch. within 5 minutes of the blower being turned on. Check for obstruction/restriction in venting, air intake piping and termination. PWER + FLAME S * Flame sensed without call for heat. Remove air box front panel. Turn off power for at least 45 seconds. Check if pilot flame exists during pre-purge period (first 30 seconds). If pilot flame exists, replace gas valve FLAME * Pilot flame was not established during trial for Check gas valve knob to be in N position. ignition. Check inlet gas pressure. Check pilot gas line. Check ignition cable and the connections. Check pilot flame to be to 1/2" long PRES SWITCH Pressure switch opened during boiler run Check pressure switch and its hoses. period. Wind gusts over 40 mph. Check for obstruction in venting, air intake piping and termination. * Control Lockout Slant/Fin Corp. 2015 SLANT/FIN CRPRATIN, Greenvale, N.Y. 11548 Phone: (516) 484-2600 FAX: (516) 484-0933 Canada: Slant/Fin LTD/LTEE, Mississauga, ntario www.slantfin.com