Norminal Sprinkler Temperature Rating

Similar documents
SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

Norminal Sprinkler Temperature Rating

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

DISCONTINUED PRODUCT

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

DISCONTINUED PRODUCT. reference publication

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

FLUSH HORIZONTAL SIDEWALL

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

micromatic Standard response Horizontal Sidewall sprinkler

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

esfr pendent sprinkler vk510 (k25.2)

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Sprinkler Identification Numbers

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

Sprinkler Identification Numbers

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

TECHNICAL DATA NOTICE

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

esfr pendent sprinkler vk510 (k25.2)

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA. Page 1 of 6

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

esfr dry pendent sprinkler Vk502 (k14.0)

Automatic Sprinklers

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

Submittal Packages Detailed with Items and Reviewers

Model/Sprinkler Identification Numbers

SENJU SPRINKLER CO., LTD.

esfr dry pendent sprinkler Vk501 (k14.0)

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Sprinkler Identification Number (SIN)

microfast quick response extended coverage hsw sprinkler vk606

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Microfast quick response Fusible element hsw sprinkler

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

Transcription:

SPRINKLER HEAD Horizontal Sidewall Sprinkler MODEL: SD1133, SD1121 DESCRIPTION The SD1133, SD1121, ½ orifice, standard horizontal sidewall sprinkler is designed for standard or recessed installation. The design provides a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings and finishes to meet many design requirements. The recessed pendent should be utilized with a recessed escutcheon which provides up ¾ of adjustments. SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand. When the ambient temperature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. MAXIMUM COVERAGE Standard spray coverage is up to: Light Hazard = 196 square feet(18,2 sq.m); Ordinary Hazard = 100 square feet(9,3 sq.m)per NFPA 13. TECHNICAL SPECIFICATION Sprinkler Identification Number Standard SD1133 (bulb 5mm), Quick Response SD1121 (bulb 3mm) Style Horizontal Sidewall K Factor 5.6gpm/psi ½. (80lpm/bar ½ ) Response Time Index (RTI) Nominal Thread Size Orfice Size Max. Working Pressure Factory Hydrostatic Test Min. Operation Pressure Standard 50 Quick Response 30 ½ NPT(15mm) 13mm 175PSI(1200kPa) 100%@500PSI(3450 kpa) 7 PSI(48 kpa) RATINGS Sprinkler Temperature Classification Norminal Sprinkler Temperature Rating N.F.P.A Maximum Ambient (Ceiling) Temp.(Allowed) Glass Bulb Color Ordinary 155ºF/57ºC 100ºF/38ºC Orange Ordinary 155ºF/68ºC 100ºF/38ºC Red Intermediate** 175ºF/79ºC 150ºF/65ºC Yellow Intermediate** 200ºF/93ºC 150ºF/65ºC Green High* 286ºF/141ºC 225ºF/107ºC Blue Extra High* 360ºF/182ºC 300ºF/149ºC Mauve Open* Open - No Bulb * Non-Approved ** FM Approved only 11

PART LIST SD1133 SD1121 1. Frame 2. Deflector 3. Cap 4. Cap Seat 5. Load Screw 6. Seal 7. Bulb DISCHARGE CURVE 12

WARNINGS The SHIELD sprinklers must be installed and maintained in compliance with this document. Depressurize and drain the piping system before attempting to install, remove, or adjust any Sprinklers. Failure to do so may impair the performance of these sprinklers. The owner is responsible for maintaining the fire protection system and devices in operation. WRENCH DESCRIPTION The Sprinkler Wrench is a tool specifically designed for installing SHIELD Sprinklers. These special wrenches must be used to provide the proper leverage when tightening the sprinkler and to minimize slippage during installation. Any other wrench may damage the sprinkler. INSTALLATION SEQUENCE Step 1. The unit must be installed in the horizontal sidewall position for the Horizontal Sidewall Sprinklers. Step 2. Use only a non-hardening pipe joint compound or tape seal. Apply only to the male threads. Step 3. Hand tighten the sprinkler into fitting. Step 4. For Horizontal Sidewall Sprinklers, use a standard wrench. Tighten the unit into the fitting. A leadtight joint requires only 7 to 14ft.-lbs(9.5 to19.0nm) of torque. A tangential force of 14 to28ft.-lbs(62.3 to 124.5N) delivered through a6 (150mm) handle will deliver adequate torque. Once torque level reach over 21ft.-lbs(28.6Nm) it may distort the orifice seal, resulting in leakage. For exposed piping systems, the sprinkler should be oriented so the frame arms are parallel with the branch line pipe. CAUTION Sprinkler Wrench INSTALLATION All SHIELD Sprinklers must be installed according to NFPA 13 Standards. Deviations from these requirements and standards or any alteration to the sprinkler itself will void any warranty made by manufacturer. In addition, installation must also meet local government provisions, codes and standards as applicable. The system piping must be properly sized to insure the minimum required flow rate at the sprinkler. Check for the proper model, style, orifice size and temperature rating prior to installation. Install sprinklers after the piping is in place to avoid mechanical damage, replace any damaged units. Wet pipe systems must be protected from freezing. Upon completion of the installation, the system must be tested per recognized standards. In the event of a thread task, remove the unit, apply new pipe joint compound or tape, and reinstall. Do not over-tighten or under-tighten the sprinkler to compensate for inaccurate escutcheon plate adjustment. Protection clips are used to protect its bulb. Please have clip on at all times during transportation. MAINTENANCE Sprinklers must never be altered after manufacture. Any alteration such as painting and coating will directly harm the sprinkler and cause malfunctions. Sprinkler in contact with corrosive products should be replaced if they cannot be cleaned completely. Visual inspections are recommended after installation. After installation, a close-up inspection annually will suffice. Inspection and maintenance of fire protection system is the responsibility of the owner. It is recommended that automatic sprinkler system be inspected and tested according to local and/or national regulations. ADDITIONAL Recessed Sprinkler - To install the escutcheon plate, align with it and push or thread over the sprinkler body into the upper support piece, until the outer edge of the escutcheon meets the mounting surface. 13

DISTRIBUTION PATTERNS K5.6 STANDARD HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - TRAJECTORY K5.6 STANDARD HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS PLAN VIEW 14

DIMENSIONS RECESSED PENDENT SPRINKLER Maximum Extension Maximum Recess 15