Radon Detection Specialists, Inc. Love the Lungs You re With

Similar documents
Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Certificate of Completion

Certificate of Completion

Certificate of Completion

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Illinois School District & Daycares

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

Illinois School District & Daycares

Comprehensive Short-Term Radon Survey Report

RADON LAZERWEB SERVICES

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

Woodlin Elementary School Date of Report March 14, 2018

Buying a New Home? How to Protect Your Famil... Page 1 of 6

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Dealing With RADON in Real Estate Transactions

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

radon Keeping your home safe from radon

Illinois Emergency Management Agency

Bethel School District Radon Testing Plan

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

In Schools. Revised Edition. oepa. Aa Bb Cc Dd Ee Radon Measurement. Air And Radiation (6604J)


Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

RULES AND REGULATIONS FOR RADON CONTROL

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

Dealing With RADON in Real Estate Transactions

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

ALL RADON TESTS WERE SIGNIFICANLY BELOW

Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM

A Citizen s Guide To Radon

2.3 Definitions, General Provisions, and Radon Standards

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

Radon. In Your Home SAMPLE

Measurement Devices. Topic 5 - Audio 56

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

Radon Measurement Report

Radon YOU: What you need to know to protect you and your family

Radon Environmental Health Program Health Canada, Alberta Region. Bradley Hameister October 4, 2011

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

C-NRPP Quality Assurance Guidance for Radon Test Devices

MAKE MOLD UNWELCOME IN YOUR HOME

Special Attention of: Notice H All Multifamily Hub Directors All Program Center Directors All Project Managers All Field Office Directors

REAL ESTATE TRANSACTIONS

REAL ESTATE TRANSACTIONS

YOU: What you need to know to protect you and your family

Multnomah Education Service District

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

CHAPTER 240. RADON CERTIFICATION

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

EagleRidge High School. Radon Testing Plan

NSAW Radon Assessment 2017 QUESTIONS AND ANSWERS

A Citizen s Guide To Radon The Guide To Protecting Yourself And Your Family From Radon

Consumer s Guide To Radon Reduction

Property of Aztec Home Services LLC

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON?

Guide for Radon Measurements in Residential Dwellings (Homes)

Radon Survey Final Report

Testing for Elevated Radon in Oregon Schools

Testing for Elevated Radon in Oregon Schools

Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48

Home Buyer s and Seller s Guide to Radon

RADON SCREENING SURVEY FOLLOW-UP SPRINGBROOK HIGH SCHOOL

Testing for Elevated Radon in Oregon Schools Protocol and Plan

EPA estimates that radon causes thousands of lung cancer deaths in the U.S. each year.

Public Review: MAMF - Proposed Revision 09/2016. Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily Buildings

AVERAGE RADON CONCENTRATION:

Radon Survey Summary Report

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664

What you need to know

RADON: IS IT IN YOUR HOME?

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration.

Kansas Radon Program Newsletter

Property Inspected: 623 Pine St, Macon, GA 31201

Locations must be selected where the detector is not to be disturbed during the measurement period.

Consumer s Guide To Radon Reduction How to fix your home

A Citizen s Guide To Radon

Home Buyer s and Seller s Guide to Radon

Connecticut Radon Measurement Training Program

Home Buyer s and Seller s Guide to Radon

RADON: IS IT IN YOUR HOME?

RADON. In Search of Answers

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS

A Homeowner s Guide to Radon

Transcription:

630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: October 20 2014 to October 22, 2014 Continued Diagnostic Measurement Partial Foundation Retest, Post HVAC Balancing RDS-R-002 Prepared by: Kirsten Schmidt IL Professional Radon License RNI2006204 Licensed for Residential and Commercial Radon Testing

8100 School Street, La Grange, Illinois 60525 Survey Date: 10/20/14 to 10/22/14 Table of Contents Basics of Radon and Radon Health Impacts... 3 Scope of Work Performed:... 4 Quality Assurance Plan for this Site... 5 Explanation of Device Results and Site Notes... 6 Survey Summary... 7 Appendix A: Site Plan Showing Device Locations... 9 Appendix B: Individual Device Results Table... 10 Appendix C: IEMA Radon Measurement Professional License... 12

Survey Date: 10/20/14 to 10/22/14 page 3 of 12 Basics of Radon and Radon Health Impacts Radon is recognized by the United States Environmental Protection Agency (US EPA) as well as the scientific and medical communities as a Class A carcinogen, accounting for 15,000 22,000 lung cancer deaths annually. Exposure to radon gas is the leading cause of lung cancer among non-smokers. Radon is a naturally occurring, radioactive gas which comes from the soil. It can t be seen, smelled or tasted. The only way to know if the level of radon gas in your building exceeds the recommended action level of 4.0 pci/l is to test. The Department of Nuclear Safety in Illinois requires those testing for radon in commercial buildings, schools and multi-family housing communities, as well as individual residences, to be licensed. The amount of radon in the soil depends on soil chemistry, which naturally varies. Radon levels in the soil can range from a few hundred to several thousands of pci/l (pico Curies per liter of air). The amount of radon that escapes from the soil and enters the building depends on the weather, soil porosity, soil moisture, and the suction within the building. Radon is the leading cause of lung cancer among non-smokers. There is no safe level of radon exposure. Any exposure causes some risk of developing cancer. In two 1999 reports, the National Academy of Sciences (NAS) concluded after an exhaustive review that radon is the second leading cause of lung cancer. Only cigarette smoking poses a greater risk. The NAS estimates that 15,000 to 22,000 Americans die every year from radonrelated lung cancer. That s 10% of all lung cancer deaths annually. The alpha radiation from radon and its decay products cause damage to the sensitive lung tissue. Most of the radiation dose is not actually from radon itself, but rather from radon s chain of short-lived decay products that are inhaled and lodge in the airways of the lungs. These radionuclides decay quickly, producing other radionuclides that continue damaging the lung tissue. Those particles that are retained long enough release radiation and damage the surrounding lung tissue. It is this damage that can lead to lung cancer. What other health risks are related to radon exposure? No other respiratory ailments are linked to radon exposure There are preliminary studies that are looking at the link between radon exposure and the development of Parkinson s and Alzheimer s disease. These are early studies. For more information on this issue, please visit our website and read the press release.

Survey Date: 10/20/14 to 10/22/14 page 4 of 12 Scope of Work Performed: At the request of Catherine Chang, continued to perform a partial foundation, diagnostic measurement, post HVAC balancing at Pleasantdale Elementary, located at 8100 School Street, in LaGrange. This scope of work included a continued 2 day (short-term) diagnostic measurement in twelve locations which demonstrated elevated radon levels during the 14 day measurement taken from September 22, 2014 to October 6, 2014. A total of 12 continuous radon monitors were deployed for this diagnostic measurement. Testing was conducted from Monday, October 20, 2014 to Wednesday, October 22, 2014. The devices were continuous radon monitors manufactured by Sun Nuclear, model 1027. Because radon levels fluctuate hourly, daily, weekly, seasonally and yearly, these results should not be used to estimate radon levels of rooms that were not tested, or to estimate future radon levels of rooms that were tested. Changes to the building components (both structural and mechanical) can effect radon concentrations. Duplicate devices have been averaged together and demonstrate the precision of the measurements. The testing was conducted in accordance with the Illinois Emergency Management Agency Division of Nuclear Safety (IEMA) and the United States Environmental Protection Agency (USEPA) testing protocols for commercial radon measurements, the device manufacturer s recommendations, and the RDS Quality Assurance Plan.

Survey Date: 10/20/14 to 10/22/14 page 5 of 12 Quality Assurance Plan for this Site Pre-Deployment Testing Strategy Continued testing will be conducted in twelve locations which demonstrated elevated levels during the 14 day measurement period from September 22, 2014 to October 6, 2014. Materials and Methods RDS will deploy continuous radon monitors to measure radon levels in the air in the above referenced property on an hourly basis during the measurement period. The test will comply with all protocols set forth by IEMA, as well as the RDS Quality Assurance Plan presently on file with the state. RDS will locate devices in such a way to limit unintentional interference from building occupants. Test results will be reported in picocuries per liter (pci/l) of air. The effects of the HVAC system on radon progeny will not be evaluated and working level exposure (WL) will not be calculated during this test.

Survey Date: 10/20/14 to 10/22/14 page 6 of 12 Explanation of Device Results and Site Notes Appendix A provides a detailed drawing showing device locations, if an appropriate and accurate drawing is provided by the client and dimensional device plotting is possible. If Appendix A is blank, please refer to the Device Placement columns provided in Appendix B (Room Use and Room Number) as an explanation of device locations. Appendix B identifies all of the devices deployed and their reported radon levels. The results were determined using calculations supplied by the device manufacturer. The average of the radon levels detected during this short-term diagnostic measurement were BELOW the recommended Action Level of 4.0 pci/l in all twelve of the locations measured. All radon levels are expressed in picocuries per liter (pci/l) of air. The building was tested according to IEMA, and USEPA protocol in regard to device placement and analytical methods of calculating results. Tampering was not detected at the time the devices were retrieved, unless noted in the Comment Column. Devices were placed strategically to reduce accidental interference by building occupants. Duplicates are averaged together. It is the average of the two devices upon which decisions with regard to mitigation should be based. Please See Appendix B for duplicate measurement calculations. Site Notes: 1. Although the subject building was occupied and fully-functional during this partial foundation, diagnostic radon measurement, post HVAC balancing, the twelve subject classrooms were not being used by students or staff. 2. The amount of fresh air being incorporated into the building post HVAC balancing was reported to be at 40% during this measurement. 3. This measurement is considered diagnostic in nature because only a limited portion of the subject building was measured during this round of testing.

Survey Date: 10/20/14 to 10/22/14 page 7 of 12 Survey Summary The average radon levels found during this short-term diagnostic measurement were BELOW the USEPA and IEMA Action Level of 4.0 pci/l in all locations tested. Recommendations 1. Continue to ensure sufficient engineering controls are in place and are properly documented to keep the HVAC system running 24 hours a day, 7 days a week, without regard to weekend and holiday hours. 2. Continue to monitor the hourly radon levels in these twelve locations for another 90 hours. 3. If average radon levels continue to be below the Action Level of 4.0 pci/l in these twelve locations, and an intake of 40% fresh air on a regular basis is determined to be either the new normal HVAC operating status or a temporary radon reduction measure, a short-term radon measurement should be performed throughout the full building to ensure that inadvertent pressure changes haven t been made in other areas of the subject building. 4. If the short-term, full-building radon measurement demonstrates average radon levels throughout the building to be below the Action Level of 4.0 pci/l,and incorporating 40% fresh air is determined to be the new normal HVAC operating status, a long-term, full building radon measurement will be recommended. 5. If incorporating 40% fresh air is determined to not be the new normal HVAC operating status, continued consultation with an Illinois licensed commercial radon mitigation firm will provide information with regard to long-term radon management techniques.

Survey Date: 10/20/14 to 10/22/14 page 8 of 12 Radon Detection Specialists is licensed for both residential and commercial radon testing in Illinois. For more information regarding radon testing and mitigation practices in the state of Illinois, please visit the Illinois Emergency Management Agency Department of Nuclear Safety s website, www.radon.illinois.gov, or call the state of Illinois Radon Program at 217-782-1325.

Survey Date: 10/20/14 to 10/22/14 page 9 of 12 Appendix A: Site Plan Showing Device Locations For General Reference Only 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com

Survey Date: 10/20/14 to 10/22/14 page 10 of 12 Appendix B: Individual Device Results Table CRM Device Placement Start Stop Exposure Period Radon Level Control Measurement Duplicate Device Avg. Radon Level Comments Foundation Room Use Room No. Date Time Date Time Days (pci/l) Duplicate/ Blank (pci/l) 3560 Classroom 144 10/20/14 10:40 3:21 pm 0.5 4560 Classroom 142 10/20/14 10:42 3:37 pm 0.6 17460 Small Classroom 141 10/20/14 10:44 3:32 pm 1.1 14160 Classroom 139 10/20/14 10:46 3:37 pm 0.4 15960 Classroom 138 10/20/14 10:47 3:43 pm 1.4 4860 Classroom 136 10/20/14 10:48 3:48 pm 1.7 9560 Small Classroom 130 10/20/14 10:49 3:53 pm 1.3 10960 Classroom 124 10/20/14 10:50 3:57 pm 1.1 12760 Small Classroom 105 10/20/14 10:55 4:02 pm 1.6 21260 Classroom 111 10/20/14 11:00 All radon levels are expressed in picocuries per liter (pci/l). Results of duplicate devices are averaged to determine the radon level in that location. 4:06 pm 0.3 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com

Survey Date: 10/20/14 to 10/22/14 page 11 of 12 Appendix B: Individual Device Results Table CRM Device Placement Start Stop Exposure Period Radon Level Control Measurement Duplicate Device Avg. Radon Level Comments Foundation Room Use Room No. Date Time Volts Date Time Volts Days (pci/l) Duplicate/ Blank (pci/l) 10060 Gym 108 10/20/14 11:05 4:10 pm 0.3 5660 Principal 10/20/14 10:35 3:05 pm 1.0 All radon levels are expressed in picocuries per liter (pci/l). Results of duplicate devices are averaged to determine the radon level in that location. 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com

Survey Date: 10/20/14 to 10/22/14 page 12 of 12 Appendix C: IEMA Radon Measurement Professional License 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com