CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

Similar documents
CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel"

We Identify and S.T.O.P. Your Noise Problems

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

SIGMADEK, LTD. FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Acoustical Surfaces, Inc.

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

GUARDIAN FIRE TESTING LABORATORIES, INC.

Report of Surface Burning Characteristics Test on Acoustical Panel

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

Public Comment No. 2-NFPA [ Section No ]

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

ISO INTERNATIONAL STANDARD

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

IMO Resolution MSC 61(67): Annex 1: Part 2

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Materials Testing by Gregory Havel

BS EN ISO : 2010

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Report VNLF Test Report

BS EN ISO : 2010

Test Report: ICL/H18/9039 Rev 1

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS 476: Part 6: 1989+A1:2009

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

An experimental study of the impact of tunnel suppression on tunnel ventilation

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

BS EN ISO : 2010

BCTC CARPET TECHNICAL CENTRE

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS 476: Part 6: 1989+A1:2009

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

TFI Report Reaction to fire test

CLT Adhesive Tests in Support of Mass Timber Buildings

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

Classification of Fire Performance of Wall and Ceiling Lining Materials

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

NATIONAL TECHNICAL SYSTEMS

New European Fire Testing Classification for Construction Products

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

Abrasion Resistance of Fluoropolymer and polyester Coatings

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

This document is a preview generated by EVS

NF X : Parts 1, 2, 3, 4 & 5

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

C-01 FIRE DECKS AND BULKHEADS

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Review Fire Test Report

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Determination of Fire Exposure Heat Flux in Cable Fire Tests

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Transcription:

ELECTRONIC DRAFT COPY CAN/ULC-S12 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" A Report To: ABET Corporation 5 Paxman Road, Unit 1 Toronto, Ontario M9C 1B7 Phone: 416-71-4912 E-mail: sgregory@abetlaminati.com Attention: Sean Gregory Submitted by: Fire Testing Report No. 12-2-278 6 Pages Date: April 17, 212

CAN/ULC-S12-1 Testing of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" Page 2 of 6 For: ABET Corporation Report No. 12-2-278 ACCREDITATION To ISO/IEC 1725 for a defined Scope of Testing by the International Accreditation Service SPECIFICATIONS OF ORDER Determine the Flame Spread and Smoke Developed Classifications based upon triplicate testing conducted in accordance with CAN/ULC-S12-1, as per Warringtonfire North America Quotation No. 12-2-351 accepted April 2, 212. SAMPLE IDENTIFICATION ( sample identification number 12-2-S278) High Pressure Laminate Panel System identified as: "8 mm Fire Rated High Pressure Laminate Phenolic Panel" TEST PROCEDURE The method, designated as CAN/ULC-S12-1, "Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies", is designed to determine the relative surface burning characteristics of materials under specific test conditions. Results of less than three identical specimens are expressed in terms of Flame Spread Value (FSV) and Smoke Developed Value (SDV). Results of three or more replicate tests on identical samples produce average values expressed as Flame Spread Rating (FSR) and Smoke Developed Classification (SDC). Although the procedure is applicable to materials, products and assemblies used in building construction for development of comparative surface spread of flame data, the test results may not reflect the relative surface burning characteristics of tested materials under all building fire conditions. SAMPLE PREPARATION Each test sample consisted of a total of 3 sections of material, each approximately 8 mm in thickness by 533 mm in width. For each test, two sections were approximately 348 mm in length and one section was approximately 1219 mm in length. The sections were butted together to form the requisite specimen size. Since no specific definition, procedure or criteria are provided in CAN/ULC-S12-1 with regard to determining "constant mass" (as stated in section 6.2), each sample was conditioned at a temperature of 23 ± 3 C and a relative humidity of 5 ± 5% for a minimum period of 24 hours prior to testing. During testing the samples were self-supporting. The testing was performed on: Test #1: 212-4-1 Test #2: 212-4-1 Test #3: 212-4-1 SUMMARY OF TEST PROCEDURE The tunnel is preheated to 85 C, as measured by the backwall-embedded thermocouple located 79 mm downstream of the burner ports, and allowed to cool to 4 C, as measured by the backwall-embedded thermocouple located 4 mm from the burners. At this time the tunnel lid is raised and the test sample is placed along the ledges of the tunnel so as to form a continuous ceiling 7315 mm long, 35 mm above the floor. The lid is then lowered into place.

CAN/ULC-S12-1 Testing of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" Page 3 of 6 For: ABET Corporation Report No. 12-2-278 SUMMARY OF TEST PROCEDURE (continued) Upon ignition of the gas burners, the flame spread distance is observed and recorded every 15 seconds. Flame spread distance versus time is plotted, ignoring any flame front recessions. Calculations are based on comparison with flame spread characteristics of select red oak, determined in calibration trials and arbitrarily established as 1. If the area under the curve (A) is less than or equal to 29.7 m min, FSV = 1.85 A; if greater, FSV = 164/(59.4-A). The Smoke Developed Value is determined by comparing the area under the obscuration curve for the test sample to that of inorganic reinforced cement board and red oak, established as and 1, respectively. TEST RESULTS SAMPLE FSV SDV "8 mm Fire Rated High Pressure Laminate Phenolic Panel" Test #1 13 72 Test #2 11 55 Test #3 12 87 Average: 12 71 Rounded Average Flame Spread Rating (FSR): 1 Rounded Average Smoke Developed Classification (SDC): 7 Observations of Burning Characteristics - The test samples ignited approximately 1 to 1.25 minutes after exposure to the test flame. Blistering, delamination and spalling behavior was observed prior to ignition. - The flame fronts advanced to maximum distances of 1.4, 1.4, and 1.5 metres at approximately 9, 9.5, and 9.75 minutes into each respective test. - Smoke Developed and temperature were recorded during the tests (see accompanying charts). Note: This is an electronic copy of the report. Signatures are on file with the original report. Robert A. Carleton, Fire Testing. Ian Smith, Fire Testing. Note: This report and service are covered under Canada Inc. Standard Terms and Conditions of Contract which may be found on the website (www.exova.com), or by calling 1-866-263-9268.

CAN/ULC-S12-1 Testing of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" Page 4 of 6 For: ABET Corporation Report No. 12-2-278 :"8 mm Fire Rated High Pressure Laminate Phenolic Panel" Test #1 of 3 6 FLAME SPREAD Flame Spread in Metres 5 4 3 2 1 Red Oak (FSV=1) % Light Absorption 1 9 8 7 6 5 4 3 2 1 Red Oak (SDV=1) SMOKE DEVELOPED 4 TEMPERATURE Temperature ( C) 3 2 1 FSV SDV Max. Temp. ( C) 13 72 348

CAN/ULC-S12-1 Testing of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" Page 5 of 6 For: ABET Corporation Report No. 12-2-278 :"8 mm Fire Rated High Pressure Laminate Phenolic Panel" Test #2 of 3 6 FLAME SPREAD Flame Spread in Metres 5 4 3 2 1 Red Oak (FSV=1) % Light Absorption 1 9 8 7 6 5 4 3 Red Oak (SDV=1) SMOKE DEVELOPED 2 1 4 TEMPERATURE Temperature ( C) 3 2 1 FSV SDV Max. Temp. ( C) 11 55 349

CAN/ULC-S12-1 Testing of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" Page 6 of 6 For: ABET Corporation Report No. 12-2-278 :"8 mm Fire Rated High Pressure Laminate Phenolic Panel" Test #3 of 3 6 FLAME SPREAD Flame Spread in Metres 5 4 3 2 1 Red Oak (FSV=1) 1 SMOKE DEVELOPED % Light Absorption 9 8 7 6 5 4 3 2 1 Red Oak (SDV=1) 4 TEMPERATURE 3 Temperature ( C) 2 1 FSV SDV Max. Temp. ( C) 12 87 35