Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

We Identify and S.T.O.P. Your Noise Problems

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

SIGMADEK, LTD. FIRE TEST REPORT

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel"

Acoustical Surfaces, Inc.

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Report of Surface Burning Characteristics Test on Acoustical Panel

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

FUNDERMAX GMBH FIRE TEST REPORT

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

GUARDIAN FIRE TESTING LABORATORIES, INC.

BCTC CARPET TECHNICAL CENTRE

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Report VNLF Test Report

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

Materials Testing by Gregory Havel

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Test Report: ICL/H18/9039 Rev 1

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

Classification of Fire Performance of Wall and Ceiling Lining Materials

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

Public Comment No. 2-NFPA [ Section No ]

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

An experimental study of the impact of tunnel suppression on tunnel ventilation

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

ISO INTERNATIONAL STANDARD

Determination of Fire Exposure Heat Flux in Cable Fire Tests

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

APPLICATION FOR FIRE CERTIFICATE / FIRE CLEARANCE UNDER THE MAURITIUS FIRE AND RESCUE SERVICE ACT 2013 OFFICE USE ONLY

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

C-NRPP Quality Assurance Guidance for Radon Test Devices

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

Report Test Report

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Fire resistance test on fire collars protecting a concrete slab penetrated by services

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

Abrasion Resistance of Fluoropolymer and polyester Coatings

New European Cable Testing and Classification

New European Fire Testing Classification for Construction Products

For Salisbury by Honeywell

BUILDING CODE COMMISSION

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

NBS Smoke Density Chamber

This document is a preview generated by EVS

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

PROFIRE BMS Controller

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

Report On Surface Burning Characteristics Determined By. PREPARED FOR: Forbo Linoleum, Inc. Hazelton, Pennsylvania TEST NUMBER T-21906

Building and Development

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

BS EN ISO : 2010

An accredited Tester Laboratory registered at Nr. NAT /2010 by NAT. No.: M 398/2011 Date: 31. August Test report

Transcription:

ELECTRONIC DRAFT COPY CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" A Report To: Polygal Plastics Industries, Ltd. Ramat Hashofet 19238 Israel Phone: 972-4-9596271 Email: ward@polygal.com Attention: Ward C. Ogle Submitted by: Fire Testing Report No. 9-2-494(C) 6 Pages Date: July 16, 29 Bodycote Testing Group 2395 Speakman Drive Mississauga Ontario Canada L5K 1B3 Tel: +1 (95) 822-4111 Fax: +1 (95) 823-1446

CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" Page 2 of 6 For: Polygal Plastics Industries, Ltd. Report No. 9-2-494(C) ACCREDITATION Standards Council of Canada, Registration #1. SPECIFICATIONS OF ORDER Determine the Flame Spread and Smoke Developed Classifications based upon triplicate testing conducted in accordance with CAN/ULC-S12.2-7, as per our Quotation No. 9-2-4374 RV2 accepted July 2, 29. SAMPLE IDENTIFICATION Polycarbonate material identified as: "POLPC16/2.7CX/CLR16, clear Polycarbonate Multiwall sheet 16 mm". TEST PROCEDURE (Bodycote sample identification number 9-2-S494-3) The method, designated as CAN/ULC-S12.2-7, "Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Covering and Miscellaneous Materials", is designed to determine the relative burning characteristics of materials under specific test conditions. Results of less than three identical specimens are expressed in terms of Flame Spread Value (FSV) and Smoke Developed Value (SDV). Results of three or more replicate tests on identical samples produce average values expressed as Flame Spread Rating (FSR) and Smoke Developed Classification (SDC). Although the procedure is applicable to materials, products and assemblies used in building construction for development of comparative surface spread of flame data, the test results may not reflect the relative surface burning characteristics of tested materials under all building fire conditions. SAMPLE PREPARATION The specimens were free-laid on 6 mm thick, fiberglass reinforced cement board. Each specimen consisted of 3 sections of material, each approximately 2438 mm in length by 533 mm in width by 16 mm in thickness butted together to form the requisite specimen length. Prior to testing, the samples were conditioned at a temperature of 23 ± 3 C and a relative humidity of 5 ± 5%. The testing was performed on: Test #1: 29-7-1 Test #2: 29-7-14 Test #3: 29-7-14 SUMMARY OF TEST PROCEDURE The tunnel is preheated to 85 C, as measured by the backwall-embedded thermocouple located 79 mm downstream of the burner ports, and allowed to cool to 4 C, as measured by the backwall-embedded thermocouple located 4 mm from the burners. At this time the tunnel lid is raised and the test sample is placed along the ledges of the tunnel so as to form a continuous ceiling 7315 mm long, 35 mm above the floor. The lid is then lowered into place.

CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" Page 3 of 6 For: Polygal Plastics Industries, Ltd. Report No. 9-2-494(C) SUMMARY OF TEST PROCEDURE (continued) Upon ignition of the gas burners, the flame spread distance is observed and recorded every 15 seconds. Flame spread distance versus time is plotted, ignoring any flame front recessions. Calculations are based on comparison with flame spread characteristics of select red oak, determined in calibration trials and arbitrarily established as 1. If the area under the curve (A) is less than or equal to 29.7 m min, FSV = 1.85 A; if greater, FSV = 164/(59.4-A). The Smoke Developed Value is determined by comparing the area under the obscuration curve for the test sample to that of inorganic reinforced cement board and red oak, established as and 1, respectively. TEST RESULTS SAMPLE FSV SDV "POLPC16/2.7CX/CLR16" Test #1 9 122 Rounded Average Flame Spread Rating (FSR): 2 Rounded Average Smoke Developed Classification (SDC): 135 Observations of Burning Characteristics Test #2 43 26 Test #3 3 81 Average: 19 136 - The samples ignited approximately 7.5, 5.5, and 7. minutes after exposure to the test flame. - The flame fronts advanced to a maximum distances of 6., 6., and 4.6 metres at approximately 9.5, 6.5, and 1. minutes into each respective test. - Smoke Developed and temperature were also recorded during the tests (see accompanying charts). Note: This is an electronic copy of the report. Signatures are on file with the original report. Robert A. Carleton, Fire Testing. Ian Smith, Fire Testing. Note: This report consists of 6 pages, including the cover page, that comprises the report "body". It should be considered incomplete if all pages are not present.

CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" Page 4 of 6 For: Polygal Plastics Industries, Ltd. Report No. 9-2-494(C) : "POLPC16/2.7CX/CLR16" Test #1 of 3 6 FLAME SPREAD 5 Red Oak (FSV=1) Flame Spread in Metres 4 3 2 1 % Light Absorption 1 2 3 4 5 6 7 8 9 1 1 9 8 7 6 5 4 3 2 1 Red Oak (SDV=1) SMOKE DEVELOPED 1 2 3 4 5 6 7 8 9 1 7 TEMPERATURE Temperature ( C) 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 FSV SDV 9 122

CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" Page 5 of 6 For: Polygal Plastics Industries, Ltd. Report No. 9-2-494(C) : "POLPC16/2.7CX/CLR16" Test #2 of 3 6 FLAME SPREAD 5 Red Oak (FSV=1) Flame Spread in Metres 4 3 2 1 1 2 3 4 5 6 7 8 9 1 % Light Absorption 1 9 8 7 6 5 4 3 2 1 Red Oak (SDV=1) SMOKE DEVELOPED 1 2 3 4 5 6 7 8 9 1 7 TEMPERATURE 6 Temperature ( C) 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 FSV SDV 43 26

CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" Page 6 of 6 For: Polygal Plastics Industries, Ltd. Report No. 9-2-494(C) : "POLPC16/2.7CX/CLR16" Test #3 of 3 6 FLAME SPREAD 5 Red Oak (FSV=1) Flame Spread in Metres 4 3 2 1 1 2 3 4 5 6 7 8 9 1 % Light Absorption 1 9 8 7 6 5 4 3 2 1 Red Oak (SDV=1) SMOKE DEVELOPED 1 2 3 4 5 6 7 8 9 1 7 TEMPERATURE 6 Temperature ( C) 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 FSV SDV 3 81