CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Similar documents
CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

We Identify and S.T.O.P. Your Noise Problems

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel"

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

SIGMADEK, LTD. FIRE TEST REPORT

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Acoustical Surfaces, Inc.

FUNDERMAX GMBH FIRE TEST REPORT

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

GUARDIAN FIRE TESTING LABORATORIES, INC.

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Report of Surface Burning Characteristics Test on Acoustical Panel

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

BS EN ISO : 2010

BS EN ISO : 2010

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

BS EN ISO : 2010

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Report VNLF Test Report

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

BS 476: Part 6: 1989+A1:2009

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

NF X : Parts 1, 2, 3, 4 & 5

Public Comment No. 2-NFPA [ Section No ]

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Materials Testing by Gregory Havel

IMO Resolution MSC 61(67): Annex 1: Part 2

TFI Report Reaction to fire test

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Classification of Fire Performance of Wall and Ceiling Lining Materials

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

BS EN : 2001 & IEC :2000

The Baked Food Company

BS 476: Part 6: 1989+A1:2009

BCTC CARPET TECHNICAL CENTRE

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

Review Fire Test Report

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

Test Report: ICL/CR15/11/087

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

ISO INTERNATIONAL STANDARD

An experimental study of the impact of tunnel suppression on tunnel ventilation

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Report On Surface Burning Characteristics Determined By. PREPARED FOR: Forbo Linoleum, Inc. Hazelton, Pennsylvania TEST NUMBER T-21906

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

Abrasion Resistance of Fluoropolymer and polyester Coatings

C-01 FIRE DECKS AND BULKHEADS

Test Report: ICL/H18/9039 Rev 1

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Transcription:

UNCONTROLLED ELECTRONIC COPY CAN/ULC-S12 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum A Report To: DiZal inc. 12 rue Bouvier, Suite 4 Québec, QC G2K K9 Phone: 418-52-6954 Attention: E-mail: Louis-André Gaudreau, Ing. louisandre@dizal.ca Submitted by: Warringtonfire North America Report No. 16-2-517(B) 6 Pages Date: September 23, 216

CAN/ULC-S12-1 Testing of "Digitally Printed Aluminum Siding" Coated Aluminum Page 2 of 6 For: DiZal inc. Report No. 16-2-517(B) ACCREDITATION To ISO/IEC 1725 for a defined Scope of Testing by the International Accreditation Service SPECIFICATIONS OF ORDER Determine the Flame Spread Rating and Smoke Developed Classification based upon triplicate testing conducted in accordance with CAN/ULC-S12-1, as per DiZal inc. reference Purchase Order No. 218R1 and Warringtonfire North America Quotation No. 16-2-41842RV2 dated September 7, 216. SAMPLE IDENTIFICATION ( sample identification number 16-2-S517) Coated aluminum 6" (152 mm) profile material, approximately 2 mm in thickness, descrfibed as, "Aluminum, primer, ink jet printed texture and clear", identified as: "Digitally Printed Aluminum Siding" TEST PROCEDURE The method, designated as CAN/ULC-S12-1, "Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies", is designed to determine the relative surface burning characteristics of materials under specific test conditions. Results of less than three identical specimens are expressed in terms of Flame Spread Value (FSV) and Smoke Developed Value (SDV). Results of three or more replicate tests on identical samples produce average values expressed as Flame Spread Rating (FSR) and Smoke Developed Classification (SDC). Although the procedure is applicable to materials, products and assemblies used in building construction for development of comparative surface spread of flame data, the test results may not reflect the relative surface burning characteristics of tested materials under all building fire conditions. SAMPLE PREPARATION Each test specimen consisted of a total of 6 sections of material, each approximately 2 mm in thickness by 171 mm in width by 3658 mm in length. The sections were supported on 6 mm diameter steel rods placed across the width of the tunnel, and spaced at nominal 61 mm intervals. The sections were butted together side-by-side and end-to-end to form the requisite specimen area (3 wide and 2 long). Prior to testing, each specimen was conditioned to constant mass at a temperature of 23 ± 3 C and a relative humidity of 5 ± 5%. In all cases during testing, the coated (coloured) surface was exposed to the test flame. The testing was performed on: Test #1: 216-9-15 Test #2: 216-9-15 Test #3: 216-9-15 SUMMARY OF TEST PROCEDURE The tunnel is preheated to 85 C, as measured by the backwall-embedded thermocouple located 79 mm downstream of the burner ports, and allowed to cool to 4 C, as measured by the backwall-embedded thermocouple located 4 mm from the burners. At this time the tunnel lid is raised and the test sample is placed along the ledges of the tunnel so as to form a continuous ceiling 7315 mm long, 35 mm above the floor. The lid is then lowered into place.

CAN/ULC-S12-1 Testing of "Digitally Printed Aluminum Siding" Coated Aluminum Page 3 of 6 For: DiZal inc. Report No. 16-2-517(B) SUMMARY OF TEST PROCEDURE (continued) Upon ignition of the gas burners, the flame spread distance is observed and recorded every second. Flame spread distance versus time is plotted. Calculations ignore all flame front recessions and the Flame Spread Values (FSV) are determined by calculating the total area under the curve for each test sample. If the total area under the curve (AT) is less than or equal to 29.7 m min, FSV = 1.85 AT; if greater, FSV = 164/(59.4-AT). Smoke Developed Values (SDV) are determined by comparing the area under the obscuration curve for each test sample to that of inorganic reinforced cement board and red oak, established as and 1, respectively. Each Smoke Developed Value is determined by dividing the total area under the obscuration curve by that of red oak and multiplying by 1. TEST RESULTS Flame Spread Smoke Developed SAMPLE Value (FSV) Value (SDV) "Digitally Printed Aluminum Siding" Test #1 2 9 Test #2 2 6 Test #3 5 4 Average: 3 6 Rounded Average Flame Spread Rating (FSR): 5 Rounded Average Smoke Developed Classification (SDC): 5 Observations of Burning Characteristics - The specimens ignited approximately 52 to 6 seconds after exposure to the test flame. Surface blistering and delamination was observed. Partial collapse in the test burner impingement area was also observed. - The flame fronts advanced to maximum distances of.1,.1 and.3 metres at approximately 87, 8, and 75 seconds into each respective test. Note: This is an uncontrolled electronic copy of the report. Signatures are on file with the original. Robert A. Carleton, Technologist. Ian Smith, Technical Manager. Note: This report and service are covered under Canada Inc. Standard Terms and Conditions of Contract which may be found on the website (www.exova.com), or by calling 1-866-263-9268.

CAN/ULC-S12-1 Testing of "Digitally Printed Aluminum Siding" Coated Aluminum Page 4 of 6 For: DiZal inc. Report No. 16-2-517(B) : "Digitally Printed Aluminum Siding" Test #1 of 3 6 FLAME SPREAD Flame Spread in Metres 5 4 3 2 1 Red Oak (FSV=1) % Light Absorption 1 9 8 Red Oak (SDV=1) SMOKE DEVELOPED 7 6 5 4 3 2 1 3 TEMPERATURE Temperature ( C) 2 1 FSV SDV Max. Temp. ( C) 2 9 282

CAN/ULC-S12-1 Testing of "Digitally Printed Aluminum Siding" Coated Aluminum Page 5 of 6 For: DiZal inc. Report No. 16-2-517(B) : "Digitally Printed Aluminum Siding" Test #2 of 3 6 FLAME SPREAD Flame Spread in Metres 5 4 3 2 1 Red Oak (FSV=1) % Light Absorption SMOKE DEVELOPED 1 9 Red Oak (SDV=1) 8 7 6 5 4 3 2 1 3 TEMPERATURE Temperature ( C) 2 1 FSV SDV Max. Temp. ( C) 2 6 285

CAN/ULC-S12-1 Testing of "Digitally Printed Aluminum Siding" Coated Aluminum Page 6 of 6 For: DiZal inc. Report No. 16-2-517(B) : "Digitally Printed Aluminum Siding" Test #3 of 3 6 FLAME SPREAD Flame Spread in Metres 5 4 3 2 1 Red Oak (FSV=1) % Light Absorption SMOKE DEVELOPED 1 9 Red Oak (SDV=1) 8 7 6 5 4 3 2 1 3 TEMPERATURE Temperature ( C) 2 1 FSV SDV Max. Temp. ( C) 5 4 298