Wind Analysis of the Bosphorus Suspension Bridge: Numerical and Experimental Investigation

Similar documents
Long-Span Orthotropic Steel Deck Bridges of Turkey

Instrumentación de Puentes

Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener

Dynamic Performance of the Guarda Footbridge

VALIDATION OF FINITE ELEMENT MODELS OF INJURY RISK IN VEHICLE-ROADSIDE BARRIER CRASHES

The Effect of Pedestrian Traffic on the Dynamic Behavior of Footbridges M. Studničková

Research Article Vibration Characteristics of Composite Footbridges under Various Human Running Loads

Application of Wireless Monitoring System for the Ambient Vibration Study of the WuYuan Steel Arch Bridge

COST REDUCTION OF SECTION CHANNEL BY VALUE ENGINEERING

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Construction Research Centre, Universiti Teknologi Malaysia (UTM-CRC), UTM Johor Bahru, Johor, Malaysia

APPLICATION FIELD INCLUDE:

GEOTEXTILE DEFORMATION ANALYSIS OF GEOSYNTHETIC CLAY LINERS WITH FEM

RESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Experimental Dynamic Behaviour and Pedestrian Excited Vibrations Mitigation at Ceramique Footbridge (Maastricht, NL)

EFFECT OF BOLT CONNECTION OF SQUARE-SHAPED GEOCELL MODEL ON PULLOUT TEST RESULTS

Diminishing Role of Urban Planner, Rising Power of Market

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

Long Span Bridge in Norway

Effect of Foundation Embedment of PWR Structures in SSI Analysis considering Spatial Incoherence of Ground Motions

URBAN TRANSPORT PLANNING and DECISION-MAKING for LARGE URBAN PROJECTS in TURKEY. EK Istanbul Technical University Istanbul, Turkey.

EVALUATING VIBRATIONS ON A SMALL-SCALE MODEL OF A TIMBER FOOTBRIDGE ABSTRACT

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

BRIDGES CONNECT GULIZAR OZYURT TCCE. 49 th ECCE General Meeting May 2009 Ljubljana, Slovenia

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Case Study Canton Tower at Guangzhou. Guangzhou, China 2010

PULLOUT CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN CLAYEY SOILS

Slope stability assessment

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 10 October 2017

1441. Quantification of the flow noise in household refrigerators

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Soil-Structure Interaction of a Piled Raft Foundation in Clay a 3D Numerical Study

Sprinklers Modeling for Tunnel Road Fire Fighting

Bucks Bar Road Bridge Project Public Informational Meeting Wednesday, January 6, 2010

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

DYNAMIC ANALYSIS OF FOOTBRIDGES A CASE STUDY CALATRAVA: PASSAGE CONNECTING THE ORIENT STATION AND THE

FIG Working Week

CROWD-SOURCED REMOTE ASSESSMENTS OF REGIONAL-SCALE POST-DISASTER DAMAGE

Effect of Placement of Footing on Stability of Slope

Dynamic behaviour of the steel footbridges with spatial pipe truss girders

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Transport research opportunities and needs: What can fibre optics do for us? Stephen James Engineering Photonics

Long span bridges in Norway, including future crossing of the Oslo Fjord

Form-finding study of Taizhou Bridge A 3-pylon suspension bridge

Company Introduction. Logtech! to aim at best of vibration & noise field

A FRAMEWORK FOR EVALUATION AND ASSESSMENT OF PROTO-MODERN BRIDGES

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

DYNAMIC NUMERICAL ANALYSIS OF STEEL FOOTBRIDGE

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu.

Stability of Inclined Strip Anchors in Purely Cohesive Soil

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Piles subject to excavation-induced soil movement in clay

Full Scale Model Test of Soil Reinforcement on Soft Soil Deposition with Inclined Timber Pile

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

EMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA

Tokyo-wan Aqualine - Experience of Traffic and Safety

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Stability analysis of slopes with surcharge by LEM and FEM

Heat Transfer in Evacuated Tubular Solar Collectors

TRANSPORTATION. Down to Earth. Up to the Challenge. Engineering, Geoscience and Environmental Services ALEX FRASER BRIDGE, BC, CANADA

Vibration Services. Centre Spatial de Liège. Advanced Technologies Space Instruments Test Services. Analysis. Test. Model Adaptation.

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

A WIRTGEN GROUP COMPANY. Intelligent compaction OSCILLATION

Numerical simulation of single- and doublefaced W-beam guardrails under vehicular impacts on six-lane divided freeways

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

Evaluation of a Support System for Large Area Tourist Evacuation Guidance: Kyoto Simulation Results

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

Thermomechanical Fatigue (TMF) Test System

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

The Earthquake Monitoring System for Dams of a reservoir in China SUMMARY

GINPROSA INGENIERÍA Company Presentation

Michael Davidson, Ph.D., P.E.

AXIAL & JET FANS FOR TUNNEL VENTILATION

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

Health Monitoring System Using FBG-Based Sensors for a 12-Story Building with Column Dampers.

COMPACTION TECHNOLOGY

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN

PYUNGHWA ENGINEERING CONSULTANTS includes the philisophy in the city

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

Design of Takimi Footbridge locating the world heritage Shiraito Falls

The Ageing Process for Extruded Aluminum Profiles

S. Motoyui 1 and Y. Sato 2

SUBGRADE IMPROVEMENT OF CLAYEY SOIL WITH THE USE OF GEOTEXTILES

Instructional Objectives WHAT CAN WE MEASURE? Applications. GE 5471 ROCK ENGINEERING CH 12 Monitoring WHY DO WE NEED MONITORING?

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Non-destructive inspection method for concrete elements in tunnel linings using laser remote sensing

Compression of Fins pipe and simple Heat pipe Using CFD

Transcription:

Wind Analysis of the Bosphorus Suspension Bridge: Numerical and Experimental Investigation Selcuk Bas 1, 2, Nurdan M. Apaydin 3, Alper Ilki 4 and F. Necati Catbas 5 1 Department of Civil Engineering, Bartin University, Bartin, Turkey 2 Graduate School of Science, Engineering and Technology, Istanbul Technical University, Istanbul Turkey 2 Department of Structures, General Directorate of Turkish State Highways, Ankara, Turkey 3 Department of Civil Engineering, Istanbul Technical University, Istanbul Turkey 4 Civil, Environmental and Construction Engineering, University of Central Florida, Florida, USA ABSTRACT: Long-span suspension bridges are subjected to various loading events in their lifecycle. Along with operational loads, they have experiences on extreme loads, such as earthquake, wind, marathon etc. Of all these extreme events, wind is the most critical one, which in turn design considerations of the structural components of long-span bridges are adopted according to wind load. Based on these considerations, wind-induced behavior of the Bosphorus Bridge is presented in this study. For this aim, the extreme wind events that happened in April 18 2012 is considered and the data obtained from the Structural Health Monitoring system-shms of the bridge during the event are utilized for experimental analysis. Conducting certain data processing methods to make the SHM data more identifiable on the basis on modal characteristics of the bridge, the response of the bridge to the strong wind event are determined. For numerical investigation on wind behavior of the bridge, 3-D full-scale shell finite element model (FE) of the bridge is established and the sophisticated FE model is verified with the SHM data from the extreme wind event. The results from the data analysis exhibited that the bridge relatively excited in lateral direction; however, no damage is predicted under the strong wind. For the certain critical issue of fatigue prediction not only in the local system but also in global system, stress controlling on the component of the bridge, stress-strain observation, local buckling investigation and optimum sensor location prediction, numerical dynamic wind analysis of the bridge should be performed simulating the recorded strong wind to time-history dynamic wind load. 1 INTRODUCTION Due to the increasing in the population and the critical location of Istanbul, the need for transportation infrastructures such as long-span crossing bridges over the Bosphorus Straits and railway/ motorway tube-tunnel under the Bosphorus River have relatively increased. As depicted in Figure 1, three long-span bridges are currently in service in Istanbul, one of which is newlycompleted hybrid bridge, the Yavuz Sutlan Selim Bridge. Moreover, the other bridge, the Osman Gazi Bridge as shown in Figure 1d, is also located on the Izmit Bay relatively close to Istanbul. The Bosphorus Bridge is one of the life-line infrastructures of the transportation networks of Istanbul. As indicated in Figure 1a, the Bosphorus Bridge is located on the Bosphorus River that

are naturally surrounded with two continents of Asia and Europe. Until the construction of the 2 nd crossing bridge named Fatih Sultan Mehmet Bridge (Figure 1b), the bridge carried entirely all Istanbul s traffic loads between two continents. After the passage of the heavy truck traffic are limited on the bridge and are diverted to the 2 nd Bridge, the bridge is only permitted to passage of the car traffic. With the newly-completed 3 rd Bosphorus Bridge, Yavuz Sultan Selim Bridge (Figure 1c), three long-span bridges serve as vital links between Europe and Asia continents. Figure 1. Long-span cable-supported bridges in Turkey: (a) the 1 st Bosphorus Bridge (b) Fatih Sultan Mehmet Bridge (c) Yavuz Sultan Selim Bridge (d) Osman Gazi Bridge The first attempts to experimentally investigate ambient and traffic-induced response of the Bosphorus Bridge were made by Tezcan et al. (1975) and Petrovski et al. (1974) for three days before and after the bridge was opened to traffic. Using temporal SHMs, limited number of studies on vibration characteristics of the bridge under ambient and traffic effects were conducted by Brownjohn et al. (1989) and Erdik et al. (1988). They compared the results from experimental data analysis with those from FE model of the bridge. Based on the calibration of FE model with experimental results, they indicated that the developed FE model could be considered for further investigation of the bridge. Using a sensory system with 28 channels, Beyen et al. (1994) also carried out ambient vibration study-avs to determine the dynamic characteristics of the bridge and to compare the obtained results with the previous results in literature. New studies on the monitoring and advanced analysis of the Bosphorus Bridge were performed by Bas et al. (2016a, 2016b, 2015a and 2015b), Apaydin (2010) and Apaydin et al. (2015), Erdik et al. (2007) and Kosar (2002).

This study aims at experimentally identify the response of the Bosphorus Bridge to the extreme wind events and at developing 3-D full-scale shell FE model of the bridge by verifying the bridge s modal parameters with those obtained from the SHM data recorded during this event. For future performance and behavior of the bridge under strong wind events, numerical dynamic wind analysis is concluded to be carried out. 2 GENERAL PROPERTIES OF THE BOSPHORUS BRIDGE The Bosphorus Bridge also called the 1 st Bridge is a modern gravity-anchored steel suspension bridge due to aerodynamic stiffening deck, box towers and portal beams. The suspender elements of the hangers were designed with an inclined form instead of a vertical form. Within the scope of recently conducted elaborate retrofit projects, the hanger cables are replaced to vertical form. 0.60 m 0.58 m 0.058 m Figure 2. General specifications of the bridge KGM (1973) As depicted in Figure 2, the width and height of the deck is 33.40 m and 3.00 m, respectively. The tower with the height of 165 m from the sea level has a tapered section decreasing from bottom section to top-saddle section. The approach spans of the bridge are supported at the base instead of hanger suspenders. Due the fact that the bridge is symmetric according to mid-span, diameter of the main and back-stay cables are approximately same. The hanger elements have a diameter that is 1/10 times of the main and back-stay cables. 3 STRUCTURAL HEALTH MONITORING-SHM SYSTEM OF BRIDGE The Bosphorus Bridge has experienced various excitation events; however, has still continued its function without any damage or adverse effect on the structural components of the bridge. Heavy traffic condition of Istanbul reaching daily 3.5 billion vehicles in traffic and the location of the bridge over the Bosphorus River lead to the need for monitoring the response of the bridge to extreme loading events, such as earthquake, marathon and strong wind.

Table 1. Sensor types and corresponding quantity of SHM system of the bridge Type Quantity Accelerometers 19 Tiltmeters 15 Force Transducer 12 Force Transducer 12 Strain Gauges 70 Laser Displacements 8 GPS 5 Thermocouples 33 Weather Station 6 Total 168 After the critical wind events in 2004, a permanent SHM system with the ability of tracking the behavior of the bridge in real-time was decided to be installed on the bridge. The installed SHMs has 168 sensors which are accelerometer, tiltmeters, force transducer (LVDT), strain gage, whether station, laser displacement, thermocouple and GPS. Sensor type and corresponding quantity are given in Table 1. 4 WIND-INDUCED BEHAVIOR OF THE BRIDGE Strong winds are not very frequent in Istanbul due to its location. However, during the daytime on April 18 2012, a strong storm occurred in Istanbul. It was the first time, the bridge experienced such high wind. According to measurement of Turkish Meteorology Service, the maximum windspeed reached to 122 km/h. Although ultimate design wind speed of the bridge is 162 km/h, the bridge was closed to the traffic for a period of time as a precautionary measure. The change of wind speed with time is shown in Figure 3. This variation is also obtained by weather stations installed on the bridge. As seen from Figure 3a, the average wind speed before the storm was around 20 km/h. However, it suddenly increased to 100-120 km/h in 10 minutes. This variation is also verified with meteorology data as shown in Figure 3b. In order to determine the effect of the strong wind on dynamic characteristics and operational performance of the bridge, all SHM data are divided into three ranges as shown in Figure 4: Before, During and After. The data analysis showed that meaningful results are not obtained for Before range since the data is relatively distorted with traffic noise. Therefore, After range is considered for the comparison with During range. For more refined results from FFT (Fast Fourier Transform), data averaging technique including windowing and overlapping is also implemented. Window length is determined considering the minimum frequency range of the modal values obtained from the previous experimental study in literature. The obtained SHM data from the accelerometers mounted at the specific points of the bridge are utilized for system identification of the bridge. The locations of the accelerometers are indicated with the considered directions in Figure 5. In this figure, the FFT analyses of the all accelerometers are also given to determine modal characteristics of the bridge. The outcomes from the frequency-domain analysis are summarized in Table 2.

(a) (b) Figure 3. Variation of the extreme wind: (a) SHM data (b) Meteorology data Figure 4. Seperated wind data into three ranges Table 2. Wind-induced vibration properties of the bridge Mode Number Mode Shape Frequency/ / Transvers Direction During After Change (%) Mode-1 1 st L sym 14.706 0.068 12.766 0.078 15.196-13.191 Mode-2 1 st V asym 8.065 0.124 8.065 0.124 0.000 0.000 Mode-3 1 st V sym 6.096 0.164 6.250 0.160-2.469 2.531 Mode-4 1 st L asym 4.854 0.206 4.967 0.201-2.265 2.318 Mode-5 2 nd V sym 4.561 0.219 4.525 0.221 0.798-0.792 Lsym: Lateral symmetric; Lasym: Lateral asymmetric;vsym:vertical symmetric; Vasym:Vertical asymmetric

T L V T V T V T T L L: Longitudinal T: Transverse V: Vertical Figure 5. Structural identifcation of the Bosphorus Bridge under the wind event 5 NUMERICAL FE MODEL OF THE BRIDGE All structural components of the bridge were made of steel thin plate. Internal diaphragms were also used to provide additional stiffness for these components. Based on its project drawings, the Figure 6. 3-D full-scale shell FE model of the bridge bridge was modeled using shell element. Besides, link element was considered for deck-tower and side span-tower connections. Considering cable sag effect, cable element features were assigned to the main cable, backstay cable and hangers. The cross girder I beams with tapered

section and the circular box columns of the approach viaducts were modeled as frame element. The established FE model is shown in Figure 6. In this model, 4121 points, 263 frame elements, 387 cable elements and 3996 shell elements were used. For all efforts, SAP2000 (2016) software was utilized. As expected, the first effective mode shape frequency is in transvers direction. In Figure 7, the first 5 modes are shown. These results are then compared with those from After range data. As given in Table 3, closure agreement between the established 3-D full-scale shell FE model and those experimental data is obtained. Mode 2 f=0.102 Hz Mode 3 f=0.154 Hz Mode 1 f=0.076 Hz Mode 4 f=0.199hz Mode 5 f=0.216 Hz Figure 7. Modal analysis of the bridge Table 3. Comparison of numerical and experimental dynamic characteristics of the bridge Mode Number Mode Shape Frequency/ / 3-D Shell FE Model (S-FEM) S-FEM After Change (%) Mode-1 1 st L sym 13.090 0.076 12.766 0.078 2.538-2.979 Mode-2 1 st V asym 7.220 0.139 8.065 0.124-10.472 12.097 Mode-3 1 st V sym 6.481 0.154 6.250 0.160 3.696-3.750 Mode-4 1 st L asym 5.020 0.199 4.967 0.201 1.069-1.159 Mode-5 2 nd V sym 4.620 0.216 4.525 0.221 2.102-2.262 6 CONCLUSION The current study presents the experimental behavior of the Bosphorus Bridge under the extreme wind event occurred in April 18 2012 and advanced 3-D full-scale shell FE modelling

considerations of the bridge. The FE model is updated with the After range data corresponding to natural vibration and relatively good agreement is obtained between the outcomes from FE model and those from the After range. For the During range simulation of the updated sophisticated FE mode, dynamic wind analysis should be performed considering the experimentally varying wind speed as shown in Figure 3 recorded during the extreme wind event. Accordingly, certain performance predictions pertinent to fatigue prediction not only in the local system but also in global system, stress controlling on the component of the bridge, stress-strain observation, local buckling investigation and optimum sensor configuration are made through the dynamic wind analysis. As to the experimental consequences of the bridge, the first modal frequency (lateral symmetric) of the bridge decreased in the range of 13% under the extreme wind loading. Only change in the deck modes of the bridge is obtained. This is pertinent to high rigidity of tower box section in transverse direction. After the extreme wind excitation, the natural frequencies of the bridge are also obtained, meaning that no damage is estimated under the strong wind. High modal periods during the wind indicated that damping of the bridge increased. 7 REFERENCES Apaydin, N.M, 2010, Earthquake performance assessment and retrofit investigations of two suspension bridges in Istanbul. Soil Dynamics and Earthquake Engineering, 30(8): 702-710. Bas, S., N.M. Apayadin and Z. Celep, 2016(a), Earthquake performance of the two approach viaducts of the Bosphorus suspension bridge. Earthquake and Structures, 11(3): 387-406. Bas, S., N.M. Apaydin, A. Ilki and N. Catbas, 2016, Structural health monitoring system-shms of the long span bridges in Turkey. The 8 th International Conference on Bridge Maintenance, Safety and Management (IABMAS 2016), Brazil. Bas, S., N.M. Apaydin and N. Catbas, 2015(a), Long-span bridges: behavior under operational and extreme wind loads. The Third International Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Structures (SMAR2015), Antalya, Turkey. Bas, S, Apayadin, M.N. and Celep, Z. 2015(b). Free vibration analysis and seismic performance assessment of two approach viaducts of Bosphorus Suspension. Bridge. Developments in International Bridge Engineering. Springer International Publishing, p. 65-75 Beyen, K, E. Uckan and M. Erdik, 1994, Ambient vibration investigation of the Bogazici Suspension Bridge. The 2nd International Conference on Earthquake Resistant Construction and Design, Berlin, Germany. Brownjohn, JMW., A.A. Dumanoglu, R.T. Severn and A. Blakeborough, 1989, Ambient vibration survey of the Bosporus Suspension Bridge. Earthquake Engineering and Structural Dynamics, 1989; 18(2); 263-283. Erdik M. and Apaydin N.M. (2007). Earthquake Response of Suspension Bridges. In: Esin I, Dipak S, editors, Vibration Problems ICOVP 2005. Dordrecht Netherlands: Springer, 2007; p. 181-194. Erdik, M. and E. Uckan, 1988, Ambient vibration survey of the Bogazici Suspension Bridge. Department of Earthquake Engineering, Kandilli Observatory and Earthquake Research Institute, Bogazici University, Istanbul, Turkey. KGM, 1973, Record Book: the Bosphorus Bridge. General Directorate of Turkish State Highways; Ankara, Turkey. Kosar, U., 2002, System Identification of the Bogazici Suspension Bridge, Master Thesis Department of Earthquake Engineering, Bogazici Univsity, Istanbul, Turkey. Petrovski, J.P., T. Paskalov, A. Stojkovichet and D. Jurokovski, 1974, Vibration studies of Istanbul Bogazici Suspension Bridge. Institute of Earthquake Engineering and Engineering Seismology (IZIIS). Skopje, Yugoslavia. SAP2000, 2016, Integrated Software for Structural Analysis and Design. Computers and Structures Inc., Walnut Creek, California. Tezcan S., M. Ipek, J. Petrovski and T. Paskalov, 1975, Forced vibration survey of Istanbul Bogazici Bridge. Proceedings of 5th ECEE Conference. Istanbul, Turkey.