E C O L O G I C A L C O O L E R S INTELLIGENT

Similar documents
IMPORTANT. World-wide Patents. VIGIA is a trademark of Col-Ven S.A.

Parts Catalogue. /

E C O L O G I C A L C O O L E R S INTELLIGENT

E C O L O G I C A L C O O L E R S INTELLIGENT PLUS PARTS CATALOGUE

E C O L O G I C A L C O O L E R S AGRO

E C O L O G I C A L C O O L E R S INTELLIGENT PLUS

CD6102 / CD6102 OC / CD6102-2

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Thermometer with Wired Sensor

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

User s Manual and Operating Instructions

Outdoor Refrigerator USER S MANUAL

LiqTec, V GRUNDFOS INSTRUCTIONS

D E S I G N G U I D E REVISED 9 / 2018

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

BlueHeat Coolant Heater Car and Light Truck Auxiliary Heater

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

DUST FREE CARBON Whole House Air Purifier

Remote Vehicle Control System

DIGITAL STEEL FIRE & SECURITY

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

D E S I G N G U I D E REVISED 10 / 2017

DIGITAL STEEL FIRE & SECURITY

MGC Dock User s Manual

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

INSTRUCTION MANUAL HS-229G

Thermostat Remote Control & Receiver

AG Series Electric Heaters

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

AirInstinct Air Purifier

GETZ MANUFACTURING PART # CYLINDER DRYER

Zeus Extreme Owner's Manual

Gem Multicooker. User Manual

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

Outdoor/Commercial Refrigerator USER S MANUAL

Owner s Manual. PIR-1 IR Learner

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Ui REFRIGERATOR SPEC SHEET

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

This instruction manual explains the use of three models listed on the left.

Digital Refrigerator/Freezer Thermometer model 00986

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

User s Manual and Operating Instructions

IMPORTANT SAFETY INFORMATION:

Compact Equipment Warranty Policy

Thermometer model 02059

DEHUMIDIFIER. User Manual 50BT, 70BT

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

Instruction Leaflet. Read instructions before operating. Retain for future reference.

VX SERIES Wireless Thermostat with Occupancy Sensor

MaxLite LED High Bay Fixtures

Horizontal Bottle Cooler Installation and Operation Manual

Owner s. Coolerr. comply. To view

IMPORTANT SAFETY INFORMATION:

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

636 and 646 Keypads. User s Manual

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Thermometer with Probe model 00891A

Service & Parts Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

CA 120 Owners Manual of 10

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

IMPORTANT SAFETY INFORMATION:

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

MGC Dock User s Manual

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

READ AND SAVE THESE INSTRUCTIONS. Vacuum Food Storage System Reference Guide. Space Saving Design.

User Manual for Car Refrigerator/Freezer

26 LB CAPACITY ICE MAKER

TrueClean ToteCleaner

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Remote Relay Module (RRM)

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

BLT-999W-2 Item # 60757

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Savore Electric Pepper Grinder

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

INSTALLER S & OWNER S MANUAL

Refrigerator Freezer Installation and Operation Manual

Humidity Monitor model 01080

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Transcription:

E C O L O G I C A L C O O L E R S INTELLIGENT 12 User s Manual wwwviesaca / 1-888 438-8444

IMPORTANT Installation requires an experienced mechanic with specific knowledge in the installation of the VIESA Ecological Cooler Installation, disassembly, repairs and maintenance must be performed by an Authorized Installer Authorized Installer must use proper protective equipment when installing the system Improper installation or use of unauthorized parts can cause malfunctions, loss of battery life or other consequences which may result in serious injury Manufacturer or Distributor will not be responsible for injuries or damages resulting from misuse of equipment, use contrary to operating instructions or installation by any person other than an Authorized Installer Information contained in this manual is subject to change Manufacturer reserves the right, without notice, to make changes in equipment design or components as progress in engineering, manufacturing or technology may warrant World-wide Patents VIGIA is a trademark of Col-Ven SA

Function VIESA Intelligent 12 is a roof mounted cab cooler that delivers cool air to the truck's cabin using evaporative cooling and without running the vehicle's engine Operation Cooling is generated by vaporized cool water delivered by a self-contained electrical motor During operation it only consumes water and it makes no use of internal combustion engines, nor does it use chemical coolants or emit gases into the atmosphere The unit is equipped with a water pump located in an auxiliary tank which takes water to the evaporator A biturbo blower pushes the exterior air to the interior of the vehicle forcing the air through the evaporator and therefore cooling the warm air The exceeding water backs to the water tank Application Applied to any unit with an operating voltage of 12 V Viesa Intelligent 12 cannot be installed to cabins with roof-ceiling thickness of less than 6 cm

BOARD INDICATIONS Important: before switching on the equipment: With parked vehicle: Open one of the windows 2 to 3 cms With the vehicle in motion: Open one of the windows 2 to 3 cms and close all other air entrances to the cabin so that hot air does not enter from exterior BOARD IT ALLOWS TO POWER ON AND OFF THE EQUIPMENT (TURBO FAN, CONTROL OF THE WATER PUMP AND AIR INLET SYSTEM) IT ALLOWS TO SEE THE FUNCTIONS AND PARAMETERS OF THE EQUIPMENT IT ALLOWS TO ACTI- VATE AND DEACTI- VATE THE OPERATION OF THE WATER CYCLE REMOTE CONTROL RECEIVER AUTO Power KEEP PRESSED FOR 2 SECONDS TO SHUT DOWN AND RESTART IT ALLOWS TO SEE AND ENTER THE FUNCTIONS: TIME SETTING ALARM CLOCK AUTO POWER ON AUTO POWER OFF AUTOMATIC MODE IT ALLOWS TO INCREASE AND/OR LOWER THE SPEED OF THE TURBO FAN AND THE PARAMETERS OF THE CLOCK, ALARM CLOCK, AUTO POWER ON, AUTO POWER OFF AND AUTOMATIC MODE Dry IT ALLOWS TO ACTI- VATE THE AUTOMATIC DRYING SYSTEM: TURBO FAN TO TOP SPEED UNTILL THE EVAPORATOR GETS DRY Note: time is expressed in 24H mode REMOTE CONTROL Performs all the functions described above Dry : It activates the drying system; turbo fan to top speed until the evaporator gets dry - Keep the batteries of the remote control away from children Wrong use may cause fire or burns Do not recharge or heat batteries Dispose dead batteries according to local laws Replace batteries with the same type (AAA) - Batteries may explode if not correctly inserted Immediately dispose of dead batteries Do not throw them into fire

DISPLAY INDICATIONS DRYING SYSTEM ACTIVATED AUTOMATIC MODE ACTIVATED AUTO POWER ON OR AUTO POWER OFF ACTIVATED TURBO FAN ON TIME/ TURBO FAN SPEED LEVELS WATER PUMP OR TURBO FAN DISCONNECTION BATTERY LEVEL WATER CYCLE ACTIVATED ALARM CLOCK ACTIVATED NOT ENOUGH WATER IN THE TANK SHORT CIRCUIT IN THE WATER PUMP OR IN THE TURBO FAN / CHANGE THE EVAPORATOR PERMANENT INFORMATION - Clock - Battery level: If the voltage decreases to 11,8 V (factory setting), a blinking display will appear and the equipment will start slowing down automatically, decreasing progressively the turbo fan speed The command and control module registers the working hours, and after working for 546 hours, turns on permanently indicting the evaporator needs to be replaced Important: Every time the evaporator is replaced the working time must be set to (zero) TURBO FAN By pressing the turbo fan and the pump control system will be activated By pressing again the turbo fan and the pump control system will be disconnected

This equipment has 8 speed levels, which can be changed by pressing or Note: keeping pressed one of these the buttons, the speed will vary in sublevels (a total of 24), which will not be displayed and will not emit any sound when passing from one sublevel to another If the turbo fan is disconnected is displayed and the system will make a sound Will disappear after the problem is solved and the equipment is turned on by pressing In case the turbo fan consumes more than usual, and will be displayed and the system will beep 3 times It will disappear after the problem is solved and the equipment is turned on by pressing Note: If the turbo fan consumes more than 11 Amps it is considered as over-consumption WATER PUMP When pressing the water pump will turn off When pressing again, the water pump will turn on The key will activate and deactivate the pump control independently of whether the equipment is activated with or not If there is not enough water in the tank, the pump will not work and the system will make a sound will be displayed Important: - If the equipment is turned off, will turn off when water is poured into the tank - If the equipment is turned on, will turn off when water is poured into the tank and the key is pressed

If the pump is disconnected, will turn on and the system will make a sound Will disappear after the problem is solved and the pump control is turned on by pressing Note: the turbo fan will continue working Important: The indication of pump disconnected will only show when the pump system is activated In case the pump consumes more than usual, system will beep 3 times and will be displayed and the Will disappear after the problem is solved and the pump control is turned on by pressing note: If the pump consumes more than 7Amps it is consider over-consumption Functions With the key the user has access to different functions: Time setting Alarm clock Auto power on Auto power off Automatic mode Set Time It allows the operator to set the equipment clock Press until is displayed and then press The hour blinks, press or to set the hour Pressing select the minutes Use or to set the minutes note: To confirm the hour, wait 5 seconds or press

Alarm clock Press until is displayed and then press The hour blinks, press or to set the hour Press to select the minutes Use or to set the minutes Using the alarm clock is selected Then, blinks, press to activate or press to deactivate Note: To confirm alarm clock, wait 5 seconds or press To turn off the alarm clock, press any key from the control panel or from the remote control, except for Power Auto Power On It allows the operator to turn on the equipment automatically at a preprogrammed time Use until and appear and then press Program the clock (see "Set Time") Use to select Then blinks, press to activate it or press to deactivate it Note: To confirm auto power on, wait 5 seconds or press Auto Power Off It allows the operator to power off the equipment automatically at a pre-programmed time Use until is displayed and then press Program the clock (see "Set Time")

Using, is selected Then blinks, press to activate it or press to deactivate it note: To confirm auto power off, wait 5 seconds or press Note: The power off system can be set even when the equipment is off Automatic Mode It regulates automatically the speed of the turbo fan according to the exterior temperature Use until appears and then press Then blinks, press to activate it or press to deactivate it Note: To confirm automatic mode, wait 5 seconds or press Explanation: The turbo fan and the water pump will not power off even if the exterior temperature is very low; in this case the blower will continue working at the minimum speed Take into account the following chart : EXTERNAL TEMPERATURE SPEED 29 C or higher 84 F or higher 8 28 C 82 F 7 27 C 81 F 6 26 C 79 F 5 25 C 77 F 4 24 C 75 F 3 23 C 73 F 2 22 C or lower 72 F or lower 1 DRYING SYSTEM This unit is equipped with a drying feature which operates the fan to dry out the evaporator Important: If the equipment will remain off for more than 48 hs, activate the drying system to avoid bad smells when restarting it

When pressing Dry the equipment will dry the evaporator, starting a countdown and then it will finish automatically To deactivate the drying system, press Dry Note: the drying time of the evaporator is factory set to 35 minutes This is the time we deemed required for normal humidity conditions This time can be changed POWER OFF When pressing for 2 seconds the power off button Power the equipment will completely turn-off (Including the display) To restart it press Power MAXIMUM TIME IN SERVICE Every time the equipment is turned on with, it will work for a maximum period of time previously programmed and then it will turn off automatically By default, the period is set to 9 hours Set period can be changed during initial configuration at installation

MAINTENANCE When is displayed, call your local technical service The equipment will delay in cooling until the evaporator is totally wet Do not use fuses higher than 15 Amp The equipment will deactivate automatically due to low tension so as to prevent damages to the battery Use only clean water Foresee replenishment of water taking into account that the equipment consumes between 2 and 5 litres per hour depending on the ambient temperature During short stops leave the equipment on so as to keep the cabin fresh System must be turned off when exhaust fumes or toxic particles could enter the cab through the system VIESA SCENTED FLUID (EVERY 200 HOURS OF USE) When performing maintenance of the equipment or if the evaporator unit's cover or the upholstery cover are removed, the system MUST NOT BE SWITCHED ON and you must not switch it on with any of these elements removed Keep the tank clean Every 200 hours of use - Drain all the water from the tank by removing the drain plug - Rinse with clean water thoroughly - Pour one bottle of Viesa Scented Cleansing Fluid - Fill-up the tank with clean water Each 6 months change the package of granulated Calfa Bas crystals Do not use chemical products to clean the control panel GRANULATED CALFA BAS EACH 6 MONTHS Every 2 months or according to working conditions: - Submerge the evaporator in water with bleach (1) - Clean the grids of the air entrances (2) - Clean the filter of the collector tray (3) Once a year replace the evaporator (1)

LIMITED WARRANTY This limited warranty is provided to the original buyer only and covers the VIESA ECOLOGICAL CAB COOLER (the "Product") manufactured by Col-Ven SA (the "Manufacturer") and distributed by RCR Systems Limited (the "Distributor") The warranty period is two years from date of original purchase by the buyer During this period, if the product is found to be defective in mechanical or electrical materials or workmanship during normal use, it will be repaired or replaced at no charge to the buyer The buyer will be required to show date and proof of purchase and to return the Product pre-paid to an Authorized Dealer THIS LIMITED WARRANTY DOES NOT COVER, AND MANUFACTURER OR DISTRIBUTOR WILL NOT BE RESPONSIBLE FOR, THE FOLLOWING: -Normal wear of parts; -Failures or defects due to negligent use, misuse, neglect, abuse, use on improper voltage or current, use contrary to operating instructions, accidents, alterations, disassembly, installation, repair or alteration by any person other than an Authorized Dealer, fire, floods or acts of God -Products or accessory equipment not manufactured by the Manufacturer -Performance of Product when used in combination with other products or equipment not manufactured by the Manufacturer -Payments for labour or service to unauthorized representatives or service agents Manufacturer or Distributor will not be responsible for loss of time, inconvenience, loss of use of the Product, injury to buyer or other persons or damage to vehicle or property caused by the Product or by its failure to work or for any other incidental, punitive or consequential damages The Manufacturer reserves the right to make the final decision on any warranty claim that may be questionable This warranty is not transferable EXCEPT AS PROVIDED HEREIN, THIS WARRANTY EXPRESSLY EXCLUDES: (i) all warranties and conditions, whether express, implied or statutory, including but not limited to warranties and conditions of merchantability for a particular purpose; and (ii) any agreements, representations, affirmations, warranties or conditions, whether oral or written, made by any agent, employee or representative of seller This warranty sets forth the entire responsibility of Manufacturer and Distributor with respect to the Product The buyer's exclusive remedy is repair or replacement as stated herein In no event shall Manufacturer or Distributor's liability exceed the cost of correcting defects as provided herein and any such liabilities will terminate upon expiration of the two year warranty period

USER S MANUAL VIESA INTELLIGENT 12 REVISION 003 1-2012 POBox 1352 1500 Avenue Road Toronto, Ontario M5M 0A1 CANADA Ruta 11 Km814 - Guadalupe Norte Prov de Santa Fe (S3574XAB) ARGENTINA ORDER ON-LINE wwwviesaca / 1-888 438-8444