High Temperature Water Heat Pipes for Kilopower System

Similar documents
Sodium Heat Pipes for Spacecraft Fission Power Generation

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

Self-Venting Arterial Heat Pipes for Spacecraft Applications

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Diode Heat Pipes for Long-Lived Venus Landers

Variable Conductance Heat Pipe Radiator for Lunar Fission Power Systems

Advanced Passive Thermal Experiment for Hybrid Variable Conductance Heat Pipes and High Conductivity Plates on the International Space Station

Variable Thermal Conductance Link for Lunar Landers and Rovers

Loop Heat Pipe Wick Fabrication via Additive Manufacturing

Loop Heat Pipe Radiator Trade Study for the K Temperature Range

15. Heat Pipes in Electronics (1)

Ammonia and Propylene Loop Heat Pipes with Thermal Control Valves Thermal/Vacuum and Freeze/Thaw Testing

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

Thermal Performance of a Loop Thermosyphon

Welcome to the World of Aavid Heat Pipes

American International Journal of Research in Science, Technology, Engineering & Mathematics

PASSIVE THERMAL MANAGEMENT FOR A FUEL CELL REFORMING PROCESS

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

Compression of Fins pipe and simple Heat pipe Using CFD

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Heat Transfer in Evacuated Tubular Solar Collectors

Optimization of Various Thermal Management Techniques for High Thermal Loads

How Wicks and Orientation

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe.

Heat sinks for electronic cooling applications

Heat Dissipation in Control Panel using Heat Pipe

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

Passive Control of a Loop Heat Pipe with Thermal Control Valve for Lunar Lander Application

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

PASSIVE CONTAINMENT COOLING: MODEL EXPERIMENTS

Chapter 8. Production of Power from Heat


Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

DESIGN CONSIDERATIONS WHEN USING HEAT PIPES

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Basic CFD model of heat pipe

Development of a meter-scale U-shaped Oscillating Heat Pipe for GAPS

LAMINATION AND CHARACTERIZATION OF A POLYETHYLENETEREPHTHALATE FLEXIBLE MICRO HEAT PIPE

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

CHAPTER 2 LITERATURE REVIEW

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

Development of the Micro Capillary Pumped Loop for Electronic Cooling

Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

PERFORMANCE OF WATER FILLED THERMOSYPHONS BETWEEN OC

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

The Isobar System from Acrolab...

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

TRANSIENT MODELING OF HYBRID LOOP HEAT PIPE SYSTEMS WITH MULTIPLE EVAPORATORS

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Minco SmartHeat SLT Self-Limiting Thin-Film Heater Technology

Passive cooling of telecommunication outdoor cabinets for mobile base station

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

DEVELOPMENT OF HEAT PIPE LOOP TECHNOLOGY FOR MILITARY VEHICLE ELECTRONICS COOLING

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

AFRL-RB-WP-TR

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Research Article Analyzing the Heat Transfer Property of Heat Pipe Influenced by Integrated Cooling Apparatus

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

EXPERIMENTAL STUDY ON THE LOOP HEAT PIPE OPERATING UNDER HORIZONTAL ORIENTATION

Space-grade 3D Metal Printed Heat Exchangers

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

HEAT PIPES

Mallikarjun 1, Anandkumar S Malipatil 2

This is a repository copy of Development of cryogenic loop heat pipes: A review and comparative analysis.

SCIENCE CHINA Technological Sciences

Heat Pipe Applications Introduce

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Vacuum Tube Liquid-Vapor (Heat-Pipe) Collectors

Micro capillary pumped loop system for a cooling high power device

I

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

To investigate the surface properties for increasing efficiency of solar water heater

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Refrigeration Technology in Building Services Engineering

10 K Airborne Cryocooler and

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

Technical Development Program

FORCED AIR CONVECTION THERMAL SWITCH CONCEPT FOR RESPONSIVE SPACE MISSIONS

Closed Loop Pulsating Heat Pipe with a Hydrocarbon as Working Fluid: A Review

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

THERMAL TESTING OF A 3D PRINTED NON-UNIFORM HEATSINK AGAINST STATE-OF- THE-ART FINNED GEOMETRY

Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Transcription:

High Temperature Water Heat Pipes for Kilopower System Derek Beard 1, William G. Anderson 2, Calin Tarau 3, Mohammed Ababneh 4, Brian Schwartz 5, and Kuan-Lin Lee 6 Advanced Cooling Technologies, Lancaster, PA, 17601 NASA Glenn Research Center is examining small fission power systems that address the gap between Radioisotope Power Systems (RPS) and Fission Surface Power Systems (FPS) for future spacecraft applications and Lunar and Martian surface missions. The Kilopower system, operating in the 1 to 10 kwe range, uses alkali metal heat pipes to supply heat to Stirling convertors to produce electricity and titanium water heat pipes to remove the waste heat and transport it to the radiators where it is rejected to space. The design of the heat pipes must allow for testing of the Kilopower system on earth, operation in space, survival during launch, and adverse orientations (evaporator above condenser). Advanced Cooling Technologies, Inc. (ACT) is designing and fabricating hybrid screen-groove titanium water heat pipes as solely grooved wicks are insufficient for the varied operating environments. This paper reports on the fabrication and test results for the titanium water heat pipes and radiators and future development efforts. A screened annular evaporator which interfaces to the cold end of the Stirling convertor was designed, fabricated, and welded to the grooved heat pipe previously developed. The hybrid heat pipe was then tested for heat transport capability. Heat pipe radiators were fabricated by joining solid aluminum facesheets to titanium heat pipes using S-Bond. The heat pipe radiators were cycle tested under vacuum for bond integrity and performance tested in ambient conditions for radiator effectiveness. CCHP FSPS RPS VCHP ACT CTE NCG Nomenclature = Constant Conductance Heat Pipe = Fission Surface Power System = Radioisotope Power System = Variable Conductance Heat Pipe = Advanced Cooling Technologies, Inc. = Coefficient of Thermal Expansion = Non-Condensable Gas I. Introduction ASA Glenn Research Center is examining small fission power systems, such as Kilopower, for future Nspacecraft applications and Lunar and Martian surface missions. These systems are designed for operation from 1 to 10 kwe to address the technology gap between Radioisotope Power Systems (RPS), which operate below 500 We, and Fission Surface Power Systems (FSPS), which operate above 10 kwe. The Kilopower design, example shown in Figure 1, utilizes alkali metal heat pipes to transfer thermal energy from the fission reactor to the Stirling convertors for electrical generation and titanium water heat pipes to transfer waste heat to radiators for rejection to space. The Kilopower titanium water heat pipes must accommodate four different operation conditions and orientations: 1. Operation in space under zero-gravity. Liquid returns from the condenser to the evaporator by capillary forces in the wick. 1 R&D Engineer, Defense and Aerospace Products, 1046 New Holland Ave, 2 Chief Engineer, 1046 New Holland Ave, AIAA Member 3 Lead R&D Engineer, Defense and Aerospace Products, 1046 New Holland Ave, 4 R&D Engineer, Defense and Aerospace Products, 1046 New Holland Ave, 5 R&D Engineer, Custom Products, 1046 New Holland Ave, 6 R&D Engineer, Defense and Aerospace Products, 1046 New Holland Ave, 1

2. Operation on earth with a slight adverse orientation to estimate zero-gravity performance. Liquid returns from the condenser to the evaporator, overcoming gravitational forces, by capillary forces in the wick. Typical adverse elevations are 0.1, 0.2, and 0.3 in. 3. Operation on ground in an aided orientation, for system testing. Liquid returns from the condenser to the evaporator by gravitional forces. 4. Restart after launch orientation significant adverse orientation. The wick deprimes during launch, and must reprime in space for operation. Figure 1. Kilopower 1 kwe Design. 1 Previous surface fission designs included heat pipes that depend on gravity forces to return condensate to the evaporator, known as thermosyphons, and therefore, were unable to work in space environments; however, the Kilopower system uses wicked heat pipes enabling surface and space operation. A. Heat Pipes A Heat pipe is a device with a hermetic envelope that contains a working fluid and an optional wick structure. Incoming heat in the evaporator vaporizes the working fluid which expands towards the condenser carrying latent heat. Once there, the vapor condenses to liquid, rejecting the latent heat. Finally, the liquid returns to the evaporator by gravity (thermosyphons) or a wick structure by capillary forces in a wick (heat pipes). The fluid circuit continues while a temperature gradient persists between the evaporator and condenser. Since the working fluid within the heat pipe is at saturated conditions, the temperature gradient within the heat pipe from end to end is generally less than 2 C. Figure 2. Illustration of Heat Pipe Operation. 2

B. Downselection of Kilopower Heat Pipe Wicks In previously reported research 2, Advanced Cooling Technologies, Inc. (ACT) identified and demonstrated two suitable wicks for Kilopower: a self-venting arterial wick and a hybrid screen-groove wick (shown in Figure 3). Test results indicate both designs met requirements in all modes of operation: against gravity, vertical and re-priming, and freeze-thaw. While the self-venting arterial heat pipe successfully carried more than the required 125 W at both slight-adverse elevations, it significantly fell short of predictions, indicating a problem with the manufacturing of the heat pipe or the original model. The hybrid screen-groove heat pipe successfully carried the required 125 W at adverse elevations and more power than predicted. In response to these results, the hybrid screen-grove wick was selected for further development for the Kilopower system. a) Hybrid Screen-Groove b) Self-Venting Arterial Figure 3. Heat Pipe Wick Structures Evaluated for the Kilopower Program. II. Heat Pipe Development and Fabrication The hybrid screen-groove heat pipe removes heat from the Stirling convertor and the rejects it to the radiator panel and is made up of four major components: the evaporator, accumulator, grooved pipe, and a Non-Condensable Gas (NCG) reservoir. The evaporator is a semi-annular screened envelope that mounts to and removes heat from the Stirling convertor. The accumulator is located within the evaporator envelope, but in an adiabatic region, and is sized to store all of the working fluid in the grooved section. The grooved pipe is routes from the evaporator to and along the radiator panel where the heat is rejected to space. In addition, the grooved pipe extends past the radiator to make a reservoir for Non-Condensable Gas (NCG) which is used to prevent vapor from freezing in the grooves during extreme startup or shutdown. A. Groove Design The grooved section of the heat pipe previously demonstrated was further refined for mass reduction and higher transport capability during this research period. Toward this end, a parametric model was developed to determine the optimal screen-groove wick structure regarding heat transport capability, temperature gradient, mass, and cost. After selection of the optimal design, a 48 in sample was fabricated and tested to validate the model. This was accomplished by a series of transport tests, varied by temperature and elevation against gravity. The heat pipe was instrumented and tested at 100, 120, and 140 C vapor temperature and at 0.1, 0.2, and 0.3 in against gravity orientation. The test results in Figure 4 show agreement with the model within 20%. 3

Figure 4. Test Results vs. Predictions for Downselected Grooved Heat Pipe Design. B. Groove Bending The Kilopower heat pipe was bent in order to interface with the Stirling convertor and radiator, since they are not in the same plane. Bending introduces local stresses that can lead to unattractive deformations or weakening or failure of the envelope. The success of the bend is mainly determined by the bending process and pipe geometry (such as the outer diameter, wall thickness, and wick structure). A more robust geometry usually requires trades with mass and transport capability while an improved bending process can allow for smaller mass and higher heat transport. In certain heat pipe applications, the pressure vessel determines the limiting geometry instead of the bending process, but not here because of the relatively low saturation pressure of water and the high yield strength of titanium. a) Novel Bending Process b) Traditional Bending Process Figure 5. Comparsion of Bending Processes for Titanium Tubing 4

During this research, a novel bending process was developed that provides a 41% mass reduction while maintaining the integrity of the envelope. Figure 5 compares two 0.625 in diameter samples of titanium tubing with 0.020 in wall thickness by bending process. Figure 5a shows the novel bend process sample has a smooth bend with little change in cross-sectional geometry, contrasted with the traditional bend sample, Figure 5b, that has a crumpled envelope throughout the bend. C. Hybrid Screen-groove Fabrication The hybrid screen-groove heat pipe design is constructed from four 12 in sections of grooved 0.625 in outside diameter titanium tube with 0.02 in walls that are joined together and the screened semi-annular evaporator for the Stirling convertor. The evaporator is cylindrical with two internal wicks: a fine screen for pumping liquid to the heat transfer surface and a coarse screen for liquid storage when the heat pipe is not operating, called the accumulator. Therefore, the hybrid screen-groove heat pipe has three wick structures in total: grooves, fine screen in evaporator, and an accumulator within evaporator; these are shown in Figure 6. The accumulator s purpose is twofold: (1) store liquid when the sink temperature drops below the freezing temperature of water in order to prevent damage to the grooves from liquid to solid expansion, and (2) ensure sufficient liquid in the evaporator during startup. The accumulator is sized to hold the entire liquid volume in the grooves. Figure 6. Cross-section of Evaporator, Accumulator, and Groove Components. III. Heat Pipe Test Results The test setup for the hybrid heat pipe was designed so that little to no changes were required between the tests. The hybrid heat pipe was mounted to a tilt table and instrumented with type T thermocouples. Power was applied to the heat pipe by an aluminum heater block with four cartridge heaters. Aluminum blocks with coolant passages for nitrogen were used to remove heat from the heat pipe in place of radiators. The heat pipe was instrumented according to Figure 7. 1-9, 23-26 Condensers 30 11 29 12 28 13 27 14 17 15 16 Al Heater Block 10 36 35 34 33 32 31 18 19 20 21, 37-39 Figure 7. Thermocouple Layout for Hybrid Screen-Groove Heat Pipe. A. Power Test Results In order to evaluate the performance in space, the heat pipe was tested at an adverse inclination of 0.1 in and 0.2 in, with the results from the 0.1 in shown in Figure 8. The hybrid screen-groove heat pipe showed signs of parital dryout at 450 W (at about 1050 sec) with the divergence of thermocouple 9; however, this is well above the nominal design power of 125 W and the required power of 250 W for adequate margin. 5

500 225.0 450 200.0 400 175.0 350 150.0 300 125.0 250 100.0 200 75.0 150 50.0 100 25.0 50 0.0 0 200 400 600 800 1000 1200 1400 1600 1800 Power (W) Temperature ( C) 250.0 0 2000 TC 2 TC 3 TC 4 TC 5 TC 6 TC 7 TC 9 TC 10 TC 12 TC 13 TC 14 TC 15 TC 16 TC 18 TC 19 TC 20 TC 22 TC 23 TC 25 TC 26 TC 27 TC 28 TC 29 TC 30 TC 31 TC 32 TC 33 TC 34 TC 35 TC 36 Power Time (sec) Figure 8. Performance Test of Hybrid Screen-Groove Heat Pipe. B. Vertical Orientation and Re-priming Tests The heat pipe was oriented vertically, with the condenser above the evaporator, in order to simulate the ground testing of the Kilopower system. In this orientation, the heat pipe is acting as a thermosyphon, where gravity is driving the liquid return from the condenser to the evaporator; however, before operation begins, the grooves deprime since their wicking potential is unable to overcome the gravity head and the liquid coalesces into a puddle at the bottom of the heat pipe. This puddle can lead to pool boiling or flooding when the thermosyphons begin operating, causing a high temperature gradient or heat transport limitations. The accumulator prevents these phenomena by storing the puddle as seen in Figure 9. 140.0 400 350 120.0 300 250 80.0 200 60.0 150 40.0 100 20.0 50 0.0 0 100 200 300 400 500 600 700 800 900 0 1000 Time (sec) Figure 9. Vertical Orientation Test of Hybrid Screen-Groove Heat Pipe. 6 Power (W) Temperature ( C) 100.0 TC 2 TC 3 TC 4 TC 5 TC 6 TC 7 TC 9 TC 10 TC 12 TC 13 TC 14 TC 15 TC 16 TC 18 TC 19 TC 20 TC 22 TC 23 TC 24 TC 25 TC 26 TC 27 TC 28 TC 29 TC 30 TC 31 TC 32 TC 33 TC 34 TC 35 TC 36 Power

C. Freeze-Thaw Testing In order to simulate the conditions of an extended shutdown and restart of the Striling convertors in space, the hybrid screen-groove heat pipe was chilled to -50 C and then heated with the nominal design power of 125 W to the operational temperature of 125 C. The test results in Figure 10 show a smooth startup from frozen condtions and stable performance at operational temperature. Figure 10. Freeze-Thaw Test of Hybrid Screen-Groove Heat Pipe. IV. Radiator Development and Fabrication The hybrid heat pipe interfaces to a radiator that rejects the waste heat from the Stirling convertor to space. Since traditional radiator designs were cost-prohibitive for this research, ACT investigated directly bonding aluminum facesheets to the titanium heat pipe via a high temperature solder called S-Bond. S-Bond Technologies, LLC performed the joining process on sample heat pipes and radiators. These samples were tested to determine the integrity and thermal characteristics of the bond. A picture of a S-Bonded heat pipe radiator is shown in Figure 11. The large Coefficient of Thermal Expansion (CTE) mismatch between titanium and aluminum causes warping of the components, most readily visible on the aluminum. Figure 11. S-Bonded Titanium Heat Pipe to Aluminum Facesheet. V. Radiator Test Results A 0.75 in outer diameter titanium tube was bonded to an 0.040 in thick aluminum sheet for testing. This article was mounted to a tilt table, charged with water, and instrumented with type T thermocouples as shown in Figure 12. An aluminum heater block with a single cartridge heater was used as the evaporator. The article was then tested in ambient and vacuum environments. 7

Power (W) Thermal Resistance ( C/W) Figure 12. Thermocouple Layout on S-Bonded Titanium - Aluminum Heat Pipe Radiator. A. Thermal Cycle Testing Since the heat pipe and radiator are rigidly connected, the large CTE mismatch between the titanium heat pipe and the aluminum radiator induces significant shear stress in the bond, which could cause it to fail. In order to investigate bond strength, the test article was thermally cycled from 40 to 140 C under vacuum. The article was cycled continuously 19 times. Figure 13 shows the temperature evolution during the cycling testing. Figure 13. Temperature Evolution of Thermal Cycle Testing of S-Bonded Heat Pipe Radiator. Average thermal resistance across the bond joint was determined during the steady state for each cycle of the test and plotted for comparsion, as shown in Figure 14. The data shows that the thermal resistance is relatively consistent throughout each cycle. Noise in the thermal resistance is attributed to noise in the power. Based on the results above and visual inspection, it was determined the quality of the bond was not altered by the exposure to thermal cycling. 165 160 155 150 145 140 135 130 125 120 0.0200 0.0190 0.0180 0.0170 0.0160 0.0150 0.0140 Power 0.0130 Resistance 0.0120 0.0110 0 5 10 15 20 Cycle # Figure 14. Thermal Resistance History of Cycled S-Bond Heat Pipe Radiator. 8

B. Thermal Imaging Testing The article was tested in ambient in order to determine the uniformity of the bond by thermal imaging. Constant power was applied to the evaporator until the article reached steady-state by cooling from natural convection. Figure 15 below shows the temperature evolution of the test and a thermal image corresponding to 4500 sec into the test. The thermal image shows the root of the fin is isothermal and temperatures at corresponding locations on the fins are within 5 C. A few outliing cold spots are shown on the fins, predominately at the tips and bottoms of the fins. These effects can be attributed to local irregularities in the natural convection boundary layer. Overall, results show an acceptable thermal bond between the hybrid screen-groove heat pipe and radiator. Figure 15. Thermal Image of S-Bonded Heat Pipe Radiator. VI. Conclusion The hybrid screen-groove heat pipe was successfully tested in all modes of operation: against gravity, gravity aided in vertical orientation, and freeze-thaw. During the against gravity test, the heat pipe carried 390 W before partial dryout, and 450 W with partial dryout, which is significantly greater than the 125 W nominal power and the 250 W requirement. The vertical orientation test demonstrated the capability of the accumulator to store the liquid from the grooves that deprimed. During the test, the startup from room to operating temperature was smooth and the steady-state data was stable. The heat pipe also showed a smooth startup from frozen conditions to operating temperature and stable performance at steady state. Based on the test results, the hybrid screen-groove heat pipe issuitable for Kilopower, successfully operating as a thermosiphon for ground testing and slightly inclined against gravity for space operation. The radiator directly bonded to the hybrid screen-groove heat pipe with S-Bond was tested for thermal performance and bond strength by thermal cycle testing. After thermal cycle testing, the bondline showed no signs of damage and thermal imaging during a steady-state test revealed uniformity throughout the bond. While the large CTE mismatch between the heat pipe and radiator caused warping, there was no negative effect on the thermal performance; however, structural and assembly issues are envisioned. Through this testing, S-Bond proved to be a viable low-cost alternative to standard radiator constructions with the exception of significant warping of the components. Acknowledgments This research was sponsored by NASA Glenn Research Center under Contract No. NNX15CC06C. Any opinions, findings, and conclusions or recommendations expressed in this article are those of the authors and do not necessarily reflect the views of the National Aeronautics and Space Administration. We would like to thank Maxwell Briggs who was the contract technical monitor. Phil Texter was the technician for this project. 9

References 1 L. Mason, M. Gibson, and D. Poston, Kilowatt-class Fission Power Systems for Science and Human Precursor Missions, Nuclear and Emerging Technologies for Space (NETS-2013), Albuquerque, NM, February 25-28, 2013. 2 R. Hay and W. Anderson, Water-Titanium Heat Pipes for Spacecraft Fission Power, International Energy Conversion Engineering Conference (IECEC-2015), Orlando, FL, July 27-29, 2015. 3 S-Bond Technologies, LLC, URL: http://www.s-bond.com 10