AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Similar documents
AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

MICROJET RECORDER (24-CHANNEL 180mm)

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Temperature Controllers

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

SHIMADEN DIGITAL INDICATORS

I/A Series 716C 1/16 DIN Temperature Controller

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Series Temperature Controller Instruction Sheet

TEMPERATURE CONTROLLER

Universal controller for panel mounting Models CS6S, CS6H, CS6L

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

JW SERIES. Three Phase Thyristor Regulator PSE-351

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Universal Input Digital Panel Meter With Bargraph, NA3

02/11/2015

Advanced Test Equipment Rentals ATEC (2832)

F4 Process Controller Installation and Operation Guide

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Specification , July 2015

Series Digital Controller Instruction Sheet

General Specifications

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Point recorder KS 3660

02/11/2015

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Oxygen (O2) Single-Point Gas Detection System

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

UDC 700 Universal Digital Controllers and Indicator Specifications

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

MR SERIES CARD LOGGERS

Software Version 2.01 LEVEL MONITOR MODEL 220

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

UDC100 Universal Digital Controller Specifications

Two-Channel Gas Controller

Installation Manual Tracker 221

DIGITAL INDICATOR JIR-301-M

DIGITAL INDICATOR DI25

N1540 Process Indicator

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

KH SERIES (PEN-WRITING SYSTEM)

Mark 25 Ultrapure Water Conductivity Analyzer

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

EL-USB-1-LCD Temperature Data Logger with LCD

FAHM Co. Temperature Transmitter PTT74 Series

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

Specifications Minimum Typical Maximum Unit

Digital Heater Element Burnout Detector K8AC-H

DGC-500 DIGITAL GENSET CONTROLLER

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Nov 08 PRODUCT SPECIFICATION SHEET

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

/8 DIN Universal Process Indicator

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

EasyLog Data Logger Series

Process Alarm Module RTA 421

Analog Room Pressure Monitor RPC Series

Module Features are-configurable, no module jumpers to set

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Instruction manual Temperature Controller KT7

TEMPERATURE CONTROL MODULE MODEL R3-TC2

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

EasyLog Data Logger Series

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Model 144H. Product Data Sheet , Rev DB February Content

7EF/7HF/7EC/7ES Temperature Controllers

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Danfoss gas detection Controller unit

Carbon Monoxide Transmitter

Model 1062 Environment Monitor

User s. Manual) Model VJUK Limit Alarm for Universal Input

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

E5CN/E5CN-U (48 x 48 mm)

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

eed quality electronic design USER s MANUAL

Series Multipoint Recorder. Features. The future in Data Recording Technology is available today

COMMANDER 150. User Guide Universal Process Indicator A1

Transcription:

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data, bargraph display, alarm display/printing and other unique features. Software packages of "KIDS" for data processing of measured values and PASS for programming parameters are available. FEATURES Simultaneous digital display/bargraph display up to 4 channels Simultaneous 5-digit digital displays and analog bargraphs for full scale of 4 channels allow measured data to be viewed at a glance. Universal input The recorders accept total 56 ranges of 10 DC voltage ranges, 35 thermocouple ranges and 11 resistance thermometer ranges, and these ranges can be programmed for each channel. Pen-lift function built-in Pens are automatically lifted when the printing is OFF. Pen offset correction function built-in By correcting the mechanical position difference between each pen, the time gap on a chart paper is corrected. Data acquisition software package "KIDS" The data acquisition software package "KIDS" is available for data processing by a personal computer. Engineering software package "PASS" The engineering software package "PASS" is available for programming parameters by using an engineering port. CE, UL and CSA The recorder conforms to the rules of safety standards of CE, UL and CSA (C-UL). (UL and CSA: approval pending) The front panel is the structure with water-proof and dust-proof (IP54). Communications interface The communications interface of RS-232C, RS-422A or RS-485 with MODBUS protocol is available as an optional specification. Alarm display/printing function built-in Up to 4 kinds of alarm can be set in each input independently. The digital display blinks for alarm activation, and the information of alarm activation/reset is printed on a chart paper. Other features The pen speed is 100mm/second. The illumination is built-in for easy confirmation of printed data in night or dark places. Universal power supply Detachable terminal board for easy wirings The transmitter power supply unit (separate purchase required) attached to the rear side of the recorder is prepared. 1 PSE-310

MODELS AH37 P - - A Input point 1: 1 point, 2: 2 points, 3: 3 points, 4: 4points Communications interface (option) N: None, A: RS-422A, R: RS-232C, S: RS-485 Alarm output/remote contacts (option) 0: None 1: 6 (MOS relay) alarm outputs + remote contacts 2: 6 (mechanical relay c contact) outputs + remote contact (*see note) A: 6 (mechanical relay "a" contact) outputs + remote contacts 3: 12 (MOS relay) alarm outputs + remote contacts 4: 12 (mechanical relay c contact) outputs + remote contact (*see note) B: 12 (mechanical relay "a" contact) outputs + remote contacts Others (option) 0: None, 1: Printing format Math function (Option) 0: None, 1: Basic, 2: Totalizing/flow correction, 3: Basic + Totalizing/flow correction Door/case (option) 0: Standard, 1: With handle and rubber stands (*see note) Note : Not conforming to CE, UL and CSA INPUT SPECIFICATIONS Number of measuring points: 1 to 4 points Input signals: Universal input DC voltage, thermocouple, resistance thermometer DC current (by adding shunt resistors) Contacts input [remote contacts input (option up to 4 points) for operation printing for inputs] Range setup: Programming of input types and ranges by keys Scale setup: Programming of maximum values, minimum values and engineering units by keys Accuracy rating: Refer to the table of inputs. Temperature drift: ±0.01% of full scale/ºc (converted into reference ranges) Measuring cycle: About 100msec Reference junction compensation accuracy: K, E, J, T, N, Platinel li.. ±0.5ºC or less R, S, NiMo-Ni, CR-AuFe, W-Wre26, WRe5-WRe26 U, L ±1.0ºC or less (At the measurement higher than 0ºC, the above errors are added to the accuracy ratings for an internal reference junction compensation.) Burnout: For thermocouple inputs and resistance thermometer inputs Up-scale burnout, down-scale burnout or burnout disabled is selectable for each input. Input resolution: About 1/56000 (converted into reference ranges) Allowable signal source resistance: Thermocouple inputs, DC voltage inputs... 1kΩ (burnout disabled) or less Resistance thermometer inputs... 10Ω or less (per wire) (same resistance for 3 wires) Input resistance: Thermocouple inputs, DC voltage inputs about 8MΩ DC voltage more than ±5 V about 1MΩ Maximum input voltage: Thermocouple inputs, DC voltage inputs (for ±2VDC range or lower) ±10VDC or less DC voltage inputs (for ±5VDC range or higher) ±60VDC or less Resistance thermometer inputs... ±6VDC or less Input correction: Zero/span correction and shift correction for each channel Input first-order lag filter: Time constant of 0 and 1 to 10 seconds can be set in each channel. Common mode rejection ratio: 140dB or more (50/60Hz) Series mode rejection ratio: 50dB or more (50/60Hz) Terminal board: Detachable type, removable for wirings 2

PRINTING SPECIFICATIONS Printing deadband: 0.2% (of printing span) Printing system: Analog tracing Disposal cartridge pen Digital printing Plotter pen Step response: 1.5 second or shorter (90% response) Printing color: Analog tracing 1 st pen red, 2 nd pen green, 3 rd pen blue, 4 th pen brown Digital printing purple (Printing are limited by chart speed.) Periodic printing, Digital data printing (analog tracing continuance/ interruption), Date and time printing (at power on, every hour), Chart speed printing, Scale, unit and tag printing, Alarm activation/reset printing, Programming change mark, POC (pen offset correction) mark, List printing Printing ON/OFF function: ON or OFF programming can be set in the following printings. Date and time, Scale, unit and tag, Chart speed, Alarm activation/reset, POC mark Chart: Fan-fold type, effective width 180mm, total width 200mm, total length 20m Chart speed: 1 to 600 mm/hr, 1 to 200mm/min (Default: 25mm/hr) Chart speed accuracy: ±0.1% or less (to the reference of time line of chart-feeding longer than 1000mm) Skip function: No display or printing of channels of which ranges are not programmed. Printing correction: Zero and span correction of analog tracing Phase synchronizing correction: Time axis pen offset correction (POC) Subtract printing: Printing of difference between two channels or between a channel and a referenced value (programmed value) Message printing: Letters pre-programmed are printed by a key or a remote contacts (option). 5 kinds of message (time + message of maximum 15 letters) Pen-lift function: By RECORD OFF key, all pens are lifted up simultaneously. At the power OFF, the pen status just before the power OFF is kept. A lever for manually lifting up/down of all pens is provided. DISPLAY SPECIFICATIONS Analog indication: 180mm bargraph per each input point (101 segments, Same color as analog tracing is indicated at each 10 segments.) Digital display: 16 segments LCD 1 digit, character height 7.5mm, orange 7 segments LCD 30 digits, character height 6.5mm, white -9999 to 99999 [optional decimal place, with cursor (by each analog tracing color)] Display items: Simultaneous display of 4-channel measured values, or year, month/day, hour/minute and chart speed Status display: Printing status, key lock, alarm-activation, chart end, fail and pen offset correction ALARM SPECIFICATIONS Alarm display: "ALARM" illumination, flashing of measured value at an alarm-activated channel and alarm type Alarm types: Absolute value alarm, differential alarm, rate-of- change alarm, absolute value/standby alarm and differential/standby alarm, each 2 levels Alarm programming: Individual programming for each channel Maximum 4 levels/channel Alarm deadband: 0.1 to 9.9% of scale programming range (Default: 0.1%) Alarm output: Option (Refer to the list of options.) PROGRAMMING/OPERATION Programming parameters: Time, chart speed, periodic data printing, ranges, scales, engineering units, tags, alarms, burnout, subtract printing, ºC/ ºF, password (Options: Communications, printing format, message printing, math function) Printing operation: RECORD ON/OFF.. Printing on/off FEED Fast-feeding of chart LIST List printing DATA PRINT Digital data printing Pen replacement: Pens are replaced by moving them in the pen replacement mode. Engineering port: By using the engineering software package (PASS), all parameters can be programmed by a personal computer. 3

GENERAL SPECIFICATIONS Rated power voltage: 100 to 240VAC, 50/60Hz Power consumption: Maximum 60VA Environmental conditions: Reference operating condition... 21 to 25 C, 45 to 65%RH Power voltage: 100VAC ± 1% Power frequency: 50/60Hz ± 0.5% Attitude: Left/right 0, Forward tilting 0, Backward tilting 0 Warm-up time: More than 30 minutes Normal operating condition 0 to 50 C, 20 to 80%RH Power voltage: 90 to 264VAC Power frequency: 50/60Hz ± 2% Attitude: Left/right 0 to 10, Forward tilting 0, Backward tilting 0 to 30 Transportation condition (at the packed condition on shipment from our factory) -20 to 60 C, 5 to 90%RH (No dew condensation) Vibration: 10 to 60Hz, 4.9m/s 2 or less Impact: Less than 392m/s 2 or less Storage condition -20 to 60 C, 5 to 90%RH (No dew condensation) Insulation resistance: Between secondary terminals and protective conductor terminal Between primary terminals and protective conductor terminal... Between primary terminals and secondary terminals... Between alarm terminals (mechanical relay contact c ) and other secondary terminals... Note: Primary terminals: Power (L, N), Alarm (MOS relay, mechanical relay contact a ) Secondary terminals: Input, Alarm (mechanical relay contact c ), Remote contacts, Communications 4 Dielectric strength: Between secondary terminals and protective conductor terminal... 1 minute at 500VAC Between primary terminals and protective conductor terminal... 1 minute at 1500VAC Between primary terminals and secondary terminals... 1 minute at 2300VAC Between alarm terminals (mechanical relay contact c ) and other secondary terminals... 1 minute at 1000VAC Note: Primary terminals: Power (L, N), Alarm (MOS relay, mechanical relay contact a ) Secondary terminals: Input, Alarm (mechanical relay contact c ), Remote contacts, Communications Power failure protection: Programmed parameters stored into EEPROM memory Clock circuit and POC data sustained for minimum 8 years by a lithium battery (at the operation more than 8 hours/day) Case assembly material: Door ABS resin (frame) with glass Enclosure... Steel Color: Door Black (frame - equivalent to Munsell N3.0) Enclosure.. Gray (equivalent to Munsell N7.0) Mounting: Panel mounting Weight: About 9.0kg (full options) Clock accuracy: Within ±2 minutes per 30-day (under reference operating conditions, except errors by turning power supply on or off Power voltage fluctuation: Indication fluctuation 0.1% or less (converted into reference ranges) at 90 to 264VAC Display startup characteristics: Indication difference between 30 minutes and 4 hours after power on is 0.1% or less. (converted into reference ranges except resistance thermometer input) Terminal screws: Power terminals... M4.0 Protective conductor terminals.. M4.0 Measuring input terminals. M3.5 Alarm terminals. M3.5 Remote contact terminals... M3.5 Communications terminals. M3.5 Chart illumination: By CFL STANDARDS CE: EN61326 A1 Class A EN61010-1 A2 UL: UL3111-1 (approval pending) CSA (C-UL): C22.2, No.1010 (approval pending) Front protection: Conforming to IEC529 IP54 NEMA250 type 13 (approval pending)

INPUT Input Measuring Reference Accuracy Display Input Measuring Reference Accuracy Display signals Ranges ranges ratings resolutions signals Ranges ranges ratings resolutions -13.8 to 13.8mV ±13.8mV 10µV W-WRe26 0 to 2315ºC ±69.0mV ±0.15% ± 1 digit 1ºC -27.6 to 27.6mV ±27.6mV 10µV WRe5-WRe26 0 to 2315ºC ±69.0mV 1ºC -200 to 200mV ±200mV 100µV PtRh40-PtRh20 0 to 1888ºC ±13.8mV 1ºC DC voltage -500 to 500mV ±500mV 100µV -50 to 290ºC ±13.8mV ±0.2% ± 1 digit -2 to 2V ±2V 1mV NiMo-Ni -50 to 600ºC ±27.6mV -5 to 5V ±5V 1mV -50 to 1310ºC ±69.0mV 1ºC -10 to 10V ±10V 10mV CR-AuFe 0 to 280K ±13.8mV 0.1K K -20 to 20V ±20V 10mV 0 to 350ºC ±13.8mV -50 to 50V ±50V Thermocouple 10mV Platinel II 0 to 650ºC ±27.6mV -200 to 300ºC ±13.8mV 0 to 1390ºC ±69.0mV 1ºC ±0.15% ± 1 digit -200 to 600ºC ±27.6mV -200 to 250ºC ±13.8mV -200 to 1370ºC ±69.0mV 1ºC U -200 to 500ºC ±27.6mV -200 to 200ºC ±13.8mV -200 to 600ºC ±69.0mV E -200 to 350ºC ±27.6mV -200 to 250ºC ±13.8mV -200 to 900ºC ±69.0mV 1ºC L -200 to 500ºC ±27.6mV -200 to 250ºC ±13.8mV -200 to 900ºC ±69.0mV 1ºC Thermocouple J -200 to 500ºC ±27.6mV -140 to 150ºC 160Ω ±0.15% ± 1 digit -200 to 1200ºC ±69.0mV 1ºC Pt100 (1) -200 to 300ºC 220Ω -200 to 250ºC ±13.8mV -200 to 850ºC 400Ω T -200 to 400ºC ±27.6mV -140 to 150ºC 160Ω ±0.15% ± 1 digit Resistance thermometer 0 to 1200ºC ±13.8mV 1ºC Pt100 (2) -200 to 300ºC 220Ω R 0 to 1760ºC ±27.6mV 1ºC -200 to 649ºC 400Ω 0 to 1300ºC ±13.8mV 1ºC -140 to 150ºC 160Ω ±0.15% ± 1 digit S 0 to 1760ºC ±27.6mV 1ºC JPt100-200 to 300ºC 220Ω B 0 to 1820ºC ±13.8mV 1ºC -200 to 649ºC 400Ω -200 to 400ºC ±13.8mV Pt50-200 to 649ºC 220Ω N -200 to 750ºC ±27.6mV ±0.15% ± 1 digit Pt-Co 4 to 374K 220Ω ±0.15% ± 1 digit 0.1K -200 to 1300ºC ±69.0mV 1ºC Note) Accuracy ratings are of measuring ranges at reference operation conditions. The reference junction compensation accuracy is not included with the accuracy ratings of thermocouple inputs. The indication equivalent to 200µV or 5ºC may vary under the test environment requested by EMC directive. K, E, J, T, R, S, B, N: IEC584, JIS C1602-1995 U(Cu-CuNi), L (Fe-CuNi): DIN43710 W-WRe26, Wre5-WRe26, Platinel II, CR-AuFe, PtRh40-PtRh20, NiMo-Ni: ASTM Vol.14.03 Pt100(1): IEC751(1995), JIS C1604-1997 Pt100(2): IEC751(1983), JIS C1604-1989, JIS C1606-1989 JPt100: JIS C1604-1981, JIS C1606-1986 5

Alarm output + remote contacts OPTIONS Options Alarm output Remote contacts Printing format * Communications interface Basic mathematics Totalizing/ flow correction Handle and rubber stands Explanations Three kinds of output (alarm, FAIL and chart-end) are possible. Output: 6 points Maximum contact rating: MOS relay output 240V (AC, DC), 50mA (AC, DC), resistive load a contact mechanical relay output 240V AC 0.2A, resistive load c contact mechanical relay output 240V AC 0.2A, resistive load ( c contact: not conforming to CE, UL and CSA.) By 4-point contact input (2-point common) signal, the following 6 kinds of operation are selectable. Chart speed 3-speed/chart stop, digital data print, list print, 4-point operation printing (printing of contact ON/OFF status), totalizing start/stop, 5-kind of message printing Zone printing Printing area is divided into 2 zones Compressed/ expanded printing A part of printing area of each channel is printing compressed or expanded. Automatic range-shift printing Printing range is automatically changed into a new printing area in the event of over-range or under-range 3 kinds of RS-232C, RS-422A, RS-485 (to be specified) Two kinds of protocol, MODBUS and private, are built-in. The following math-function can be executed in time order or between channels.. Arithmetic, Absolute value, Square root, Logarithm, Natural Logarithm, Exponential, Maximum, Minimum, Average, Temperature/humidity Totalizing of measured data and calculated results and correction of flow by pressure, temperature, etc. Handle and rubber stands are mounted for easy carrying (not conforming to CE, UL and CSA.) Data acquisition software package "KIDS" The "KIDS" is a software package for storing data being measured by AL3000 and AH3000 series recorders and for replaying of the stored data. Main function and features: Data processing: Up to 5 sets (max. 100 channels) Real-time data, real-time trend, historical data, historical trend and daily report Communications interfaces:rs-232c, RS-422A or RS-485 Stored data: Can be exported to Microsoft Excel, Lotus 1-2-3 and other application software. OS: Windows 95/98, Windows NT4.0 Engineering software package "PASS" The "PASS" is a software package, through a communications interface (optional) or a configuration port, for programming parameters of AL3000 and AH3000 series recorders by a personal computer. Main functions and features Input parameters: Ranges, scales, tags, engineering units, alarms, burnout Printing parameters: Chart speed, data interval, subtract printing, zone printing, compressed/expanded printing, automatic range-shift printing Operation: Message printing Others: Clock setting, temperature units (ºC, ºF), alarm deadband, communications specification (for programming through a configuration port only) OS: Windows95/98, WindowsNT4.0 DIMENSIONS 236mm for adding alarm output of MOS relay or c contact mechanical relay, and communications interface * 247mm for adding a contact mechanical relay ACCESSORIES (Separate purchase is required.) Article Content Shunt resistor for 250Ω (for 20mA) and 100Ω (for 50mA) current input Transmitter power Power supply unit for transmitters supply unit The unit is mounted on backside of RZ-TPS01 recorder. Panel cutout and minimum clearance for installation Specifications subject to change without notice. Original 2001.5 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 PHONE: +81-3-3956-2171 FAX: +81-3-3956-0915 E-mail: inter@chino.co.jp Website: http://www.chino.co.jp 6