Split System Heat Pump Product Data

Similar documents
Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Cooling Product Data

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product & Performance Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Cooling Product & Performance Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Appendix J Noise Appendix

Split System Cooling Product & Performance Data

Product Data. Split System Cooling A. November 2013

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Cooling D-EN. August 2016

Split System Heat Pump Product Data

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Heat Pump

Hyperion TM Split Systems

Product Data Split System Cooling

Illusion Split System

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Cooling/Heat Pump Convertible Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Split System Cooling Product Data XB 1000

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

36,000-62,000 BTUH Nominal Capacity

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Trane XC95m. Temperature Swings. Single Stage. Two Stage. Modulating. Desired Temperature. Time

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Vertical Upflow Horizontal Left Air Handlers

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Split System Heat Pumps Single Phase 1½-5 Tons

Commercial High-Efficiency Condensing Units

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

TECHNICAL SPECIFICATIONS

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Ruud Achiever Series Air Conditioners

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

High Heat COP. High/Low Stage

2/4CXC, 2/4CXA, 2/4TXC 2/4TXFH

PAJ3. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Modular Multi-position Air Handler

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data INDUSTRY LEADING FEATURES / BENEFITS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Transcription:

Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01

Features and Benefits Two Climatuff compressors Efficiency up to 19.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard II top shields unit WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant connections with full coil protection DuraTuff base, fast complete drain, weather proof Comfort-R mode approved ComfortLink II system, only two wire control connection Charge Assist fast/accurate charging every time Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection Start kit standard 50% or 100% capacity modulation Compressor sump heat Electronic compressor control Liquid line filter/drier Tarpaulin gray cabinet with anthracite gray top Low sound with advanced fan system and compressor sound insulator Variable speed fan motor Electronic Expansion Valve with diagnostics Demand Defrost Control with diagnostics XL Seacoast shield Service valve cover R-410A refrigerant S.E.E.T. design testing 100% line run test Low ambient cooling to 55 F as shipped 10-year limited warranty on compressor, coil, and internal functional parts (Residential Use) Extended warranties available 2008 Trane 2 22-1826-01

Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-weighted Sound Power Level [db(a)] 4 Accessory Description and Usage 5 ARI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specification Options 11 22-1826-01 3

General Data Product Specifications Model No. 1 4TWZ0024A1 4TWZ0036A1 4TWZ0048A1 4TWZ0060A1 Electrical Data V/Ph/Hz 2 230/1/60 230/1/60 230/1/60 230/1/60 Min Cir Ampacity 14 20 26 35 Max Fuse Size (Amps) 20 30 40 60 Compressors 2 - CLIMATUFF 2 - CLIMATUFF 2 - CLIMATUFF 2 - CLIMATUFF RL AMPS - LR AMPS 8.7-58 14.5-61.5 18.6-93.4 23.4-128.7 Outdoor Fan FL Amps 2.80 2.80 2.80 2.80 Fan HP 1/3 1/3 1/3 1/3 Fan Dia (inches) 27.6 27.6 26.6 26.6 Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 10/1-LB/OZ 11/3-LB/OZ 16/12-LB/OZ 15/13-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 3/4 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 Weight - Shipping 390 395 480 480 Weight - Net 340 345 430 430 Start Components YES YES YES YES Sound Enclosure YES YES YES YES Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Extreme Condition Mounting Kit BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 24 Volt Wiring Harness BAYACHP024A BAYACHP024A BAYACHP024A BAYACHP024A Refrigerant Lineset 5 TAYREFLN9* TAYREFLN7* TAYREFLN7* TAYREFLN7* 1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on ARI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 80'. Standard lift - 25' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db(a)] Low Stage Overall High Stage Overall A-weighted Sound Power Level [db(a)] A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL db - [db(a)] High Stage 63 125 250 500 1000 2000 4000 8000 4TWZ0024A1 62 70 51.4 52.3 60.1 61.8 63.7 64.9 56.6 50 4TWZ0036A1 70 72 51.3 55.5 66.2 65.3 64.9 64.7 57.9 53.6 4TWZ0048A1 71 76 51.3 55.8 68.2 68.5 69.5 72 58 50.9 4TWZ0060A1 71 76 50 58.2 66.3 70 70.1 70.8 60.7 52.4 Note: Tested in accordance with ARI Standard 270.95. (Not listed with ARI) 4 22-1826-01

General Data Accessory Description and Usage 24 Volt Wiring Harness Used to wire a communicating outdoor unit to an existing 24 Volt indoor section. Charge Assist Solenoid Kit fast/accurate charging every time. Rubber Isolators 5 large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. Low Ambient Cooling For low ambient cooling below 55 see Application Guide SSC-APG005-EN. ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. ARI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. 22-1826-01 5

Model Nomenclature Outdoor Units 4 T W Z 0 0 3 6 A 1 0 0 0 A A Gas Furnaces T U D 2 B 0 8 0 A C V 3 2 A A Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier Air Handlers Residential Refrigerant Type 4 = R-410A 2 = R-22 Application TE = Fully Convertible TG = Semi Convertible TF = Front Return TV = Vertical Product Family E = Leadership Variable Speed P = Leadership C = Replacement/Retail B = Basic Flow Control 3 = Nonbleed TXV 4 = FCCV* Feature Identifier 0 = Standard Unit F = Air-Tite D = Integrated Whole House Air Cleaner C = Communicating Air Cleaner Model Number Distinguisher Major Design Modifications Power Supply 1 = Single Phase Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect Future Option Factory Installed Heater Nominal KW Value Minor Design Modifications Unit Parts Identifier NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years. *Shipped with R-22 FCCV 4 T E E 3 C 0 5 A 1 0 0 0 A A Coils Residential Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible Coil) Coil Design X - Direct Expansion Evaporator Coil Product Family C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5" Refrigerant Line Coupling 0 - Brazed Model Number Distinguisher Major Design Change 4 T X C B 0 0 1 C C 3 H C A A Efficiency C - Standard S - Hi Efficiency (Derived from 10 SEER products) Refrigerant Control 3 - TXV - Non-Bleed Coil Circuitry H - Heat Pump Airflow Configuration A - Upflow Only U - Upflow / Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Unit Parts Identifier 6 22-1826-01

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWZ0024, 4TWZ0036, 4TWZ0048, 4TWZ0060 22-1826-01 7

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWZ0024, 4TWZ0036, 4TWZ0048, 4TWZ0060 Printed from D155833P01 Rev 00 8 22-1826-01

Electrical Data Schematic Diagrams LEGEND SYMBOLS 22-1826-01 9

Dimensions 4TWZ0 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TWZ0024A 4 1369 (53 7/8) 946 (37-1/4) 870 (34-1/4) 5/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 1035 (40 3/4) 4TWZ0036A 4TWZ0048A 4TWZ0060A 4 1369 (53 7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 1035 (40 3/4) From Dwg. D152635 Rev. 15 10 22-1826-01

Mechanical Specification Options General The 4TWZ0 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit is UL listed. Exterior is designed for outdoor application. ComfortLink II This outdoor unit contains the ComfortLink II digital communication with 2 wire connection to outdoor and Plug-n-Play set up. Charge Assist The Charge Assist indicates system Charge Status. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weatherproof CMBP-G30 DuraTuff base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high and low pressure switches. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff compressor features a 10 year limited warranty, internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels and has a 10 year limited warranty. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55 F. For low ambient cooling below 55 see Application Guide SSC-APG005-EN. Comfort Control ComfortLInk II Control with Plug-n- Play set up and 3 wire connection. 22-1826-01 11

Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 09/08