F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

GLEB Kitchen exhaust fan

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

AZN ATEX INSTALLATION AND MAINTENANCE

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

XB-EFA-8L-BK & XB-EFA-8R-BK

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

HEAT RECOVERY AIR HANDLING UNIT

VETO CLEANER 500 FLUE GAS CLEANER

INSTALLATION, OPERATION & MAINTENANCE MANUAL

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual


BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the BASIC BCRW Fan, Sizes General

Instructions for the fan motor control system, SILVER C

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

SHORT WAVE INFRARED PANEL DRYER

Snifter ATEX22 VERSION. User Manual. Distributor

SELF-PRIMING JET PUMPS

Pump WaterVISE, FloVISE

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Design and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators

Supply air unit VEKA Installation & Maintenance

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Operating Instructions

English CNA-CNB. Centrifugal fans Installation and maintenance

ACN SMOKE INSTALLATION AND MAINTENANCE

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Instructions for Robust Fiber Appendix 4 Robust sites and nodes. Ver 1.2

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Original instructions. Operation Manual & Cautions

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

TTV 4500 / TTV 4500 HP / TTV 7000

Operation and Maintenance Manual Chamber Conditioning Unit, CCU 06. Document Number: EC OM 6847 Revision: 3

Tempest TP420/180 Electric Pressure Washer

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

IEC- Direct-driven radial fans with IEC-Standardmotor

Model No: Little Devil II (inc ss)

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

Please read operating instructions carefully before use and keep it for further reference.

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

MJC Cartridge Filter Unit Operation & Maintenance

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

VEX250H with rotary heat exchanger and EXact control system

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Snifter. User Manual. Distributor

Operating instructions

V80-H Multistage Pump Instruction Manual

Part No KEMPER Filter-Master XL

Installation manual. Tumble dryers T4130. Compass Control

ENERVEX RSV CHIMNEY FAN

ENERVEX GSV GREASE FAN

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

OPERATING MANUAL 12 AXIAL FANS

Calaer Marine add-on kit manual. 2kW Calaer air heater 4kW Calaer air heater

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Sintrol Snifter A1+ Manual. Version 1.2.2

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

100 FLUEBOOST

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

USER S MANUAL. VKP Series INLINE FAN

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Smoke extraction duct of sheet steel

Original operating instructions Safety switch with guard locking AC901S AC902S

This label warns for risk of electrical shock when failing to observe.

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

X1 series Submersible Drainage Pump

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ATM Lighting sp. z o.o

STARBOX - CONDENSER UNITS

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

SuperKlean Washdown Products

Transcription:

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Contents Page User instructions 3-5 General 3 Fan installation 3-4 Maintenance 3 Electrical installation 5 Troubleshooting 5 Technical description 6-8 General 6 Classification 6 Technical specification 6 Manufacturer's declaration 6 Exploded view 7 Accessories 8 2

User instructions General The Fumex FB fan is a radial fan for the evacuation of gases, smoke and low weight particles. The fan series conforms to the protection and safety regulations in the EU's Machinery Directive. The fans boast high levels of quality and operational reliability. ALL fans undergo inspection and test operation before leaving the factory. However, risks can arise with any fan if: - it is not installed, used or maintained by trained personnel. - it is not used in the intended manner. Please note that electronic equipment is always susceptible to static electricity, high humidity, high temperatures and line failures. The equipment is supplied with high voltage. Use the isolating switch when carrying out service work on the fan. The fans are not intended for use in the evacuation of explosive gases. Fan installation Installation may only be performed by authorised personnel with regard to these installation instructions and applicable regulations. Make sure that all safety-related fan components satisfy their function. The stability of the fan must always be ensured during operation. In order to achieve optimum function, it is important for the fan's duct connections to be correctly executed. Incorrect installation can cause considerable deterioration in the fan's performance with regard to pressure drop and sound levels. In order to achieve optimum performance, we recommend that the inlet connection is a straight duct that is 5 times the diameter of the duct. If an outlet duct is used, the same applies to this. If the system requires a 90 bend in the outlet, it should deviate in the impeller's direction of rotation (see below). There is always a risk of clothes or loose items being sucked into a free-blowing fan. This can cause personal injury or damage to property. The fan is supplied with the outlet pointing as illustrated on page 1. If an alternative outlet air direction is required, the fan housing can be set in 8 possible positions. If the direction of outlet is changed, thread locking must be applied to the screws. Take great care to ensure that the impeller is not damaged when reinstalling the fan housing. In the event of outdoor installation, a drainage hole must be drilled at what becomes the lowest point in the installed fan, according to the selected outlet direction. In the case of professional installation, too, fans can produce harmful noise levels. It should also be noted that specified noise data (see separate product sheet) can be altered by the surroundings or resonance in the operating location. The fans are designed for installation in systems and therefore have no guard on the inlet. This means that the fan must not be started until it is connected to a duct. The guard installed on the outlet can be removed if you want to connect an outlet duct (see accessories on page 8). Maintenance Fumex fans have been designed for continuous use for an extended time with a high level of reliability. Like all machines, regular servicing and maintenance are required to achieve optimum function. Fumex recommends the following maintenance schedule: Component Motor Impeller Interval 6 months Check function. Replace motor if necessary. Check for any damage and clear away foreign objects if necessary. Replace impeller in the event of damage. Fan housing Check that connections are secure and clear away foreign objects. Check the drainage hole and clear if necessary. 3

Outdoor wall installation A flexible installation that optimises the pressure drop on the inlet side. Makes it possible to choose outlet direction. In the event of condensation problems, installation as illustrated is recommended. If noise levels are the priority, it is recommended to have the outlet pointing straight up, with drainage in the fan housing (for drainage see page 3). Note! The fan bracket must be made on site. An installation that is used when low noise levels are prioritised. The disadvantage of this arrangement is that the fan is located high up if the extract air duct is high. Note! The fan housing needs to be drained (for drainage see page 3). Outdoor roof installation A low-level, sideways outlet direction is suitable in the event of condensation problems. Note! The base must be made on site due to possible snow. Upwards outlet direction, suitable in the event of noise problems. Note! Drainage is required (for drainage see page 3). A high-level, sideways outlet direction is suitable when condensation is not a problem. Note! Drainage is required (for drainage see page 3). 4

Electrical installation The equipment is supplied with high voltage and must always be fitted with a safety switch for carrying out servicing work in connection with the fan. The choice of cable and cable cross-section must comply with the national requirements that apply to fixed installations. Single phase fans are supplied with the motors connected for clockwise rotation. The speed of the single phase motors CANNOT be regulated. Troubleshooting Always go through the troubleshooting schedule before contacting Fumex. This schedule contains information that makes it easy to identify faults that are simple to rectify. Set external safety switch in the off position. The fan can start up without warning following a power outage Only qualified personnel may perform servicing work on the fan. Symptom Possible fault The fan has stopped Fault in the power supply. Check the power supply. Short circuit in connection. Check for moisture in the safety switch and motor connection. Three-phase fans are supplied with the motor connected for 400V (Y-connection). D-connection Y-connection Locked impeller Check that there are no foreign objects in the fan housing. Locked impeller Check that no ice has formed in the fan housing. Locked impeller Check that the bearing in the motor is working. Loss of performance Motor winding Check for resistance between windings. In order to satisfy applicable standards, the FB fan must be fitted with a contactor and overcurrent protection. To choose the correct contactor, see page 6. If technical regulating apparatus (e.g. frequency converter) is used, the manufacturer's recommendations for avoiding interference must be observed. E.g. EMC, protective earth, cable length, cable shielding, etc.. The one phase motor is equipped with double capacitors. When the fan is not operating in full running speed, i.e. during the start-up and shut down process, the motor produces a mechanical sound, deriving from the switch between the two capacitors. This is a normal sound and it is not harmful for the motor. Debris Check that there are no foreign objects in the fan housing. Incorrect direction of rotation Check the direction of rotation. Connections Check that connections and duct routing are correct. 5

Technical description General The Fumex FB fan series is delivered in a robust box or on a wooden pallet with the required packaging material. A rating plate is affixed to the motor. The working temperature through the fan is max. 80 C and the ambient temperature between -10 to +40 C. Atmospheric humidity must not exceed 90%. The fan's motor generates heat and is fitted with a cooling fan. The inlet to the cooling fan is at the rear of the motor. Do not block the inlet. Fumex fans are designed for maximum Fumex (Energy related Products 2009/125/EC). Enclosure class: IP 55 Usage type: Conformity: Fumex FB fans conform to demands in accordance Technical specification Model Power Voltage Frequency Current Speed Power Weight factor (kw) (V) (Hz) (A) (rpm) Cos ϕ (kg) Contactor Motor protection switch FB 037-1 0,37 230 1N~ 50 2,60 2760 0,92 20 SKO 40/xxx SMB 40 FB 055-1 0,55 230 1N~ 50 3,70 2780 0,92 21 SKO 60/xxx SMB 63 FB 075-1 0,75 230 1N~ 50 4,70 2820 0,95 27 SKO 60/xxx SMB 63 FB 110-1 1,10 230 1N~ 50 6,70 2825 0,95 30 SKO 80/xxx SMB 63 FB 037-3 0,37 230 3~ 50 1,66 2755 0,81 20 - FB 055-3 0,55 230 3~ 50 2,25 2790 0,82 21 - FB 075-3 0,75 230 3~ 50 2,90 2890 0,82 27 - FB 110-3 1,10 230 3~ 50 4,00 2890 0,83 30 - FB 220 2,20 230 3~ 50 7,60 2890 0,85 46 - FB 037-3 0,37 400 3~ 50 0,96 2755 0,81 20 SKO 17/xxx SMB 16 FB 055-3 0,55 400 3~ 50 1,30 2790 0,82 21 SKO 17/xxx SMB 16 FB 075-3 0,75 400 3~ 50 1,60 2890 0,82 27 SKO 25/xxx SMB 25 FB 110-3 1,10 400 3~ 50 2,30 2890 0,83 30 SKO 40/xxx SMB 40 FB 220 2,20 400 3~ 50 4,30 2890 0,85 46 SKO 60/xxx SMB 63 FB 400 4,00 400 3~ 50 7,40 2910 0,88 48 SKO 100/xxx SMB 100 FB 750 7,50 400 3~ 50 13,50 2940 0,89 66 SKO 180/xxx SMB 180 6

5 4 a,b 3 4 6 2 6 a,b,c 7 1 a,b,c 1 3 a,b 2 a,b,c 7 a,b,c 1. Bracket 1 a. Bolt 4 a. Bolt 2. Motor 1 b. Washer 4 b. Washer 3. Motor plate 1 c. Nut 6 a. Bolt 4. Impeller 2 a. Bolt 6 b. Washer 5. Fan housing 2 b. Washer 6 c. Rivet nut 6. Inlet 2 c. Nut 7 a. Carriage bolt 7. Outlet grating 3 a. Bolt 7 b. Washer 3 b. Rivet nut 7 c. Nut 7

Mounting plate, FBF Intended to be used for simple, safe mounting of fans on walls made of uneven material, e.g. corrugated metal. Supplied complete with vibration dampers for optimum function. FBF 110 - Fits FB 037, 055, 075 and 110. FBF 750 - Fits FB 220, 400 and 750. Steel (SS-EN 10025 S235JR) Surface treatment: Hot-dip galvanized Weight FBF 110: 20 kg Weight FBF 750: 23 kg Outer dimensions 650 x 650 x 30 mm Outer dimensions 670 x 770 x 30 mm Connection, FBD Intended to be used to prevent the spread of structure-borne noise. Supplied complete with hose clip. Vibration damper, FBV FBD 055 - Fits FB 037 and 055. FBD 110 - Fits FB 075 and 110. FBD 220 - Fits 220. FBD 400 - Fits FB 400. FBD 750 - Fits FB 750. Intended to be used to prevent the spread of vibrations, which can result in increased noise levels. Outlet transition piece, FBO FBV 110 is compatible with FB 037-FB 110. FBV 750 is compatible with FB 220-FB 750. Intended to be used for simple and optimised transition when a round outlet duct is to be connected. Supplied complete with installation components. FBO 037 - Fits FB 037. FBO 055 - Fits FB 055. FBO 075 - Fits FB 075. FBO 110 - Fits FB 110. FBO 220 - Fits FB 220. FBO 400 - Fits FB 400. FBO 750 - Fits FB 750. PVC membrane reinforced with polyester mesh Weight: ~0.1-0.2 kg Outer dimensions FBD 055: Ø164 x 125 x 0.5 mm Outer dimensions FBD 110: Ø204 x 125 x 0.5 mm Outer dimensions FBD 220: Ø254 x 125 x 0.5 mm Outer dimensions FBD 400: Ø404 x 150 x 0.5 mm Outer dimensions FBD 750: Ø504 x 150 x 0.5 mm EPDM rubber with mounting components made of chromated steel. Weight: ~0.25 kg Outer dimensions FBV 110: Ø40 X 30 mm / M8 Outer dimensions FBV 750: Ø50 X 30 mm / M10 Steel (SS-EN 10025 S235JR) Surface treatment: Hot-dip galvanized Weight: ~1.2-5.1 kg Outer dimensions FBO 037: 171 x 230 x 195 (Ø160) mm Outer dimensions FBO 055: 195 x 230 x 195 (Ø160) mm Outer dimensions FBO 075: 208 x 252 x 245 (Ø200) mm Outer dimensions FBO 110: 205 x 280 x 245 (Ø200) mm Outer dimensions FBO 220: 220 x 311 x 255 (Ø250) mm Outer dimensions FBO 400: 280 x 401 x 345 (Ø400) mm Outer dimensions FBO 750: 323 x 441 x 445 (Ø500) mm Safety switch, SSB 750 Safety switch lockable with locking lever. Supplied with 2 lead-in M25 PC Weight: 0,3 kg Outer dimension SSB 750: 138 x 63 x 118 mm SSB 750 - Fits all sizes. 8