S3 Sim Secual Alarm system with GSM transmitter

Similar documents
S3b Sim Secual / S3b Sim Vid Secual GSM Alarm System

INSTALLATION AND USER MANUAL SG2. GSM+WiFi. Alarm Security System

S4 Combo Secual / S4 Combo Vid Secual GSM and Landline Alarm System

Flash 3 times per 3 seconds: Under voltage indication, please


SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

MOBILE CALL GSM Alarm System User s Manual

1. Introduction. 2. Product overview

EM8710 GSM Alarm System Starter Kit

GSM RFID VOICE Alarm System

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 Plus WiFi Alarm System User Manual

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

System. For a better understanding of this product, please read this user manual thoroughly before using it.

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

Security GSM Alarm System

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

D3D Wi-Fi GSM Smart Alarm System -User Manual

GSM-SMS-APP Smart Touch Alarm System

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

PiSector GSM Cellular Wireless Alarm System

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

Intelligent Wireless GSM Alarm System

INSTALLATION AND OPERATING MANUAL

Wireless Alarm system s manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

AG HOME ALARM Quick Start Guide

User Manual (LS-GSM-006)

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

WiFi GSM APP Smart Home Security System

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Smart Security, Always Connected

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

CONTENTS. (User s Manual)

Content. Chapter 1 Knowing the alarm host 1.1 Features 1.2 Technical Parameters 1.3 Packing List 1.4 Knowing the alarm host

Touch Keypad GSM Smart Alarm System USER MANUAL

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

Cellular + Wi-Fi Smart Security System

Elderly Care Alarm System

USER MANUAL BEFORE INSTALLING AND USING THIS SYSTEM,

K1 SMARTHOME DIY KIT

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

S6 Titan Security System. Wi-Fi and 3G GSM

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

G4S SMARTalarm User Guide

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

Dual-Network LCD Keyboard Intelligent Alarm

SA 2650 Kit User Manual

Training 2 nd part. Agenda for second part

SECURE HOME SYSTEMS PLUG & PLAY... SECURE... AND WALK AWAY ONLY ALARMS TO BE RECOMMENDED BY THE NEIGHBOURHOOD WATCH

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued:

The complete wirefree security alarm solution

GSM CAR ALARM SYSTEM USER S MANUAL

2G & 3G GSM Portable PIR Alarm

User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

Wireless Keypads LKP(E)S8M Series

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

K1 SMARTHOME DIY KIT

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

DIY Smart Home Security Kit 18-K1

HomeSecure HS-BASIC-V2 Installation Manual: Table of Contents


2G & 3G GSM Door Contact Alarm

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

Contents. Contents

Alarm System SECURE AS 302

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

WiFi + PSTN. Smart Home Alarm System

GSM-SD WITH CALL,SMS,MMS MANUAL

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

>WIRELESS> ALARM SYSTEM CR200

Contents Description... 3 AZOR kit contents... 4 Installation... 7 Control Settings System extension Other information...

Cellular + Wi-Fi Smart Security System USER S GUIDE

Mobeye CM2410 GSM fire alarm communicator

Wireless Keypad GKP-S8M

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

DYGIZONE GJD910 Lighting Controller & Enunciator

SECURITY SYSTEM. User's Manual. Model: G70-ULTIMATE. K Rev. A

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

JA-63 Profi User manual

3 User s settings. 3.3 Internal clock setting

13. The wireless coding and timing arm and disarm settings Function Setting First / second group of time arm set 1.

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

EWP2WIRELESS MOTION DETECTOR

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

Contents. Glossary

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

DIY Home Security Support 30 numbers wireless sensors

Transcription:

S3 Sim Secual Alarm system with GSM transmitter www.etiger.com

Features Control Panel Layout (Back) - ARM CPU + Auror CPU - GSM frequency: 850 / 900 / 1800 / 1900 MHz, suits all phones - Supports up to 10 remote controls, 50 wireless accessories and 50 RFID tags - Radio-frequency security of the accessories: more than one million code combinations - Built-in siren (110dB) and call function from the panel - Arm / disarm the system by SMS, phone call, or application (on ios or Android) - Stores up to 5 phone numbers, 1 speed dial phone number and 1 SMS number for RFID tag notifications - Grid failure SMS alert - Accessory low-battery SMS alert - Built-in 800 mah lithium batteries (5h battery life in standby mode) MIC Siren / Speaker Tamper Switch Loudspeaker SIM Card Slot Input for Wired Sensors (24-hour zone) Input for Wired Sensors (normal zone) Output for Electronic Lock Output for Wired Siren 500mA Adapter Interface Control Panel Layout (Front) Back-up Batteries Power On/Off GSM Signal Indicator Searching GSM network: Blinks once every second GSM signal is normal: Blinks once every two seconds Box Content Touch Keypad Status Indicator S3 Panel x1 AC Adapter x1 PIR Motion Detector x2 Door / Window Contact Detector x2 Remote Control x2 RFID tag x2 Documentation x1 Record / Play Voice Memo RFID player / Play Voice Memo Arm Disarm Call Stay Arm (Home Mode) Record Voice Memo / Connect Button Long press the Record Voice Memo button { } to record a 10-second voice message. The voice message can also be recorded by sending an SMS to the system, as explained in page 7 of this manual. The Play Voice Memo Button blinks when a message has been recorded. Touch the centrer of the circle on the control panel to listen to the voice memo. The LED indicator turns off when the voice memo is being played. Touch it again to replay the memo. 2 3

RFID Tag SMS Operations Request the Menu The RFID tag can disarm the system and unlock the electronic door (if connected to a wireless keyboard). You can rename RFID tags and store a mobile phone number that will receive an SMS notification when the system is disarmed with a RFID tag. To start receiving an SMS notification when the system is disarmed by RFID tag, you must store an SMS number and rename the RFID tags (up to 4 RFID tags can be renamed). Speed Dial Nancy Mom Administrator Nancy came home Press the Call Button { }: the panel auto-dials the pre-stored phone number. Press the Call Button { } to end the call. The LED turns off after the call. Phone Call Important Insert a SIM card in the control panel before starting SMS operations. Make sure the SIM card does not request any PIN code.... Each SMS operation included in this user manual will be illustrated as follows: You send: SMS Command? The system sends the first part of the menu: 0 Disarm 1 Arm 2 Home mode 3 Two-way talk 4 Call-back voice memo 00 Settings inquiry?? Store phone and SMS No?? Dial a phone number and press the Call Button to start the call. Press the Call Button to finish the call. Electronic Lock When you disarm the system, the output signal of the panel opens the electronic lock automatically. The first blue speech bubble is the SMS command sent by the user. The control panel replies: Control panel s reply The first grey speech bubble is the reply sent by the control panel. The speech bubbles that follow are the dialogue between the user and the control panel (SMS sent by the user are in blue, SMS sent by the control panel are in grey). The system is in English as per default setting. To change the system s language, refer to page 13. The system sends the second part of the menu: 5 Store phone No. 6 Store alarm SMS No. 7 Store SMS No. for RFID tags 8 Store speed dial phone No.??? System setups 4 5

Home Mode Call Back to Record a Voice Memo Store Phone Numbers??? The system sends the third part of the menu: 2 4 5 91~99 Zone name 10 RFID tags SMS notice 11 Entry and exit delay time 12 Siren volume and ringing time 13 Disarm password 14 Single zone delay time System in home mode. Two-Way Talk The system will call you back. Pick up the phone and leave a 10-second message. The call end automatically after 10 seconds. Settings Enquiry TEL: 1. 2. 3. 4. 5. Disarm the System 0 System disarmed. Arm the System 3 The system will call you back. Pick up the phone and start the two-way talk. 00 System status Entry and exit delay time: 0sec Single zone delay time: 30sec Siren volume: 2 Siren ringing time: 5min Disarm password: 1234 TEL: 1. 67890033 2. 67890022 3. 67890011 4. 67890000 5. Store alarm phone No. The value of default settings will be changed after having set up the system. 1 System armed. 6 7

Store Alert SMS Number Store SMS No. for RFID Tags Notifications Store Speed Dial Phone Number Change Zone Name Send 91~99. For example for zone 1, send: 6 7 8 91 SMS: 1. 2. 3. 4. 5. SMS No. for RFID tags: (0-20 digits):1 Speed dial phone number: (0-20 digits):1 Zone 1 name : Zone 1 alarm SMS No. for RFID tags: (0-20 digits): 1. 67890033 Speed dial phone number: (0-20 digits): 1. 67890033 Zone 1 name : Entrance door sensor SMS: 1. 67890033 2. 67890022 3. 67890011 4. 67890000 5. Store alarm SMS No. Store SMS No.for RFID tags To start receiving an SMS notification when the system is diarmed by RFID tag, you must store an SMS number and rename the RFID tags (up to 4 RFID tags can be renamed). Other tags will be attributed a number based on the order of registration to the control panel. Refer to the instructions page 14 to learn how to register an RFID tag in the control panel. Store speed dial phone number Change zone name seccessfully The user can rename zones 1 to 9. The name of the zone cannot consist of more than 30 English characters per line due to SMS character limit. Zone 10 to 50 cannot be renamed. 8 9

SMS Alert for Accessory Low Battery (available for two-way acessories such as Motion Detectors) Rename RFID Tag for SMS Notice Entry and Exit Delay Time Siren Volume and Ringing Time For accessories assigned to zones that have been renamed, an SMS will be sent under the format Zone name + low battery. 10 11 12 Bedroom PIR low battery For accessories assigned to zones that have not been renamed, an SMS will be sent under the format Zone number + low battery. Zone 10 low battery. SMS Alert for Accessory Tamper Alarm (available for two-way acessories such as Motion Detectors) Change RFID Tag SMS Notice : 1. 2. 3. 4. Change RFID Tag SMS Notice : 1. Tom 2. Nurse 3. Nancy 4. David Entry and exit delay time (0-300 sec.): 0 Entry and exit delay time (0-300 sec.): 30 Set delay time Siren volume (0 Mute, 1 Low, 2 High): 2 Siren ringing time (1-9min): 5 Siren volume (0 Mute, 1 Low, 2 High): 2 Siren ringing time (1-9min): 5 For accessories assigned to zones that have been renamed, an SMS will be sent under the format Zone name + tamper alarm. Bedroom PIR tamper alarm. For accessories assigned to zones that have not been renamed, an SMS will be sent under the format Zone number + tamper alarm. Change RFID Tag SMS Notice To start receiving an SMS notification when the system is diarmed by RFID tag, you must store an SMS number and rename the RFID tags (up to 4 RFID tags can be renamed). Other tags will be attributed a number based on the order of registration to the control panel. Refer to the instructions page 14 to learn how to register an RFID tag in the control panel. This function can be used if you do not want to bring a remote control or RFID tag with you. When the system is being armed, one beep will be heard every second to remind you to leave. The beep rhythm will speed up during the last 15 seconds. If an intruder is detected, the alarm will be delayed accordingly. Set siren volume and ringing time Zone 10 tamper alarm. 10 11

Disarm Password Single Zone Delay Time Change system language Delete RFID Tags by SMS Send 0033 to set the language system as French 13 14 0033 22 Disarm password (4-6 digits): 1234 Single zone delay time (0-300 sec.): 30 Réglage de la langue français réussi. Delete RFID tags successfully Disarm password (4-6 digits): 8888 Send 0001 to set the language system as English Press the Tamper Switch at the back of the control panel 3 times in 3 seconds, both wireless accessories and RFID tags will be deleted. Two beeps indicate that the accessories and RFID tags have been deleted. Set disarm password Single zone delay time (0-300 sec.) : 15 Set single zone delay time 0001 Set English Restore System to Default Settings by SMS This function will only affect the detectors assigned to the Single Delay Zone (Zone B). To learn how to assign a detector to a Single Delay Zone, please refer to the paragraph Zone Setup of Wireless Accessories of this User Manual (page 16). Delete Wireless Accessories by SMS 21 Delete wireless accessories 0000 System has been restored to factory settings. Press the Tamper Switch at the back of the control panel 5 times in 3 seconds, the system will be restored to factory settings. Two beeps indicate that the system has been restored to factory settings. Only stored numbers can send SMS to restore the system. 12 13

Arm & Disarm by Phone Call Arm Call the control panel number and hang up when you hear the ring tone: the system is armed. Disarm Call the control panel number and hold on until the panel ends the call: the system is disarmed. Register Wireless Accessories & RFID Tags Type your 4-digit password. Press the Connect Button { } on the control panel: the LED indicator lights up. Trigger the accessory (for the RFID tag, swipe it in front of the blue circle of the control panel) once within 15 seconds. You hear one beep: the registration is successful. Default password is 1234. If the accesory has already been registered, the control panel will beep twice. The first accessory registered is assigned to zone 1, the second accessory registered is assigned to zone 2, etc. Zones 1 to 9 can be renamed. Zone 10 to 50 cannot be renamed. Register Wireless Siren Operation Press the Arm Button on the remote control to make sure that the internal siren and wireless siren both beep once. If so, they are registered. If not, the registration has failed; register them again. If an intruder is detected, both the internal siren and the wireless siren will ring out. (The siren will turn off after 5 minutes, as per default setting). Important When the alarm is triggered, the alarm system sends an SMS and calls the stored numbers. If one of the users answers the call, the siren stops immediately and audio monitoring of the site starts. Alarm System Specifications Product name S3 Sim Secual Model S3-S Control panel s power supply Input: AC 110-240V / 50-60 Hz Output: DC 12V / 500 ma GSM working frequency 850 / 900 / 1800 / 1900 mhz Standby current 110ma Alarm current 340mA Internal battery backup Lithium Battery: 3.7V / 800 mah x 2 (BL-5B) Internal siren 110dB Wireless accessories supported 10x Remote Controls, 50x Wireless Accessories, and 50x RFID Tags Radio frequency 315MHz / 433MHz (±75KHz) Housing material ABS plastic Operating condition Temperature: -10 C~55 C Humidity: 80% (non-condensing) Wireless Remote Control LED indicator Arm Home mode Arm the system Disarm Panic Press the Arm button { } to arm the alarm system. The LED indicator lights up (the siren rings out once). The system is armed. If an intruder is detected, the siren rings out. (The siren turns off after 5 minutes as per default setting.) In the meantime, the system dials the pre-stored phone numbers automatically. Disarm the system Press the Connect Button of the wireless siren. The Connect Button LED indicator lights on. Press the Arm button on the control panel. The panel beeps once: the siren is registered. Control panel dimensions (L x W x H) 188 x 132 x 26 mm Press the Disarm button { } to disarm the alarm system. The LED indicator turns off (the siren rings out twice). The system is disarmed. 14 Testing 15

Home Mode Zone Setup of Wireless Accessories Wireless Door / Window Contact Installation Press the Home Mode button { } on the remote control. The system state LED is on. All the sensors in regular zones are armed except those in the Home Mode zone. The sensors in the Home Mode zone are disarmed so that users can move inside their home. Every detector can be assigned to 4 different categories of zones: Home Mode Zone, Single Delay Zone, Normal Zone and 24-H Zone. To assign a detector to a zone, open its case and move its jumpers according to the drawing below: D0 D3 D0 D3 Features The ES-D3A is a Door / Window Contact that can be installed on doors, windows, and any other objects that open and close. The sensor sends signals to the control panel when the magnet installed next to the sensor is deconnected. Thanks to the tamper switch, any attenpt to move the Door / Window Contact will trigger the alarm. - Open the case and remove the battery activation strip. - Mount the sensor on the door and the magnet on the door frame. - Make sure the magnet is placed above of the transmitter. - Mount the magnet max. 1cm away from the transmitter and secure the transmitter and magnet with double-sided tape or screws. - Avoid mounting the sensor in areas with a large amount of metal or electrical wiring, such as a furnace or utility room. Mute Mode A. Home Mode Zone B. Single Delay Zone Magnet Transmitter D0 D3 C. Normal Zone LED indicator Press the Stay button { } on the remote control. Press the Arm button { } or the Disarm button { }. When arming or disarming the system, the siren does not ring out: the system is armed or disarmed in Mute Mode. Emergency Mode The PIR motion detector is set in Home Mode Zone by default. It is recommended to set the Door / Window Contact at the entrance of your home in Single Delay Zone. After a zone has been changed, the detector must be registered in the control panel again. D0 D3 24-H Zone LED indications Blinks once: the door or window is open and the transmitter sends a signal to the control panel. Blinks quickly: Low power indication: the batteries must be replaced. PCB Layout Tamper switch A23 12V Battery Specifications Power supply DC 12V (A23 12V Battery x 1) Static current 30 ua Alarm current 40 ma It is recommended to set the smoke detector, the gas detector and the outdoor beam sensor at 24-H zone. Regardless the status of the system, the alarm LED working indicator is triggered when the Panic button {SOS} is Radio frequency pressed on the remote control. 315 MHz / 433 MHz (±75 KHz) 16 17 Zone setting Transmitting distance 80 m (in open area)

Housing material ABS plastic Operating temperature -10 C~55 C Relative humidity 80% (non-condensing) Transmitter dimensions (LxWxH) 71 x 34 x 17.5 mm LED indications Blinks continuously: self-testing Blinks once: an intruder is detected Blinks twice: self-testing is complete; entering working mode. Blinks once every 3 seconds: under-voltage indication: the batteries must be replaced. (The user will be informed by SMS when the batteries are low if the PIR Motion Detector is registered in the control panel.) Mode Setting Test Button If two detectors are installed in the same detection scope, adjust the location to avoid interferences and false alarms. 2.2 m Top Magnet dimensions (LxWxH) 51 x 12 x 13.5 mm Wireless PIR Motion Detector Features ES-D1A (or ES-D2A: Pet-Immune Motion Detector) is a high performance wireless P.I.R. motion detector. It boasts a digital dual-core fuzzy logic infrared control chip with intelligent analysis. This technology identifies interferences created by body motion and reduces the false alarm rate. With automatic temperature compensation and anti-air turbulence technology, it easily adapts to environmental changes. PCB Layout LED working indicator Antenna Alarm zone setup Tamper switch Infrared sensor AA 1.5V LR6 Infrared sensor Detects the infrared rays released by human body motion. Do not touch the surface. Keep the surface clean. Tamper switch When the alarm system is armed, the tamper switch will trigger the alarm if the case is opened. Usage Open the case and remove the battery activation strip to activate the batteries. Selftesting will start for one minute. Testing mode Once the self-testing is complete, press the test button. The sensor switches to testing mode, and scans once every 10 seconds. After 3 minutes, the LED blinks twice, and the sensor switches to working mode. Working mode In working mode, if the sensor is triggered more than twice within 3 minutes, it will switch to standby mode to save power. If a movement is detected within the next 3 minutes, the standby mode is extended by 3 more minutes. If no movement has detected within these 3 minutes, the detectors turns back to working mode. Register in the control panel Press the Connect button { } on the control panel. Press the test button of the sensor twice. The control panel beeps once: the motion detector is registered. To check if the registration is complete, arm the system and trigger the sensor again. If the siren rings out, the registration is successful. Installation Avoid mounting the detector close 1. LED indicator to windows, air conditioner, heater, 2. Detection window refrigerator, oven, sunshine and places 3. Bracket where the temperature changes fast or where the air stream flows frequently. 18 19 Top view Ground Side view Bottom Fix the bracket on the wall with screws and attach the detector to the bracket. Adjust the bracket to change the detection distance and angle. It is recommended to mount the detector 2m from the ground. The detector is more sensitive to cross movements than vertical movements. Testing A. After one minute of self-testing, press the test button, walk in the scope of detection and watch the LED indicator to make sure the detector is working. B. The LED indicator blinks once when body movement is detected. C. Adjust the detector angle to achieve the best detection performance.

Detection Scope Standards 110 0m 2m 4m 6m 8m 2m This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment. For further information, please contact your local or regional authorities. Top view 0m Side view Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances. Specifications In compliance with European laws. Power supply DC 3V (AA 1.5V LR6 Batteries x 2) Static current 50uA This product was designed and manufactured in compliance with Directive 2002/95/EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS Directive - RoHS) and is deemed to comply with the maximum concentration values set by the European Technical Adaptation Committee (TAC). Alarm current 9.5 ma Manufactured in China. Detection scope 8m / 110 Trating distance 80m (in open area) Images, illustrations and text are non-contractual. ETIGER and the ETIGER logo are registered trademarks and the property of ETIGER. Copyright 2014 ETIGER. All rights reserved. Radio frequency 315 MHz / 433 MHz (±75 KHz) Housing material ABS plastic Operating Condition Temparature: -10 C~55 C Relative humidity: 80% (non-condensing) Detector dimensions (L x W x H) 108 x 52 x 36.8 mm Bracket dimensions (L x W x H) ETIGER EUROPE 52 x 30 x 26.5 mm Rue de la Loi, 25, 7100 La Louvière, Belgium 20 service@etiger.com 21 S3-S UM-20140328:1.2

www.etiger.com